Similar documents
Cary Fiber Optic Probes

XSLIDE. XSlide Positioning System. Manual and Motorized. Compact Positioning Stage. Long life, precise movement, greater value

FTIR-7600 FT-IR Spectrometer Accessories Price List 2011

Talboys Standard Analog Dry Block Heaters

MicroLab Component Holders

ecovis Krypton Light Source Installation and Operation Manual Document Number

Versatile laser Raman Spectrometer. RMP-500 series

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

Reaction Blocks for Circular-top Hot Plate/Stirrers. New sizes Easy to use Complete systems Economical and efficient

Dry Block Heaters. Quality Selection Value

Educational Microfluidic Starter Kit

Optical Fiber Assemblies

Thermo Scientific GENESYS UV-Vis Spectrophotometer Accessories. Make the most of every sample

Reaction Blocks for Circular-top Hot Plate/Stirrers. sizes Easy to use

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A MICHELSON INTERFEROMETER. TECHSPEC Optical Cage System

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A FLUORESCENCE MICROSCOPE. TECHSPEC Optical Cage System

PELCO SEM Specimen Holders

Innovative Technologies.

Protocol Procedures for OCA15EC

نﺎﻤﻟ آ ﻲﻧﺎﭙﻤﻛ يرﺎﺼﺤﻧا هﺪﻨﻳﺎﻤﻧ

Reaction Blocks for Circular-top Hot Plate/Stirrers

STEP-BY-STEP INSTRUCTIONS FOR BUILDING AN AUTOCOLLIMATOR. TECHSPEC Optical Cage System

ASI Photoport TIRF Injector Instruction Manual

SOLUTIONS RECERTIFICATION CALIBRATION AND UV/VIS REFERENCE MATERIALS. Photometric and Wavelength Accuracy Reference Material Set

Prizmatix. Optical Specifications. Mic-LED-635 spectrum. BLCC-02 Benchtop LED Current Controller Specifications

Laser Diode Collimators Type 48TE, 48-0, and 44TE, universal modular system for self-assembly

LASERS FOR ANALYTICAL INSTRUMENTATION

LaserLyte-Flex Red & Green Alignment System

More Precision. wiresensor // Draw-wire displacement sensors

UNISLIDE. UniSlide Positioning System. Manual. Wide Array Of Linear Motion Devices. Rugged, simple, effective, world-wide reknown, low cost

Laserlyte Alignment System

Spectro-115E TM and Spectro-115U TM Spectroelectrochemical System. Operator s Manual

IS-DM220/IR/HB IS-DM220

SeBa Digital Imaging Systems

A Global Laser Brand. Versatile Module

6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory

FS01. Functions. High Accuracy Fibreoptic Sensors. From ultra-high precision to ultra-high power: A single unit covers every application

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

LASERS FOR ANALYTICAL INSTRUMENTATION

MicroLab Posts, Bases, and Rails

Bore Alignment. Extruder Alignment. Application Notes

User manual MB-600 Matte box system Version 1.0.0

RAMM Microscope Configuration Guide

HEIGHT GAUGES. Moore & Wright Vernier Height Gauge 190 Series. Digital Mini Height Gauge 192 Series. Partners in Precision

SlicePlatform Fixed Platform System


18W Triple 35W T4.5 G8.5 Halogen T10 100W

Luminescence Sensors. The bright idea for fluorescent material

Ravenna TM. Fixture Options: Ordered Separately from Fixture See page 2. Mounting Options: Ordered Separately from Fixture See pages 3-5

DXR SmartRaman Spectrometer

Belleville Spring Washer Series

IKA Mixing Orbital shakers

Familiar, and yet very surprising

EDM LASER STEM Drilling

TV & Office Solutions by equip solutions with a high value of benefit

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling

TV Brackets by equip The perfect solution to securely mount your TV

Adjust-O Magnet Squares

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

Model ISOXSHLD ISOCS Shield Systems

More Precision. eddyncdt // Eddy current sensors for displacement and position

A10 Micro Speaker Clamping A10. Micro Speaker Clamping FEATURES

XL-80 spares list. Application note. Overview

ML17 Series Tru-Vue TM Sensors

CLIMB2 DUAL MONITOR SIT/STAND WORKSTATION

The Anfatec Level AFM a short description. Atomic Force Microscopy - approved devices for affordable prices

Clinical Support Products. Supporting your clinical care in so many ways.

phoenix Upgrade Packages for SLM Model 4800/48000/8000/8100 Spectrofluorometers

Photoelectric Sensors

Translation Stages Triple-Divide Series

COMPACT PRECISION LINEAR MOTORIZED ACTUATORS LSMA Series LSMA-173

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

Preconfigured Optical Setups for the General Purpose Optical Bench for Frontier FT-IR Spectrometers. FT-IR Spectroscopy.

