DSC POWERSERIES NEO INTEGRATION. This application note will explain how to setup the DSC PowerSeries NEO integration on a KT-400 or a KT-1-M

Similar documents
DSC PowerSeries Neo Integration

DSC MAXSYS INTEGRATION THROUGH A KT-400 CONTROLLER

Release Notes. DN / Version 4.03

exacqvision DSC PowerSeries Neo integration

Connect Alarm app App operation quick guide

New Product Announcement

Pro-Watch 3.8 Eco System Galaxy Dimension Integration Guide

Exacq Mobile. User Manual 9.2. (Updated March 9, 2018)

M2M Services. M2M Smartphone Application Overview v.2.0

Avantis AXI WEB SERVER MODULE USER MANUAL

WebStation User Manual

EntraPass WebStation. User Manual DN

exacqvision Kantech - Client Integration Guide

Exacq Mobile. User Manual. September 2018 Version 9.6

Developer s Guide. PC54O1 Serial Interface Module Version 1.0

New Product Announcement EntraPass v7.10/7.11 Software

New Product Announcement EntraPass v7.10 Software

Release Notes Access Control and Security Management Software

SOFTWARE VERSION 3.10

5.5 AS Layout. GeoVision Technical Handbook 77

SOFTWARE VERSION 3.20

INSTALLER S GUIDE. Activating a DSC Self-Contained System with no Gateway for HomeControl Service (Impassa) Topics: Daniel Rosales [ address]

Understanding Door Configuration

TouchOne Mini User s Guide

MG/SP Series (V4.9/V5.1) What s New

NOTE: This integration applies only to the Bentel Access Control Panel/Keypad equipment with firmware version 3.50 or later.

TCS Access Control System Cheat Sheet

Total Connect 2.0 Online Help

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules

New Product Announcement

CONCEPT 3000/Access 4000 User Manual UK Supplement

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): MAXSYS Series

S P E C I A L E D I T I O N E N T R A P A S S TM

User Guide. K V1 7/05 Rev A

Honeywell Total Connect enables notifications and control via the Web, , or Phone from a Remote Location

Bosch solution 6000 cheat sheets

Digiplex EVO High Security and Access System What s New EVO192 V2.7

Wednesday, October 07, WebBrix. Admin Guide

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

High Security and Access System EVO48 V2.1 EVO192 V2.1

Quick Reference Guide Quick Reference Guide. Integra32. Quick Reference Guide. RBH Access Technologies Inc. RBH Access Technologies Inc.

C O R P O R A T E E D I T I O N E N T R A P A S S TM

Bosch Intrusion Panel Integration Guide

USER GUIDE. for ios Version 1. alula.net ALULA 1

Installation Guide. ZKAccess CLASSIC 3.5. www. zkaccess.com

Configuring Honeywell Vista Alarm Panels Using the HSIM Interface Module Integration Release Notes

Zipato RFID Keypad Setup

DSC programming for the Alexor and Impassa

User Guide. Connect2Go User Guide rev1.0 PO Box 3382 Station Main, Meaford Ontario N4L 1A5 T: (+1)

FSA-CU Configuration Utility Programming Guide

LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER)

2 IDS LCD Keypad User Manual C Issued March 2009

G L O B A L E D I T I O N E N T R A P A S S TM

Access Control and Security Management Software Release Notes

manager IP board 1 app guide / IP Board

2015/09/24. M-Touch

USER MANUAL. Disclaimer

C24 Installation and Activation

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

Keypad LCD (software version 3.10) CA-10 plus

ADT Pulse Mobile App Settings

Configuring Door and Device Templates

New Account Creation. 2. Launch the CarLink app. from your phone s application list. 3. Enter a name for the vehicle.

PCX 46 App User Manual

RK-LINK TM Version 2.x Instructions

GV-AS200 Controller. Hardware Installation Guide

Installation Instructions

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

SK-NET. Version 2. Installation and Operating Manual

Product Overview. Revision 1.3

CITRIX NAVIGATION & ACCESSING myhr

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

Colour Graphic Terminal User Manual. Rev 3.1

Set Up with Microsoft Outlook 2013 using POP3

Virtual Keypad App Help Last update: 2017/02/02

Telephone and Reporting Setup in ElkRP

Update: Protection One OnLine Access now also offers the ability to make changes or additions to contacts on your account.

