C1U-W Tx Series AC/DC Front End Power Supply

Similar documents
C1U-W Tx Series

D1U4CS-W HxxC Series AC/DC Front End Power Supply

D1U-W Hx Series

D1U-W Hx Series

D1U3CS-D HxxC Series 81mm 1U Front End DC-DC Power Supply Converter

D1U3CS-W HxxC Series

D1U2-D HA4C 54mm 1U Front End DC-DC Power Supply Converter

D1U5CS-H HA4C

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

D1U54-D HxxPC Series 54mm 1U Front End DC-DC Power Converter PRODUCT OVERVIEW FEATURES

D1U54-HD HA4C 54mm 1U Front End HVDC Power Supply Converter

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Safety Standards. Model Number: Unit Weight:

60 Watt Medical (MWLT)

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Consult with factory for availability INPUT CHARACTERISTICS. Consult with factory for details and availability OUTPUT CHARACTERISTICS

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

MVAC400 Series 400W 3" x 5" High Density AC-DC Power Supply Converter

D1U54P-W HxxTC Series

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

275 Watt Medical Ultra low profile

CPS Industrial Power Supply

The ATF YE meets UL/CSA and all international safety requirements. CE mark is pending. Min Typ Max

Cool. NFF Series. CoolX600 NFF Series. NFF Series; No Fan Featured

SPECIFICATION. Model: PS3038. Redundant Power Supply With Active PFC 700W + 700W

Safety Standards. Model Number:

Universal Power Supplies

Safety Standards. Model Number:

Safety Standards. Model Number:

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Electrical Specifications. Input Input range: Vac Hz, single phase AC. 92% typical at high line 50% load. FCC Subpart J EN55022 Class A

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

CINT W Triple Output Industrial Series

Safety Standards. Model Number:

Safety Standards. Model Number:

CINT W Single Output Industrial Series

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

VCN60/70 Series High Effi ciency, High Current Density, 60 or 70 Amp Single Inline Package DC/DC Converters

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40

Constant Voltage Mode

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

Safety Standards. Model Number:

MVAC400 Series 400W 3" x 5" High Density AC-DC Power Supply Converter

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

RT4B-110V/12A RECTIFIER

Safety Standards. Model Number:

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Output Voltage* (nom.)(adjustable)

Safety Standards. Model Number:

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number:

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

78xxSR Series 3.3V/5V/12V Outputs High-Effi ciency Switching Regulators with LM78xx Pinouts

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

Safety Standards. Model Number:

Chrome DIN Rail Power Supply 12V 72W 1 Phase (Class II) / DRC-12V100W1AZ

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

Safety Standards. Model Number:

Enclosed Power Supplies

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

CPCI - 6U - AC - 600W

PMT. Safety Standards. Model Number:

AC-DC Power Supplies. The PerFormanCe Power PFC250 meets international safety requirements and is CE Marked to the Low Voltage Directive.

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

AEA400S-4 Power Supply Product Specification. An APM Electronics USA, Inc. 400W Power Supply Specification For Standard PS2 Mini Redundant PSU

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

RT4F-48V/50A-WAC RECTIFIER

RT4F-110V/25A RECTIFIER

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

SST-NJ450-SXL. Nightjar Series. The definitive small form factor fanless power supply

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Snaptec Australia Pty. Ltd.

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V600W1BA Vac ( Vdc) 24Vdc 25.

Transcription:

www.murata-ps.com PRODUCT OVERVIEW The C1U-W-1200 is a 1200 Watt universal AC input, power-factor-corrected (PFC) front-end power supply for general applications. The main output is 48V with a standby output of either 5V, 3.3V, or 12V. Packaged in a 1U low profi le chassis, it is designed to deliver reliable bulk power to servers, workstations, storage systems or any 48V distributed power architecture systems requiring high power density. The highly effi cient electrical and thermal design with internal cooling fans supports reliable operation conditions. The C1U-W-1200 is designed to autorecover from overtemperature faults. FEATURES 1200W (110/220Vac) power 48V Main output, 3.3V, 5V or 12V standby output Dimensions: 5.5" x 14.2" x 1.67" 9.2 Watts per cubic inch density N+1 redundancy capable (up to 3 in parallel) Active current sharing on main output Overvoltage, overcurrent, overtemperature protection Internal cooling fans RoHS compliant SELECTION GUIDE Part Number Power Universal Line Main Standby Airfl ow C1U-W-1200-48-TA1C 1200W 48V 5V Front to back C1U-W-1200-48-TC1C 1200W 48V 3.3V Front to back C1U-W-1200-48-TA2C 1200W 48V 5V Back to front C1U-W-1200-48-TC2C 1200W 48V 3.3V Back to front C1U-W-1200-48-TB1C 1200W 48V 12V Front to back C1U-W-1200-48-TB2C 1200W 48V 12V Back to front INPUT CHARACTERISTICS Input Voltage Operating Range 90 115/230 264 Vac Input Frequency 47 55 63 Hz Turn-on Input Voltage Ramp up 78.5 86.5 Turn-off Input Voltage Ramp down 70.5 78 Vac Maximum Input Current 15 Arms Inrush Current 90 Apk Power Factor load >90% 95% load >50% 75% OUTPUT VOLTAGE CHARACTERISTICS Voltage Voltage Set Point Accuracy 48 Line and Load Regulation 46.54 49.44 48V Ripple Voltage & Noise 1 20MHz Bandwidth 480 mv p-p Current 2 24.6 A Load Capacitance 10000 μf Voltage Set Point Accuracy 3.3 Line and Load Regulation 3.2 3.4 3.3Vsb Ripple Voltage & Noise 1 20MHz Bandwidth 50 mv p-p Operating Range 0 4.5 A Voltage Set Point Accuracy 5 Line and Load Regulation 4.85 5.15 5Vsb Ripple Voltage & Noise 1 20MHz Bandwidth 50 mv p-p Operating Range 0 4 A Voltage Set Point Accuracy 12 Line and Load Regulation 11.2 12.4 12Vsb Ripple Voltage & Noise 1 20MHz Bandwidth 120 mv p-p Operating Range 0 1.7 A 1 Ripple and noise are measured with 0.1 uf of ceramic capacitance and 10 uf of tantalum capacitance on each of the power supply outputs. A short coaxial cable with 50ohm scope termination is used. For full details go to www.murata-ps.com/rohs CPS_C1U-W-1200-48-Tx.B02 Page 1 of 5

OUTPUT CHARACTERISTICS Remote Sense Compensates for up to 0.12V of lead drop with or without remote sense connected 120 mv Effi ciency 220Vac 90.6 % Rise Monotonicity Overshoot less than 10% for all outputs, no voltage negative between 10% to 95% during ramp up Startup Time AC ramp up 1.5 s PS_On activated 150 ms 48V Ramp 1A/μs ±600 Transient Response 12Vsb Ramp 1A/μs 3.3Vsb Ramp 1A/μs ±165 5Vsb Ramp 1A/μs ±250 mv Current sharing accuracy (up to 3 in parallel) At 100% load ±10 % Holdup Time 20 ms ENVIRONMENTAL CHARACTERISTICS Storage Temperature Range Non-condensing -40 70 Operating Temperature Range 0 50 C Operating Humidity Non-condensing 10 90 Storage Humidity 5 90 % Shock 30G non operating Sinusoidal Vibration 0.5G, 5 500 Hz MTBF Telcordia SR-332 @ 30 C 200K hrs Demonstrated 200K hrs CAN/CSA C22.2 No. 60950-1-07, 2nd Ed. Safety Approvals UL 60950-1, 2nd Ed. IEC 60950-1:2005 (2nd Edition); EN 60950-1:2006 +A11 Input Fuse Power Supply has internal 20A/250V fast blow fuse on the AC line input Material Flammability UL 94V-0 90KHz for Boost PFC Converter Switching Frequency 165KHz for Main Converter 200KHz for Standby Converter Weight 5.7 lbs (2.6kg) PROTECTION CHARACTERISTICS Voltage Overtemperature Autorestart 55 65 C 48V Overvoltage Latching 54 59 V Overcurrent Latching 26 35 A 3.3Vsb Overvoltage Latching 3.57 4.02 V Overcurrent Latching 6.5 8 A 5Vsb Overvoltage Latching 5.6 6 V Overcurrent Latching 5 7 A 12Vsb Overvoltage Latching 13 14 V Overcurrent Latching 2.5 3 A ISOLATION CHARACTERISTICS Insulation Safety Rating / Test Voltage Input to - Reinforced 3000 Vrms Input to Chassis - Basic 1500 Vrms Isolation to Chassis to Main Return and Standby Return are connected internally. 100kΩ resistor parallel with 100nF Grounding capacitor is connected between Return and power supply chassis. Main Return should be connected to the System Chassis. CPS_C1U-W-1200-48-Tx.B02 Page 2 of 5

