1 ic60n RCBO 30 ma DB Country approval pictograms IEC , IEC , AS/NZS PB b The single-phase ic60n RCBO s self-contained residual current device provides protection of final circuits: v protection against short circuits and cable overloads v protection against electrocution by direct contact. b The neutral is not interrupted when the device is tripped. Alternating current (AC) 50/60 Hz Breaking capacity (Icn) according to IEC Voltage (Ue) Ph/N 240 V Rating (In) 6 to 45 A 6000 A Padlocking device b Used to lock the toggle in the "open" or "closed" position by 4 mm diameter padlock (not supplied). DB Catalogue numbers ic60n RCBO P+N A Width in 9 mm modules C curve Voltage rating (V) Sensitivity (I n) 30 ma Operating frequency Auxiliaries 240 Rating (In) 6 A A9D A A9D A A9D A A9D A A9D A A9D A A9D A A9D Hz Remote tripping and indication, module CA and CA Type Padlocking device (bag of 10 pieces) A9A
2 ic60h RCBO DB Country approval pictograms IEC , IEC , BS EN AS/NZS PB b The single-phase ic60h RCBO s self-contained residual current device provides protection of final circuits: v protection against short circuits and cable overloads v protection of persons against electric shock by direct contact (30 ma sensitivities) v protection of persons against electric shock by indirect contact (100 ma sensitivity) v protection of equipment against fires set by leakage currents (100 ma sensitivity). b The neutral is not interrupted when the device is tripped. Alternating current (AC) 50/60 Hz Breaking capacity (Icn) according to IEC Voltage (Ue) Ph/N 110 V 240 V Rating (In) 6 to 45 A A A Padlocking device b Used to lock the toggle in the "open" or "closed" position by 4 mm diameter padlock (not supplied). DB DB Catalogue numbers ic60h RCBO P+N A Width in 9 mm modules B curve Voltage rating (V) Sensitivity (I n) 30 ma 100 ma 240 Rating (In) 6 A A9D A A9D A A9D A A9D A A9D A A9D A A9D A A9D C curve Voltage rating (V) Sensitivity (I n) 30 ma 100 ma Operating frequency Auxiliaries 110 Rating (In) 10 A A9D A A9D A A9D A A9D A A9D Rating (In) 6 A A9D11806 A9D A A9D11810 A9D A A9D11816 A9D A A9D11820 A9D A A9D11825 A9D A A9D11832 A9D A A9D11840 A9D A A9D11845 A9D Hz Remote tripping and indication, module CA and CA Type Padlocking device (bag of 10 pieces) A9A
3 ic60h2 RCBO 30 ma DB Country approval pictograms IEC , IEC , AS/NZS PB b The 2-pole ic60h2 RCBO's self-contained residual current device provides protection of final circuits: v protection against short circuits and cable overloads v protection of persons against electric shock by direct contact. b ic60h2 RCBO switches neutral, together with phase. It is therefore suitable for all circuits, whatever the earthing system Alternating current (AC) 50/60 Hz Breaking capacity (Icn) according to IEC Voltage (Ue) Ph/N, Ph/Ph 110 V 240 V Rating (In) 10 to 32 A A A Padlocking device b Used to lock the toggle in the "open" or "closed" position by 4 mm diameter padlock (not supplied). DB Catalogue numbers ic60h2 RCBO P A Width in 9 mm modules C curve Voltage rating (V) Sensitivity (I n) 30 ma N/L1in N/L1out L2in L2out Operating frequency Auxiliaries 110 Rating (In) 240 Rating (In) 10 A A9D A A9D A A9D A A9D A A9D A A9D A A9D A A9D A A9D A A9D Hz Remote tripping and indication, module CA and CA Type Padlocking device (bag of 10 pieces) A9A
4 b IP20 shrouded terminal cage b Test push-button Connection DB PB DB VisiTrip window b Fault tripping is indicated by a red mechanical indicator on the front face VisiSafe contact indication b The green strip is independent from the toggle and provides positive indication of the state of the contacts. DB DB b IP20 shrouded terminal cage b Clip for dismounting b Increased product service life thanks to fast closing independent of the speed of actuation of the toggle. b Remote indication, open/closed/tripped, by optional auxiliary contacts. 14 mm 6.5 mm Type Rating Tightening torque Copper cables DB Rigid DB Flexible 5.5 mm PZ2 N in and L in 6 to 45 A 3.5 N.m 1 to 25 mm 2 1 to 16 mm 2 L out and N out 2 N.m 1 to 16 mm 2 1 to 10 mm 2 PZ2 13 mm 75
