Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

Similar documents
STARTUP GUIDE. SP en-us ENGLISH

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

Anybus X-gateway EtherNet/IP

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE

Anybus.NET Bridge PROFIBUS

Anybus Communicator PROFINET

Anybus Wireless Bolt RJ45 PoE

Anybus.NET. using TIA Portal with PROFIBUS APPLICATION NOTE

Anybus Wireless Bridge II

Netbiter EC300 Series

REFERENCE GUIDE HMSI ENGLISH

Anybus CompactCom Starter Kit REFERENCE GUIDE

Enabling and Using OPC UA on Anybus CompactCom 40

STARTUP GUIDE SCM /SP ENGLISH

Anybus X-gateway USER MANUAL

USB RS232 Cable Converter

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO USER MANUAL ENGLISH

APPLICATION NOTE SCM ENGLISH

USER MANUAL en-us ENGLISH

FIP IO Slave. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting DevicesTM

KPI Configuration APPLICATION NOTE KB EN 1.0

Anybus Communicator CAN

How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT

CANbridge NT. 200 and 420 USER MANUAL EN 1.3

SOLUTION SHEET. KB en-us

NT. 200 and 420 USER MANUAL EN 1.4

USB-to-CAN V2. Compact Embedded Automotive Professional USER MANUAL ENGLISH

FR-IB100/PCIe. FlexRay PCI Express Interface Card USER MANUAL ENGLISH

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

NTP Client Server Relay

EtherCAT Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

USB-to-CAN FD. Compact Embedded Automotive USER MANUAL ENGLISH

Anybus Wireless Bridge

Anybus CompactCom 40 Diagnostic Events for EtherNet/IP

CANopen Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

Anybus CompactCom 40 Diagnostic Events for Modbus-TCP APPLICATION NOTE

INpact Slave PCIe. Profibus/PROFINET IRT Fiber Optic/CC-Link/DeviceNet USER MANUAL EN 1.5

INSTALLATION GUIDE en-us ENGLISH

X-gateway Interface Addendum CC-Link Slave Interface

INpact Slave PCIe. Industrial Ethernet PCIexpress Interface USER MANUAL ENGLISH

INpact Slave PCIe. Industrial Ethernet PCIexpress Interface USER MANUAL ENGLISH

User Manual Anybus Communicator for CC-Link IE Field

NT 200/420. Communication in Gateway Setup SOFTWARE DESIGN GUIDE ENGLISH

Anybus CompactCom Option Board Freescale

User Manual Anybus Serial Server

The Cosy 131 User Guide USER MANUAL

WAN Connection Fallback

Netbiter EasyConnect

Network Interface Appendix Anybus -CompactCom Passive RS-485/422

SOFTWARE DESIGN GUIDE AUG ENGLISH

Serial PROFIBUS Interface

Anybus Wireless Bolt RJ45 PoE USER MANUAL

NetBiter I/O Extender User Manual

ETHERNET/MFC 010 Technical Datasheet

Anybus CompactCom 40 Diagnostic Events for EtherCAT SCM ENGLISH

FLB G (Verizon) Extension Card INSTALLATION GUIDE

User Manual Anybus Modbus TCP/RTU Gateway

Anybus X-gateway Modbus-TCP PROFINET

RTU560 Remote Terminal Unit Connections and Settings

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Anybus X-gateway Modbus-TCP Modbus-TCP

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

User Manual Anybus Communicator CAN Modbus-TCP

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Anybus Wireless Bolt RJ45 PoE

Modbus TCP/RTU Gateway

Anybus CompactCom 40 Diagnostic Events for PROFIBUS APPLICATION NOTE

IXXAT CME/PN. CANopen-PROFINET Gateway HARDWARE MANUAL ENGLISH

User Manual Anybus Communicator CAN Modbus RTU

Anybus WLAN Access Point IP67 USER MANUAL

UA-5200 IIoT Communication Server

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Easy Commissioning via SD Card & USB Drive

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

User Manual Anybus Communicator for Modbus Plus

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

Operating and mounting instructions

EX-RC1 Remote I/O Adapter

DIN Rail RTU 540CMD01 Data sheet

Anybus X-gateway Modbus-TCP Modbus RTU

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

RTU560 Connections and Settings DIN Rail RTU 560CIG10

User Manual Anybus Communicator for DeviceNet

Anybus X-gateway Modbus-TCP PROFINET

DT7000 Communication I/O Gateway User s Guide Version 2.6

ControlNet Adapter. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting Devices TM

