JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Similar documents
JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Immersion Temperature Sensors

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

JUMO mtron T Measuring, Control, and Automation System

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Level measurement CleverLevel LBFH Point level detection

Level measurement CleverLevel LBFI Point level detection

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

JUMO Quantum PID100/PID200/PID300

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Temperature Switches

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display For sanitary applications Model PSA-31

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Operating Instruction

Approx. 4 s, measured in oil, with a probe Ø of 10 mm made of stainless steel. Influential effect of the ambient temperature

Multi-range pressure and differential pressure transmitter

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Electronic pressure switch with display For sanitary applications Model PSA-31

Level measurement CleverLevel LBFI Point level detection

Push-in RTD temperature probes with terminal head form B

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

Micro calibration bath Models CTB , CTB

the Interactive Catalog

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Screw-in resistance thermometers with terminal head Form B

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Millenium II +: general characteristics

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

Inductive sensor BI1.5-EG08-Y1-H1341

Flow VA 500/

Resistance measuring module

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

TCNM-ACBB1 Installation Manual

Pressure sensors SPAW with display

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

OPTISWITCH 6600 C Technical Datasheet

AS-Interface I/O Module

J itron DR 100 Microprocessor Controller

Magnetically Inductive Flowmeter

Liquiphant T FTL20. Technical Information. Level limit switch for liquids

LS 5000 series Vibration Level Switch for liquids

Level sensor for monitoring the level of liquid media

Control Head for the integrated mounting on process valves

Inductive sensor NI3-EG08K-Y1-H1341

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

Linear Position Transducer HLT 1000-R2

Pneumatic Control/Feedback

Distance and Position Sensors

Pneumatic Control/Feedback

60 Ghz - Radar filling level sensor RFM 2000 C4 / R / MD

Absolute Encoders Multiturn

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Electronic Level Switch ENS 3000

Electronic pressure switch with display For sanitary applications Model PSA-31

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Dial Thermometer. Particularities. Brief description. Technical data. Page 1/6. Data Sheet

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

JUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

Pneumatic Control/Feedback

Technical Information Liquipoint FTW23

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Level measurement. Applications. Special features. Description

Pressure transmitter/pressure switch PASCAL CS

Inductive sensor BI5-EM18-Y1X-H1141

PRODUCT INFORMATION. G6 Global Sensor. Beyond the standard Global sensor the economic way to business class

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Inductive sensor BI1.5-EG08-Y1-H1341

Product and Function Description

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

standard, short, preferential, top

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

Pressure transmitter/pressure switch PASCAL CS

Digital electropneumatic Positioner for the integrated mounting on process control valves

Industrial Pressure Transmitter

Operating instructions. Switching amplifier DN0210 DN / / 2015

Installation Instructions Temperature transmitter TAA /00 06/2011

Multiturn absolute encoder

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Float switch For industrial applications Model RLS-1000

Air gap sensors SOPA

Temperature sensors and accessories for heat and cooling measurement points

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

Product description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors

Power supply module, bus connection module

Pressure sensors SDE1, with display

Transcription:

sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous media. The measurement method is based on the calorimetric measuring principle and therefore does not include any moving parts. This measuring principle is based on the cooling of a heatable temperature probe. Due to the flow behavior of the liquid, heat is taken from the temperature probe. The higher the flow velocity, the higher the heat emission of the heating element. The measured value can be output via an analog output from 0(4) to 20 ma. A variant with switching output is also available. The state of the device is displayed using 3 LEDs. The JUMO PINOS L01 can be used for a nominal pressure up to 25 bar and in a permitted flow range of 10 to 150 cm/s. For simple startup of the flow sensor, there is a micro USB interface on the device and a setup program is available as an accessory. There is a button on the user interface for the setting of a switching point on site. Due to its robust design with protection type IP65/67, the flow sensor can also be used in difficult environmental conditions. The main areas of use are the monitoring of cooling water circuits, pumps, heat exchangers, leak monitoring for process lines, dry-run protection for pumps, as well as the monitoring of lubrication circuits. Type 406040 Customer benefits Configuration interface Simple connection to the JUMO PC setup is possible via the micro USB interface. Flexibility By turning the sensor 360, the measuring device can be installed in any installation position, independent to the direction of flow. Process reliability Different fittings and versions ensure simple and reliable connection. Special features Analog or switching output No moving parts Variable installation position of the sensor (can be rotated 360 ) Switching point is adjustable on-site

sales@jumo.co.uk info.us@jumo.net Page 2/9 Technical data Output Analog output flow sensor Basic setting Setting range Attenuation 0 s 0 to 99 s Scale start 10 cm/s 10 to 150 cm/s Scale end 150 cm/s 10 to 150 cm/s Behavior on error 3.4 ma 0, 3.4 or 22 ma Output signal 0(4) to 20 ma 0 to 20, 4 to 20, 20 to 0, 20 to 4 ma Switching output flow switch Basic setting Setting range Output behavior N/O contact N/O contact, N/C contact, window opening function, window closing function Switching point (Sp) 75 cm/s 10 to 150 cm/s Release point (Rsp) 60 cm/s 10 to 150 cm/s Switch-on delay 0 s 0 to 99 s Behavior on error switch off switch on, switch off Flow velocity Base measuring range 10 to 150 cm/s Measuring accuracy a ±10 % from base measuring range end value Temperature drift ±0.2 %/K from base measuring range end value Response time 4to10s to flow change a These specifications apply for a medium temperature of 20 C using a JUMO installation fitting and depend on the installation position Electrical data Voltage supply DC 24 V ±10 %, SELV Requirement The device must be equipped with an electrical circuit that meets the requirements of EN 61010-1 with regard to "Limited-energy circuits". Electromagnetic compatibility Acc. to DIN EN 61326-1 Interference emission Class A only for industrial use Interference immunity Industrial requirement Current consumption Analog output - flow sensor: 200 ma Switching output - flow switch: 400 ma

