Spatial resolution study of a neutron imaging system using the slanted edge method.

Similar documents
18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

Application of MCNP Code in Shielding Design for Radioactive Sources

Simulation of Internal Backscatter Effects on MTF and SNR of Pixelated Photon-counting Detectors

Control systems for spallation target in China ADS systems

Current Status of Neutron Imaging at PNL. 1 September 2017 Michael Taylor

DAMAGE INSPECTION AND EVALUATION IN THE WHOLE VIEW FIELD USING LASER

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada

Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

Muon imaging for innovative tomography of large volume and heterogeneous cemented waste packages

SUPPLEMENTARY INFORMATION

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

Quality control phantoms and protocol for a tomography system

Supporting Information for Critical Factors of the 3D Microstructural Formation. in Hybrid Conductive Adhesive Materials by X-ray Nano-tomography

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Easy integration into complex experimental setup

QUANTITATIVE PHASE IMAGING OF BIOLOGICAL CELLS USING OFF-AXIS METHOD OF WIDE FIELD DIGITAL INTERFERENCE MICROSCOPY (WFDIM)

Scanner MTF Evaluation using edge gradient analysis

Abstract: Introduction:

Specifications Summary 3. Active pixels 2048 x Pixel size (W x H) 13.5 x 13.5 µm. Active area pixel well depth (typical) 100,000 e -

Measurement of droplets temperature by using a global rainbow technique with a pulse laser

( ) = First Bessel function, x = π Dθ

CT Systems and their standards

The Pennsylvania State University. The Graduate School. College of Engineering DEVELOPMENT OF A NEUTRON COMPUTED TOMOGRAPHY SYSTEM

diffraction patterns obtained with convergent electron beams yield more information than patterns obtained with parallel electron beams:

COMPUTER MODELING METHODOLOGY FOR LASER CUTTING PROCESS SUPPORTED WITH EXPERIMENT ON STAINLESS STEEL PLATE

3D Computed Tomography (CT) Its Application to Aerospace Industry

7.3 Refractive Index Profiling of Fibers and Fusion Splices

The digital EVOlution in cassette size format

TracePro Stray Light Simulation

Fast Neutron Resonance Radiography in a Pulsed Neutron Beam. V. Dangendorf,

Neurophysical Model by Barten and Its Development

2. Equipment, specimens and inspection procedures

Comparison between 3D Digital and Optical Microscopes for the Surface Measurement using Image Processing Techniques

Laser Speckle Photometry for Stress Measuring at Industrial Components

Fast data acquisition measurement system for plasma diagnostics using GEM detectors

Versatile laser Raman Spectrometer. RMP-500 series

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE

Image Analysis. Edge Detection

IMPROVEMENT OF SCREEN MONITOR WITH SUPPRESSION OF COHERENT-OTR FOR SACLA

Supplemental information. Appendix to Wavelength-scale light concentrator made by direct 3D laser writing of polymer metamaterials

Deeply Virtual Compton Scattering at Jefferson Lab

Refined Measurement of Digital Image Texture Loss Peter D. Burns Burns Digital Imaging Fairport, NY USA

Detector systems for light microscopy

OPTICAL TOOL FOR IMPACT DAMAGE CHARACTERIZATION ON AIRCRAFT FUSELAGE

Simulation of Radiographic Testing for POD Assessment

Introduction to. 3D Scanning Confocal Microscope with Spectrometer

Neutron Capture Measurements and Resonance Parameters of Gadolinium

Fast Reconstruction of CFRP X-ray Images based on a Neural Network Filtered Backprojection Approach

Biological Image Information I: A Description of the Modalities

Scattering/Wave Terminology A few terms show up throughout the discussion of electron microscopy:

Improvement of Infrared Imaging Video Bolometer Systems in LHD )

Saliency Detection for Videos Using 3D FFT Local Spectra

Towards 0.1 mm spatial resolution

Radiation Center Strategic Plan Mission, Vision, Goals and Strategies for Activities and Operations

CHEM-E5225 :Electron Microscopy Imaging I

DETERMINATION OF THE ORIENTATION OF AN EPITAXIAL THIN FILM BY A NEW COMPUTER PROGRAM CrystalGuide

Application of Photopolymer Holographic Gratings

BEAVRS benchmark calculations with Serpent-ARES code sequence

Frequency-based method to optimize the number of projections for industrial computed tomography

RDHA701FP10A8QK. Neutron and Total Ionizing Dose Test Report. April 2009

TEM Imaging and Dynamical Scattering

Determination of the aperture of the LHCb VELO RF foil

arxiv:physics/ v1 [physics.ins-det] 18 Dec 1998

Development and Characterization of a Flat-panel Detector-based Microtomography System

THIN WALL LIQUID FILM THICKNESS MEASUREMENT: A VIDEO OPTICAL TECHNIQUE.

