CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems

Similar documents
*suitable both for membrane sensors or chlorine open cell

Electronic Dosing Systems Ltd

Range. Body Material. Max. Press ms K=0, C 4 bar Glass Graphite 13.5 PG Full integrated 5-meter cable

EL300. Multi-Channel Water Controller. Specialist Of UV Spectroscopy

Control and automatic dosing

Conductivity Transmitters

LD MULTICHANNEL - LD MULTICHANNEL PLUS

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Controllers. Metal Finishing. and Surface Treatment

SMART SENSORS. Water quality sensors with built in digital & analog microtransmitters

Controllers. Water Treatment

Control instruments GUARDIAN 2 - GUARDIAN 3

LDS - LDS PLUS SINGLE READING DIGITAL SYSTEM. DELAY Programmable delay at dosing start-up (up to 60 minutes).

Neon pr. ph/ ORP measurement. Applications. Description

Solutions to the Most Challenging Environments

Double-channel measuring and control instrument for free chlorine and ph-value - additionaly ORP optional

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

GRYF. Measuring Instruments. For Fisheries. Practice and research

MMT330 Series Moisture and Temperature Transmitters for Oil

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

MXD70 SERIES. Instrumentation to meet your Process Requirements. Features.

Handheld Water Quality Meters 100 Series

LDCL DIGITAL CONTROLLER OPERATING MANUAL

Signet 9900 Transmitter

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

Type Multichannel Transmitter/Controller multicell for Flow and Analytical Sensors

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water

WATERGUARD WG-602 FREE CHLORINE ANALYZER. User Manual

Digital O.R.P. Transmitter Type 8206

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive)

About Suntex. Online Measurement and Control. Portable and Laboratory Instruments. ISO 9001: 2000 Certificated since 2001

Digital ph-controller

Electrochemistry Meters. Series SD (IP 67 waterproof) Electrochemistry Meters

Instrumentation for Process Analytics

mxcontrol Multifunction Controller

FLS M9.06. ph/orp MONITOR

DIN-Rail Mounted Ultrasonic Flow Meter

GRYF. Measuring Instruments. measuring electrochemical and physical values. monitoring the environment. controlling technological processes

GENERAL SAFETY GUIDELINES

Plug & Play Analytical Solutions Making Basic Measurements Easy

world class water monitoring series 42

T80 Universal Transmitter S80 Intelligent Sensors

Min. Conduct. Measurem. range. Body Specification ELECTRODE PH 6M SENSOR XS 0 14 ph 100 us 6 Bar (25ºC)/80ºC Epoxy/12x150mm 6

Introduction: Features:

APPLICATIONS. Boiler / Burners Turbines Engines Incinerators Process Control Landfills Cogeneration plants

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Portavo. Portavo. Applications

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

Intelligent SUNTEX EC4110(RS) Conductivity Transmitter

ph and Electrochemistry

HI 9828 Multiparameter Water Quality Meter...

JUMO dtrans AS 02. Transmitter/controller for standard signals and temperature

MCX08M2 Programmable controller

AG SELECT B1. OPERATING INSTRUCTIONS AND MAINTENANCE UNI EN ISO

DOSING EQUIPMENT CATALOGUE

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Instruction Manual. Liquitron DP5000 Series ph Controller. For file reference, please record the following data:

HI 9828 Multiparameter Water Quality Meter...

50Series. Plug & Play multi-parametric process controller

Electrodes ph EC DO /14 dge 2 P/L e

Resolution selectable from 0.01 and ph. Range to ph. Accuracy ± ph

Digital ph-transmitter. Type Advantages / Benefits. Design. Application

DTM Distributed Transmitter Monitor

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

WK7200. Water Quality Test Kit USER S MANUAL

LDCL DIGITAL CONTROLLER O P E R A T I N G M A N U A L

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

WebMaster WIND. Industrial Water Controller OVERVIEW SUMMARY OF KEY BENEFITS

WebMaster. Cooling Tower/Boiler Controller. ONE simple and flexible controller for ALL your water treatment needs! SUMMARY OF KEY FEATURES

