MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Similar documents
Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

Operating Instructions. Isolation Relay for Switches Model: RL manual_rl-6100_1116

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

Safety Control Relay Product Catalog

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

LC-5 Level Controller & Flow Monitor

Operating Instruction for Rotating Vane Flow Meter. Model: DRG-...

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Operating Instructions for Level Switch for Liquids. Model: RFS

ALTERNATING RELAYS & CONTROLLERS ARM Series

KOBOLD Compact Electronics

Masibus Automation And Instrumentation Pvt. Ltd.

LC-1 Level Controller & Flow Monitor

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

Operating Instructions for Digital Thermometers. Model: DTM

Remote Relay Controller LC40, LC41 and LC42 Series Owner s Manual

Tempco Instruction Manual

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

PHASE MONITOR RELAYS Product Summary

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Latching, Sequence and Impulse Relays Application Data

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Bulletin 817 Thermistor Protection Relay

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

SMART SHOT CONTROLLER FLUID USERS GUIDE

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

2 Channel POTS with I/O DIN Fiber Link System

Operating Instructions for Vibrating Level Switches. Model: NVI

SS2200 Remote Controller

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Differential Pressure Sensor. Model: PMP

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

ZC Series Zone Monitoring Controllers

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Safety control unit B1 / B1. for 2 to 16 machine safety sensors. Use. Types. + PLd according to EN ISO

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Model 7705 Control Module

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

User safety and equipment protection guidelines

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

SP SP-T-9

700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

PGR-3200 MANUAL INSULATION MONITOR

Operating Instructions for Rotating Vane Flow Meter. Model: DRH-...

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Magnetically Actuated Safety Interlock Switches

Safety controller unit B1 /

IPS INTELLIGENT PUMP STARTER

MODELS DPDT DPDT DPDT-60MS DPDT-60MS

Advantages of a Full Featured 700 Series Relay

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

MODEL SIB-V245 / V453

External level devices for conductive point level switch

Manual Simatek Control Unit GFC 32

H3CA-8H-AC/100/110/120

INSTALLATION INSTRUCTIONS

700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

78 Series Electromechanical Relay Selection Guide

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Machine Safety Switches

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

OPERATOR S MANUAL 9000U ISOLATOR

Manual Control Unit GFC 32

seal leak & temperature relays

Safety Monitoring Relays

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Series 8000 RF Signal Switch Solution

Serial Data DIN Fiber Link System

Level gauges Series LS Level indicator, switch and transmitter for liquids

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Instruction Manual August milltronics ZSS

TIME DELAY RELAYS Product Summary

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

Safety Relay Unit (I/O Unit Type)

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Transcription:

Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8

1. Note Please read and take note of these operating instructions before unpacking and commissioning. The instruments may only be used, maintained and installed by qualified personnel familiar with the operating instructions and the applicable health and safety requirements. 2. Contents 1. Note 2. Contents 3. Specific Application 4. Operating Principles 5. Instrument Inspection 6. Mechanical Installation 7. Technical Specifications 8. Electrical Connections 9. Start-Up 10. Troubleshooting 11. Maintenance 3. Specific Application The Level Control Module has been designed for use in level monitoring applications and pump control for liquids. The module consists of a transformer, control logic circuit and output relay. Type MSR 1122 is a bi-stable latching type control module with SPDT relay contact output. Inputs should be dry (potential free) contacts, for example, reed switch from float type level detector. The module generates 24 VDC to detect input switch closure; the current is limited to 20 ma on the inputs, in order to protect the level switches. In addition the module has built in time delay on the inputs which avoids false triggering due to switch bounce or nuisance tripping from process vibration, waves or bubbles. 4. Operating Principles The module is designed to provide detection of two levels in a process tank and to control the tank level in either a pump-up or pump-down mode of operation. This module can also be used as a contact isolation relay to isolate low current, pilot duty contacts from high current loads. Pump-Up Mode In a pump-up mode, the relay will initiate by switching on the pump when the fluid level in the tank falls below the lower tank level switch. The relay will remain energized (latched) and the pump will continue to operate until fluid fills the tank up to the high level switch. When the fluid reaches the high level switch the control module relay will de-energize and shut off the pump. The control module relay will remain de-energized until the fluid falls below the low tank level switch. Pump-Down Mode In a pump-down mode, the relay will initiate by switching on the pump when the fluid level in the tank reaches the upper tank level switch. The relay will remain energized (latched) and the pump will continue to operate until fluid in the tank empties down to the low level switch. When the fluid falls below the low level switch the control module relay will de-energize and shut off the pump. The control module relay will remain de-energized until the fluid level reaches high tank level switch. MSR Operation Instructions Rev. Apr 07 Page 2/8

Contact Isolation Mode In the contact isolation mode, the relay will mimic the function of a contact wired between input pins 12 and 13. If this contact closes, the relay will switch-over and continuity will exist between relay output pins 42 and 43. If this contact opens, the relay will switch back and continuity will exist between relay output pins 42 and 41. 5. Instrument Inspection The instruments are thoroughly inspected by the factory prior to shipment, and sent in perfect condition. Should any damage to the device be visible, we recommend a thorough inspection of the delivery packing. In case of damage please inform your parcel service/forwarding agent immediately, since they are responsible for damages incurred during transit. Scope of delivery: Level Control Relay Module Operation Manual 6. Mechanical Installation The relay module enclosure is rated IP 20 (approx. equivalent to NEMA 1) which is intended to be used in a dry, dust-free environment. If the relay module will be located in harsh, wet or dusty environments, the user should mount the module in an appropriate enclosure to protect the device. The relay module is mounted on to an electrical panel using standard 35mm DIN mounting rail, according to DIN 50022. The device snaps on to the DIN rail, and can be removed from the rail by releasing the spring loaded clip, located on the bottom of the device. MSR Operation Instructions Rev. Apr 07 Page 3/8

