CoPilot EXT. Electro Industries/GaugeTech. Installation & Operation Manual Revision PDA Based Software

Similar documents
Nexus 1262 / Electro Industries/GaugeTech. Installation & Operation Manual Version High Performance Socket and Switchboard Meters

Electronic Submeter with Advanced WiFi Ethernet Capability

Nexus 1262 /1272. Electro Industries/GaugeTech. Installation & Operation Manual Revision High Performance Socket Meter

NEW MODERNSTE TECHNOLOGIE. Elektronische Messgeräte mit hoher WiFi Ethernet Leistungsfähigkeit. Führende Technologie in der Industrie

NEW Industry Leading Technology. Includes Modbus and DNP 3.0 A G G R E S S I V E T E C H N O L O G Y. High End Meter Performance

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control

Futura+ Communicator 2.0 Professional Edition

SH RK 100S SH RK 200S

AiREPORTS 2.0. Electro Industries/GaugeTech. for use with Nexus Communicator. User Manual Revision 2.02

Electronic Submeter with WIFI Ethernet Capability and Datalogging. Installation & Operation Manual Revision 1.01

Industry Leading Performance From Simple to Sophisticated Highly Accurate Metering Technology

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

Nexus 1250 /1252 High Performance SCADA Monitor

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

Nexus Cyber Secure Energy Panel Meter with Advanced Power Quality & Multiport Communication. Advanced Power Quality Analysis

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

FA-2448 SIX POSITION Filter Wheel

UW Purchase Specification Section

B: Modbus Map and Retrieving Logs

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

User's Guide. Temperature / Humidity Datalogger. Model 42270

EXT-DVI-3600HD User Manual

Doc# E V.1.02 QS - 1

Bluetooth USB User Guide. Revision A July 12, 2006 Part Number GC

VGA RS-232 Extender USER MANUAL.

SMD Series Integrated Stepper Driver and Motor Revision 1.3

RGM180 Display Series

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

MODBUS MANUAL For the AccUView UV Transmission Monitor

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

Plus-X 300. Installation and Operation Manual

Integrated Stepper Drive & Motor

PCMCIA Flash Card User Guide

USER MANUAL MODEL 536S Token Ring (STP) Surge Protector. SALES OFFICE (301) TECHNICAL SUPPORT (301)

The HPV Explorer is a serial communication program used to work with the HPV 600/900 s parameters via a computer s serial port

REMOTE FRONT PANEL EMULATION

SmartLog X 3 TEAM Basic Software Installation and Operation Instructions

FES BMS CONTROL MANUAL

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Data Broadcast Switch

PowerMouse Version 1.05 March PowerMouse. The FlarmMouse successor. Version 1.05

USER MANUAL MODEL 515 DB-15 Surge Protector

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

JTAGjet. series SIGNUM SYSTEMS CORPORATION. USB 2.0 Driver for JTAGjet and ADM51. Installation Instructions

WARRANTY & LIMITATION OF LIABILITY

GageWay SM. Copyright MicroRidge Systems, Inc.

PDA-CAN Bridge. Version 1.0. LXNAV d.o.o. Kidričeva 24, 3000 Celje, Slovenia tel fax

User's Guide. Datalogging Light Meter with PC Interface. Model

ASKING FOR ASSISTANCE

B Polling Interface

WARRANTY & LIMITATION OF LIABILITY

User s Manual. Model and Sound Level Calibrators

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

OPERATOR S MANUAL FPD 50 WATT POWER SUPPLY. Flat Pack Single Output DC to DC Converter 50 Watt Output 24 Vdc Nominal Input

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering

MSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays

Plus-X 600. Installation and Operation Manual

USB 400 USER MANUAL.

