BNI IOL K023 BNI IOL K023. User s Guide

Similar documents
BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL Z012. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z012. User s Guide

BNI IOL-104-S01-Z012-C02

BNI IOL A027 BNI IOL A027

BNI USB A501. User s Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z BNI IOL Z037 BNI IOL Z Smart Light User s Guide

BNI IOL K006. IO Link Sensorhub digital User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI IOL-75x-Vxx-K007 Valve Plug Short Guide

BNI IOL Z036 BNI IOL Z036

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI USB A501. USB IO-Link Master User's Guide. english

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI EIP E002. EtherNet/IP IP69 modules User's Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI EIP Z016 IP67 Modules, 16 In-/Outputs User s Guide

BNI DNT Z001 DeviceNet IO-Link Master User s Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BIS L x-07-S4

BNI EIP Z040. IP67 Module 4 IO-Link Class A and 8 in- and outputs 4 IO-Link Class B and 4 inputs User's Guide

BNI PNT Z015 BNI006C. IP67 Module User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005. User s Guide

BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 modules User's Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI PNT Z031 BNI PNT Z IP67 Module User s Guide

BNI EIP Z015. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

BNI CIE Z015 BNI CIE Z015 BNI CIE Z015 BNI CIE Z015. CC-Link IE Field Standard I/O Modules User's Guide

BNI EIP R015 BNI EIP R015. EtherNet/IP IP67 modules User's Guide

BNI CCL Z001. CC-Link IO-Link Master User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI CIE Z015 BNI CIE Z015. CC-Link IE Field IO-Link Master User's Guide

BNI EIP Z015 IP67 Modules 16 Inputs User s Guide

Balluff Network Interface / CC-Link BNI-CCL Z001 BNI CCL Z001. Extended User Manual. 1

BNI EIP Z015-C06. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

BTL6-A_10-M -A1-S115. Data Sheet. english

BNI EIP Z015 BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 Modules User s Guide

BNI CCL Z001. CC-Link IO-Link Master User s Guide

User's Manual. english

BNI EIP Z015-C06. EtherNet/IP IP67 modules User's Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

SCHMIDT Sensor interface PROFIBUS Instructions for use

BNI PNT Z063. IP67 Module User's Guide

BIS M _ 0 _ -07-S4 BIS M _ 0 _ -07-S4

2-Axis Counter BDD 622

BIS L x-07-S4

BNI PNT Z033. IP67 Module User s Guide

BTL5-A/C/E1_-M- -SF-F User's Guide

BTL6-V1 _ E-M -A1-S115 User's Guide

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

BIS M _ -07-S4 BIS M _ -07-S4

BTL6-V11V-M -A1-S115 User's Guide

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

BIS V-6102 PROFIBUS. Technical Description, User s Guide. english 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

AXL E IOL AO1 U M12 R

Hardware Manual RM CANview Gateway

CMC III Universal Sensor

GFK-2415A March Type of sensor connection

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Profibus IO Modules User's Guide

BIS M xx-ST4 PROFINET

BMF400 Input/output module

Single-Axis Counter BDD 611

Hardware Manual RM CANview

Hardware Manual RM Display 1001

Fieldbus Independent I/O Modules 4 AI Pt100/ RTD , (/xxx-xxx) Manual

General The Inclination Sensor BSI is an instrument used to control the inclination angle of a reference axis.

BIS L , BIS Z-EL-...

Instruction and Operation Manual

Manual LioN-P - IO-Link Device - I/O Hub

BIS M x-ST4 EtherNet/IP

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

I/O SIGNAL CONDITIONER

RS485 MODBUS Module 8AO

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Profibus I/O Modules BNI PBS Z001 BNI PBS Z001

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Transcription:

BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide

Content 1 Notes 2 1.1. Struture of the guide 2 1.2. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references 2 1.3. Symbols 2 1.4. Abbreviations 2 1.5. Deviating views 2 2 Safety 3 2.1. Intended use 3 2.2. Installation and startup 3 2.3. General safety notes 3 2.4. Resistance to aggressive substances 3 Hazardous voltage 3 3 Getting started 4 3.1. Connection overview 4 3.2. Mechanical connection 4 3.3. Electrical connection 4 3.4. IO-Link interface 4 Connecting the module 4 Module versions 5 3.5. Sensor interface 5 4 IO-Link interface 6 4.1. IO-Link data 6 4.2. Process data / input data 6 BNI IOL-712-000-K023 6 BNI IOL-714-000-K023 6 4.3. Parameter data/ Request data 7 4.4. Errors 7 4.5. Events 7 5 Technical data 8 5.1. Dimensions 8 5.2. Mechanical data 8 5.3. Electrical data 8 5.4. Operating conditions 8 5.5. LED indicators 9 Status LED 9 6 Appendix 10 6.1. Product ordering code 10 6.2. Order information 10 6.3. Scope of delivery 10 www.balluff.com 1

