SVO CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITHOUT NEUTRAL

Similar documents
User s manual. Programmable panel meter IPD

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Interface Relay CRINT-1x

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM4JA01F current measurement relay RM4-J - range ma V AC

MIC-2 Multi-instrument DATA SHEET

Zelio Control-modular measurement and control relays 1

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

MCX08M2 Programmable controller

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35TF V AC

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Process displays For current and voltage

MIC-2 MKII, Multi-instrument DATA SHEET

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RM17UB3. Price* : USD

APP 700 Technical Specification

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM4TA32 three-phase network control relay RM4-T - range V

Zelio Control Measurement Relays Multifunction 3-phase supply control relays RM17T 00

RM4UA33M voltage measurement relay RM4-U - range V V AC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RM4TR31 three-phase network control relay RM4-T - range V

Programmable Relay ZEN V2 Units

ISOMETER isoev425/isoev425hc with coupling device AGH420

E-STOP relays, safety gate monitors

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RM4LA32M liquid level control relay RM4-L V AC

RM35LM33MW liquid level control relay RM35-L V AC/DC

Multifunction Transducer MT440

TF501, TF521 Terminal Bases

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

ISOMETER isopv with coupling device AGH-PV

Product and functional description

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

02/11/2015

Model Number Structure

MDC-20. Maximum Demand predictive Control. Description

ISOMETER isoev425 with coupling device AGH420

PointMaster 100. Multipoint Recorder 10/ EN

E-STOP relays, safety gate monitors

RM4JA31M current measurement relay RM4-J - range ma V AC

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Time Counters mini "h", DC Version

Electronic monitoring relays PMDsrange

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

20 General technical data XI/ON

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Signal Doublers. VariTrans A 20300

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

AI561 Analog Input Module

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

E-STOP relays, safety gate monitors

Monitoring Relays MRU, MRI, MRM

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

TECHNICAL MANUAL DC-41SRTHONE+R

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

SensoTrans DMS A 20220

Programmable controller MCX06C

BL compact Fieldbus Station for DeviceNet 4 Analog Current Outputs BLCDN-4M12LT-2AO-I-2AO-I

Output Voltage* (nom.)(adjustable)

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Syr-line TMR48D Digital Timer

Energy Management Energy Transducer Type ET112

AO523 Analog Input Module

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Output Voltage* (nom.)(adjustable)

Model Number Structure

Technical Information Promonitor NRF560

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Voltage Transducer UMT516 / MT516

MCX06C Programmable controller

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Hotel Room Controller

Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

InCos-P Pressure sensor 20 Pa Pa

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

RUC industrial relays of small dimensions

Digital multimeters DMG

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Transcription:

1/5 CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITHOUT NEUTRAL Function Operating mode Voltage control Phase sequence control Control of the phases unbalance Frequency control Timing Voltage precision Frequency precision Display of the reading value Output relay Output 4-20 ma PC communication Warning Voltage relay for three-phase lines without neutral. Control of an auxiliary voltage or of its own supply voltage. Configurable by the user. Each one of the available relays it is assigned with its own operating mode for one or more magnitudes, reacting by the first one which is produced. Operating margin: ±18% of the nominal voltage. Operativity by maximum and/or minimum voltage between phases.independent adjustment L1-L2, L1-L3 and L2- L3. At each case, adjustment for detection and/or for release. Reading value RMS It is detected that the phases come in the correct order. Adjustable from 0 and 100%. Only one adjustment for the three phases. Adjustable from 43..70 Hz. Operativity by maximum and/or minimum frequency. At each case, adjustment for detection and/or for release. If the frequency changes in such a value that the relay loose the required precision for a normal operating mode, it switches to the alarm mode (See page 4 for detailed information). Associable to the detection and/or to the release of whichever relay. Adjustable from 0,01s..999,9h Repeating precision ±30 ppm Taken over the read value: For L1-L3 and L2-L3: At 50Hz: 0,8% At 60Hz: 1,0% For L1-L2: At 50Hz: 0,9% At 60Hz: 1,1% Taken over the read value: 0,3% The value of the read magnitudes is displayed by means of the following status screen: VOLTAGE L1-L3: Voltage between L1 and L3 VOLTAGE L2-L3: Voltage between L2 and L3 VOLTAGE L1-L2: Voltage between L1 and L2 FREQUENCY: Frecuency in the line Li-Lj : Unbalance between phases PHASE CYCLE: Phase sequence From 1..3 independent relays, SPST NO. By default, we supply three relays. It is assigned to whichever of the measured magnitudes (voltage L1-L2, voltage L2-L3, voltage L1-L3, frequency, phases unbalance) to be transmitted through a 4-20 ma current loop, being able to coexist with the relays. Precision: 1% additional to the read value. This kind of output is optional. It is possible to establish different types of communication with a computer (see also last page): - By telephonic connector that incorporates standard device and CPBZ programming interface. - By a RS232 connection (optional). - By a RS2485 connection and SBAZ converter (optional). [024] 24 VAC 50/60Hz [110] 110..125 VAC 50/60Hz [230] 220..240 VAC 50/60Hz [400] 380..415 VAC 50/60Hz [440] 440 VAC 50/60Hz [903] 15..70 VAC/DC [904] 60..240 VAC/DC Ranges (VAC) -18% +18% 90,20 180,40 311,60 360,80 410 566 110..125 220..240 380..415 440 500 690 147,50 283,20 489,70 519,20 590 814 Three-phase voltage must be disconnected before or simultaneously than the supply voltage, never later. With an auxiliary supply voltage Communication (According options) Standard RS232 RS485 4-20 ma Code 0 Code 3 Code 8 Code 4 Connection diagram Using the own supply voltage Voltage in A1-A2 can be connected to whichever of the phases.