Miniaturized Camera Systems for Microfactories

Scatter Correction Methods in Dimensional CT

X-ray simulation and applications

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Continuation Format Page

NIRvana: 640. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

Identification of Shielding Material Configurations Using NMIS Imaging

APPLICATION OF Ni/C-GÖBEL MIRRORS AS PARALLEL BEAM X-RAY OPTICS FOR Cu Ka AND Mo Ka RADIATION

The Pennsylvania State University. The Graduate School. Department of Mechanical and Nuclear Engineering

3D Detector Simulation with Synopsys TCAD

Deliverable D10.2. WP10 JRA04 INDESYS Innovative solutions for nuclear physics detectors

Spectroscopic Ellipsometer --- J. A. Woollam alpha-se

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

Search for hidden high-z materials inside containers with the Muon Portal Project

Draft SPOTS Standard Part III (7)

IMPROVEMENTS TO MONK & MCBEND ENABLING COUPLING & THE USE OF MONK CALCULATED ISOTOPIC COMPOSITIONS IN SHIELDING & CRITICALITY

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection

Research and Design of Laser Accurate Displacement Measurement System Xiaogang Wang 1, a, Yuewei Bai 1,b and Kai Liu 1,c

Defect Repair for EUVL Mask Blanks

Gamma spectroscopic measurements using the PID350 pixelated CdTe radiation detector

Noncontact measurements of optical inhomogeneity stratified media parameters by location of laser radiation caustics

Performance Evaluation of 3-Axis Scanner Automated For Industrial Gamma- Ray Computed Tomography

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Mathematical methods and simulations tools useful in medical radiation physics

Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms

Project GAMMA: Adaptive Methods for Medical Applications

TOLERANCE ANALYSIS OF THIN-WALL CFRP STRUCTURAL ELEMENTS USING TOMOGRAPHIC IMAGING

THREE-DIMENSIONAL MAPPING OF FATIGUE CRACK POSITION VIA A NOVEL X-RAY PHASE CONTRAST APPROACH

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology

Pixel Crosstalk and Correlation with Modulation Transfer Function of CMOS Image Sensor

Variation of Refractive Index inside an Aerogel Block

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

Transcription:

Spatial resolution study of a neutron imaging system using the slanted edge method. L. Boukerdja (1), M. Guerrache (2), O. Dendene (1), A. Ali (1) 1) Centre de Recherche Nucléaire de Birine, B.P. 180, Ain Oussera, 17200, Djelfa, Algérie 2) Université Ferhat Abbas Sétif1, Algérie E-mail: boukerdjal@yahoo.fr I- INTRODUCTION Neutron imaging is a very powerful technique for nondestructive testing, it allows obtaining image of the internal structure of objects in 2D or 3D mode. During the last years, attempts have been made to implement and to develop a neutron tomography system at the Nuclear Research Center of Birine. At this end a new Peltier-Cooled CCD camera (16 bit) has been installed instead the old CCD camera (8 bit) and a turntable has been designed. The aim of this work is the determination of the spatial resolution of the new imaging detector by calculating the modulation transfer function ( MTF) using slated edge method. At this end a Matlab program has been written for MTF calculation. II. MTF Calculation Method The characterization of an imaging system s response in terms of spatial resolution is a very important task that allows the determination of the system limits and capability to visualize very small details. The spatial resolution is one of the most important characteristics of any imaging system, the Modulation Transfer Function (MTF) is a common metric used to quantify it. A MTF value of 1 indicates that the full amplitude is transferred by the imaging system, while a MTF value of 0 indicates that no signal at all is transferred IV- Results The analysis of this MTF curve (Fig.4) allows the determination of the spatial resolution of the imaging system. For MTF measurement we used the slanted edge method which consist of imaging a thin and sharp slanted-edge onto the detector. The edge target must be made from a strong absorbing material such as Gadolinium. The main steps for MTF measurement are represented in Fig.1.. Differentiation FFT Fig. 4. MTF obtained for the imaging system studied using Matlab The spatiale resolution is calculated from the spatial frequency corresponding to the value 0,5 of the MTF (MTF50) by the relation : (1) III- Experimental Procedure For MTF measurement, we have proceeded of imaging a thin Gadolinium foil (25µm thick), slightly tilted, onto the detector (Fig.2). Gadolinium is highly neutron absorbing which allows the production of suitable image with necessary contrast between dark and light parts (edge). According to this relation the spatial resolution limit calculated at MTF50 is about 0,202 mm (202 µm). In addition, the MTF was calculated by Quick MTF software and the result obtained is presented in Fig.5. Cooled CCD Camera (16bit) LiFZnS scintillator Gd foil Neutrons beam LiFZnS scintillator Fig.2: Irradiation setup The detector was exposed arround the neutron imaging facility of Es-Salam reactor to a thermal neutron flux of 10 6 n/cm².s. IV- Results The neutron image obtained of the examined edge target is shown in Fig. 3. Not covered region (Background) Gadolinium covered region Fig. 3: Targed neutron image Fig. 5. MTF obtained for the imaging system using Quick MTF. From this curve the MTF50 is about 2.5 C/mm and so the spatiale resolution limit calculated by the relation (1) is 0,200 mm which is in good agreement with the value obtainded by Matlab code. V- CONCLUSION The main objective of this study was the characterization in terms of spatial resolution the new imaging system used in our neutron tomography facility. In accordance with MTF procedure the spatial resolution measured using the Matlab program is of the order of 202 µm. This result allowed us to know the limits of our imaging system and its capacities for tomographic examinations and what applications can be successfully carried out. Finally, we can say that the slanted-edge method is a suitable technique for efficient MTF measurement, allowing the determination of spatial resolution of the neutron imaging system being studied According to MTF procedure and using the developed Matlab program the spatial resolution was determined for a value of 0.5 of MTF (Nyquist frequency) that provides the limit between an under-sampled and poor displayed image (very low frequencies) and an optimally sampled and well-displayed image (mediumand high frequencies).