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

DPT - EN1 R1 Users Manual

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

FieldServer X-25 Start-Up Guide

MTS-2000 USER S MANUAL

4x4 DVI Dual Link Matrix

SD1306. Speed Dome IP Camera. Quick User Guide

RS422 PORT SWITCHER REMOTE CONTROL PANEL

Card Encoder. PC Software. User Manual Software OPW Fuel Management Systems Manual No. M Rev 2

Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP

62532 (EN649) Ethernet Adapter

Section 1 Introduction

Digital Vane Thermo-Anemometer Model

INSTALLATION & OPERATING INSTRUCTIONS

UPGRADABLE FULLY FEATURED POWER & ENERGY METER

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL

Model JI-820 Incremental Encoder Emulator. User Manual

I/O SIGNAL CONDITIONER

PowerMouse Version 1.00 November PowerMouse. The FlarmMouse successor. Version 1.00

Operating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World!

series SIGNUM SYSTEMS CORPORATION Chameleon WEMU51 for the USP-51 Installation Instructions

FES BMS CONTROL MANUAL

CA-A480-A Elevator Controller. Reference & Installation Manual

GE Digital Energy Multilin EPM 4600 Quickstart Guide TELEPHONE: FAX: HOME PAGE:

4x2 DVI Switcher USER MANUAL.

InLinK HM Setup Software Installation & Operation Manual

Skyan. Wireless Control System for Telescopes. Copyright 2007 Belsico Inc. Rev. 1.3

Multilin EPM 4600 Metering Solution

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

CarDAQ-M J2534-1&2 Module Quick Start Guide

MetriNet Cell Modem Manual

Xxxxx Xxxxxx DC Voltage Data Logger

Transcription:

CoPilot EXT PDA Based Software Installation & Operation Manual Revision 1.02 December 3, 2007 Doc #: E156701 V1.02 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel: 516-334-0870 Fax: 516-338-4741 Sales@electroind.com www.electroind.com The Leader in Web Accessed Power Monitoring and Control

Electro Industries/GaugeTech Doc # E156701 V1.02

CoPilot EXT User Manual Version 1.02 Published by: Electro Industries/GaugeTech 1800 Shames Drive Westbury, NY 11590 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage or retrieval systems or any future forms of duplication, for any purpose other than the purchaser s use, without the expressed written permission of Electro Industries/GaugeTech. 2007 Electro Industries/GaugeTech Printed in the United States of America. Nexus and Shark are registered marks of Electro Industries/GaugeTech. Electro Industries/GaugeTech Doc # E158701 V1.02 I

Customer Service and Support Customer support is available 9:00 am to 4:30 pm, eastern standard time, Monday through Friday. Please have the model, serial number and a detailed problem description available. If the problem concerns a particular reading, please have all meter readings available. When returning any merchandise to EIG, a return authorization number is required. For customer or technical assistance, repair or calibration, phone 516-334-0870 or fax 516-338-4741. Product Warranty Electro Industries/GaugeTech warrants all products to be free from defects in material and workmanship for a period of four years from the date of shipment. During the warranty period, we will, at our option, either repair or replace any product that proves to be defective. To exercise this warranty, fax or call our customer-service department. You will receive prompt assistance and return instructions. Send the instrument, transportation prepaid, to EIG at 1800 Shames Drive, Westbury, NY 11590. Repairs will be made and the instrument will be returned. Limitation of Warranty This warranty does not apply to defects resulting from unauthorized modification, misuse, or use for any reason other than electrical power monitoring. Our products are not to be used for Primary Over-Current Protection. Any protection feature in our products is to be used for Alarm or Secondary Protection only. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ELECTRO INDUSTRIES/GAUGETECH SHALL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING FROM ANY AUTHORIZED OR UNAUTHORIZED USE OF ANY ELECTRO INDUSTRIES/GAUGETECH PRODUCT. LIABILITY SHALL BE LIMITED TO THE ORIGINAL COST OF THE PRODUCT SOLD. Statement of Calibration Our instruments are inspected and tested in accordance with specifications published by Electro Industries/GaugeTech. The accuracy and a calibration of our instruments are traceable to the National Institute of Standards and Technology through equipment that is calibrated at planned intervals by comparison to certified standards. Disclaimer The information presented in this publication has been carefully checked for reliability; however, no responsibility is assumed for inaccuracies. The information contained in this document is subject to change without notice. Electro Industries/GaugeTech Doc # E158701 V1.02 II