Phase sequence 2/5 Control of the voltage among phases Frequency control Unbalance among phases td = Delay on detection // tr = Delay on release State of the relay may vary according to the application. What is shown in the diagrams belongs to the set-up of the default user s programms 1 and 2.

18 28 38 L 3/5 1 2 3 Constructive and enviromental data Output relays Resistive AC load DC Inductive AC load DC Mechanical life Max. mech. operations Electric life at full load Contact material Operating voltage Voltage between contacts Voltage coil/contact Isolation resistance Indication Voltage phase-neutral Overvoltage category Shock voltage Pollution degree Protection Approx. weight Store temperature Operating temperature Humidity Housing Leds window Buttons, connector, clamp Connector s terminals Screws torque 15 25 35 6 A / 240 V 6 A / 24 V 3 A / 240 V 3 A / 24 V > 10 6 oper. 18.000 operations / hour 360 operations / hour AgSnO Alloy 240 VCA (85 ºC) 1000 VAC 4000 VAC > 100 M (500 VDC) 1 red led per relay 300 V I I I 4 kv 2 (EN61010) IP 20 280 g -30..+80ºC -20..+50ºC < 95% HR Cycoloy - Light grey Lexan - Transparente Technyl - Dark blue Brass 0,8 Nm Dessigned and manufactured under EEC normative. Directives referred: Electromagnetic compatibility: EMC 2004/108/EEC. Low voltage: LVD 2006/95/EEC. Hazardous substances: 2011/65/EEC Plastics: UL 91 V0 * In the worth of the cases Device parts Galvanic isolation Frequency Operating margins Consumption Start-up time Detection time Reset Options selection Screens selection Change of values Text edition Validation Indication Signaling of the supply voltage and status of the relays N [024]..[440] [903] [904] 4000 V 2500 V 50 Hz 60 Hz - ±18% 15..70 V 60..240 V 2,5 VA 3,5 W 3,1 W 120 ms 110 ms < 600 ms* < 200 ms* 45 ms 40 ms 135 ms 130 ms 1 net cycle and/or >70 ms * and/or -30% of the -30% of the nominal voltage nominal voltage Green led Contacts of the relays input LCD screen Connector communication (under) Control - Interface Number of relays Type of relay Communication Version Supply Ranges Dimensions Order code 9 - Q - U - With display. Default languages: Spanish English French Catalan (Other on request) Without display. Without communic. Without display. Communication RS232 / RS485. 0 - No relays 3-3 relays 0 - No relays A - SPST NO To compose the reference, select one option of each column. Example: 9 3A400 230 690 [ S ] 0 - No bus 4-4-20 ma 3 - RS232 8 - RS485 00..99 (By default, 3) (By default, A) (By default, 0) (By default, 00) [024] 24 VAC [110] 110..125 VAC [230] 220..240 VAC [400] 380..415 VAC [440] 440 VAC [903] 15..70 VAC/DC [904] 60..240 VAC/DC [110] 110..125 VAC [230] 220..240 VAC [400] 380..415 VAC [440] 440 VAC [500] 500 VAC [690] 690 VAC