User Manual Anybus Communicator for EtherCAT

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

gigabit industrial ethernet user manual Models , ,

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Trusted Demonstration Unit

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

BACnet/IP to BACnet MS/TP Router

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Transcription:

Anybus Communicator IIoT STARTUP GUIDE ENGLISH

Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of any inaccuracies or omissions. The data and illustrations found in this document are not binding. We, HMS Industrial Networks AB, reserve the right to modify our products in line with our policy of continuous product development. The information in this document is subject to change without notice and should not be considered as a commitment by HMS Industrial Networks AB. HMS Industrial Networks AB assumes no responsibility for any errors that may appear in this document. There are many applications of this product. Those responsible for the use of this device must ensure that all the necessary steps have been taken to verify that the applications meet all performance and safety requirements including any applicable laws, regulations, codes, and standards. HMS Industrial Networks AB will under no circumstances assume liability or responsibility for any problems that may arise as a result from the use of undocumented features, timing, or functional side effects found outside the documented scope of this product. The effects caused by any direct or indirect use of such aspects of the product are undefined, and may include e.g. compatibility issues and stability issues. The examples and illustrations in this document are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular implementation, HMS Industrial Networks AB cannot assume responsibility for actual use based on these examples and illustrations. Intellectual Property Rights HMS Industrial Networks AB has intellectual property rights relating to technology embodied in the product described in this document. These intellectual property rights may include patents and pending patent applications in the USA and other countries. Anybus is a registered trademark of HMS Industrial Networks AB. All other trademarks mentioned in this document are the property of their respective holders.

Preface 3 (12) 1 Preface 1.1 About This Document This document describes how to install the Anybus Communicator IIoT. For additional documentation and software downloads, FAQs, troubleshooting guides and technical support, please visit www.anybus.com/support. 1.2 Document Conventions The following formatting conventions are used in this document to indicate safety information and other content of specific importance: WARNING This instruction must be followed to avoid a risk of death or serious injury. Caution This instruction must be followed to avoid a risk of personal injury. This instruction must be followed to avoid a risk of reduced functionality and/or damage to the equipment, or to avoid a network security risk. This is additional information which may facilitate installation and/or operation.

Installation 4 (12) 2 Installation 2.1 Installation Overview Prerequisites The following items are required for installation and basic configuration: Configuration cable Subnetwork cable Ethernet cable Anybus Configuration Manager - Communicator RS-232/422/485 (4.5.0.0 or later) Anybus Configuration Manager - IIoT IPconfig (3.2.1.1 or later) The Anybus Configuration Manager and IPconfig applications can be downloaded from www.anybus.com/support. Basic installation steps 1. Mount the Anybus Communicator on the DIN rail. 2. Connect the serial and IIoT network interfaces. 3. Connect the configuration cable between the gateway and a PC. 4. Connect the power cable and apply power. 5. Check the LED indicators to verify that the gateway is running and that the serial and IT networks are connected. See LED Indicators, p. 9. 6. Use Anybus Configuration Manager - Communicator to set up the data exchange configuration in the Anybus Communicator. 7. Use IPconfig to configure the TCP/IP settings for the Anybus Communicator. 8. Use Anybus Configuration Manager - IIoT to create a tag configuration and transfer it to the Anybus Communicator. 9. Connect to the web interface of the Anybus Communicator and configure MQTT/OPC UA communication.

Installation 5 (12) 2.2 DIN Rail Mounting The unit must be electrically grounded through the DIN rail for EMC compliance. Mount on DIN rail Fig. 1 Push down to mount or remove 1. Hook the unit onto the upper lip of the rail and push gently downwards. 2. Push the unit towards the rail until it snaps into place. Remove from DIN rail 1. Push the unit gently downwards on the rail. 2. Pull the bottom end of the unit free of the rail and remove it.

