References. For SIRCO MV. References

Similar documents
References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

References. References. Rating (A) Référence

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

FUSERBLOC and high speed fuses (ur) Fuse combination switches protection of power semi-conductors up to 1250 A

SIRCO Load break switches for power distribution from 125 to 5000 A

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Make the Switch. Your Specialist in CONTROL SOLUTIONS SPEEDY BUILD. AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (20A A)

the Santon FCS-type switch Disconnect Superior Switch Solutions

Load-break switches and switch-fuses, safety isolating switches, fuses and fusegear, changeover and transfer switches

MOTOR PROTECTION CIRCUIT BREAKERS

Pan assemblies and installation accessories

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

Enclosed transfer switches Manual & automatic transfer switching equipment steel enclosures - from 40 to 3200 A

SWITCH DISCONNECTORS 11

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

TP&N DISTRIBUTION BOARD TYPE B RANGE

FUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC

Interpact Switch-disconnectors INS/INV40 to 2500 A. INS/INV Standard version with black handle - Fixed /FC

Dorman Smith Loadbank 125 MCCB Panel Boards

ic60n RCBO 30 ma IEC , IEC , AS/NZS

DISCONNECT SWITCHES > QUICK REFERENCE GUIDE north american edition

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

3RV1 Circuit-Breakers

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

Complete UL/CSA Disconnect Switch Kits

NEW Titan II A & B Distribution Boards

Description. Installation. Power supply

3RA13, 3RA14 Contactor Assemblies

US Catalog July 2016 SMISSLINE TP

Switch Disconnectors, Main and EMERGENCY-STOP Switches

DC Load Break Switch

Performance. Standards. Technical data

Non-Fusible Disconnect Switches

Allen-Bradley 1492-RCDA4A40

Go to:

WMS SUPPLEMENTARY PROTECTORS

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

CS8 Industrial Control Relays

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Powerpact 4 panelboards Panelboards and incoming devices Panelboards

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

QUICK REFERENCE PRICE GUIDE JUNE 2016

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices

Consumer units IP66 >> M135 DOMINO IP66 Series [enclosure] 672.

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

Contents. Volume 5 Motor Control and Protection CA E December

Non-Fusible Disconnect Switches

The right solution for every home

6 - WEATHERPROOF SWITCHGEAR

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320

LOADSTAR MCBs AND DISTRIBUTION BOARDS

NW08 to NW63 fixed circuit breakers Circuit breakers

1/5 SING.-FMLY KIT W/VANDALCOM & PC INTERCOM VIP SYST. KIT H.264 OVERVIEW 8504H

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Distribution blocks Distribution

topter SERIES ACTIVE PROTECTION Leading Electrotechnology

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

Magnetically Actuated Safety Interlock Switches

Product range E 210 On-off switches, pushbuttons, indicator lights System pro M compact. Power and productivity for a better world TM ABB

TO ALL OUR CUSTOMERS 1. NEW ADVANCE GRP SERIES - 16A-32A-63A INTERLOCKED SOCKETS IN THERMOSET TING MATERIAL

Electrical Demand Specification (Reference SOP: )

General Informations 2 Technical data 3 Basic designs 4-8

Automatic Transfer Switch OTM_C_20D. Installation and Operation Instructions

US CATALOG SMISSLINE TP

Motor protection relays

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

P17 Tempra and Hypra Plugs and Sockets

BASE. Rotary limit switch OPTIONS FEATURES CERTIFICATIONS

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Surge Protection Devices and Surge Protection Kit

Defender B Board. Make The Switch

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

information service Pag.1

A-100G6 - Basic frame assembly diagram

IT power distribution Power distribution units (PDU) Basic. Versions available:

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Talisman Plus. MCB Distribution Boards & Miniature Circuit Breakers BILL MEANS BUSINESS

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

MOTOR & CIRCUIT PROTECTION

Motor Control Products Selection Guide

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

Lightning and Surge Arresters

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

UL 98 Fusible Disconnect Switches

The safest way to switch power on and off in your industrial control panels.

Pop-Up Number(s) : to 03, to 08, to 13,

Isobar 4c distribution boards and devices Selection guide

for a perfect electrical installation. The range of rail-mounted terminal blocks

PICO PROTECTOR PG-25 & PK-25 Series

Transcription:

16 to 160 A Functions Dimensions sircm_071_b_1_x_cat Direct handle M00 handle sircm_041_a_1_x_cat M01 handle Handle colour Handle 16 80 100 125 Blue Blue M00-type M01-type 2299 5012 2299 5032 Handle colour Handle 100 160 Blue M0-type 2299 5022 sircm_042_b_1_x_cat M0 handle Door interlocked external handle sircm_043_a_1_x_cat sircm_044_a_1_x_cat sircm_087_a_1_x_cat S00 handle S0 handle S1 handle - Front and right side operation I - 0 Handle colour Handle External IP 16 80 Black S00-type IP55 1471 1111 (1) 16 80 Black S00-type IP65 1473 1111 (1) 16 80 Red/Yellow S00-type IP65 1474 1111 (1) 100 125 Black S0-type IP55 1481 1111 (1) 100 125 Black S0-type IP65 1483 1111 (1) 100 125 Red/Yellow S0-type IP65 1484 1111 (1) 16 125 Black S1-type IP55 1411 2111 (1)(2) 16 125 Black S1-type IP65 1413 2111 (1)(2) 16 125 Red/Yellow S1-type IP65 1414 2111 (1)(2) - Left side operation I - 0 Handle colour Handle External IP 16 80 Black S00-type IP65 147A 5111 16 80 Red/Yellow S00-type IP65 147B 5111 100 125 Black S0-type IP65 148A 5111 100 125 Red/Yellow S0-type IP65 148B 5111 16 125 Black S1-type IP65 141A 2111 (1)(2) 16 125 Red/Yellow S1-type IP65 141B 2111 (1)(2) For SIRCOVER M changeover switches - Front operation I - 0 - II Handle colour Handle External IP 16 80 Black S00-type IP65 1473 1113 16 80 Black S1-type IP65 1413 2113 (1)(2) For SIRCOVER M changeover switches - Front operation I - I+II - II Handle colour Handle External IP 16 80 Black S00-type IP65 1473 1114 16 80 Black S1-type IP65 1413 2114 (1)(2) (1) Defeatable handle. (2) Door interlocked when padlocked in off. A. 12 This document is not a contract. SOCOMEC reserves the right to modify features SOCOMEC general catalogue

Door interlocked external handle - SIRCO MV sircm_044_a_1_x_cat sircm_087_a_1_x_cat S0 handle S1 handle S0 type handle - Front and right side operation I - 0 Handle colour External IP 100 160 Black IP55 1491 0111 (1) 100 160 Black IP65 1493 0111 (1) 100 160 Red/Yellow IP65 1494 0111 (1) S0 type handle - Left side operation I - 0 Handle colour External IP 100 160 Black IP65 149A 9111 100 160 Red/Yellow IP65 149B 9111 S1 type handle - Front operation I - 0 Handle colour External IP 100 160 Black IP55 1411 2111 (1) 100 160 Black IP65 1413 2111 (1) 100 160 Red/Yellow IP65 1414 2111 (1) S1 type handle - Right side operation I - 0 Handle colour External IP 100 160 Black IP55 1415 2111 100 160 Black IP65 1417 2111 100 160 Red/Yellow IP65 1418 2111 S1 type handle - Left side operation I - 0 Handle colour External IP 100 160 Black IP65 141A 2111 100 160 Red/Yellow IP65 141B 2111 (1) Defeatable handle. sircm_045_a_1_x_cat Shaft extensions for external handle Standard lengths: - 150 mm, - 200 mm, - 320 mm. Other lengths: please consult us. For 3/4 pole switches: shaft extensions for external front and side handle. For 6/8 pole switches and SIRCOVER M changeover switches: shaft extensions for external front handle only. Handle Shaft length (mm) 16 125 S00-type 150 1407 0515 16 125 S00-type 200 1407 0520 16 125 S00-type 320 1407 0532 16 125 S1-type 200 1404 0520 16 125 S1-type 320 1404 0532 16 125 S1-type 400 1404 0540 Handle Shaft length (mm) 100 160 S0-type 150 1409 0615 100 160 S0-type 200 1409 0620 100 160 S0-type 320 1409 0632 100 160 S1-type 200 1401 0620 100 160 S1-type 320 1401 0632 100 160 S1-type 400 1401 0640 Guide cone The guide cone makes it possible for S00 and S0 handles to accept a shaft with up to 10 mm of vertical play. Handle 16 160 S00 and S0-type 1419 0000 (1) (1) 10 units per pack. SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify features A. 13

16 to 160 A Functions Dimensions Additional poles configurations SIRCO M sircm_078_a_1_gb_cat PE or N sircm_072_b_1_x_cat Switched fourth pole module Adds one or two poles and transforms: - 3 pole SIRCO M load break switches into a 4 pole, - 6 pole SIRCO M load break switches into a 8 pole, - 3 pole SIRCOVER M changeover switches into a 4 pole. No. of pole 16 1 P switched 2200 1000 20 1 P switched 2200 1001 25 1 P switched 2200 1002 32 1 P switched 2200 1003 40 1 P switched 2200 1004 63 1 P switched 2200 1006 80 1 P switched 2200 1008 100 1 P switched 2200 1010 125 1 P switched 2200 1011 sircm_073_b_1_x_cat Unswitched neutral pole Transforms the 3-pole switch into a 3-pole + solid neutral. No. of pole 16 40 1 P unswitched 2200 5005 63 80 1 P unswitched 2200 5009 100 125 1 P unswitched 2200 5011 sircm_074_b_1_x_cat Protective earth module Adds 1 protective earth module pole to the switch-disconnector. No. of pole 16 40 1 P unswitched 2200 9005 63 80 1 P unswitched 2200 9009 100 125 1 P unswitched 2200 9011 A. 14 This document is not a contract. SOCOMEC reserves the right to modify features SOCOMEC general catalogue

