Modular High Power UPS for large data centres Hot scalable up to 2.67 MW Ultimate scalability and flexibility

Similar documents
3-L Green Conversion. Compact footprint

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10kVA

Critical Power 2017 Catalogue

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

PowerWAVE 9250DPA. ( N+1 kva/kw) Parallelable up to 1.5 MVA/MW

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

the Centric 300 An advanced modular UPS up to 1800kVA/kW

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Modular UPS for large data centers 400 kw to 1.6 MW with innovative green technology for unmatched energy savings

Eaton 9EHD Industrial UPS

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Tel: AC Power for Business-Critical Continuity TM

Est FlexiPower Maxi UPS FPX Maxi kVA

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 20kW 600kW

The Power of Modularity

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Product brochure. Conceptpower DPA Modular UPS DPA 120 UL 208V: 20kW 600kW

Est ComPower Mini. Compact UPS kva

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

PRODUCT BROCHURE. Conceptpower DPA V UL Modular UPS 100kW 3MW

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

TME Modular Series UPS System kva/kw - 208/220 VAC

Multi Power x 42 kw up to 1 MW + redundancy 3:3 VFI TYPE. Utmost Availability Ultimate Scalability Unmatching Power Density

Est FlexiPower Ultra UPS FPX Ultra kVA

GAMATRONIC, A SolarEdge Division.

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

Est FlexiPower Maxi. Modular UPS kw

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

MP7. Uninterruptible Power Supply

Eaton 9EHD Industrial UPS

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

Eaton 93PM UPS kw

Galaxy VX. From 500 kw to1500 kw N+1 Parallel solutions up to 4000 kw 480 V. schneider-electric.com

MUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA

Business continuity made easy

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

SR Plus series. on-line. SR20 Plus SR20T Plus. SR60 Plus LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS. Industrial PLCS

Liebert SX TM. 60kVA to 200kVA UPS Three Phase Input, Three Phase Output

PowerWAVE 9000DPA. (30-50 kva) Parallelable up to 1.5 MVA

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

Liebert NXC from 10 to 60kVA

Schneider Electric Easy UPS 3S

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

MGE Galaxy /300/400/500 kva Power efficiency for business continuity. schneider-electric.com

Eaton 93E UPS Simple power management for every IT environment.

Liebert EXL TM S kw to 1200 kw. Enhanced Design and Improved Efficiency

MODULAR UPS SYSTEM KVA

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

SystemTrust is the authorized distributor and partner of Borri UK in Nigeria

Multi Power x 42 kw up to 1 MW + redundancy 3:3 VFI TYPE

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

LP 33 Series UPS. Digital Energy. GE Digital Energy

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Schneider Electric Easy UPS 3S

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

MGE Galaxy /900 kva

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Modular UPS S KVA

Liebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM

Chloride Trinergy from 200 to 1200 kw

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Converged Power Solutions. Data center power reinvented

SMARTONLINE E3 UPS SYSTEMS

The Modular UPS and Lithium-Ion Battery Combo - Raising the bar for Datacentre Critical Power. Alex Emms Operations Director

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Multi Power kw + redundancy kw 3:3 VFI TYPE

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Chloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System

UPS. ARCHIMOD UPS MODULAR THREE-PHASE from 20 to 120kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

SATURN DATACENTER & SERVERS TELECOMMUNICATION DEVICE INDUSTRIAL APPLICATION TRANSPORTS. Smart Energy Solutions

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

UPS TRIFASE kVA Rev. 8 Serie TPH IGBT

Kohler EW 6000TX. Transformer-based. (UPS kVA)

Power Quality Solutions Eaton 93PR UPS

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Eaton kva Eaton kva Scalable. Compact. Flexible

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

Socomec Netys PR RT U P S TOWER / RACK MOUNT

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

PowerWAVE 9500DPA. ( kva/kw) Parallelable up to 3 MVA/MW

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

ZP 120 N. UPS 1,2,3,6,10,20 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Modular, scalable, high-efficiency power protection for data centers

Transcription:

Modular High Power UPS for large data centres Hot scalable up to 2.67 MW Ultimate scalability and flexibility

Modular, scalable and adaptable high power UPS s for Enterprise Data Centres and IT business critical applications, designed for the changing demands of your Data Centre with the Lowest Total Cost of Ownership (TCO). Highlights 98.5% average efficiency (VFI 97%) and 4 high efficiency operating modes. Hot scalable 333 kw modules up to 2.67 MW in a single unit. Power parallel scalable up to 21 MW. Very small footprint and 572 kw/m 2 power density. System design flexibility. Total installation adaptability. VRLA, Li-Ion and Fly-Wheel compatible. Solutions for peak shaving. 10 colour touch screen display. Reduced TCO Reducing your Total Cost of Ownership (TCO) is our goal. How UPSaver 3vo helps your CapEx: Pay as you grow thanks to hot scalability. Tailored to the room layout thanks to total design and installation flexibility. Minimal spare parts thanks to sub-modularity. How UPSaver 3vo helps your OpEx: Quick upgrade and maintenance thanks to hot scalability and serviceability. Adapts to load requirement thanks to automatic power control. Always delivering maximum efficiency thanks to 4 high efficiency operating modes. Higher efficiency also means less cooling thus reducing your CO 2 footprint. Applications Data centres Cloud Networking services Telecommunication equipment Critical cooling

