NMEA Expander. Operation And. Installation Manual

Similar documents
16-Channel Digital Input Termination Card 24Vdc

16-Channel Digital Input Termination Card 24Vdc

16-Channel Input Digital Input Termination Card

File (19 inches) for RS3 FIC I/Os (AI/AO) migration toward a new system

Flexible 32-bit PCI to MiniPCI Express Adapter

rdczbk User Manual ZigBee to RS-232 / RS-485 Converter

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

UF-3701 Power Board Construction Guide

PMDX Axis Breakout/Motherboard for Gecko Stepper Motor Drivers User s Manual

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL

I/O Expansion Module Installation & Reference

Audio Input Card Installation Instructions

IBS ST (ZF) 24 BK LB-T

CPT-COM-U Card. TTL Serial USB Isolated Interface Board. Technical Brief

I/O Expansion Board. Control Made Simple

8-Channel Relay Output Board Via I 2 C, USB Protocol P/N KA-I2C-8-RL-PWR-TH. I2C-USB-Relay8. User Manual. Page 1 / 17

Bus Connection Unit 560BCU04

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

GW1101 Rev Introduction. DASH7 - IP Gateway for Industrial Applications. Applications. Description. 868MHz / 915MHz.

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

SPECTRA ENGINEERING PTY LTD

8-Channel Relay Output Board Via I 2 C Protocol. I2C-Relay8

PA ROUTERS. The following criteria can be applied when choosing the network transition:

MANUAL NLMAINUNIT-2U-E & NLPDU. Remote power management and surge protection for IT equipment. Netshield (Pty) Ltd

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

FLEX Ex Spring Clamp Terminal Base

Product Manual. TZ Centurion Port Links. TZ Centurion Port Link 7101CL TZ Centurion Multi Port Link 7105CL

CPCI-PS24 24V-Power Supply

VS. 4 Game Selector INSTALL GUIDE

Power Enclosure Components

Thermoelectric Cooler Controller TED1000

Submittal Data Sheet WAGO Node for itm

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

OPERATION AND USE OF THE ANIMATICS EXTERNAL LCD DISPLAYS LCD2X20 (two line x twenty character display) LCD4X20 (four line x twenty character display)

is then retained absolutely without interruption.

Expert I/O 1000 Hardware User Manual

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

PCI EXPRESS EXPANSION SYSTEM USER S MANUAL

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

INTELLIGENT DOCKING STATION USERS MANUAL

EP-ELVCTL Elevator Control (NION-16C48M)

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

USER S MANUAL Power Supply for Backplane Vdc

Rev. A. ANC Series RS-485/RS-422 Synchronous Clock Display. Antona Corporation (818) URL:

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

APMC4110 POWERED PMC CARRIER STANDALONE PCI INTERFACE MODULE

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW

Proposal for SAS 2.1 Specification to Enable Support for Active Cables

State of New York. Model 242-NY. DC Isolator Unit Operations Manual THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE MODEL 242-NY DC ISOLATOR UNIT.

Dolphin DXE410 Expansion Chassis

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

TPCE260. PCI Express PMC Carrier. Version 1.0. User Manual. Issue August 2014

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Anybus CompactCom Starter Kit REFERENCE GUIDE

TECHNICAL PRODUCT DATASHEET

Installation Manual. Alpha 4000 RGB Signs. Before you begin

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

HE104 Version V11. High Efficiency Vehicle Power Supply. DC to DC Convertor. Technical Manual. Manufactured by. Tri-M Technology

Moog Components Group Submux1 Manual December 7, 2009

CONTROL CABINET KR C1 A. Technical Data. KRC1A_Tech.Dat en. 1of 11

OPERATION MANUAL. Decision Group Inc. SMARTLAB USB 16 CHANNELS RELAY OUTPUT 16 CHANNELS PHOTO ISOLATOR INPUT BOARD

PAS 9715/AO ENGINEERING SPECIFICATION

DS-MPE-SER4OPT. PCIe MiniCard 4 Port Opto-isolated Serial Module Rev A.01 September 2013

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

MODEL USB-AO16-16A 16-Bit, 16-Channel Analog Output USB Module USER MANUAL

I / O Expander. Instrument for torque control ASL 11/17

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

AHD-RB6 Electronic Circuit Breaker (ECB) Type C

MODEL USBP-II8IDO4A. 8 ISOLATED DIGITAL INPUTS, 4 SOLID STATE RELAY OUTPUTS and 2 16-BIT ANALOG INPUTS USER MANUAL

PCIE FIVE SLOT EXPANSION SYSTEM USER S MANUAL

Butterfly Laser Diode Mount

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Conference Table Connectivity Box for A/V - 4K