STATUS INDICATORS AND CONTROL SIGNALS Status Conditions Description Off No AC input to all PS LED Flashing Yellow Power Supply Failure Flashing Green Main Absent Green Power Supply Good To enable main output Short to GND (required) Short SENSE+ to 48 main at point of load (optional for better regulation) Short SENSE- to GND at point of load (optional for better regulation) EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics IEC/EN 61000-3-2 Complies Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies Conducted Emissions FCC 47 CFR Part 15/CISPR 22/EN55022 Class A, 6dB margin Radiated Emissions FCC 47 CFR Part 15/CISPR 22/EN55022 Class A, 6dB margin ESD Immunity IEC/EN 61000-4-2 4kV contact discharge 8kV operational air discharge 15kV non-operational air discharge Radiated Field Immunity IEC/EN 61000-4-3 Complies Electrical Fast Transients/Burst Immunity IEC/EN 61000-4-4 Complies Surge Immunity IEC/EN 61000-4-5 1kV/2kV, Performance Criteria B RF Conducted Immunity IEC/EN 61000-4-6 3 Vac, 80% AM, 1kHz, Performance Criteria A Magnetic Field Immunity IEC/EN 61000-4-8 3 A/m Voltage Dips, Interruptions IEC/EN 61000-4-11 Complies CPS_C1U-W-1200-48-Tx.B02 Page 3 of 5

WIRING DIAGRAM FOR OUTPUT Dotted lines show optional remote sense connections. Optional remote sense lines can be attached to a load that is a distance away from the power supply to improve regulation at the load. SENSE+ SENSE+ 7 + STUD 48V Main 48V Main + STUD 7 C1U 48V load C1U - STUD GND GND - STUD 8 5 SENSE- ISHARE SENSE- ISHARE 8 5 9, 10, 11, 12 3 13, 14, 15, 16 V_SB GND Close switch (or FET, BJT, or wire) to turn on 12V Main +3.3 or +5V logic circuitry V_SB GND 9, 10, 11, 12 3 13, 14, 15, 16 R 100k C 100nF R1 100k C1 100nF CURRENT SHARING NOTES Main : Current sharing is achieved using the active current share method. (See wiring diagram for connection details.) The total combined load must be below 1200W at startup. Current sharing can be achieved with or without remote sense connected to the common load. V_SB outputs can be tied together for redundancy but total combined output power must not exceed 20W. The V_SB output has internal ORing MOSFET for additional redundancy / internal short protection. The current share pin 5 is a connection between the two units. It is input and/or output as the voltage on the line controls the current share. A power supply will respond to a change in this voltage but a power supply can also change the voltage depending on the load drawn from it. On a single unit this would read 8V at 100% load. For two units sharing load then this should read 4V for perfect current sharing. Up to 3 units can be paralleled together. Please consult your Murata sales representative if operation with more than three units in parallel is needed. CPS_C1U-W-1200-48-Tx.B02 Page 4 of 5

MECHANICAL DIMENSIONS 5.500 (139.70) 15.197 (386.00) REF 14.220 (361.20) AC Input Terminal Block M4 Ground Stud 1.673 (42.50) Signal Connector Terminal M5 Studs M4 Mounting Thread (4X) 5.000 (127.00) Dimensions: 5.5 " x 14.2" x 1.67" [139.7mm x 361.2mm x 42.5mm] CONNECTORS Signal 16 pin connector details, Type: TE Connectivity (Tyco) 281281-1 Mating part 1658622-3 Pin Signal 1 AC_OK 2 P_GOOD 3 4 BLANK 5 I_SHARE 6 BLANK 7 SENSE+ 8 SENSE- 9 V_SB 10 V_SB 11 V_SB 12 V_SB 13 GND 14 GND 15 GND 16 GND 2-Pole terminal Block for AC Line and Neutral Stud on Chassis for earth + 48V Main - GND 4.803 (122.00) 4.847 (123.12) Front View Terminal M5 Studs Pin 1 Pin 2 Signal Connector Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. 2017 Murata Power Solutions Inc. CPS_C1U-W-1200-48-Tx.B02 Page 5 of 5