User s manual How to programm Types of screens Interactive menus Changing values User s programms Display lighting Value added GENERAL CHARACTERISTICS OF THE DIGITAL CONTROL RELAYS For a wide knowledgment of the options offered by the digital control relays, the own User s Manual for each model must be read. Although an issue is given with every purchased device, a copy can be donwloaded in our web site (www.disibeint.com). The digital control relays can be indistinctly programmed either with the buttons placed in the front of the housing or with a personal computer. Please refer at the end of this page to learn more about the PC programming alternative. Status: They show the actual values of the magnitudes controlled by the relay. User: Where the user can write a customized text to help to the relay identification. Options: For accessing to the menus for the options selection. Informatives for values: They show the information of the different set parameters. Change of value: For modifying the values of the different values. Screens menus: Group of screens related under the same concept and that can contain whichever type of the screens previously described. For an ease programming, into the menus only the options that can be set are the ones visible. The rest of the options are not visible. This feature is interactive, ie., it is produced automatically according whether other functions are activated or not. The screens for changing the values contain the margins betwen such value can be adjusted. These margins can depend of other options and this is because different margins could be displayed according to other previous relations. Provided by factory two programs with options and pre-configured settings for quick start-up team. In most cases, these parameters should be tweaked to suit the characteristics of each installation. The user can create your own program and store it on your computer. The display remains backlihghted while it is accessed to the different screens. If any button is not pressed for longer than 30 seconds, the light turns off. In order to turn the light on, it is enough to press any button only once. - Four languages available in each relay - Graphic bar for the intuitive visualization of the displayed value - Historical control of the maximum values obtained by the relay - Screen s refresh selectable between 1 and 8 times per second - Possibility of locking the keyboard to avoid any undesired modification - Complementary timing functions 4/5 Alarm by frequency deviation SPECIFIC CHARACTERISTICS FOR THE MODEL This option affects to those relays with any voltage parameter activated. By default, this option is activated. Inhibits the activation of the relay in the state of alarm when the requency is deviated in ± 0,4 Hz during the detection process, and of ± 0,3 Hz during the releas process. For this kind of deviation in the frequency, the operating precision is reduced. More the frequency in the net is deviated, worse precision when reading its voltage. If this option is deactivated, you must remember that the reading precision of the voltage parameters decrease when the frequency gets deviations from its nominal values (50 Hz / 60 Hz). You must consider this reduction of precision when setting the values for detection and/or release. PC COMMUNICATION decom Communication and programming software for the digital control relays. It allows the interactivity between the different types of communication: through the interface, RS232 or RS485. It displays the complete data related to the relay, gruoped by concepts and easing the intuitive programming. It has control tools to do not exceed the operating margins of each model according to its range. It is provided with templates to facilitate the programming of each model. It allows to store the own settings. Windows XP minimum operative system (.NET Framework required).

5/5 OUTPUTS COMMUNICATIONS REMOTE PROGRAMMING FROM PC CURRENT LOOP 4-20 ma RS232 COMMUNICATION STANDARD MODE ACCESSORIES 1 2 Interface for remote programming from a PC. It allows the connection between whichever digital relay not provided with bus and a PC. Not required for devices provided with bus RS232, RS485 or with 4-20mA output. *Connector RJ 12 (6 pins) Seen from the cable entry * 88.88 ma 2 RxD 3 5 *RS-232 wire 3 5 3 5 *Serial adapter/usb SBAZ 12..30 VDC RS485 to RS232 signal converter for the remote programming or for the data capture and visualization from a PC. It allows the connection of up to 31 digital control relays provided with RS485 communication bus, to get an unique codified RS232 output. 2 RxD 3 3 *Connector RJ 10 (4 pins) 5 5 RS485 COMMUNICATION Seen from the cable entry # 1 # 2 # 31 SBAZ *RS-232 wire *Serial adapter/usb * Disibeint not supply cables or connectors. You can find these products in stores specializing in computer equipment. 5 3 2 2 3 5 Segle XX, 91 E08032-Barcelona Rev. 05/00 01/03/19 DISIBEINT reserves the right to modify this document without previous notice T: +34 934 330 370 F: +34 934 354 532 www.disibeint.com disibeint@disibeint.com