Remote Bus Extender Slave Module

MODELS PCIe-DIO-48S PCIe-DIO-48 PCIe-DIO-24S. PCI Express 48 Channel Digital I/O Card with Change of State Detection USER MANUAL

icore Kiosk system Installation Guide

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Thunderbolt 3 to USB 3.1 Controller Adapter - 1x USB-C, 3x USB-A

RACEway Products. RACEway Test Adapter (RTA-S-2 & RTA-D-2) User s Manual RevB

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

DUAL LASER PACK & CONTROLLER USERS MANUAL

7-Port Charging Station for USB Devices

AIAO U CompactPCI Analog I/O Card. User Manual. 13 Altalef St. Yehud, Israel Tel: 972 (3) Fax: 972 (3)

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

FOR VISUAL CARD READER / WRITER. Installation Guide & Specifications

Cardkey S300 Enclosures

MODEL USBP-DIO16RO8. DIGITAL INPUT/OUTPUT BOARD w/8 ELECTROMECHANICAL RELAYS USER MANUAL

PHOENIX CONTACT - 05/2007

PAS 9406/AMP ENGINEERING SPECIFICATION

Datasheet BT85x Series Development Kits

ERICSSONZ LBI-38566B MAINTENANCE MANUAL AUDIO BRIDGE MODULE 19D902458G1 TABLE OF CONTENTS

Xtreme/PSU Isolated User Manual

Transcription:

NMEA Expander Operation And Installation Manual XXXXXX_20130331 Revision B0 Syberg Maritim

1. OPERATION AND CONFIGURATION... 3 SYSTEM SUMMARY... 3 INPUT POWER SUPPLY, D CONFIGURATION... 4 INPUT POWER SUPPLY, SA CONFIGURATION... 4 Fig. 1.1 Input Power Terminal and LEDs... 4 SIGNAL TERMINALS, D CONFIGURATION... 5 SIGNAL TERMINALS, SA CONFIGURATION... 7 Fig. 1.2 PCB Components... 9 Fig. 1.3 Signal Input and Distribution...10 2A. INSTALLATION, NMEA_D...11 MECHANICAL...11 Fig. 2.1 NMEA Changeover Unit Expander Installation...12 2B. INSTALLATION, NMEA_SA...13 MECHANICAL...13 Fig. 2.2 NMEA Expander Dual Board Box Installation...13 Fig. 2.3 NMEA Expander Rail Support Installation...14 3. NMEA EXPANDER MAINTENANCE...15 USER MAINTENANCE...15 POWER SUPPLY AND SUPERVISION...15 TROUBLE SHOOTING...15 SERVICE...15 Fig. 3.1 Power Supply Schematic...16 Fig. 3.2 NMEA Inputs Schematic...17 Fig. 3.3 Channel 1 Outputs Schematic...18 Fig. 3.4 Channel 2 Outputs Schematic...19 4. SPECIFICATIONS...20 DIMENSIONS...20 FUNCTIONAL PROPERTIES...20 ENVIRONMENTAL...20 2 of 20 20130325 Rev. B0

1. Operation and Configuration System Summary Depending on the configuration, the Syberg NMEA Expander can be used in several environments. With configuration NMEA_D (Daugther Board), it is used as an expansion plug-on module to the Changeover Unit. It fits directly onto the male headers of J106, J206, J107, J207 and the bottom 4 positions of J500. NMEA 0183 inputs connected to this board are distributed onto input terminals of the Changeover Unit. This plug-on module replaces an external NMEA Expander and greatly simplifies installation. With configuration NMEA_SA (Stand Alone), It is used as a configurable, Stand Alone NMEA Expander. Standard, pluggable terminals are used on the component side for terminals XJ106, XJ206, XJ107, XJ207 and XJ500. +24 V is supplied to XJ500 and the board may be operated as 2 galvanically separate systems. The possible configurations are: 4 * 1 input to 4 outputs (2 in each galvanic system). 2 * 1 input to 8 outputs (1 in each galvanic system). 1 * 1 input to 16 outputs (The galvanic systems are interconnected). If interconnected to a second NMEA_SA an additional configuration is possible: 1 * 1 input to 32 outputs All IMO requirements are met or exceeded 3 of 20 20130325 Rev. B0

