IQ SENSOR NET MIQ/IF232

Similar documents
IQ SENSOR NET MIQ/(A-)MOD

Operating manual IQ SENSOR NET MIQ/R6. Power. IQ SENSOR NET six channel relay output module. ba76031e01 01/2012

4010-2/3 ph Adapter DIN / BNC

OPERATIONS MANUAL. ba76023e02 12/2014. DIQ/S 182 XT System 182 MODULAR MEASURING SYSTEM FOR 2 DIGITAL SENSORS (DIQ/S DIQ/CR3)

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

IF-80x Outdoor Terminal

TruLab ph/ise 1320(P)

IQ21x Series Controllers

TCNM-ACBB1 Installation Manual

Demonstration Case BENNING DB 1

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Manual DTM Digital Pressure Transmitter

Reference Guide METTLER TOLEDO WMH Weighing Platforms

Operating Instructions for Digital Thermometers. Model: DTM

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Technical data. Your advantages

FlowJam Plus. Superior with Solids. Material flow monitor with blockage detector. Operating instructions

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Inductive displacement measurement system model series IE25P with programmable analogue interface

Kinetix 300 Memory Module Programmer

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

RADIOMETER PHOTOMETER L-420 INSTRUCTION MANUAL

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

FX-485PC-IF RS485 Interface Unit Hardware Manual

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Serial PROFIBUS Interface

Intrinsically safe batch controller Batching Master 110i

DIGITAL PANEL THERMOMETER

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Environdata FA ma Converter Guide

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1. Safety Precautions (Read these precautions before use.)

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

ISE 021 S-DIAS Interface Module RS232 / RS485

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

photoflex STD Handheld colorimeter

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Installation manual for for Schleifenbauer DPM3

revos revos Industrial Multipole Connectors 3 48 pole in metal housing Program for Tough Tasks

GS202 Encoder Switch

An ISO-9001 Certified Company

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

Expansion Module HZS 541-1S

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

PCAN-Router FD Universal, programmable Converter for CAN FD and CAN. User Manual. Document version ( )

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

MX Voice Gateway Series. Installation Manual

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

Operating Instructions VEGAMET 381

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Quick Start Guide and Health and Safety Information

Minimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

Power Rack 58. EXT-PS5-8R User Manual.

Operating Instructions

DIN Rail Mounted Dial-up Modem Users Manual

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

Quickstart OPCom II. Read the safety instructions and operating instructions prior to commissioning!

MGate 5105-MB-EIP Quick Installation Guide

C-DIAS Serial Interface CSI 021

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

LASER. Laser Displacement Sensor. Series LLD-500. Key-Features:

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

LVX Control Unit. Features:

PumpDrive. Self -cooling, motor-independent frequency inverter. Brief Instructions

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

Datasheet - RSS 36-D-R-ST

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Industrial Hydraulics FAQs

RTU560 Remote Terminal Unit Connections and Settings

Distribution Systems for Sensors and Actuators

Inclinometer. 4-20mA and RS232

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

L-MBUS20/L-MBUS80. User Manual. M-Bus Level Converter. LOYTEC electronics GmbH

Rotary Measuring Technology

Summary of shell housings and accessories Shell housing A Shell housing D EMC housing

Manual 2Wire Converter

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

LASER. Laser Displacement Sensor. Series LLD-500. Key-Features:

Breadboard & Digital Input/Output Modules

Transcription:

Operating Manual IQ SENSOR NET Power! OK RS232 interface module for the IQ SENSOR NET ba76037e01 01/2012

Note For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI 1725 Brannum Lane Yellow Springs, OH 45387 USA Tel: +1 937-767-7241 800-765-4974 Email: environmental@ysi.com Internet: www.ysi.com 2012 Xylem Inc.

