Visit to download the software Digalox Manager. Package contents: Panel meter Digalox DPM72, 5 jumpers, 1 mounting bracket

Similar documents
Process displays For current and voltage

DPM-3221 Digital DC Power Meter with data logging capability.

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

DPM Digital DC Power Meter with Data logging capability. User Manual

SOLARIMMERSION IV Advanced Installation Manual v1.9

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

TOXALERT MODEL AIR 2000

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Pen Drive USB Datalogger!

Mini Digital Multimeter

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Measuring and Monitoring Relays

User's Guide. Extech AM A AC Analog Clamp Meter

VAT series controller and transmitter. Manual

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

2 in 1 LAN Tester and Multimeter Model:

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Autoranging True RMS Multimeter User Manual

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Mini Digital Multimeter

DIGITAL PANEL THERMOMETER

Model. True RMSmA Clamp Meter. Instruction Manual

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

INDICATOR FOR PROCESS CONTROL. Love Controls. LCI108J-0x INSTRUCTION MANUAL. EDITION: January Valid for models with software version P-1

USER S MANUAL. Data Logger SOUND LEVEL METER.

Octostrip ORDERCODE 42220

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

Hardware Manual RM Display 2501 S01..S04

OZONE SWITCH Model OS-6. OS-6 Features

DRTS 33. The new generation of advanced three phase relay test set

Digital Sound Level Meter with USB Model:

Hardware Manual RM Display 2401

mark150s mark150/485s DDC controllers Summary

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

MIC-2 MKII, Multi-instrument DATA SHEET

CONTENTS 1. SAFETY INFORMATION SPECIFICATION PARTS & CONTROLS General Specification Electrical Specification...

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

ATS Automatic transfer switches Advanced version

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

DIGITAL PANEL METERS

MU110-6U. Analog output module 6 channel. User guide

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

MIC-2 Multi-instrument DATA SHEET

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

Mini Digital Multimeter Model MN15. User's Guide

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

ITP11(M04) Process indicator 4-20 ma. User guide

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

External level devices for conductive point level switch

User's Guide. Digital Multimeter. Model MN42

Signal Doublers. VariTrans A 20300

Instruction manual Wattmeter CLM1000 Standard

Model Number Structure

CLASS LEADING PRODUCTS PROVEN TO MEET THE MOST DEMANDING INDUSTRY SPECIFICATION, DELIVERED ON TIME, EVERY TIME

smartentry Wireless Video Doorphone User Manual

Operating instructions. Speed monitor D / / 2014

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

MODCELL 2050R Single Loop Controllers

Digital Indicator Solutions

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Series Watt DC Power Supplies

User Guide True RMS Multimeter Extech EX205T

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

Testing Instruments Manufactured by

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Quick Start Installation and User Manual

MULTICHANNEL DATA RECORDERS

Portable Data LOGGING SYSTEMS. for Professionals

Mini Digital Multimeter

Demonstration Case BENNING DB 1

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

German Cathodic Protection

Hoist Controller for Direct Voltage Hoist Instruction Manual

Digital Multifunction Meters. Digital Multifunction Meters

Monitoring Relays MRU, MRI, MRM

Bluetooth/USB Data Logger USER S MANUAL. Hantek 365A/B/C/D/E/F V

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

USB-500/600 Series Low-Cost Data Loggers and Accessories

Transcription:

Digalox DPM72MPN Instruction manual (Rev201809) Visit www.digalox.com to download the software Digalox Manager. Package contents: Panel meter Digalox DPM72, 5 jumpers, 1 mounting bracket 1. Intended Use Indoor use non condensing, non corrosive. Panel mounting. Failure to comply with these instructions will void all guarantee and warranty. In operation, supply the device preferably via screw terminals with 10 to 24 V AC/DC. If the device is supplied via USB in operation, USB supply voltage must be at least 5 V. 2. Safety instructions Note: The measurement inputs of the device can carry lifethreatening voltages! When working on the device hazardous voltages must not be connected to the device! The device must not be used as the only protective device or protective shutdown. Read instruction manual carefully before operating the device! The device is not intended to protect persons or facilities against harm. Specific devices must be used to guarantee safety (protection relays, cutoff switches, etc.). When connecting switches to the terminals, only switches must be used whose isolation voltage is at least twice the maximum occurring measurement voltage. For example, when measuring 250 V AC switches must be isolated for at least 500 V. Do not open the housing! Do not use the instrument in the presence of explosive or flammable substances! All cables carrying hazardous voltages must be secured with external separators. 1