98.5% Average Efficiency Borri UPSaver 3vo delivering unsurpassed system efficiency for maximum availability and cost saving. Adaptive capability and automatic power control to maximize the system efficiency while maintaining full system reliability thanks to Load Based Shutdown algorithm. 3-L patented Green Conversion technology Latest generation IGBT. UPS life extension. Battery life extension. Double High Efficiency: all the on-line double conversion protection (VFI-Voltage frequency independent mode), at 97% efficiency with Borri patented Green Conversion technology. ECO mode: suitable for stable mains, in VFD (Voltage Frequency Dependent) mode of operation achieving 98% efficiency. Very High Efficiency*: maximum efficiency in unstable mains conditions with Active Filtering, the Borri VI (Voltage Independent) mode of operation achieving 97.5% efficiency. Ultra High Efficiency*: the most innovative technology for data centre equipment total protection with 99.5% efficiency and minimum total cost of ownership. Revolutionary Current Parallel of Modules No circulating currents. No system efficiency reduction. Stable high power parallel system. No stress on battery and power components. Distributed redundancy is easily achieved. 4 dynamic operation modes High efficiency double conversion VFI. Enhanced Active Filtering VI. Energy saving ECO mode VFD. Ultra High Efficiency mode VFD. * conditions apply 97% VFI efficiency at any load 100% 95% 90% 85% 80% 10 20 30 40 50 60 70 80 Load Based Shutdown algorithm optimizes the number of active modules to maximize system efficiency. This enables the UPS to adapt to load requirement, whilst keeping highest VFI protection. Energy saving at data centre typical operation. Extended service life. Enhanced module performance. Operational and TCO peace of mind. Efficiency with Load Based Shutdown algorithm Efficiency

3D Scalability Hot VFI scalability up to 2.67 MW in a single unit, up to 21 MW in a parallel system and synchronized dual feed systems. Flexible power upgrade X- Hot Swap Module Scalability to 2.67 MW. Y- Parallel Power Scalability up to 21 MW. Z- Availability Scalability for distributed redundancy. Designed for versatility UPSaver 3vo is an extremely versatile system, allowing for any maintenance or power resizing to be carried out while units are online. Top or bottom entry for cables or busbar and adaptive terminal boards ensure robust design in any data centre electrical infrastructure. Y Scalability X Scalability Z Scalability Minimised Service Time Hot VFI swappable in minutes for lowest MTTR Sub-modules can be individually extracted for service purposes while the UPS is protecting your critical load in VFI mode. Replacing all power components and no firmware to update All serviceable components are fitted in sub-modules and no firmware to update upon replacement, ensuring Periodical Preventive Maintenance in no time. Minimal spare parts: one fits all Same sub-module up to 2.67 MW allowing you to secure the whole range of units with minimal spare part set.

Design Flexibility Distributed Static Bypass Distributed Battery for unparalleled modularity Each 333 kw module is equipped with a static bypass switch and a dedicated battery bank. The highest system flexibility for maximum adaptive capability to variable IT space. Distributed Static Bypass Central Battery for minimum floorspace Each 333 kw module is equipped with a static bypass switch. A single battery bank is connected to the UPS. DC isolation with string separators can be used to ensure live maintainability. The most cost effective and space saving modular solution. Central Static Bypass Distributed Battery for enhanced short circuit protection A central static bypass switch is fitted, sized for the whole UPS power. Each 333 kw module is equipped with a dedicated battery bank. This ensures high fault current which might be needed when the UPS is installed next to the MV/LV switchboard. Central Static Bypass Central Battery minimum MTTR maximum selectivity A central static bypass switch is fitted, sized for the whole UPS power and a single battery bank is connected to the UPS. DC isolation with string separators can be used to ensure live maintainability. The robustness of a standalone UPS in a modular layout, for minimum MTTR and maximum selectivity performance.

Optimised Footprint Extreme layout flexibility allows you to free space up for other equipment or overcome room constraints like pillars, walls or other devices. UPSaver 3vo is designed around your new or existing data centre. Careless Positioning Flexible layout. No rear or side access. Top or Bottom Cable Entry. 572 kw/m 2 power density. Constraint-free layout 333 kw modules are connected to the I/O unit by internal flexible connections, allowing constraint-overcoming positioning like packed layout, L-shape layout, offset layout and more. Offset layout L-shape layout Packed layout

