EcoFlex LED Neon Manual

Similar documents
High Intensity Flexible LED Accent Lighting 5-YEAR WARRANTY F L E X I B L E L E D L U M I F L E X L E D S I M U L AT E D N E O N

Flexible Top Light 270. Features and Benefits.

DIN Molded Cable Assemblies

Features & Benefits LIGHT STRIP 15

Zone Pressure Touch Sensor - Standard Range

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

7-Port Charging Station for USB Devices

LINEARlight FLEX Accessories

the Interactive Catalog

Light Distribution. LED Chip. Dimming. Mounting. Reel Lengths. Certifications. Operating Temp. Environment. Ordering Information

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

RGB 160. Features and Benefits.

Diffuser Color (when not illuminated) Light amber hue

7-Port USB 3.0 Hub - Desktop or Wall-Mountable Metal Enclosure

Installing 6 Indexer: PRS Standard Tools

Photoelectric Sensors Comet Series

MODEL 8000MP LEVEL SENSOR

5 LENGTH. Lead wires at one end. Lead wires at both ends. See length ordering guide. Standard is 0970(970mm) atex-jp.

Photoelectric Sensors Comet Series

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

IP68 Sealed - Mini USB Buccaneer

LED. Sign Module. Assembly Manual

NUTP6-16LEDRGB 12V 16' RGB Color Changing LED Tape Light Roll Source: 40W LEDs

Connecting cables for valves, plug pattern ZC, metric screw Type codes

NUTP3 Series 24V RGB LED Tape Light (Color Changing) Source: 2.5 Watts Per Foot ACCESSORIES LED DRIVERS ILLUMINATING THE FUTURE...

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

Telephony Multi-Taps. 9000T-TP Series

Please read the Operational Manual before attempting to use this product. Operational Manual

Zone Pressure Touch (ZPT) Sensor - Standard Range

PROJECT: SPECIFIER: TYPE: QTY: OUTPUT LEVEL: COLOR: LENGTH X WIDTH: MOUNTING: DIMMING/CONTROLS:

Quick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1

Magellan Wireless Backup Camera

onlinecomponents.com

Nano Liner Allegro AC XB RGB / DW INSTALLATION GUIDE V1.2

IEEE 1394 Connector. Range Overview IP Receptacle to Overmolded with Cable In Line. Accessories. IEEE 1394 Connector I Range Overview

PV Rapid Shutdown device

MC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA

Technical data: Pin Spacing

SW-504 Industrial Unmanaged Ethernet Switch 4 Ports

TCNM-ACBB1 Installation Manual

F-LED 255 (WIDE BEAM)

SAVE THESE INSTRUCTIONS

D-Sub SEaled subminiature D connectors, 2.54 mm pitch

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Source: 1.5 Watts Per Foot

BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE

Pile Driver Weld Immune Sensors

M A C 3 Wind Speed Alarm & Controller

AION LED WT SERIES. Custom Lengths. Made in the USA IP66* High Efficacy Exterior Rated Linear Fixture System

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Energetic diffuse reflection light scanner. Dimensioned drawing

Product Description. Quick Spec. Fully Dimmable: Voltage: Total Wattage: Beam Angle: Yes 24V DC 36W 120º

Series 3000V Input/Output Board

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

Inverted Thru Board Card Edge: BTB

37 lumens per foot, see page 4 for details (7M), 1 spool. IP68, wet location and submersible* IK08, protection against 5 joule impact

SP-100. Service Manual Aug. 02

Basic Series 18 mm Diameter Cylindrical Sensors

WLC60 Heavy Duty Stainless Steel LED Light

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Bulletin 854K 60 Mm Control Tower Stack Lights

LNT-45RGBW 4.4W IP65 COLOR-CHANGING LED STRIP

NUTP3-LEDRGB/6 24V 6" RGB LED Tape Light Section Source: 1.25W LEDs

Plasma Panel Replacement Guide DU-42PX12X

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

RGBW 8.8. RoHS Compliant DIMENSIONS PART NUMBER BUILDER = Your Part Number

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

The Edge RGB LED Strip is a unique light source designed especially for edge-lighting applications.