Balluff Network Interface / IO-Link 1 Notes 1.1. Struture of the guide 1.2. Typographical conventions Enumerations Actions Syntax Cross references The guide is organized so that the sections build on one another. Section 2: Basic safety information.. The following typographical conventions are used in this guide. Enumertions are shown in list form with bullet points: Entry 1 Entry 2 Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow. Action instruction 1 Action result Action instruction 2 Numbers: Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00hex). Cross references indicate where additional information on the topic can be found. 1.3. Symbols Note This symbol indicates general notes. 1.4. Abbreviations BNI Balluff Network Interface I-Port Standard input port DPP Direct parameter page IOL IO-Link EMC Electromagnetic compatibility FE Function ground SPDU Service Protocol Data Unit Attention! This symbol indicates a security notice which most be observed. 1.5. Deviating views Product views and illustrations in this user's guide may differ from the actual product. They are intended only as illustrative material. www.balluff.com 2

2 Safety 2.1. Intended use This guide describes the Balluff Network Interface BNI IOL-712/714-000-K023 for the application as peripheral output module to connect analogue sensors. Hereby it is about an IO-Link device which communicates by means of IO-Link protocol with the superordinate IO- Link master assembly. 2.2. Installation and startup 2.3. General safety notes 2.4. Resistance to aggressive substances Hazardous voltage Attention! Installation and startup are to be performed only by trained specialists. Qualified personnel are persons who are familiar with the installation and operation of the product, and who fulfills the qualifications required for this activity. Any damage resulting from unauthorized manipulation or improper use voids the manufacturer's guarantee and warranty. The Operator is responsible for ensuring that applicable of safety and accident prevention regulations are complied with. Commissioning and inspection Before commissioning, carefully read the operating manual. The system must not be used in applications in which the safety of persons is dependent on the function of the device. Authorized Personnel Installation and commissioning may only be performed by trained specialist personnel. Intended use Warranty and liability claims against the manufacturer are rendered void by: Unauthorized tampering Improper use Use, installation or handling contrary to the instructions provided in this operating manual Obligations of the Operating Company The device is a piece of equipment from EMC Class A. Such equipment may generate RF noise. The operator must take appropriate precautionary measures. The device may only be used with an approved power supply. Only approved cables may be used. Malfunctions In the event of defects and device malfunctions that cannot be rectified, the device must be taken out of operation and protected against unauthorized use. Intended use is ensured only when the housing is fully installed. Attention! The BNI modules generally have a good chemical and oil resistance. When used in aggressive media (eg chemicals, oils, lubricants and coolants each in high concentration (ie, low water content)) must be checked prior applicationrelated material compatibility. In the event of failure or damage to the BNI modules due to such aggressive media are no claims for defects. Attention! Disconnect all power before servicing equipment. Note In the interest of product improvement, the Balluff GmbH reserves the right to change the specifications of the product and the contents of this manual at any time without notice. www.balluff.com 3

Balluff Network Interface / IO-Link 3 Getting started 3.1. Connection overview 4 1 2 3 1 Status LED: Supply, Communication 2 Label 3 IO-Link interface 4 Analogue input port Figure 3-1: BNI IOL- -K023 3.2. Mechanical connection 3.3. Electrical connection To avoid long, shielded analogue cables, the BNI IOL-712/714-000-K023 modules should be attached to the analogue unit which has to be connected. No further mechanical attachment is required. The BNI IOL-712/714-000-K023 modules require no separate supply voltage connection. Power is provided through the IO-Link interface by the superordinate IO-Link Master Assembly. 3.4. IO-Link interface IO-Link (M12, A-coded, male) Pin Signal 1 Supply voltage, +24V 2-3 GND, reference potential 4 C/Q, IO-Link Data transmission channel Connecting the module Connect the BNI IOL- -K023 either to an IO-Link Master directly or to an analogue sensor. Connect the male plugs unconnected by using cables. Note A standard 3 wire sensor cable is used for connection to the host IO-Link master. Note A shielded 4 wire sensor cable is used for connection to the analog actuator. www.balluff.com 4

3 Getting started Module versions Module versions Analogue port BNI IOL-712-000-K023 Current input(0-20ma) BNI IOL-714-000-K023 Voltage input (0-10V) 3.5. Sensor interface Analogue input port (M12, A-coded, female) Pin Signal 1 +24V, ma* 2 Current input 0-20mA 1) 3 GND 4 Voltage input 0-10V 2) 1) Only in case of BNI IOL-712-000-K023 2) Only in case of BNI IOL-714-000-K023 * Depending on the IO-Link master, but max. 2A. www.balluff.com 5