SPECTRUM. The world s first fully automated Raman AFM. AFM - confocal Raman - SNOM - TERS AFM KPFM. Raman. AFM-Raman characterization of PS-PVAC

YOUR STABLE PARTNER FOR MANUFACTURING. MARSTAND

Lab 4: Trajectory Following 1

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

Multisensor Coordinate Measuring Machines ZEISS O-INSPECT

Nikon Focus Drive Manual

Microscopic Imaging Research Station (MIRS) Assembly Guide. Version 1.0.0

Measuring object. Fig. 1: Optical scheme of focus-touching (concentricity measurement with measuring ball)

More Precision. indusensor // Linear inductive displacement sensors

Magnetic probe holders are fully adjustable for more DUT heights and probe styles

glass optical fibers

Linkam Scientific Instruments

Operation Manual. Autocollimator Test Wedge for quick testing of Electronic Autocollimators

Positioning Systems Linear Module

ProScan. High Performance Motorized Stage Systems

User Manual. Trinocular Stereo Microscope

OCEAN OPTICS Chem 2000 Spectrophotometer

Clean packaging Class M3.5 Standard packaging Class M5.5. The U type is recommended when changing tubing sizes. Packaging

Depth analysis for laminated film by confocal Raman mapping

ABM's High Resolution Mask Aligner Features:

More Precision. eddyncdt // Eddy current sensors for displacement and position

Contents Contents 2 Preface 3 Introduction 4 Components 5 Operation 6 Timer 7 Lamp Replacement 9 Specification 10 Ordering Information 11 2

In North America, call

TubeMount system. Section 11 (pp.53-59) Breadboards and bases. Section 12 (pp.60-62) Stages and rod system. Section 13 (pp.63-70)

INSTALLATION INSTRUCTIONS

Leapers, Inc. Proudly Presents UTG OPTICS DOT SIGHTS TOTAL SOLUTION TO YOUR NEEDS -COMMITMENT TO BEST QUALITY, BEST VALUE AND BEST SERVICE-

Y, XY AND XYZ MOTION. Section 09. Introduction to Y, XY and XYZ Stages 114. Y Shifts 116. XY MultiBase Manipulators 118

Transcription:

Raman Sample Holders Ocean Optics offers several sample holders for Raman analysis of liquids and solids, including a multipurpose holder that can be configured for fluorescence and other measurements. The holders accommodate Raman probes from 9.5 mm-12.7 mm diameter, and 1 cm pathlength cuvettes and vials of various dimensions. The RM-SERS-SHS holder is ideal for surface enhanced Raman spectroscopy (SERS) substrates, which comprise nanoparticle chemistries on slides. The holder accommodates standard glass SERS slides and connects to a Raman probe. The RM-SERS-SHS provides accurate positioning for the Raman measurement, avoids the influence of ambient light, and improves the accuracy of the Raman measurement. The RM-LQ-SHS holder accommodates vials and cuvettes. It has a magnetic cover, making it easy to load and unload samples, block ambient light, and improve the accuracy of Raman measurements. Also available is the OOA-RAMAN-SH sample holder for vial and cuvette measurements, which has a positioning screw to optimize the focus of the laser onto the sample. The multipurpose OOA-HOLDER-RFA is a modular fixture adjustable for Raman, fluorescence, absorbance and reflection measurements. The holder is compact, lightweight and easy to load and unload. Its design protects against damage that can be caused by contact between the probe and cuvettes.

Specifications Engineering RM-SERS-SHS RM-LQ-SHS OOA-HOLDER-RFA OOA-RAMAN-SH Specifications Techniques Raman Raman Raman, fluorescence, Raman supported: absorbance Base material: Aluminum Aluminum Aluminum Aluminum Probe diameter 9.5 mm 9.5 mm Raman probe: 9.5 or 9.5 mm 12.7 mm; Reflection probe: 6.35mm Cuvette Type: Standard microscope 1 cm pathlength 1 cm pathlength square 1 cm pathlength square slide 75 x 25 mm or SERS substrates square or 15 mm OD vials Translation stage: No No Yes Yes Mirror/cuvette plugs: No Yes Yes No Dimensions (LWH, 75 X 75 X 35 115 X 80 X 70 110 X 70 X 130 mm 80 X 47 X 81 mm mm): mm mm (155 X 70 X 162 mm, optional) Weight: 186 g 629 g 1279 g 630 g Temperature range: -20 C to 80 C -20 C to 80 C -20 C to 80 C -20 C to 80 C Probe type RPB Raman probes RPB Raman probes RPB Raman probes RPB Raman probes 1. RM-SERS-SHS

1.1 Requirement Specification The special holder for the SERS substrate from Ocean Optics is suitable for the modular Raman probe, which can provide accurate positioning for the measurement, as well as isolating from the impact of ambient light to improve the measurement accuracy. 1.2 Design Specification 1.2.1 Features of the RM-SERS-SHS Holder Aluminum + stainless steel, suitable for modular Raman probe. OOI glass substrate SERS. Provide accurate positioning for measurement, avoid influence of ambient light, and improve the accuracy of measurement. It can be connected to probe directly. The base can be disassembled, small size. Reasonable clamping design without damaging the slides. The base can be fixed on the optical platform. 1.3 Instructions 1) Insert the SERS slide to the SERS holder. 2) Insert the probe to the SERS holder. 3) Lock the probe. 4) Measure the sample accordingly. If needed, adjust the height position of the probe to focus the laser on the sample.

