INSTALLATION & OPERATIONS MANUAL
2 TABLE OF CONTENTS NOTES FOR SAFETY.3 EQUIPMENT AND FUNCTIONS...5 GENERAL FEATURES SAFETY FEATURES 1. ACCESSORY ILLUSTRATOR 2. OUTPUT BOARD AND OUTPUT MANUAL 3. MODE PROGRAMS STARTING STIMULATION AND IMPORTANT CAUTION 7 NOTES FOR SAFEKEEPING..9 CHECK-LIST BEFORE REPAIR TECHNICAL SPECIFICATION 10 WARRANTY.11
3 Thanks for purchasing our ultrasound stimulator. We are an expert maker for electro stimulation devices who always keep researching and working on client s side. This device has been developed based on our technology and know-how accumulated through continuous R&D. This manual will help you to use the device safely and to realize the excellence of it. Please read this manual carefully before usage to operate this device correctly and keep it together with Warranty Sheet always at the place you can easily reach out. I. NOTES FOR SAFETY For safety, and to prevent any loss of customer s property, please read below mentioned statements and use properly according to them. We are not responsible for any accident or damage due to the user s voluntary disassembling or remodeling of the device. Check the data plate for voltage, cycle, phase and ampere requirements. Locate the device on a level, stable surface. Do not give any shock to the device. Do not wear any metallic and conductible accessories. Do not use together with other electrical devices at the same time. Never expose the unit to water. Keep away from humid place. Keep the device out of the reach of children Never dismantle and remodel the device Only use accessories approved by ChungWoo Do not pull on cords or connectors Never touch power plug and cord with wet hand.
4 Be sure to follow below mentioned contraindications. Those people who suffer from any of the following diseases or are showing any symptoms should not use the massager. Over organs (stomach, liver, lungs, spleen, blowels, heart, kidneys) Over the pelvis, abdomen and lumbar (lower back) region in Pregnant or potentially pregnant females Over highly ultrasound-sensitive organs (eyes, ears, ovaries, testicles, brain, spinal cord) Over mucous membranes (mouth, nose, rectum/anus, vagina) On patients with pace-makers on patients with phlebitis, deep venous thromboses On patients with hemophilia On patients with spina bifida or surgical laminectomies of the spine On tissue and/or bone with active infection Over areas suspected to be cancerous or pre-cancerous Over de-sensitized (numb, hypoaesthesia) areas of the skin (eg. Diabetic neuropathy) Over open sores or lesions In the front of the upper neck (thyroid region) Over areas that have had cortisone injections in the last 30days
5 II. EQUIPMENT AND FUNCTIONS Ultrasound stimulator, is an Ultrasound stimulator which is effective mainly on pain relief applying 1MHz of ultrasound head on the body. This basically has various functions which can be used according to the sort of symptom. can be used for the treatment of muscular and bone pain syndromes as adjunctive therapy to post traumatic injuries and post surgical pains, rheumatism and arthritis, muscle spasms, scar tissue, and joint adhesions etc. In case of special request, the function of 3MHz with additional conductor will add the current unit as an option to soften hypertrophic scars and for other superficial applicators. GENERAL FEATURES 4 different kinds of operation modes (Modulation /continuation /vibration /beat) With 4 pre-set output frequency selection user can manually select proper low and high frequency for optimal effect. Come standard with 4cm²/1MHz frequency conductor Two optional 2cm²/3MHz or 4cm²/3MHz frequency conductor is available depending on its need. SAFETY FEATURES Protection by fuse - Stabilized safety fuse at each (3.15A). 1. ACCESSORY ILLUSTRATOR Frequency Conductors w/ Cable: It is an applicator that apply Ultrasonic wave to the affected body by putting it on the body part. The bigger 1MHz conductor is used on abdomen, buttocks, waist, belly and hips. The optional small 3MHz conductor is used on face, arms and calves etc The optional bigger 3MHz conductor is also available.
6 2. OUTPUT BOARD AND OUTPUT MANUAL 1 OUTPUT SELECTION INDICATION 2 OUTPUT INDICATOR BUTTON 3 START BUTTON 4 STOP BUTTON 5 MODE SELECTION BUTTON 6 MODE INDICATOR 7 STEP SELECTION BUTTON 8 TIME INDICATOR 9 TIME ADJUSTMENT UP/DWON KEY 10 OUTPUT INDICATOR 11 INTENSITY ADJUSTMENT UP/DOWN KEY 12 OUTPUT PORT FOR 1MHz & 3MHz 13 POWER SWITCH 14 POWER SOCKET 15 SPECIFICATION STICKER 3. MODE PROGRAM Mode Step 1.3 1.5 1.7 2.0 3.0 Wave Form Reference 1 MHz of current is stopped and applied Modulation 2.4w 2.8w 3.2w 3.8w 5.6w intermittently(stops for 440msec and applied for 370msec) Continuation 7.6w 8.8w 10.0w 11.8w 17.0w 1 MHz of current is continuously applied. Vibration 1.8w 2.1w 2.3w 2.8w 3.8w 1 MHz of current is applied for 200msec and stopped for 150msec intermittently. Beat 1.8w 2.1w 2.3w 2.8w 3.8w 1 MHz of current is applied for 90msec and stopped for 120msec.