sales@jumo.co.uk info.us@jumo.net Page 3/9 Housing and environmental conditions Housing PA66-GF30 Pipe or process connection Stainless steel 316L, 316Ti (1.4404, 1.4571) Nominal pressure PN 25 Burst pressure 200 bar Weight Protection type according to EN 60529 Operation approx. 100 g (depending on the probe length) IP65 IP67 (only for sealed lid and cable box screwed on) Ambient temperature range -25to+70 C at the housing Medium temperature range -25 to +80 C (water or aqueous solutions, no abrasive media) Storage temperature range -25 to +80 C Resistance to climatic conditions Operation 100 % relative humidity including condensation of the housing Storage 90 % relative humidity without condensation Mounting position Horizontal or vertical, housing can be rotated On-site Setup interface Switching output variant: Button on the device to set the switching point Micro USB socket Block diagram Flow sensor USB PC Setup program Push-button Type 406040 Switching output PNP High Side Switch Indication Status LEDs Voltage supply DC 24 V, SELV Analog output 0(4) to 20 ma

sales@jumo.co.uk info.us@jumo.net Page 4/9 Setup program Function The setup program serves the configuration of the flow sensor using a PC. The configuration data can be archived on data carriers and printed. The setup program can be used to overwrite changed parameters with the default settings at any time. The connection between flow sensor and PC is established via a micro USB interface. Set the behavior of the outputs when the measuring range is exceeded Set the analog output function (optional) Set the switching output function (optional) The configuration of the flow sensor is possible without auxiliary energy via the micro USB interface. Display and control elements (1) (2) (3) (4) (1) Micro USB interface (3) Button (2) LEDs (4) Protective lid with viewing window (IP67) On: green LED Error: red LED O1: yellow LED

sales@jumo.co.uk info.us@jumo.net Page 5/9 Connection diagram The connection diagram in the data sheet provides preliminary information about the connection options. For the electrical connection only use the installation instructions or the operating manual. The knowledge and the correct technical execution of the safety information/instructions contained in these documents are mandatory for installation, electrical connection, startup, and for safety during operation. Connection for Type PIN Description Terminal assignment Analog output 1 +24 V 2 (1) 2 Analog output 1 2 +24V 3 4 3 GND 3 1 4 A 4 Not used GND Switching output 1 +24 V 2 2 Not used 3 1 4 3 GND 4 Switching output PC Micro USB interface a (Type B) 2 3 4 1 (2) +24V GND a The micro USB interface is designed only to configure the flow sensor. Continuous operation is not admissible.

sales@jumo.co.uk info.us@jumo.net Page 6/9 Dimensions Ø44 30.5 50 60 M12 x1 Ø33 L (a) L (b) (1) Ø6 (1) Union nut L12, M18 1.5; DIN EN ISO 8434-1, AF 22 Nominal pipe width Inside diameter-ø [mm] L (a) [mm] L (b) [mm] DN 40 38 bis 44,3 37 124 DN 50 50 bis 56,3 Conical plug PINOS L01 Threaded bore on process side M18 24 ±0.05 Ø12 24 ±0.05 8 Ø10.5 L1 L1+4,5 min. 8,5 min. 7 Ø8,5 ±0.5 min. 23 Sensor tip (center of pipe)

sales@jumo.co.uk info.us@jumo.net Page 7/9 Installation Mounting example (A) X (1) (1) Sensor alignment can be turned 360. Preferred direction: Flow is towards M12 connector (A) Centre of pipe (Alignment of the sensor tip to around the center of the pipe) X X X Do not use flow sensors in pipes which are open downwards.

sales@jumo.co.uk info.us@jumo.net Page 8/9 Order details (1) Basic type 406040 JUMO PINOS L01 calorimetric flow sensor (2) Basic type extension 000 None 999 Special version (3) Output 402 0to20mA, 3-wire 406 4to20mA, 3-wire 470 1x PNP switching output (4) Nominal pipe width 140 DN 40 150 DN 50 (5) Process connection 182 M18 1.5 internal thread with union nut (6) Extra code 000 None 100 Customer-specific setting (switching function, attenuation...) (1) (2) (3) (4) (5) (6) Order code / - - - / Order example 406040 / 000-406 - 140-182 / 000

sales@jumo.co.uk info.us@jumo.net Page 9/9 Accessories Item Part no. Setup program on CD-ROM, multilingual 00609195 Micro USB cable, type A USB connector on micro-b USB connector, length 3 m 00616250 4-pin cable box (straight) M12 1 with 2 m PVC cable 00404585 4-pin angled socket M12 x 1 with 2 m PVC cable 00409334 Welded socket a Optimized for PINOS version DN h ød 40 45 48.3 00659699 50 59 60.3 00659700 a Other variants for alternative pipe diameters available on request. Installation location A hole of Ø 20 mm must be drilled at the installation location and the welded socket welded on centrally. Welded socket M18 x 1.5 8.5 20 h 0.1 D