Balluff Network Interface / IO-Link 4 IO-Link interface 4.1. IO-Link data BNI IOL-712-000-K023 Data transmission rate COM2 (38,4 kbaud) Frame type 2.2 Minimal cycle time 3 ms Process data cycles 3 ms, at minimal cycle time Prozess data length 2 byte input 4.2. Process data / input data BNI IOL-714-000-K023 Data transmission rate COM2 (38,4 kbaud) Frame type 2.2 Minimal cycle time 3 ms Process data cycles 3 ms, at minimal cycle time Prozess data length 2 byte input BNI IOL-712-000- K023 Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 MSB Analogue Input Current Value LSB - Error Error: 0 - current > 4mA 1 current < 4mA BNI IOL-714-000- K023 Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Analogue Input Voltage Value - - Note The measuring range from 0 21.15 ma (for BNI IOL-712-000-K023) will be shown in 16384 steps. Note The measuring range from 0-10 Volt (for BNI IOL-714-000-K023) will be shown in 16384 steps. www.balluff.com 6

4 IO-Link interface 4.3. Parameter data/ Request data Identification Data DPP Index Index 0x07 0x08 0x09 0x0A 0x0B SPDU Sub- Index Object name Length Range Default value Vendor ID Device ID 2 Byte 3 Byte 0x0378 0x050802 0x050801 0x10 0 Vendor name 7 Byte BALLUFF 0x11 0 Vendor text 15 Byte read only www.balluff.com 0x12 0 Product name 20 Byte 0x13 0 Product ID 7 Byte 0x14 0 Product text 22 Byte BNI IOL-712-000-K023 BNI IOL-714-000-K023 BNI 0041 BNI 0042 Analog current converter Analog voltage converter 0x16 0 Hardware Revision 1 Byte 1.2 0x17 0 Firmware Revision 23 Byte 1.0 Parameter Data - 4.4. Errors Error Code Additional Code Device application error Index not available 0x80 0x11 Device application error Subindex not available 0x80 0x12 Device application error Value out of range 0x80 0x30 4.5. Events Class / Qualifier Mode Type Instance Appears Error AL Device Hardware 0xC0 0x30 0x03 0x5000 0xF3 Disappears Error AL Device Hardware 0x80 0x30 0x03 0x5000 0xB3 Supply 0x010 0 Supply 0x010 0 Code ( high + low) Supply low voltage 0x0010 0x5112 Supply low voltage 0x0010 0x5112 U2 = Supply + 24V 0x0002 U2 = Supply + 24V 0x0002 www.balluff.com 7

Balluff Network Interface / IO-Link 5 Technical data 5.1. Dimensions Figure 5-1: Dimensions BNI IOL-...-K023 5.2. Mechanical data Housing materials Plastic, Macromelt 6208 IO-Link port M12, A-coded, male I-port M12, A-coded, female Enclosure rating per IEC 60529 IP 67 (only when plugged in and threaded in) Dimensions (W x H x D in mm) 40 x 50.4 x 14.2 Weight ca. 50 g 5.3. Electrical data Operating voltage 18...30.2 V DC, per EN 61131-2 Ripple < 1% Current draw without load <= 30 ma Resolution 14bit Sampling rate 3ms 5.4. Operating conditions Operating temperature -5 C... 70 C Storage temperature -25 C... 70 C www.balluff.com 8

5 Technical data 5.5. LED indicators LED 1: Communication LED 2: Supply Figure 5-2: LED indicators Status LED BNI IOL-71x-000-K023 LED Indicator Function LED 1 Green / Green flashing Communication error / Communication ok LED 2 Green / Green flashing Supply sensor & module ok / Undervoltage www.balluff.com 9

6 Appendix 6.1. Product ordering code Balluff Network Interface IO-Link interface Functions 712 = Current input 0-20mA 714 = Voltage input 0-10V Versions 000 = Standard design BNI IOL-71x-000-K023 Mechanical design K023 = Plastic housing, Hotmelt Bus connection and voltage supply 1xM12 male, 4-poles, external thread Analogue port: 1xM12, female, 4-poles, internal thread 6.2. Order information Order code Material number Product ordering code BNI0041 213978 BNI IOL-712-000-K023 BNI0042 213979 BNI IOL-714-000-K023 Label color Red (RAL5015) Blue (RAL3020) Printing IN or OUT I I 6.3. Scope of delivery BNI IOL- -K023 consists of the following components: IO-Link module User s guide www.balluff.com 10

www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Deutschland Tel. +49 7158 173-0 Fax +49 www.balluff.com 7158 5010 balluff@balluff.de Nr. 920741-726 E 03.126846 Edition G18 Replaces Edition F18 Subject to modification.