UPSAVER 3vo technical data Input Output Rating (kva) 670 1000 1340 1670 2000 2340 2670 N nominal power (kw) 670 1000 1340 1670 2000 2340 2670 No. of modules 2 3 4 5 6 7 8 UPS dimensions WxDxH (mm)* 2450x970x2100 3050x970x2100 4100x970x2100 4700x970x2100 5700x970x2100 (***) (***) UPS weight (kg)* 1800 2540 3170 3900 4700 (***) (***) Battery configuration Connection type Nominal voltage Voltage tolerance Frequency and range External 360 to 372 cells, VRLA (other options) Hardwired 4w (rectifier), 4w (bypass) 400 Vac 3-phase with neutral (rectifier), 380/400/415 Vac 3-phase with neutral (bypass) -20%, +15% (rectifier); ±10% (bypass) 50/60 Hz, 45 to 65 Hz Power factor 0.99 Current distortion (THDi) <3% Connection type Nominal voltage Frequency Voltage regulation (VFI) Power factor Overload capability Hardwired 4w 380/400/415 Vac 3-phase with neutral 50/60 Hz Static: ±1%; dynamic: IEC/EN 62040-3 Class 1 Any power factor (leading or lagging) up to 1, without power derating Inverter: 125% for 10 min, 150% for 1 min; bypass: 150% continuous, 1000% for 1 cycle AC/AC efficiency** Up to 99.5% Classification as per IEC/EN 62040-3 Connectivity and function extensions System Front panel Remote communication Optional features VFI-SS-111 10 colour touch screen display, 1024x600 pixels Included: serial RS232 and USB; input terminal block (remote emergency power off, battery circuit breaker aux. cont., external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont., external output circuit breaker aux. cont., remote transfer to bypass mode); SPDT contact relay board; ModBus-RTU (RS485); Optional: ModBus-TCP/IP (Ethernet); ModBus-RTU to PROFIBUS DP adapter Isolation transformer; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit; load-sync for single UPS and load-sync box (2 UPS systems); other options on request Protection degree IP 20 Colour RAL 9005 Installation layout Accessibility Parallel configuration Wall, back to back and side by side installation allowed Front and top access, bottom and top cable entry Up to 8 UPS, for a total of 21 MW * referred to distributed battery, distributed static switch, bottom cable entry. For other configurations contact our sales team ** according to IEC/EN 62040-3 *** contact our sales team Other features Environmental Operating temperature Storage temperature Altitude (AMSL) Audible noise at 1m (dba) Standards and certifications Quality assurance, environment, health and safety 0 C to +40 C -10 C to +70 C < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m <50 (UHE) Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Environmental aspects IEC/EN 62040-4 Test and performance IEC/EN 62040-3 Protection degree IEC 60529 Marking ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 CE

Borri Headquarters and Factory Borri Subsidiaries and Service Centres Who we are Borri S.p.A Via 8 Marzo, 2 52011 Bibbiena (AR) Italy Tel. +39 0575 5351 Fax +39 0575 561811 info@borri.it For more information, visit our website: www.borri.it Asia Pacific Borri Asia Pacific Engineering Sdn. Bhd. No.13, Jalan Serendah 26/41, Sekitar 26, Seksyen 26, 40400 Shah Alam, Selangor Malaysia Tel. +60 3 5191 9098 Fax +60 3 5103 8728 sales@borri-asia.com Canada Borri Power Systems North America Inc. 205-3689 E 1 st Ave. Vancouver, BC V5M 1C2 Canada Tel. +1 604 439 3054 Fax +1 604 439 3053 info@borripower.com Germany Borri Power Germany GmbH Gewerbestraße 10 26789 Leer Germany Tel. +49 491 99 75 61 83 Fax +49 491 99 75 61 84 info@borri.de service@borri.de India Borri Power India Pvt. Ltd. Plot No. 69, Ground Floor Nagarjuna Hills, Panjagutta Hyderabad, 500 082 India Tel. +91 40 2335 4095 info@mea.borripower.com Middle East and Africa Borri Power Middle East FZCO 1-151, Techno Hub PO Box: 342036 Dubai Silicon Oasis, Dubai UAE Tel. +971 4 3200528 Fax +971 4 3200529 info@mea.borripower.com USA Borri Power (US) Inc. 9000 Clay Road, Suit 108 Houston, Texas, 77080 USA Tel. +1 346 212 2686 Fax +1 346 980 8875 info@borripower.com Borri Group is a global provider of power electronics systems and solutions for harsh industrial and demanding commercial and ICT secure power requirements merging over eighty years of experience in developing, manufacturing and supplying uninterruptible power systems and solutions. The Research and Development Team s expertise combines AC and DC power technologies spanning the worlds of both conventional and renewable energy, to provide innovative solutions for tomorrows problems. The company is comprised of three business units: Industrial Power, Critical Power and Renewable Power, headquartered in Bibbiena, Italy. Borri s latest products, based on Green Conversion operation, guarantee the best PUE for green data centres: proof of the ongoing company commitment to innovation. Thanks to its highly skilled custom engineers Borri controls in-house the entire process: from feed studies to design, production and after-sales service guaranteeing state-of-the-art solutions. Based in Italy with over 20,000 m² production area and a large high power test field, Borri can depend on its more than 80 years of experience and multidisciplinary research and development to serve our customers best. OMG60285revC - 04-2019 - Due to our policy of continuous development, data in this document is subject to change without notice and becomes contractual only after written confirmation