About Electro Industries/GaugeTech History Founded in 1973 by engineer and inventor Dr. Samuel Kagan, Electro Industries/GaugeTech changed the face of power monitoring forever with its first breakthrough innovation: an affordable, easy-to-use AC power meter. A few of our many Technology Firsts include: 1978: First microprocessor-based power monitor 1986: First PC-based power monitoring software for plant-wide power distribution analysis 1994: First 1 Meg Memory high performance power monitor for data analysis and recording 1999: Nexus Series generation power monitoring with industry-leading accuracy 2000: First low profile socket meter with advanced features for utility deregulation 2002: Innovative 100BaseT Total Web Solutions Today Over thirty years later, Electro Industries/GaugeTech, the leader in Web-Accessed Power Monitoring, continues to revolutionize the industry with the highest quality, cutting edge power monitoring and control technology on the market today. An ISO 9001:2000 certified company, EIG sets the standard for web-accessed power monitoring, advanced power quality, revenue metering, artificial intelligence reporting, industrial submetering and substation data acquisition and control. EIG s products can be found on site at virtually all of today s leading manufacturers, industrial giants and utilities. World Leader In fact, EIG products are used globally and EIG is accepted as the world leader in power monitoring and metering technology. With direct offices in the United States, Turkey, Brazil, Mexico, Guatemala, Croatia and the Phillipines, EIG support is available in most regions around the world. Our worldwide support, advanced technology and quality manufacturing standards make EIG the superior choice when dependable, reliable service is paramount. Electro Industries/GaugeTech Doc # E158701 V1.02 III

Electro Industries/GaugeTech Doc # E158701 V1.02 IV

Table of Contents EIG Warranty ii Chapter 1: Installing CoPilot for Pocket PC 1.1: System Requirements.......................... 1-1 1.2: CoPilot Installation Downloads...................... 1-1 1.3: Connections.............................. 1-2 1.3.1: Connect to Shark 100 meter with IrDA.................. 1-2 1.3.2: Connect to Shark 100 meter with RS485.................. 1-3 1.3.3: Connect to Nexus meter with RS485.................. 1-3 Chapter 2: Configuring with CoPilot 2.1: Configuring Shark 100 meter with CoPilot................ 2-1 Chapter 3: Viewing Data 3.1: Viewing Shark 100 meter Data with CoPilot............... 3-1 3.2: Viewing Nexus meter Data with CoPilot................. 3-2 Electro Industries/GaugeTech Doc # E156701 V1.02 v

Electro Industries/GaugeTech Doc # E156701 V1.02 vi

Chapter 1 Installing CoPilot for Pocket PC 1.1: System Requirements IrDA or USB Port (with USB adapter cable for your Pocket PC) Microsoft ActiveSync installed on your PC or other Pocket PC file transfer software (to make PC to Pocket PC connection) www.microsoft.com/windowsmobile/downloads/activesync37.mspx 1.2: CoPilot Installation Downloads To install CoPilot on your Pocket PC, follow the steps given below. CoPilot can be used with all Nexus meters (with a Unicom 2500) and with the Shark 100 meter. 1. Go to www.electroind.com. Click Downloads at the top of the page (a detail of the Downloads page is shown on the right). 2. Click on the CoPilot EXT Installation link. Select the appropriate.zip file for your Pocket PC and save it to your computer (ArmV4 is recommended). 3. Open the.zip file and extract the.cab and.dat files. Transfer both files onto your Pocket PC s temp directory (in root). From the Pocket PC, click on the.cab file. The CoPilot EXT software should be installed. Transferring Instructions 1. Connect to your Pocket PC with Microsoft ActiveSync or other Pocket PC file transfer software using a USB or IrDA connection. If file transfer software is not already installed, see the documentation that came with your Pocket PC or go to microsoft.com/windowsmobile/downloads. 2. When the Explore option comes up, first go to the My Device directory, then the temp directory. Copy the files to the temp directory. NOTE: CoPilot EXT ArmV4 is the recommended (and most common) install file. If you are unsure which install file to use, choose the CoPilot EXT ArmV4 file. If you know your processor type, you may choose to use one of the following install files: CoPilot EXT ARM, MIPS, SH3, WCE420X86 or X86. Electro Industries/GaugeTech Doc # E156701 V1.02 1-1