NUTP4-LED/12 12V 12" Standard LED Tape Light Section Source: 1.5W LEDs

RL70 INDUSTRIAL FLUORESCENT TUBE LIGHT

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

CABLE ENTRY SYSTEM KDSClick

Diffuse reflection light scanner with background suppression. Dimensioned drawing

MAC3 Wind Speed Alarm & Controller. Installation Instructions

Model 720 Electromechanical Hour Meter

Family Modification Watts Dimmable CCT ASD-UHB 2 XX D XX LED UFO High Bay 100 = 100 W Dimmable 50 = 5,000 K 150 = 150 W 200 = 200 W

Perle MCR200 Installation Guide

2 PIECE BOARD-TO-BOARD

This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

3M Pak 100 Wiremount Plug Series

Plexineon Color Series

Basketball Shot Clock Set LX2180 Manual

SEPTEMBER C.CS.1000 / GB

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Connecting cables for valves, Sub-D socket Type codes

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

PRODUCT DATA SHEET. ColorBright Color Changing. RGB 150 Series. Year Warranty.

Sensor Connectivity Introduction Global Plus Connector Cables Multi-Connector Blocks. Product Selection Guide...

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

Installation manual for for Schleifenbauer DPM3

Pictured: RibbonLyte SP K. ACOLYTE LED 251 West 30th St, Suite 12E New York, NY

Type. Project. Catalog No.

HEADERS & RECEPTACLES

Data sheet C6 A modul 90 jack

M215-Z Safety Information (M LL-IG-ZC)

RS-232 Industrial Media Converter

HL-DL. Direct View Architectural Delineation LED System INSTALLATION GUIDE

Transcription:

Manual Part number: LN-ECO-XXXX-10m from Environmental Lights is one of the most flexible and cost-effective members of our line of LED Neon products. It allows you to achieve the creative potential of traditional glass neon while getting all the benefits of LED. With 10-meter run lengths that only need to be powered from one end, is UL Listed and saves time and money on installation. It runs on 24 volts DC and its silicone casing provides protection and excellent diffusion for a hotspot-free appearance. is incredibly flexible, with a 60mm minimum lateral bending radius. It is low maintenance and easy to control. It is also easy to customize with our various end caps, connectors and wire exists, making it perfect for use in retail, scenic, architectural and other decorative lighting installations Feature Flexible silicone housing UV resistant and low maintenance IP65 rated with factory-sealed ends Easy to install 10-meter run length when powered from one end UL Listed EnvironmentalLights.com

Specifications Voltage Power Consumption Dimensions LED quantity Minimum bending diameter Waterproof Rating Certifications Warranty 24VDC 9 Watts per meter (2.7 Watts per foot) 14.5mm x 24.25mm (0.57 inches x 0.95 inches) 120 LEDs per meter 120mm IP65 UL Listed, RoHS 3 years limited Warnings and Caution Warning Before making any cuts or performing installation/maintenance, be sure all electricity is disconnected. Operate LED Neon lighting according to instructions only. Confirm the polarity of connectors before inserting. Connect and cut this product correctly. Must use cutting shears designed to cut LED Neon (listed in accessories tab). Incorrect operation will damage the circuitry. Caution Use only factory-recommended shears, connectors, and accessories. Do not operate in more than 45 C (110 F) ambient temperature. Do not operate light when ambient temperature is below 0 C (32 F). 2

Assembly and Installation 1. Be sure to mount the LED Neon correctly, as illustrated by figures 1-4. 2. LED Neon can be cut every six LEDs at specific cut points. Look for the black lines on the circuit board to indicate where cuts can be made. Be sure your cut is a straight line, perpendicular to the neon light as shown below. 3

3. Make sure the connector is being inserted into the correct side of the. The pins of the connector need to be inserted into the tail end of the arrow found on the circuit board as shown below. Inserting the connector into the wrong side could possibly damage the neon. Always check the functionality after inserting a connector and before sealing the connection to ensure proper fit has been achieved. 4. Connecting your accessories properly is key to maintaining the lifetime of the LED lights. 10 meter reels will be received with a front connector fully sealed onto one end and an end cap on the other end. 4

Assembling Connectors Insert the strain relief bracket into the LED side of the circuit board. Insert the connector onto the back side of the circuit board. The strain relief bracket and the connector should be sandwiching the circuit board. Connector installation guidelines: Fill the connector cover pieces 1/3-1/2 way filled with glue to ensure a tight seal around the LED neon. Ensure that the glue forms total seal around both the neon and the power cable. The connector cover pieces must be fully secured against one another. A rubber mallet might be necessary to get the two pieces fully secured without any gaps. The glue must set for 24 hours before the connector is ready for use. Moving the connector before this time has elapsed can result in defects. 5

Front Exit Connectors Bottom Exit Connectors End Caps 6

Interconnect Sets Top Anchors Mounting Clips 7

Mounting Channel There are two types of mounting channel available for. For either, use screws to mount the channel, then install the neon into the channel. 8