3. Description The multi display with RGB backlight is able to display up to 4 parameters simultaneously. Thresholds can be associated with individual warning backlight colours. The unit can be switched between measurement modes via an external switch. Minimum and maximum values for each parameter are recorded and can be displayed optionally using an external switch. Measured values of one parameter are recorded over a time span of three minutes up to 14 days. The time base as well as the display of the measuring history can be activated by an external switch. The measured values remain stored as long as the device is supplied with voltage. The following parameters can be adjusted using the USB software: scale endpoint, scale caption, display style (pointer, tachometer, bar graph, and more), splash image, backlight colour, thresholds for alarm output, threshold warning colour (light, blink), hysteresis, and more. Recorded measurement values can be read and a continuous transmission of up to four measuring values can be enabled. Using the software, values can be viewed and exported as CSV file. Front 1 Unit or free text 2 Threshold values 3 Upper scale caption 4 Graphical measurement display 5 Digital measurement value 6 Lower scale caption Back 1 2 optocoupler switch outputs 2 DIP switch for setting measurement mode and upper scale caption 3 Supply voltage input 4 Jumpers for configuration/connection external switch for activating/switching measurement mode, graphical historic data display, min/max display, autoscaling 5 USB interface for alternative power supply and software communication interface 6 Measurement inputs 2

4. Electrical Connections Supply Voltage direct 10 24 V Fuse 250 ma Digalox Supply 500 V Current via external shunt Current via external shunt, voltage direct 200 mv Shunt Load 200 mv Shunt Load 500 V Current via external shunt on high side, 50 V max! Current via external shunt on high side, voltage direct, 50 V max! 200 mv 200 mv Load Shunt 50 V! Load Shunt 50 V! Warning: The device may only be operated in one of the connection options shown above! Current measurement on the high side (between plus and load) is recommended only for voltages up to 50 V! In this case the entire device is on high potential. Particularly to be considered when connecting switches to 6. When measuring current, an external shunt must be connected to U1! 3

5. Configuration The device can be configured via DIP switches and jumpers manually or with the corresponding software Digalox Manager via USB interface. When configuring via DIP switches and jumpers the basic settings can be made computerindependent. The configuration with the software Digalox Manager allows full functionality. Scaling When setting the scaling via DIP switch to represent the correct measurement value (e.g. 60 mv DC for shunt) the upper scale caption corresponds to the primary value of the shunt. Example: upper scale caption = 250 = primary value shunt Configuration via USB interface with software Digalox Manager For configuration with software set DIP switch 10 to OFF position. Please note that the measurement mode selected in "Digalox Manager" is displayed only until the power supply of the DPM72 is interrupted. In further operation, the device always shows the measurement mode, which is selected by the jumpers J4 or the DIP switches 1112 respectively! (see table "Measurement mode"). Configuration via DIP switches and jumpers if only one measurement mode is required (Manual mode) 1. Set DIP switch 10 to position. 2. Set measurement mode with jumpers at J4 according to table Measurement mode, column Manual mode. 3. Set upper scale caption for the first measurement mode with DIP switches 19 (see Configuration of the upper scale caption ). 4. Connect supply voltage. 4