5 Technical data Main characteristics ic60n RCBO ic60h RCBO ic60h2 RCBO Insulation voltage (Ui) 400 V AC Rated impulse withstand voltage (Uimp) 4 kv Rated residual operating current (I n) 30 ma 30, 100 ma 30 ma Thermal tripping Reference temperature 50 C Temperature derating See module CA Limitation class 3 Surge current withstand (8/20 μs) without tripping 250 Â Rated nominal breaking capacity (Icn) 6,000 A 10,000 A 10,000 A Phase/earth rated residual breaking and making capacity (I m) 6,000 A 7,500 A 7,500 A Additional characteristics Degree of protection Device only IP20 Device in modular enclosure IP40 Endurance (O-C) Electrical 5,000 cycles Mechanical 20,000 cycles Operating temperature -15 C to 60 C Storage temperature -40 C to 85 C Tropicalisation Treatment 2 (relative humidity: 95 % at 55 C) DB DB DB Clip on DIN rail 35 mm. DB IP20 IP40 Installation on Fishbone. Indifferent position of installation. 76
6 Weight (g) ic60n RCBO 205 ic60h RCBO 205 ic60h2 RCBO 332 Dimensions (mm) DB ic60n RCBO, ic60h RCBO ic60h2 RCBO 77
C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)
DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables
More informationict contactors EN 61095, IEC 1095 Interference
ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated.
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationDSE201, DSE201 M Compact design with enhanced protection
DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection
More informationLow voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016
Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave
More informationType of surge arrester
ipf surge arresters Type 2 or 3 LV surge arresters The ipf multi-pole single-piece surge arrester range is adapted for earthing systems: TT, TN-S,. Type 2 surge arresters are tested with a 8/20 µs current
More informationC60 multi-standard range
Low voltage C60 multi-standard range Catalogue 07/2014 C60 multi-standard range Summary Presentation Panorama of the C60 multi-standard range CM907017E 2 Circuit protection Circuit breaker C60 UL 489
More informationDX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationSurge Protection Devices Ex9UE2
Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,
More informationSupplementary Circuit Protectors Type GSB63
Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up
More informationRB60 RANGE. Miniature circuit breakers
RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection
More informationRCDs RCBOs MCBs Isolating Switches Switchboards
RCDs RCBOs MCBs Isolating Switches Switchboards 1300 722 275 F: 1300 738 717 RCD 4 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable
More informationHorizontal distribution busbar HX 3 80/125 A plug-in
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Horizontal distribution busbar HX 3 CONTENTS Pages 1. Description... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation -
More informationElectrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA
for ic60, iid, idpn Vigi, isw-na, RCA and ARA b The electrical auxiliaries are combined with ic60 circuit breakers, iid residual current circuit breakers, remote tripping switch disconnector isw-na, RCA
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationLow voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.
Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation
More informationRedline. Extensions. Display contacts. Function S. Display contact CA. Function. Add-on Devices T3.2
Redline Extensions All MCB s (except G20), RCCB s (except Delta B) & RCBO s are designed to accept the same family of extensions. Main device ON Normal working status Addon Devices The extensions intended
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationControl elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.