2. RM-LQ-SHS 2.1 Requirement Specification For Raman applications, the distance between Sample and Probe tips will determine the Raman signal intensity. The sample holder allows the user to adjust the distance between Sample and Probe tips accurately and conveniently. This liquid sample holder is suitable for the modular Raman probe. It can isolate the impact of ambient light to improve the measurement accuracy. 2.2 Design Specification 2.2.1 Features of the RM-LQ-SHS Sample Holder It can adjust the distance between probe and sample accurately. The height of the sample holder can be adjusted to get the best signal. It is compact and lightweight, easy loading and unloading. No additional adjustment, automatically adapt to different sizes of sample vials, suitable for modular Raman probe. It can reduce the influence of ambient light and improve the accuracy of measurement. It can be used for bottle-side measurement. Bottom base can be disassembled, it also can be fixed in optics platform. Secured with a nut, which will not fall off.

2.2.2 The structure of the RM-LQ-SHS Sample Holder 2.3 Instructions 1) Open the top cover. 2) Pull out the clamp, insert the liquid samples or cuvette vials inside the box. 3) Put the top cover back. 4) Insert the probe to the liquid sample holder. 5) Lock the probe with the screw. 6) Measure the sample.

3. OOA-HOLDER-RFA 3.1 Requirement Specification OOA-HOLDER-RFA is a versatile holder and very useful for various applications using Ocean Optics fiber coupled spectrometers. It can be used for Raman probe holder, fluorescence holder, absorbance holder and reflection holder. 3.2 Design Specification 3.2.1 Features of OOA-HOLDER-RFA An XZ axis mobile stage for adjusting the focus position of the Raman probe The range in the x-direction is 10 mm and in the z-direction is 12.5 mm. Supports several different probe sizes (e.g. 6.35 mm, 9.5 mm, and 12.7 mm diameter probes). Supports 10 and 1 mm cuvettes. Mirror plugs (2pcs; 15 mm X 5.7 mm X 45 mm) and cuvette plug (2pcs; 15 mm X 5.7 mm X 45 mm) for 1mm light path cuvette for absorbance and reflection measurement. 90 angle cross design support for fluorescence measurement. Mirrors: 2pcs, Coating: Al+MgF 2 (coating: Al, optional)

3.2.2 The structure of OOA-HOLDER-RFA 3.3 Instructions 1) Open the top cover. 2) Insert cuvette inside the box. 3) Put the top cover back. 4) Insert the appropriate probe and fiber ends to the sample holder. 5) Measure the sample.

4. OOA-RAMAN-SH 4.1 Requirement Specification For Raman measurements, the distance between the sample and probe will determine the Raman signal intensity. The sample holder allows the user to adjust the distance between the sample and probe accurately and conveniently. This vial and cuvette sample holder is suitable for the modular Raman probe. It can eliminate ambient light to improve the measurement accuracy. 4.2 Design Specification 4.2.1 Features of the OOA-RAMAN-SH Sample Holder OOA-RAMAN-SH works with a variety of sample sizes. The compatible cuvette dimensions are 13 x 13 mm square, and the compatible dimensions for vials are 12.4 mm, 15 mm, and 23 mm in diameter. The hole at the side of the holder is to hold the Raman probe. The through-holes of different shapes and sizes at the top are designed for different cuvettes or vials. There is a shallower counter bore on the top to connect with the cover. 4-M3x6mm screws to fix the sample holder to the translation stage. A M3x9mm screw with hand wheel for fixed the sample holder cover: the sample holder cover has a slot on one side is used to fix the sample holder cover, screw and it should not move or fall off during the movement of the micro translation stage. Sample holder cover is used to block ambient light during the experiments. The hole at the side of Raman sample holder is used to stabilize and protect the probe. It

omits ambient light, where a M3x3 screw is used to fix the probe to the Raman sample holder. User can adjust the one-dimensional translation stage. It can adjust the location of the focus of excitation light to meet the demand of detecting. The micro-translation can move a total distance of 8 mm (4 mm in each direction). The holder is compatible with the OOI Raman Probe RPB. 4.2.2 The structure of the OOA-RAMAN-SH Sample Holder 4.3 Instructions 1. Open the top cover. 2. Insert the appropriate sample chamber to accommodate your vial or cuvette. 3. Insert sample vial or cuvette. 4. Put the top cover back on, and line up the slot with the hand screw. Fasten the cover down with the hand screw on the side. 5. Insert the Raman probe in the hole on the side of the holder. Carefully, push it in as far as it will allow. 6. Lock the probe in place with the M3x3 screw. 7. Measure the sample. Adjust the one-dimensional stage to change the location of the focused laser beam for the most intense Raman signal.