Auxiliary contacts configurations SIRCO M and SIRCOVER M SIRCO MV 1 2 1 2 sircm_081_a_1_cat sircm_098_a_1_cat 1. Max. 2 U type auxiliary contacts. 2. Max. 4 M type auxiliary contacts. sircm_075_b M type auxiliary contacts Pre-break and signalisation of positions 0 and I by NO+NC or 2 NO auxiliary contacts. They can be mounted on the left or on the right side of the device. Max 4 auxiliary contacts (2 modules). Pre-break is not guaranteed on the SIRCO MV. NO+NC auxiliary contacts: IP2 with front operation. 16 125 1 NO + NC AC 2299 0001 16 125 2 NO AC 2299 0011 (1) 100 160 1 NO + NC AC 2299 0001 100 160 2 NO AC 2299 0011 (1) Signalling contact only. Contact Nominal Operating current I e (A) 230 VAC type current (A) AC-13 AC-15 NO+NC 10 10 6 sircm_048_a_1_x_cat U type auxiliary contacts Pre-break and signalisation by NO or NC auxiliary contact can be mounted on the device. Only switable for SIRCO MV switches. Max 2 auxiliary contacts. 100 160 1 NO AC 3999 0701 100 160 1 NC AC 3999 0702 SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify features A. 15

16 to 160 A Functions Dimensions sircm_049_a_1_x_cat Terminal shrouds Top and bottom protection against direct contact with the terminals or connection parts: - 1 or 3 pole for SIRCO M and SIRCOVER M, - 3 or 4 pole for SIRCO MV. 1 piece required to fully shroud both incoming and outgoing terminals. Advantage Perforations allowing thermographic inspection without removing. No. of pole Position 16 40 1 P top and bottom 2294 1005 16 40 3 P top and bottom 2294 3005 63 80 1 P top and bottom 2294 1009 63 80 3 P top and bottom 2294 3009 100 125 1 P top and bottom 2294 1011 100 125 3 P top and bottom 2294 3016 No. of pole Position 100 160 3 P top and bottom 2294 3016 100 160 4 P top and bottom 2294 4016 sircm_050_c sircm_086_b_1_cat Conversion kit Conversion kit for 6 or 8 pole SIRCO M load break switches This accessory enables the assembly of two 3 pole switches + additional poles in order to achieve: - 6 or 8 pole SIRCO M load break switches, - 3 or 4 pole SIRCOVER M changeover switches. SIRCOVER M changeover switches ensure switching, transfer of sources (I - 0 - II) or transfer of two low voltage circuits on load (I - I+II - II), with the continuity of power supply. 16 80 6/8-pole load break switches 2269 6009 For SIRCOVER M 16 80 changeover switches (I - 0 - II) 2209 6009 16 80 changeover switches (I - I+II - II) 2299 6009 sircm_097_b_1_x_cat Conversion kit for 3 or 4 pole SIRCOVER M changeover switches (I - 0 - II) or (I - I+II - II) For direct operation, the handle is included but not the shaft. For external operation, add the handle + the shaft. Voltage sensing and power supply tap atysm_026_a_1_cat Allows up to 2 x <=1.5 mm 2 voltage sensing or power cables connection. Only suitable for SIRCO MV switches. No. of parts 100 160 Pair 1399 4006 (1) (1) 2 parts per reference. A. 16 This document is not a contract. SOCOMEC reserves the right to modify features SOCOMEC general catalogue

sircm_051_b Door / Panel mounting kit This kit enables direct mounting of the switch on the door panel, on the right or left side of the panel. Moreover, the connection clamps of the switch are always accessible. The external handle is quick and easy to install due to an internal locking nut mounted on the inside of the enclosure. No. of pole Description 16 80 3/4 P Complete protection IP2X 2299 3309 (1) 16 80 3/4 P Overall dimensions reduced 2299 3409 (1) (1) Delivered with shaft. 2 kits are available: - one for complete protection IP2X, - one with overall dimensions reduced. Cap for side operation mounting sircm_126_a_1_cat Accessory for capping the front face of the SIRCO M when utilising in side operation. 20 units per pack. This piece can be snapped on the switch body directly. 16 80 Pack qty 20 2299 9409 6/8 pole joining accessory sircm_134_a_1_cat 40 units per pack, they allow the joining of two 3 pole switches (+ additional pole) in order to form a 6 or 8 pole switch for external side operation. For multi-poles switches, please consult us. 16 80 Pack qty 40 2299 9909 DIN rail locking clip sircm_128_a_1_cat This locking clip prevents the SIRCO MV from sliding when DIN rail mounted. For use in external side operation. 100 160 M4 5000 0041 100 160 M5 5000 0051 SOCOMEC general catalogue This document is not a contract. SOCOMEC reserves the right to modify features A. 17