USER GUIDE. for Android Version 1. alula.net ALULA 1

Total Connect User Guide K /09 Rev. C

INT-TSI Brief User Manual

Ethernet communication module ETHM-1 Plus

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

Antipassback, Parking and Access Areas. Technical Support Engineering Rosslare Security NA For more information please see

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

SmartLock Pro Plus OPERATOR GUIDE

Setting up Virdi integration with Paxton Net2 Server

Modules Programming Guide

PROGRAMMING HELP GUIDE

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Rins 160 Issue 2

Intelligent 4 Door Access Module Programming

Integra32. Quick Reference Guide. Step 1: Install the Software. Installation from CD

EC-11 Ethernet Converter

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401

TM50 Touch Intuitive Touchscreen

IPassan Installation guide

TruVision DVR 60 Quick Start Guide

1. Content of the Box

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Access Control Unit User s Guide

Transcription:

DN NUMBER HERE DSC POWERSERIES NEO INTEGRATION This application note will explain how to setup the DSC PowerSeries NEO integration on a KT-400 or a KT-1-M Minimum Requirements: EntraPass Special, Corporate, Global Edition 6.03.54 o With Global Edition only supported with Multi-site Gateway Kantech Controller: o KT-400 Firmware 1.16 o KT-400 rev1 Firmware 1.22 o KT-1-M Firmware 1.02 DSC (minimum): o Neo alarm Panel firmware 1.10.1.55 Verify firmware at menu [900]-[000] o TL280R or TL2803GR or 3G2080R firmware 4.10.4.29 Manufactured after date 6/23/15 Verify firmware at menu [900]-[460] o Neo HS2LCD Keypad firmware 1.10.1.85 Verify firmware at menu [900]-[001] Connection: NEO Configuration: Using the DSC PowerSeries Neo Keypad: 1. Enable the TL280R, TL2803GR, 3G2080R settings: a. [*8]-[5555], [382], Use arrows to scroll to [5] > Alternate Comm ->Y b. [*8]-[5555], [401], Use arrows to scroll to [7] > Altcom DLS Enb ->Y 2. Enable the RS-232 settings: a. [*8]-[5555],[851],[663] > Ensure only bits 1 and 5 are ON 3. Enter Incoming Encryption key in EntraPass a. [*8]-[5555],[851],[651] i. Capture the first 8 hex values and enter in EntraPass 4. Enter Outgoing Encryption key in EntraPass

EntraPass Setup: a. [*8]-[5555],[851],[652] i. Capture the all 8 hex values and enter in EntraPass 1- For Virtual Zones only: (if not go to step 2) a. Go to Options tab and select System Parameters window. b. On the left choose Integration and click on Add and choose DSCPowerSeriesNeoKT400Serial.dll downloaded from www.kantech.com (password required): 2- Go to the Devices tab and select the Integrated Panel button. a. Click on the New button and name the device accordingly. b. In the Connection Type drop down list, select DSC PowerSeries NEO, KT-400 Serial connection. c. In the Panel model drop down list, select the type of panel you have. Click new. Select the appropriate Connection type and Panel model. Click here to open a configuration form

d. Click the Click here to open a configuration form button, enter the master code in the Master code textbox. NOTE: This code will be used for receiving the programming and updating the alarm panel with the new user codes. The default Master code in a DSC intrusion panel is 1234. e. In the Controller selection for pass-through select the controller is connected to DSC PowerSeries NEO panel. 1- Enter the Incoming encryption key and Outgoing encryption key gathered in the Neo Configuration section f. Click Ok

g. In the Panel Component tab, select the number of zones, partitions and users to be included h. Save the Integration module i. Click on Click here to open a configuration form again and select the Default user access code user code to be used for all disarming requests j. Save the Integration module NOTE: The uploading of the intrusion panel may take 2-3 minutes depending on the programming. During this time, the intrusion panel will be in programming mode. Once the intrusion panel uploading has been completed, an event called Panel components upload completed will occur on the message list. k. Go to Devices tab and select Integrated Components menu l. Select the user code previously selected with Default user access code and enter a valid PIN Programming user codes: 3- To program new user codes or to modify existing ones, go to the Devices tab and select Integrated Component. a. In the Integrated component tab, make sure the View component hierarchy button is pressed. b. To better manage the components, click on the All Components button and select Users. c. Select the Corporate gateway that the intrusion panel is connected to under the Gateway drop down list. d. From the Panel drop down list, select the previously created intrusion panel. e. From the Component drop down list, select a user and name the user accordingly. f. Click on Click here to open a configuration form g. Enter the user access code that will be used.

h. Save the configuration. Note: that there is an icon in the Component type list box. This icon represents the status of the component. NOTE: The EntraPass system can only download information from the intrusion panel while it is disarmed. If the intrusion panel is armed, EntraPass will buffer the modification until the intrusion panel disarms. Arming and disarming via manual operations: 4- To request an arming or disarming of partitions, go to the Operation tab and select Integrated component. a. If shown, on the left pane select the proper intrusion panel. b. On the right pane, select the partition you wish to arm or disarm. c. Right click on the partition and select a task. Intrusion on Graphics:

5- To view a virtual keypad or intrusion components from a graphic, go to the Definition tab and select the Graphic button a. Create a new graphic or choose the appropriate graphic from the Graphic drop down list. b. Click on the Click here to create, edit or modify a graphic button. c. Drag and drop the Panel component icon on the graphic screen. d. Select the Keypad from the list box. NOTE: You may also add zones and partitions on the graphic. You may arm and disarm partitions by setting default double click functions. e. Close the window by clicking on the at the top. f. Save the graphic. g. You may view a graphic from the graphic desktop.