Installation 2.3 6 (12) Connectors and Indicators 2.3.1 Overview Fig. 2 Overview 1 LED indicators 2 DIN rail mount 3 Power connector 4 Serial subnetwork interface 5 PC connector 6 IIoT network interface Anybus Communicator Startup Guide

Installation 7 (12) 2.3.2 Serial Subnetwork Interface Fig. 3 D-sub connector (DE-9F) Pin Description RS-232 RS-422 RS-485 1 +5 V Output (100 ma max.) x x x 2 RS-232 Rx x 3 RS-232 Tx x 4 (reserved) 5 Signal Ground x x x 6 RS-422 Rx + x 7 RS-422 Rx - x 8 RS-485 + / RS-422 Tx + x x 9 RS-485 - / RS-422 Tx - x x Housing Shield x x x Do not connect Signal Ground to Protective Earth (PE) of other nodes on the subnetwork as this may damage the on-board serial transceivers. Connect it only to the Signal Ground on other nodes. Bias and/or termination resistors may be required depending on the type of serial network. Please refer to the User Manual for more information.

Installation 8 (12) 2.3.3 Power Connector (2 pin) Connecting power with reverse polarity or using the wrong type of power supply may damage the equipment. Make sure that the power supply is connected correctly and of the recommended type. Pin Signal 1 +24 VDC 2 Power Ground 2.3.4 PC Connector (RJ11) Pin Signal 1 GND ( signal ground) 2 GND (signal ground) 3 RS-232 Rx (input) 4 RS-232 Tx (output) 2.3.5 Ethernet Connector (RJ45) Pin Signal Description 1 TD+ Transmit data + 2 TD- Transmit data - 3 RD+ Receive data + 6 RD- Receive data - 4,5,7,8 - (reserved)

Installation 9 (12) 2.4 LED Indicators 1 2 3 4 5 6 LED 1 to 4 LED 5 LED 6 Model-specific information Serial subnetwork status Device status LED Indication Meaning Off Offline or no power Green Online, IP address assigned 1 - Network Status Green, flashing No IP address assigned or no link Red Fatal error, IP address conflict Alternating Red/Green Firmware update in progress Off No power or IP address conflict 2 - Module Status Green Normal operation Red Fatal error Alternating red/green Firmware update in progress Off Link not detected or no power Green Link established (100 Mbit/s) 3 - Link/Activity 1 4 - Link/Activity 2 Green, flickering Link activity (100 Mbit/s) Red Link established (10 Mbit/s) Red, flickering Link activity (10 Mbit/s) 5 - Subnet Status Off No power Green Running Green, flashing Running, one or more transaction errors Red Transaction error/timeout or subnet stopped 6 - Device Status Off No power Green Initializing Green, flashing Running Red Bootloader mode Alternating red/green Configuration invalid or missing The Link/Activity LED indicators will show a red light for 10 Mbit/s connections. This is normal and does not indicate an error.

Technical Data 10 (12) 3 Technical Data 3.1 General Specifications Model name Anybus Communicator IIoT Order code AB7079-B Dimensions (L x W x H) 120 x 75 x 27 mm Weight 150 g Operating temperature 0 to +55 C (IEC 60068-2-1 and IEC 60068-2-2) Storage temperature -40 to +85 C (IEC 60068-2-1 and IEC 60068-2-2) Humidity range 5 95 % RH, non-condensing (IEC 60068-2-30) Power supply 24 V ±10 % DC regulated power source Current consumption Typical: 100 ma @ 24 VDC Maximum: 200 ma @ 24 VDC Galvanic isolation Yes, on both network sides Mechanical rating IP20, NEMA rating 1 Mounting DIN rail (EN 50022) Network shield conductance via DIN rail Certifications See datasheet at www.anybus.com/support 3.2 Serial Interface Serial application Interface Maximum number of stations Protocol: Modbus RTU Protocol: ASCII/Vendor Specific Protocol: Rockwell DF1 Selectable RS-232, RS-422, RS-485 31 nodes via RS-422 or RS-485 Modbus RTU Master - Query/Response Request/Response or Produce/Consume DF1 Master

Technical Data 11 (12) 3.3 IIoT Interface OPC UA functionality Support for micro-embedded profile Supports Discovery Services Timestamp supported via discovery server User name and password authentication Supports DataChange Subscription Maximum 80 data point tags (max. 2 clients with up to 40 tags per client) MQTT functionality MQTT client acting as publisher MQTT version 3.1.1 supported Json data encoding supported QoS 0-2 supported User name and password authentication Maximum 256 data point tags Ethernet 100 Mbit/s, full duplex (fixed) Dual port cut-through switch, RJ45 connectors

last page 2018 HMS Industrial Networks Box 4126 300 04 Halmstad, Sweden info@hms.se / 2018-11-22 / 10688