List of contents - List of contents 1 Overview.................................... 1-1 1.1 How to use this component operating manual........ 1-1 1.2 Features of the....................... 1-2 2 Safety instructions............................ 2-1 2.1 Authorized use................................ 2-1 2.2 General safety instructions....................... 2-2 3 Installation.................................. 3-1 3.1 Scope of delivery.............................. 3-1 3.2 Installation in the IQ SENSOR NET................. 3-1 3.3 Connecting the with the PC............. 3-2 4 Maintenance and cleaning..................... 4-1 4.1 Maintenance.................................. 4-1 4.2 Cleaning..................................... 4-1 5 Technical data............................... 5-1 6 Contact Information........................... 6-1 6.1 Ordering & Technical Support.................... 6-1 6.2 Service Information............................ 6-1 ba76037d01 01/2012 0-1

List of contents 0-2 ba76037d01 01/2012

Overview 1 Overview 1.1 How to use this component operating manual Structure of the IQ SENSOR NET operating manual IQ Sensor Net Operating Manual System Operating Manual (Ring Binder) IQ Sensor Operating Manual MIQ Module Operating Manual MIQ Terminal Operating Manual Component Operating Manuals Fig. 1-1 Structure of the IQ SENSOR NET operating manual The IQ SENSOR NET operating manual has a modular structure like the IQ SENSOR NET system itself. It consists of a system operating manual and the operating manuals of all the components used. Please file this component operating manual into the ring binder of the system operating manual. ba76037d01 01/2012 1-1

Overview 1.2 Features of the General characteristics The expands the IQ SENSOR NET by an RS232 interface. This enables a connection between the IQ SENSOR NET and a PC. With the aid of the IQ SENSOR NET software pack, the following functions, for example, can be carried out on a PC: (Remote) Operation and (remote) monitoring of the IQ SENSOR NET via the MIQ/T2020 PC software terminal. The software terminal has the same operating concept as other terminal components (e.g. MIQ/T2020). This means that is hardly necessary to "get used" to it when changing between the different types of terminal. (Remote) Data transmission of current measured data (Remote) Data transmission of saved measured data Remote backing up/loading of the IQ SENSOR NET system configuration Note Details for the operation of the software are given in the operating manual of the IQ SENSOR NET software pack. With the standard MIQ module housing, the has the same characteristics as all MIQ modules regarding stability, leakproofness and weather resistance. It also provides the same wide variety of installation options (stacked mounting, canopy mounting, tophat rail mounting, etc.). Terminal strip The has the following electrical connections on the terminal strip inside the housing: 1 x RS 232 connection, already wired up with cable and connector 3 x SENSORNET connection 1-2 ba76037d01 01/2012

Safety instructions 2 Safety instructions This component operating manual contains special instructions that must be followed during the installation of the interface module. Thus, it is essential to read this component operating manual before carrying out any work using this sensor. In addition to this manual, the SAFETY chapter of the IQ SENSOR NET system operating manual must be followed. Always keep this component operating manual together with the system operating manual and all other component operating manuals in the vicinity of the IQ SENSOR NET system. Directions The following symbols indicate special features in the individual chapters of this operating manual: Note indicates notes that draw your attention to special features. Note indicates cross-references to other documents, e.g. operating manuals. 2.1 Authorized use The authorized use of the consists of its use as an RS232 interface converter between IQ SENSOR NET and a PC. The technical specifications given in chapter 5 TECHNICAL DATA must be observed. Only operation according to the instructions in this operating manual is authorized. Any other use is considered to be unauthorized. Unauthorized use invalidates any claims with regard to the guarantee. ba76037d01 01/2012 2-1

Safety instructions 2.2 General safety instructions The is constructed and inspected in accordance with the relevant guidelines and norms for electronic instruments (see chapter 5 TECHNICAL DATA). It left the factory in a safe and secure technical condition. Function and operating safety The failure-free function and operational safety of the is only guaranteed if the generally applicable safety measures and the special safety instructions in this operating manual are followed during its use. The failure-free function and operational safety of the is only guaranteed under the environmental conditions that are specified in chapter 5 TECHNICAL DATA. Safe operation If safe operation is no longer possible, the must be taken out of operation and secured against inadvertent operation. Safe operation is no longer possible if the : has been damaged in transport has been stored under adverse conditions for a lengthy period of time is visibly damaged no longer operates as described in this manual. If you are in any doubt, contact the supplier of your. 2-2 ba76037d01 01/2012

GREEN SHIELD RED SN TERMINATOR GREEN SHIELD RED GREEN SHIELD RED GND RS 232 TxD RxD Installation 3 Installation 3.1 Scope of delivery The following parts are contained in the scope of delivery of the MIQ/ IF232: module with permanently mounted interface cable and connector. All openings and open electrical contacts are closed with suitable covers or blank covers. 4 x cable glands with seal 2 x ISO blind nuts M4 2 x cheese-head screws M4x16 with plastic washer 1 x contact base 2 x plastic tapping screws for fixing the contact base IQ SENSOR NET software pack Operating manual. 3.2 Installation in the IQ SENSOR NET The IQ SENSOR NET provides a number of options for integrating the mechanically and electrically in the system (stacked mounting, distributed mounting, etc.). The various types of installation are described in detail in the INSTALLATION chapter of the system operating manual. Terminal strip X12 X11 X10 X9 X8 X7 X6 X5 X4 X3 X2 X1 ON OFF RS 232 SENSORNET 3 SENSORNET 2 SENSORNET 1 Fig. 3-1 Terminal strip of the ba76037d01 01/2012 3-1