Viewing events and reports: 6- To view intrusion events, go to the Desktop tab and select Desktop 1 Button. a. From the Message list, you can view all the access and intrusion events. b. To view only access or intrusion events, click on the All Events button and select the proper event type. 7- You may generate reports, video trigger, real time email notifications and alarm acknowledgments based on intrusion events. You can better search for events by sorting by access control events or intrusion events in the above mentioned windows.

Single partition management (by partition) via a reader: 8- To arm a single partition via a reader, go to the Devices tab and click on the Door button. a. Make the appropriate Gateway, Site and Controller selections, and select the door used for arming/disarming the partition. b. Go to the Options and alarm system tab and click on External alarm system options button. c. In the Alarm system options window: i. For arming: 1) If you are arming via card and pushing button, choose the appropriate input in the Arming request Input. 2) If you are arming via card and keypad button, choose the appropriate button to be used as an arming request in the keypad button drop down list. ii. iii. Choose when cardholders will be able to arm the intrusion system by choosing a schedule in the Enable Arming Request schedule textbox. Choose which card holder will be able to arm the intrusion system by choosing a single access level or group of access levels in the Arming access level textbox. iv. Go to the Disarming request tab and choose which card holder will be able to disarm the intrusion system by choosing a single access level or group of access levels in Postpone or disarm access level textbox.

v. Go to the Partitions tab and under the Partition to arm textbox select the partition associated to this door. vi. Check the Authorize disarming during exit delay if you want to be able to disarm during an exit delay. vii. Press Ok and save the door. NOTE: The default user code programmed earlier in step 2.f is used as the user code for arming and disarming of the partitions. PLEASE NOTE THERE IS NO VIRTUAL KEYPAD WITH THE NEO INTEGRATION.

Virtual Zones Programming: DSC PowerSeries Neo allows assigning up to 32 of its total zones as Virtual Zones. A DSC PowerSeries Neo zone can be triggered in Alarm, Trouble, Tamper by Kantech inputs, doors or controller events using Virtual zones. The benefit is that a Kantech Door can cause an alarm on a DSC PowerSeries Neo zone without any wiring Note: HS2016 can only have 16 virtual zones 9- DSC Virtual zones need to be assigned to a DSC physical zone using the DSC keypad using option a. On the keypad: [*8]-[5555],[560] b. Scroll the Virtual Zone desired and press * c. Choose the physical zone to be linked : ex: 009 d. Press # when done 10- Go to the Devices tab and select the Integrated Panel button. a. Select the previously created DSC PowerSeries Neo panel. b. Click on the Panel Component tab c. Under Virtual zone select the number of virtual zones you have. d. Save the integration module 11- Go to the Devices tab and select the Integrated Component button. a. Select the appropriate Virtual Zone in the Component dropdown list b. Click on the Click here to open the configuration form c. Choose the kantech component type to link in the Component type dropdown list d. Choose the Kantech component in the Component source e. Check the proper DSC Component action the Virtual zone will cause on the DSC PowerSeries Neo. f. Press Ok g. Save the virtual zone

EntraPass Events to DSC Virtual Zones status: Door Input Controller EntraPass EntraPass Events Input in Alarm Input in Trouble (only Double EOL) Input tamper in alarm (only Double EOL) DSC PowerSeries Neo REPORT REPORT REPORT ALARM TROUBLE TAMPER Open/Close (Door contact status) Door forced open Door alarm on relock Door pre-alarm open too long Door open too long Door lock device failure Tamper switch in alarm Controller AC power failed Controller Auxiliary power failure Controller reader power failure Controller battery power failure Controller module communication failure Controller DC power failed Controller lock power failed

The PowerSeries Neo/Kantech integration provides users the following abilities: Receiving programming of the intrusion system - The partition and zone names can be uploaded to the EntraPass Software from the intrusion panel. The partitions and zones can be used for various actions such as operator operations. In addition the user codes can be uploaded from intrusion panel and stored in the EntraPass Software. The EntraPass operator can program and download to the intrusion panel new user codes or modify existing ones. Receiving events from the intrusion panel - The intrusion panel events can be viewed on the Message list and used for reporting in conjunction with the standard access events. Furthermore, these intrusion events can be used to trigger video recordings, pop-up alarms, email notifications and other actions. Manual operations from EntraPass - The operator can perform manual operations on partitions from the EntraPass software, operations such as: Partition arm away, partition arm stay, partition arm no entry delay, partition arm with code and disarm partition with code. Using intrusion components on graphics - The uploaded zones and partitions can be used in graphic floor plans to visualize where each zones, partitions and traditional access control components are on the floor plan. The operator can view the status of each of the components and perform operations on partitions. Arm and disarm partitions - The intrusion panel partition can be linked to a reader or readers to request an arming and disarming of the partition via a card. When a card holder presents his card and pushes the appropriate button on the reader, the KT-400/KT-1 will send an arming request to the intrusion panel. When a card holder presents his card and opens the doors, the KT controller will send a disarming request to the intrusion panel. The EntraPass software supports single partition management per reader or multiple partition management per reader. There is NO support for Virtual Keypad at this point with this integration.