Input Power Supply, D Configuration In the NMEA_D configuration, NMEA Expander takes +24V from J500 of the Changeover Unit. Half of the Expander (Channel 1, +24V Supply 1) is supplied from J500-13,14 and the other half (Channel 2, +24V Supply 2) from J500-13,14. See fig. 1.1 LD100 and LD102 indicate presence of the input supplies. The Expander blocks the view of the corresponding LEDs on the Changeover board, LD107, LD106 respectively, and this is indicated in the component text. Each of the +24V supplies have their own +5V regulator for supply to the NMEA circuitry. Input Power Supply, SA Configuration In the NMEA_SA configuration +24 V is supplied to XJ500. Two separate supplies may be connected to XL500-13,4 and XJ500-15,16 for galvanically divided setups. If only one galvanic system is required, +24 V may be connected to either XL500-13,4 or XJ500-15,16 and the two supplies may be interconnected by JP100. Two jumpers are required to connect +24V and the separate Grounds (1-2 and 5-6) See fig. 1.1 LD100 and LD102 indicate presence of the input supplies. Each of the +24V supplies have their own +5V regulator for supply to the NMEA circuitry Fig. 1.1 Input Power Terminal and LEDs 4 of 20 20130325 Rev. B0

Signal Terminals, D Configuration Input Terminals J600 and J601 are the NMEA 0183 inputs. For flexibility, it is possible to supply different input signals to each separate output terminal source pair (group). Decide how you want to feed the groups. Each of the groups has 2 separate source inputs, one for J10x and one for J20x. (2*4 outputs from 2 input sets). If one *8 Expander is required for each Channel, the same inputs are used for both Groups, and only J600 is required. Interconnection to Group 2 is carried out with the jumpers J200 and J201 in the ON position, interconnecting pins 1-2 on both jumpers. If two individual *4 Expanders are required for each Channel, put both jumpers in the OFF position (connect pins 2-3), and supply separate input signals to J600 and J601. Group 1: Source 1: J600-1, 2: LD200 Source 2: J600-3, 4: LD202 Group 2: Source 1: J601-1, 2: LD201 Source 2: J601-3, 4: LD203 Each input signal may be monitored on separate LEDs as indicated on Fig. 1.2 below. Input Signal LEDs are on when current flows through the input, i.e. they flicker on when data is present. Jumpers JP100 and JP202 should be kept in the OFF position (connect pins 2-3 and 4-5) for this configuration. See figures 1.2 and 1.3 5 of 20 20130325 Rev. B0

Output Terminals The Output Terminals are plugged directly into the respective inputs on the supporting Changeover Board. Each output signal is monitored by a LED, located below the two rows of output terminals and marked accordingly. Group 1: Source 1: J600-1, 2 expands on (X)J106 Source 2: J600-3, 4 expands on (X)J206 Group 2: Source 1: J601-1, 2 expands on (X)J107 Source 2: J601-3, 4 expands on (X)J207 Output Signal LEDs flicker on when data is present at the Output. 6 of 20 20130325 Rev. B0

Signal Terminals, SA Configuration Input Terminals J600 and J601 are the NMEA 0183 inputs. For flexibility, it is possible to supply different input signals to each separate output terminal source pair (group). Decide how you want to feed the groups. 1*16 Expander: If one *16 Expander is required, the same inputs are used for both channels and both Groups, and only J600 1-2 is required. Interconnection between Groups is carried out with the jumpers J200 and J201 in the ON position, interconnecting pins 1-2. Interconnection between Channels is carried out with the 2 jumpers of JP202 in the ON position, interconnecting pins 1-2 and 5-6. 2*8 Expanders: If two *8 Expanders are required, the same inputs are used for both channels, and only J600 is required. Interconnection between Groups is carried out with the jumpers J200 and J201 in the ON position, interconnecting pins 1-2. The 2 jumpers of JP 202 should be kept in the OFF position, interconnecting pins 2-3 and 4-5. 4*4 Expanders: If four individual *4 Expanders are required, put all jumpers, J200, J201, J202, in the OFF position (connect pins 2-3 and 4-5), and supply separate input signals to J600 and J601. Connect one or two Power Supplies as desired, see Operation, Input Power Supply, SA Configuration. See figures 1.2 and 1.3 Group 1: Source 1: J600-1, 2: LD200 Source 2: J600-3, 4: LD202 Group 2: Source 1: J601-1, 2: LD201 Source 2: J601-3, 4: LD203 7 of 20 20130325 Rev. B0