7 III. STARTING OPERATION AND IMPORTANT CAUTION First of all, have the patient sit in a relaxed, comfortable posture or lie on a bed. 1 Connect the power cord to the outlet. 2 Turn on the power switch at the backside of the device. 3 Connect the wire lead of your desired ultrasonic conductor into the right insertion hold of output port firmly. 4 In case of using 1MHz conductor press key to select the output. When you turn on the power switch at the backside of the device then initial display shows the selection of 1MHz output frequency automatically. Confirm that the value of the output intensity is to 0 position. 5 Press or button to select the desired program mode. 6¹ Select the desired low and high electric impulse by pressing or button gradually. 6² Or you can select one of 4 pre-set output range in the out section, which are commonly used. Never operate the unit with wet hands to avoid an electric shock.
8 7 Press or button to set the desired time. 8 The stimulation will start to run by press key. Please apply enough ultrasonic conductive gel to applied part of body before operation. 9 After time is over beep sound is ringing and the operation is automatically off. Then press to completely stop the operation. 10 Turn the power switch off at the back panel of device and plug off the power cord and keep all the equipment safe.
9 IV. NOTES FOR SAFEKEEPING CAUTION Do not place the device at the humid place like bathroom This device is composed of electronic precision components keep away from humid place. 1. After usage, turn off the switch and plug out 2. Keep away from direct sunray and humidity 3. Pull out the power cord. Wipe out the device using clean and soft cotton. 4. While deliver the device, do not drop the device. Severe impact on device also is prohibited. 5. While cleaning the exterior of the case, do not use chemicals like benzene, thinner 6. Do not sprinkle the water on the main device, it may cause short circuit or electric shock. 7. Do not keep it close to the children. 8. Make sure to separate electrodes and power cord from the main device for safekeeping. CHECK-LIST BEFORE REPAIR Power lights not on. Check if power cord is connected. Check if power switch on the back panel is on position. When the intensity cannot be controlled. Check if the wire lead of the applicator is firmly connected into the right insertion hole of the device depending on output MHz you start to operate. When you cannot feel any intensity from the output. Check if the cord of the applicator is correctly connected to the device. Check if the intensity is too low. When the problem still remains even after you checked above, please ask sales distributor or its A/S center.
10 V. TECHNICAL SPECIFICATION MODEL OUTPUT RANGE TIMER POWER CONSUMPTION 0 17W 1 30 min, adjustable 50W DIMENSION (mm) 290(W) X100(H) X 235(D) ( w/o cart ) WEIGHT POWER ELECTRIC SHOCK PROTECTION 3.2kgs AC 220V, 50/60hz Class I BF
11 Warranty Sheet Product Name Sales shop Model Tel no. Seller Product No. Rated Voltage Date of Purchase Person in Charge Applicant name Applicant Tel no. Applicant address Warranty period 1year from date of purchase Gender / Age - Please fill out above when you purchase the product. - We are not responsible for the after service or any disadvantage when you do not have a warranty sheet. Regulation of Warranty <Warranty Period> Warranty period is 1 year after the date of purchase with no repair charge in case the damage happened in normal condition of the device. <The exception of warranty> We are not responsible for: 1. Damage due to careless handling or mistake by user. 2. Damage due to renovation of production or repair by others than our A/S representative. 3. Damage due to using other accessories or expendables than our appointed equipment. 4. the case the warranty sheet is not filled out, without signature or falsely filled out. 5. Damage cause from the power problem 6. Damage due to using the device for other purpose. 7. Damage due to natural disaster like fire, earthquake, flood and etc. < Repair after warranty period> For the repair after warranty period, repair charge is paid by the purchaser. The exceptional matters which are not mentioned in this sheet will be treated according to regulation of compensation for consumers based on law of consumer protection. Please contact to the sales shop for the other damage or request. Please read the manual carefully before using. Thanks for purchasing our product. You will need this warranty sheet when you ask for A/S, so please keep this safely. For any dissatisfying service or request, please contact the sales shop.