7. Technical Specifications Technical Data: Device Type Electromechanical Contact Protection Relay Model MSR-1122 Housing Dimensions mm 75 x 50 x 97 Housing material Polyamide 6.6 Supply Voltage Model number suffix PO3: 115 VAC ±10%, 50-60 Hz Model number suffix PO4: 230 VAC ±10%, 50-60 Hz Power Consumption 5 VA (typical) Control Voltage 24 VDC Control Current 20 ma Input Impedance 3300 Ohm, 100 nf ±20% Maximum Contact ON Impedance 4700 Ohm, 47 nf at inputs Delay Period (initiating) 10 ms Delay Period (dropping) 20 ms Output 1 SPDT relay contact Permissible Load 250 VAC / 8 A resistive / 1840 VA Temperature Range -20 C to 60 C Type of Protection IP 20/NEMA 1 Specifications subject to change. Dimensions: MSR Operation Instructions Rev. Apr 07 Page 4/8

Electrical Connection ATTENTION! Ensure that the voltage levels of your supply system are in agreement with the voltage levels given on the type label of the device. Make sure that the electric supply lines are not active during connection to this device. Improper wiring can lead to damage of this device as well as injury to the user. Make sure that installation, wiring, and circuit protection are in accordance with all local electrical codes. Make sure the supply circuit provides adequate fuse or circuit breaker protection that is in accordance with the circuit s current rating. Make sure that a motor contactor relay or starter is used to energize the pump circuit if the pump s current rating exceeds the MSR Level Control s relay rating. Wiring Table Terminal # Description Function A1 Line Power Connection Connect to 115 VAC supply A2 Line Neutral Connection Connect to Mains Neutral Supply 12 Sensor input common Connect to one side of switches 13 START Input Momentary Closure of 12 and 13 Energizes Output Relay (Latched) 11 STOP Input Momentary Closure of 12 and 11 De-Energizes Output Relay (Reset) *Note: To operate the relay in contact isolation mode, jumper pins 12 to 11 and connect control contact to pins 12 and 13 42 Relay Output Common 41 Relay Output N/C Normally Closed Contact When relay energized: 42 and 41 Open 43 Relay Output N/O Normally Open Contact When relay energized: 42 and 43 Close 82 & 81 24 VDC Excitation Sensor supply (Maximum 20 ma!) A1 42 12 13 11 L N 12 I DC 13 --I 11 - + 41 43 82 81 A2 MSR Operation Instructions Rev. Apr 07 Page 5/8

START & STOP: Hi and Low Level Contacts Located on Tank Start Stop Note: When using Kobold Multi-Point Level Switches Model NCG and NCM A1 42 12 13 11 L N DC I - + 12 13 11 --I Pump-Up (tank-fill) Application: Start= Bottom Position N/C (Dry) Stop= Top Position N/O (Dry) Pump-Down (tank-drain) Application: Start= Top Position N/O (Dry) Stop= Bottom Position N/C (Dry) Kobold recommends including backup safety switches, example Hi Level Alarm for overflow protection, in the event of pump or circuit failure. 41 43 82 81 A2 115 VAC 50-60Hz Mains Supply LOAD Wiring Diagram for Pump Control* *Suggested typical setup Subject to customers final verification & approval All Specifications subject to change MSR Operation Instructions Rev. Apr 07 Page 6/8

Note: For contact isolation mode, jumper pins 11 and 12. Wire input contact to pins 12 and 13. L 42 12 13 11 Input Contact Closed: Output relay continuity between pins 42 and 43. I L N DC 12 13 --I Input Contact Open: Output relay continuity exists between pins 42 and 41. 11 - + 41 43 82 81 N 115 VAC 50-60Hz Mains Supply LOAD Wiring Diagram for Contact Isolation *Suggested typical setup Subject to customer s final verification & approval All Specifications subject to change MSR Operation Instructions Rev. Apr 07 Page 7/8

8. Start-Up Ensure that all wiring to the Level Control Relay Module is correctly installed, and the level switches are installed and functioning correctly. The Relay Module is now ready for operation, and the supply power to the level control circuit can be applied. Depending on whether the module is wired for pump-up or pump-down mode of operation, the relay should operate in accordance with the description in section 4 - Operating Principles. 9. Troubleshooting The relay does not operate: Check that supply voltage is applied to the L (A1) and N (A2) terminals on the module. Check for 24 VDC across terminals 82 and 81. If supply voltage is applied and 24 VDC is not measured across 82 and 81, the module may be faulty. Check level switch operation and cabling from the tank location to the module. Temporarily remove the switch inputs from the module and simulate level switch closure by using jumper wires across input terminals. When simulating level switch closures the relay does not activate, the relay may be faulty. If the relay activates, but does not start the pump, the output wiring or pump circuit may be faulty. 10. Maintenance The Level Control Relay Module requires absolutely no maintenance. Depending on the type of level sensors used and the process conditions, maintenance to the sensors may be required. Verify and follow maintenance procedures according to the sensor maintenance manual. Verify and follow maintenance procedures according to the pump manufacturer s maintenance manual. There are no user serviceable parts inside the Type MSR module. If repair is required please contact your local Kobold sales office to arrange a return for repair. Kobold Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 TEL: 412-788-2830 FAX: 412-788-4890 www.koboldusa.com MSR Operation Instructions Rev. Apr 07 Page 8/8