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

How to build a Conductivity Measurement System

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Industrial Water Treatment Controllers

UNIVERSAL SMART INSTRUMENT. Intelligent Flow, Level and Water Quality Monitoring

Waterproof Tester ph - mv - Conductivity - TDS - Salinity - Temperature

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

ATR121 Controller with Dual Setpoint

Model T28 Transmitter

Single Parameter Meters Lightweight and versatile ph, EC and DO meters that can be used in portable, wall-mount and benchtop configurations

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet

Waterproof Testers. ph - mv - ORP - Conductivity - TDS - Salinity - Temperature

HL Series Ultrasonic Level Meter

Handheld Water Quality Meters 100 Series

Controllers for compressor racks with advanced energy saving. PN08 September 2016

Please enter the identity code of your device here!

Meter Selection Guide

Expandable Modular Data Acquisition System inet-400 Series

Instruction manual of the controller unit. PCS ph-redox-chlorine-temp PCS ph-oxygen-temp PCS ph-redox-temp

About Suntex. Online Measurement and Control. Portable and Laboratory Instruments

Transcription:

Chemical Injection skids CONTROLLERS Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems Containarised Water Treatment systems

CONTROLLERS AND MEASUREMENTS TOUCH controller series MEASURING PARAMETER: Free (residual), Total chlorine; ph, RX (ORP); Dissolved Oxygen; Hydrogen Peroxide; Conductivity (µs); Chlorine Dioxide; Peracetic acid, Cooling towers controller, BMS controllers. TOUCH 4 7 5 parameters COMMON FEATURES Touch screen controllers with graphic display Simultaneous measurements, temperature, alarm and flow status Graphic icons for Errors, Alarms, output and Input status Scrolling parameter selection by touch screen Expandable relay outputs to control other remote equipments Relays outputs activations by timer control or measurements settings Configurable ma outputs according requirements ma outputs galvanically isolated Universal power supply 90 240 Vac (upon request 12 24 Vdc) Real time clock configurable as Timer to drive controller functions Time out of dosing pump over dosage via timer or pulses control Level control for external chemical tanks (according to parmeters) Proximity switch functions Hysteresis and Max/min Alarm adjustments, Alarm overdosage Manual and Automatic temperature, programmable settings Programmable Menu Basic / Expert Standard Ethernet connection, Modbus protocol Data recording and Internal memory USB port direct download on Pen drive IP65 ABS UL94 HB enclosure, hinged lid Touch1 model enclosure V0 self extinguishing (available for other models) Available upon request IP56 ABS enclosure Other features available upon request, after submitting technical data OPTIONS UPON REQUEST WI-FI connection RS485 Adaptor via external Pen drive GSM / GPS external module AVAILABLE MODELS TOUCH 3 4,3 3 parameters TOUCH 2 4,3 2 parameters TOUCH 1 4,3 1 parameter TOUCH 4 7 display touch screen controller 4 measuring parameters + temperature, all with simultaneous visualization 11 relay (expandable 16): 5 set-points On-Off + 6 Aux/Alarm configurable outputs 5 Proportional (PWM) time / pause output to drive On-Off equipment 4 of 4 20mA (expandable to 6) programmable outputs 2 TTL outputs for dosing pumps related to set-points of two measurements 3 Level control inputs for external chemical tanks Available with 4 1/3 touch screen display TOUCH 3 4,3 display touch screen controller 3 measuring parameters + temperature, all with simultaneous visualization 11 relay (expandable 16): 4 set-points On-Off + 7 Aux/Alarm configurable outputs 4 Proportional (PWM) time / pause output to drive On-Off equipment 4 of 4 20mA (expandable to 6) programmable outputs 2 TTL outputs for dosing pumps related to set-points of two measurements 2 Level control inputs for external chemical tanks TOUCH 2 4,3 display touch screen controller 2 measuring parameters + temperature, all with simultaneous visualization 6 relay (expandable to 16): 3 set-points ON-OFF (2pH)+1 Alarm+2 Aux outputs 3 Set-points ON-OFF with 2 voltage free outputs 3 Proportional (PWM) time / pause output to drive On-Off units 4 of 4 20mA programmable outputs + 2 TTL outputs for each each setpoint 2 Level control inputs TOUCH 1 4,3 display touch screen controller 1 measuring parameter + temperature, all with simultaneous visualization 3 relay (expandable 8): 2 set-points ON-OFF + 1 Aux/Alarm configurable outs 1 Proportional (PWM) time / pause output to drive On-Off equipment 2 of 4 20mA programmable outputs 1 TTL outputs for dosing pumps related to set-points of two measurements 1 Level control inputs for external chemical tanks