Output Terminals Each output signal is monitored by a LED, located below the two rows of output terminals and marked accordingly. Group 1: Source 1: J600-1, 2 expands on (X)J106 Source 2: J600-3, 4 expands on (X)J206 Group 2: Source 1: J601-1, 2 expands on (X)J107 Source 2: J601-3, 4 expands on (X)J207 Output Signal LEDs flicker on when data is present at the Output. Interconnection of two NMEA Expander Boards 1*32 Expander: If one *32 Expander is required, two Expander Boards are needed. Each Board is connected as *16 configurations, the same inputs are used for both channels and both Groups, and only J600 1-2 is required. Interconnection between Groups is carried out with the jumpers J200 and J201 in the ON position, interconnecting pins 1-2. Interconnection between Channels is carried out with the 2 jumpers of JP202 in the ON position, interconnecting pins 1-2 and 5-6. In addition, the two Boards are interconnected with a cable between the two Boards, using connectors J200 or J201. 8 of 20 20130325 Rev. B0

Fig. 1.2 PCB Components 9 of 20 20130325 Rev. B0

Fig. 1.3 Signal Input and Distribution 10 of 20 20130325 Rev. B0

2A. Installation, NMEA_D The NMEA Expander is plugged directly onto the Changeover Unit in the lower right corner, mating directly J106, J206, J107, J207 and the bottom 4 positions of J500. NMEA Input Signals are connected to J600 and J601. Mechanical Unscrew the two M4 screws along the right edge of the Changeover board that will be covered by the NMEA Expander. Replace these screws by the supplied M4 23 mm ENINT standoffs. On the Changeover Board, remove the pluggable screw terminals on J106, 107, 206 and 207. Also remove the pluggable screw terminals on J500-13, 14, 15, 16. Seat the Expander onto the corresponding headers and press down until the connectors mate properly. Fix the NMEA Expander Board with the previously removed M4 screws onto the standoffs. See figure 2.1 11 of 20 20130325 Rev. B0

Fig. 2.1 NMEA Changeover Unit Expander Installation 12 of 20 20130325 Rev. B0

2B. Installation, NMEA_SA The NMEA Expander is fitted into a dedicated Box for wall mounting or a Support for rail mounting within a desk. NMEA Input Signals are connected to J600 and J601. Mechanical Fit the NMEA Expander Stand Alone unit in an appropriate space using the necessary Box or Support. The Wall Mounting Box may be used for 2 Expander Boards. The Rail Mounting Support carry one Expander Board each. Take care to make proper space for cable connections. See figure 2.2 and 2.3 Fig. 2.2 NMEA Expander Dual Board Box Installation 13 of 20 20130325 Rev. B0

Fig. 2.3 NMEA Expander Rail Support Installation 14 of 20 20130325 Rev. B0

3. NMEA Expander Maintenance User maintenance No user maintenance is required. Power Supply and Supervision Power Input There are two 24V inputs with on XJ500. The inputs are connected to the separate internal +24V power buses through diodes and auto resettable 140 ma PolySwitch fuses. The two +24V buses are monitored with LD100 and LD102 respectively. Each +24V bus feeds individual +5V regulators and the outputs of these are monitored by LD101 and LD103 respectively. Trouble Shooting Symptom Cause Remedy Signal missing on single Output Signals missing on Channel 1 (XJ106, XJ107) Signals missing on Channel 2 (XJ206, XJ207) Signals missing on Group 1 or 2 Output shorted Output Driver Defective Defective input power 1. Missing Power Input XJ500-15,16. Defective input power 2 Missing Power Input XJ500-13,14. Missing input signals Remove Short and observe Output LED Replace Board Check input power 1 LD100 (24V), LD101, TP100 (5V) Check input power 2 LD102 (24V), LD103, TP101 (5V) Check corresponding input signal LEDs Service All service requests should be made to the local SYBERG representative. Adjustments and repairs should only be performed by qualified service engineers. Unqualified repair attempts will void the warranty. 15 of 20 20130325 Rev. B0

Fig. 3.1 Power Supply Schematic 16 of 20 20130325 Rev. B0

Fig. 3.2 NMEA Inputs Schematic 17 of 20 20130325 Rev. B0

Fig. 3.3 Channel 1 Outputs Schematic 18 of 20 20130325 Rev. B0

Fig. 3.4 Channel 2 Outputs Schematic 19 of 20 20130325 Rev. B0

4. Specifications Dimensions NMEA Expander Unit Height 150 mm Width 107 mm Depth 35 mm Weight approx. 0.1 kg Functional Properties NMEA Outputs NMEA Inputs 8 (4 + 4) NMEA0183 Outputs. Indicator LEDs for all Outputs. 2 + 2 galvanically separated opto-coupler inputs. Environmental Supply voltage: 24V DC (20-32V) Power consumption: Maximum 1.5W at 24V Operating temperature: 0-40 C Storage temperature: -20 - +70 C Humidity: 10-90% relative, no condensation. 20 of 20 20130325 Rev. B0