Configuration via DIP switches and jumpers if it is required to switch between multiple measurement modes via an external switch (Save mode) The required measurement modes are configured and saved sequentially. 1. Connect supply voltage. 2. Set DIPswitch 10, 11 and 12 to OFF position. 3. Set the measurement mode with jumpers at J4 according to table Measurement mode, column Save mode. 4. Set DIP switch 10 to position. 5. Set upper scale caption for the first measurement mode with DIP switches 19 (see Configuration of the upper scale caption ). 6. Set time base for graphical historic data display (optional, see Other settings ). 7. Set DIP switch 10 to OFF position. 8. Saved appears on the display. The configuration of the first measurement mode is now completed. 9. When using multiple measurement modes repeat steps 28 until all required measurement modes are configured. The time base does not need to be set again, as it is used for all measurement modes. 10. In operation the measurement modes can be changed with a switch at J4 according to table Measurement mode, column Save mode. Configuration of the upper scale caption The upper scale caption is binary coded using DIP switches 19. Possible values are 1 to 500. Switch 1 corresponds to 256, switch 2 corresponds to 128, switch 3 corresponds to 64, etc., switch 9 corresponds to 1. For configuration, proceed as follows: 1. Connect supply voltage. 2. Set DIP switches 19 to OFF position. 3. Set DIP switch 10 to Position. 4. Start with 1st switch. 5. Set switch to position. 6. If the displayed value is greater than the desired value, set the switch back to OFF position. 7. If the displayed value is less than the desired value, leave the switch in position and move on to the next switch. 8. Repeat steps 5 to 7 until the desired value is displayed. 5

Table common switch combinations Value 10 20 25 Combination (DIP switch 19) Value 50 100 150 Combination (DIP switch 19) Value 200 250 500 Combination (DIP switch 19) Table measurement mode Measurement mode V DC direct A DC scaled P DC scaled V AC direct A AC scaled (with shunt) P AC scaled (with shunt) AC Frequency Display Scale Manual mode Save mode Volt DC Ampere DC Watt DC Volt AC Ampere CT Watt CT Frequency AC Upper scale caption Configure via USB Upper scale caption Configure via USB Remark: When using a multi display style, AC and DC measurement cannot be done simultaneously. The first measurement mode used defines the type of measurement. 6

6. Other settings The following functions can be activated independently by shortcircuiting connectors J3 by jumper or switch during operation: : Graphical historic data display To activate the graphical historic data display connector is shorted. The unit displays the stored values within the set time base as a graphical trend. The time base can be set to days (7, 14), hours (6, 12, 24, 48, 72) or minutes (3, 15, 30, 60). The time base can be changed by alternately opening and closing (interval < 2 sec). When first opening and closing the current time base is displayed. For each subsequent opening and closing the time base changes to the next setting. In order to save the setting permanently, DIP switch 10 must be switched from to OFF position. J2: MinMaxdisplay To activate the MinMax display connector J2 is shorted. The display shows the maximum and minimum values recorded since the last reset. The values can be reset by opening and closing connection J2 shortly (interval < 2 sec). The display shows "Minmax reset". J3: Autoscaling To activate autoscaling J3 connector is shorted. The device automatically changes the upper scale caption depending on the current measuring value between 10, 100 and the set upper scale caption. 7

7. Mounting Carefully insert the instrument into the panel cutout. Insert the mounting bracket from the back and push towards the panel until the instrument sits tight. Make sure the mounting bracket is snapped into the side of the housing. To ensure IP65 protection (dust and water jet) when mounting in a front panel, use optional gasket (separately available). 8. Specifications DPM72MPN Supply 10 24 V AC/DC or via USB (min. 5 V) galvanically isolated Display LCD graphic display 192 160 pixels Voltage measurement: Measuring range ±500 V AC/DC Accuracy ±1 % true RMS Internal resistance 2.6 MΩ Ampere measurement via shunt: Measuring range 50/60 mv AC/DC Accuracy ±1 % true RMS Internal resistance 20 kω Frequency measurement: Measuring range 10 500 Hz Accuracy ±0.1 Hz Recording of measurement 3 min to 14 days Alarm outputs 2 optocoupler outputs 30 V DC, 50 ma Operating temperature 0 C to 50 C Storage temperature 20 C to 70 C Front panel 72 mm 72 mm Panel cutout 68 mm 68 mm Protection front IP65 from the front 9. Cleaning Observe the safety instructions before cleaning the instrument. Clean the instrument with a dry lintfree soft cloth. Do not use solvents. 10. Contact Information TDE Instruments GmbH, Gewerbestraße 8, D71144 Steinenbronn phone: 49 715720801 EMail: info@tdeinstruments.de Internet: www.tdeinstruments.de, www.digalox.com 8