CONTROLLERS AND MEASUREMENTS CTRL enclosure IP65 ABS, 231w x125h x90, V0 (fireproof) easy access via hinged front panel with safe lock CTRL/B enclosure IP56 ABS, 204w x149h x85-ul94 HB easy access via front panel locked with captive screws CTRL/R enclosure, PPO plastic self-extinguish, DIN 43700 type 96x96 for rack mounting CTRL/din enclosure, PC/ABS plastic self-extinguish, DIN rail 43880 (EN 60715) MEASURING PARAMETER: Free (residual), Total chlorine; ph, RX (ORP); Dissolved Oxygen; Hydrogen Peroxide; Conductivity (µs); Chlorine Dioxide; Peracetic acid, Cooling towers controller, COMMON FEATURES Large display 128x64 with graphic display Simultaneous measurements, temperature, alarm, flow status Graphic icons for Errors, Alarms, output and Input status Conf igurable ma outputs according requirements Univ ersal power supply 90 240 Vac (upon request 12 24 Vdc) ma outputs, adjustable settings and galv anically isolated Lev el control for chemical tanks (according to parameters) Proximity switch f unctions and Digital inputs Hysteresis and Max/min Alarm adjustments Real time clock conf igurable as Timer to drive controller Alarm ov erdosage via time or max pulses Automatic / Manual temperature settings Programmable Menu Basic / Expert OPTIONS UPON REQUEST - Ethernet connection, Modbus protocol - USB port direct download on Pen drive - RS485 Adapter via external Pen drive - GSM / GPS external module (options not available with DIN housings) AVAILABLE MODELS CTRL3 plus 3 measuring parameters + temperature, simultaneous visualization 8 relay s (expandable to 12): 4 set-points ON-OFF + 4 Aux/Alarm conf igurable outs 4 of 4 20mA programmable outputs to driv e dosing equipment or data logger 2 Lev el control inputs+real time Clock/Timer to program CTRL or aux outputs CTRL2/6 plus 2 measuring parameters + temperature, simultaneous v isualization 6 relay s: 3 set-points ON-OFF + 3 Aux/Alarm configurable outs 4 of 4 20mA programmable outputs to driv e dosing equipment or data logger 2 Lev el control inputs+real time Clock/Timer to program CTRL or aux outputs CTRL2 plus 2 measuring parameters + temperature, simultaneous visualization 4 relay s: 3 set-points ON-OFF + 1 Aux/Alarm configurable outs 2 of 4 20mA programmable outputs to driv e dosing equipment or data logger 2 Lev el control inputs CTRL plus 1 measuring parameter + temperature, simultaneous visualization 3 relay s: 2 set-points ON-OFF + 1 Aux/Alarm configurable outs 1 Proportional (PWM) time / pause output to drive On-Off units 2 of 4 20mA programmable outputs to driv e dosing equipment or data logger 1 Lev el control input+real time Clock/Timer to program CTRL or aux outputs CTRL 1 measuring parameter + temperature, simultaneous visualization 2 relay s: 2 set-points ON-OFF 1 Proportional (PWM) time / pause output to drive On-Off units 1 of 4 20mA programmable outputs to driv e dosing equipment or data logger 1 Lev el control input NOTE: f or all the TOUCH and CTRL series, all the PH controllers include also the selection of RX (ORP) unit. In case the double or triple controller f eatures both parameters.