Installation RS 232 The RS 232 interface cable is already connected to the terminal strip in the factory. Wire Terminal Green (shield) GND RS 232 Brown White RxD TxD SENSORNET All SENSORNET connections are identical and can be used as required for extending/branching the cable section or for the connection of sensors. 3.3 Connecting the with the PC Connect the interface cable of the with the 9-pole connector to any free RS 232/COM connection on the computer. Note The connecting cable between and PC can be extended by a 1:1 extension cable. However, a short cable is better for good EMC characteristics. If the distances to the IQ SENSOR NET system are long, install the in the vicinity of the PC so that no extension is required. Bridge the distance to the IQ SENSOR NET system with the IQ SENSOR NET SNCIQ or SNCIQ/UG (distributed mounting) cable. Note Details for the installation of the software are given in the operating manual on the IQ SENSOR NET software pack. 3-2 ba76037d01 01/2012

Maintenance and cleaning 4 Maintenance and cleaning 4.1 Maintenance The requires no special maintenance. The general maintenance of IQ SENSOR NET components is described in the IQ SENSOR NET system operating manual. 4.2 Cleaning The cleaning of IQ SENSOR NET components is described in the IQ SENSOR NET system operating manual. ba76037d01 01/2012 4-1

Maintenance and cleaning 4-2 ba76037d01 01/2012

Technical data 5 Technical data Note General technical data on MIQ modules are given in the TECHNICAL DATA chapter of the IQ SENSOR NET system operating manual. Electrical data Nominal voltage Power consumption Protective class Max. 24 VDC via the IQ SENSOR NET (for more details, see chapter TECHNICAL DATA of the IQ SENSOR NET system operating manual). Approx. 0.2 W III Instrument safety Applicable norms EN 61010-1 UL 3111-1 CAN/CSA C22.2 No. 1010.1 Number of in the IQ SENSOR NET The counts as a terminal component. A total of up to three terminal components can be used in the IQ SENSOR NET. Terminal connections IQ SENSOR NET connections RS 232 Terminal type Terminal ranges Cable feeds 3 Additional connectable SENSORNET terminator (terminating resistor) GND RS 232, TxD, RxD Screw-type terminal strip, accessible by opening the lid Solid wires: Flexible wires: 0.2... 4.0 mm 2 AWG 24... 12 0.2... 2.5 mm 2 4 cable glands M16 x 1.5 on the underside of the module RS 232 cable Length Plug connection to the PC 3 m Connected with the in the factory D-sub, 9-pole ba76037d01 01/2012 5-1

Technical data 5-2 ba76037d01 01/2012

Contact Information 6 Contact Information 6.1 Ordering & Technical Support Telephone: (800) 897-4151 (937) 767-7241 Monday through Friday, 8:00 AM to 5:00 PM ET Fax: (937) 767-1058 Email: Mail: Internet: environmental@ysi.com YSI Incorporated 1725 Brannum Lane Yellow Springs, OH 45387 USA www.ysi.com When placing an order please have the following information available: YSI account number (if available) Model number or brief description Quantity Name and Phone Number Billing and shipping address Purchase Order or Credit Card 6.2 Service Information YSI has authorized service centers throughout the United States and Internationally. For the nearest service center information, please visit www.ysi.com and click Support or contact YSI Technical Support directly at 800-897-4151. When returning a product for service, include the Product Return form with cleaning certification. The form must be completely filled out for an YSI Service Center to accept the instrument for service. The Product Return form may be downloaded at www.ysi.com and clicking on the Support tab. ba76037e01 01/2012 6-1

Contact Information 6-2 ba76037e01 01/2012

1725 Brannum Lane Yellow Springs, Ohio 45387 USA +1 937-767-7241 800-765-4974 (US) FAX (937) 767-1058 Email: environmental@ysi.com Internet: www.ysi.com