On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationVEO. V2UF230V10 Art.Nr.: TECHNICAL DATA
Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after
More informationVEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA
4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationAutoprotected Surge Arresters New OVR Plus range
Autoprotected Surge Arresters New OVR Plus range A complete solution with the OVR PLUS range Thanks to its continuous innovation on surge protection, ABB improves constantly its offer by launching on the
More informationMinimum space, maximum protection DS203NC: 3P+N RCBOs in 4 modules
Minimum space, maximum protection DS203NC: 3P+N RCBOs in 4 modules The complete evolution DS203NC and ABB modular range: absolute integration ABB is present on the market of electric installations with
More informationRE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationRE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time
More informationVEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA
Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationRE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output
Characteristics off-delay timing relay - control - 1 s..100 h - 24..240 V - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationMotor protection circuit breakers
R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,
More informationResidual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008
Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,
More informationElectronic timer CT-ERD.12
2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationElectronic timer CT-ARS.11
2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact
More informationmcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches
NEW P. 4 RX3 MCBs 63 A 4500 & 6000 prong type busbar MCBs, RCDs, add-on modules & accessories P. 9 DX3 RCBOs 63 A 6000 / 10 ka AC, A & Hpi type prong & fork type busbar P. 16 DX3 MCBs 63 A 50 ka mcbs,
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital Line-voltage independent, all-current sensitive RCCB for fault or additional protection with additional digital features System Monitoring: Preventive
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationElectronic timer CT-AHD.22
2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationMotor Controllers AC Semiconductor Motor Controller Type RSHR MIDI
otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush
More informationDatasheet - SRB 301LC/B-24V
27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit
More informationPRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters
Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More informationC C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description
CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated
More informationNF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationTeSys protection components
Description, characteristics -pole electronic thermal overload, TeSys LR9D0, 0, 08, and LR9D0S DB8880.eps 7 / & 8 Description LR9D0, 0, 08 and self-powered electronic thermal overload are designed for
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationDatasheet SRB301ST 24V (V.2)
26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationDatasheet - SRB 402EM-24V
Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor
More informationAThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.
www.moeller.co.uk MCCB Panel Boards 400A / 630A / 800A Product Catalogue and Selection Guide MCCB Panel Boards Moulded Case Circuit Breakers and Accessories XBoard Consumer Units XPole Miniature Circuit
More informationElectronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationMotor Controllers AC Semiconductor Motor Controller Type RSHR MIDI
otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush
More informationRE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O
Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts type
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationBulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications
Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals
More informationElectronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact The CT-ERS.12 is an electronic timer from the CT-S range with ON-delay and 10 time ranges. All electronic timers from the CT-S
More informationElectronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts The CT-ARS.21 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationCombined RCD/MCB Devices FRBmM, 1+N-pole
Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current
More informationTechnical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit
Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand
More informationVoltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationRE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O
Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/ O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing
More informationElectronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet
2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication
More informationPan assemblies and installation accessories
Contents Section 10 Pan assemblies and installation accessories SP&N pan assemblies 124 SP&N door and cover 124 TP&N pan assemblies 125 TP&N door and cover 125 Multiclip busbar and Polybloc 126 Comb busbars
More informationElectronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact The CT-EBD.12 is an electronic time relay with the function flasher starting with ON. It is from the CT-D range.
More informationAdd-on Residual Current Protection PBSM MW
SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 36 Add-on Residual Current Protection PBSM MW By combining this device with a top-quality miniature circuit breaker of type PLS. (except PLSN) a top-quality RCBO
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationElectronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts The CT-ARS.21 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationElectronic timer CT-ERS.21
2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width
More informationThe right solution for every home
Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More informationthe Santon FCS-type switch Disconnect Superior Switch Solutions
the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal
More informationSentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification
TD255 Consumer Units and Enclosures Standards and approvals All Sentry consumer units are designed to fully comply with the requirements of BS EN 60439-3. Weatherproof enclosures are designed to fully
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationW DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N
W DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N Seybelgasse 13, A - 1230 Wien, TELEFON +43 1/866 85-0 E-MAIL info@schrack.at, INTERNET www.schrack.at PAGE 1/26 W RCBO COMBINED MCB AND RCCB SERIES
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationPlexPower Factory Sealed Panelboard Increased Safety
Applications The IEC PlexPower factory sealed panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More information