ELECTRODES AND SENSORS AMPEROMETRIC MEMBRANE SENSORS CLS CLS series offers a large selection of potentiostatic ion-selective chlorine sensors membrane principle, for measuring: Free Chlorine Inorganic and Organic, compatible with Isocyanuric Acid, sensors suitable with presence of Surfactants/Flocculants, for potable and salt water, Salt water, Ozone, Hydrogen Peroxide, Peracetic Acid. Suitable for a wide choice of measuring ranges and applications. Fast and easy calibration procedure: only one point to calibrated Temperature compensation is integrated within each probe No environmental disturbances thanks to sensors low impedance Long lifetime and very little required maintenance AMPEROMETRIC CHLORINE CELL CLC CLC are open system amperometric cells able to the measure inorganic free chlorine with the possibility to control the actual incoming water flow hosting a proximity switch for output signal (switch upon request). Keeping a good maintenance and a steady flow, will obtain great results with competitive prices. Self-cleaning cell with glass balls Range 0 10 ppm. Electrode Platinum/Copper Max pressure 5 bar - Max temperature 5 60 C CLC 3 chlorine cell+2 electrode+temperature sensor holder, flow sensor proximity switch, incoming flow adjustment CLC 2 chlorine cell+2 electrode+temperature sensor holder CLC 4 chlorine cell+proximity switch temperature sensor holder COMBINED PH AND RX ELECTRODES Electrodes with cables from 1 to 15 m length Electrodes without cables DIN Connection PG13,5 threading Epoxy body Glass body Max pressure from 1 bar to 16 bar Max temperature from 60 C to 130 C TURBIDI TY SENSOR Turbidity sensor CELL TURB Measuring range: 0 40,0 or 0 20,0 NTU (to specify at the order) Functioning mode: optical transmission by 90 Light photodiode Liquid Ends: PVC body PP fittings DISSOLVED OXYGEN SENSOR Dissolved Oxygen sensor with NTC temperature sensor Range 0 20,0mg/L,1ppb to saturation or 0.01% 200% of oxygen CONDUCTIVITY PROBES Ranges 0 200 µs; 0 2000 µs; 0 20.000 µs; 0 200.000 ms With cables 4m up to 30 m length with amplified probes AISI 316 or Graphite electrodes Probes amplified via internal NTC and thermo-compensated Body PVC or PTFE TEMPERATURE PROBES Ranges up to 100 C With cables from 1 to 15 m length Body AISI, PVC, PTFE PT100 probes in GLASS, AISI, PVC

SENSORS ACCESSORIES FWT has developed a new modular in-line probe cell: - great versatility in choosing one or more modules according to requirements allowing money saving; - a base module for detecting flow and temperature and flow adjustment thus allowing the ideal flow required; - every sensor has its own module for: ph/rx electrodes, Oxygen PT100 temperature sensors, high linearity conductivity probes; - Membrane system Ion selective sensors have their own module clearly for their peculiarity; - clean and visible operations; - outlet fitting to take sample and/or emptying the cell module; - easy to use, install and maintain; - separate modules can be replaced without affecting operations Probe holder for a variety of electrodes, sensors and functions Submersible probeholder, PVC body, length 50 cm, 1 m, 1,5 m In-line electrode holder, PVC or AISI316, connection 1/2 Proximity switch to detect in-coming flow Impedance adapter for remote installations Buffer solutions DOSING PUMPS ACCESSORIES Electric Mixers Manual Mixers Suction lances Pulse emitter water meter (threaded) from 1/2 to 2 Pulse emitter water meter (flanged) from 2 to 8 Complete hydraulic kits for monitor panel assembly Dosing tanks Bunds and fittings Safety valves Back pressure / Relief valves Anti-syphon valves Pulsation dampners