1.3: Connections 1.3.1: Connect to a Shark 100 meter with IrDA 1. Locate the IrDA Port on the Pocket PC. 2. Line up the IrDA Port on the Pocket PC with the IrDA Port on the face of the Shark 100 meter. They should face each other and be less than 1 foot apart. 3. Open the CoPilot EXT software. 4. Click the Connect icon. You will see the Connect screen. 5. Select IrDA and Com3 on the Connect screen. 6. Click OK. If a connection is not established, an Error in Transmit Data message will appear: Cannot Connect - Nothing to Communicate with (or) Connection Settings are wrong (Protocol, for example) If the software cannot locate a port, the following message will appear: Port already in use or does not exist 7. Change settings or connections until a connection is established. 8. Click OK in the upper right hand corner of the Connect screen to close the CoPilot EXT program. Electro Industries/GaugeTech Doc # E156701 V1.02 1-2

1.3.2: Connect to a Shark 100 meter with RS485 Hardware Requirements: Pocket PC with Serial Cable and Unicom 2500 (RS485 to RS232 Converter) 1. Attach the Serial Cable from the RS485 port on the back face of the Shark 100 meter to the RS485 connection of the Unicom. 2. Connect the RS232 connection of the Unicom to the RS232 cable of the Pocket PC. The Unicom settings are: DTE, 57600 Baud, HD (Half Duplex) 3. Open the CoPilot EXT software. 4. Click the Connect icon. You will see the Connect screen. 5. Select Serial Port. Enter Device Address, Baud Rate and Protocol. The Com Port setting is usually COM1, but you can select from COM1 to COM16. 6. Click Connect. You will see the Device Status screen. This is a View Only screen. 7. Click OK to continue to the selection screen. 1.3.3: Connect to a Nexus meter with RS485 Hardware Requirement: Pocket PC with Serial Cable, Unicom 2500 (485 to 232 Converter) and 9- pin male to male adapter. 1. Attach the Serial Cable from the RS485 port (Port 1) on the face of the Nexus meter (A+ B- S) to the RS485 connection of the Unicom. The corresponding connection on the Unicom is: A+ (TX+/RX+), B- (TX-/RX-), S (GND). A male to male 9-pin adapter is required to make this connection. 2. Connect the RS232 connection of the Unicom to the RS232 cable of the Pocket PC. The Unicom settings are: DTE, 57600 Baud, HD (Half Duplex) 3. Open the CoPilot EXT software. 4. Click the Connect icon. You will see the Connect screen. 5. Select Serial Port. Enter Device Address, Baud Rate and Protocol. Com Port setting is usually COM1, but you can select from COM1 to COM16. 6. Click Connect. You will see the Device Status screen. This is a View Only screen. 7. Click OK to continue to the selection screen. Electro Industries/GaugeTech Doc # E156701 V1.02 1-3

Electro Industries/GaugeTech Doc # E156701 V1.02 1-4

Chapter 2 Configuring with CoPilot 2.1: Configuring a Shark 100 meter with CoPilot The Device Profile screens for the CoPilot - Shark 100 meter Interface are very easy to use. First, follow the directions in Chapter 1 to establish a connection. 1. Open the CoPilot EXT software. You will see the Main screen. 2. Click on the Profile icon. Scaling Use the pull-down windows to make the following selections: CT Multiplier: 1, 10 or 100 PT Multipler: 1, 10 or 100 System Wiring: 3 Element Wye, Delta 2 CTs or 2.5 Element Wye For CT Numerator, PT Numerator and PT Denominator, use the Keyboard in the lower right hand corner of the screen. a. Click on the Keyboard icon. b. Enter the settings. c. Click OK. Electro Industries/GaugeTech Doc # E156701 V1.02 2-1

Communications Use the pull-down windows to make the following selections: Response Delay (COM 1 and COM 2): 0-750 ms (increments of 50ms) Protocol: Modbus RTU or Modbus ASCII Baud Rate: 9600-115,200 For Address, use the Keyboard in the lower right hand corner of the screen. a. Click on the Keyboard icon. b. Enter the settings. c. Click OK. Buttons Click Update to update the Device Profile. Click Communication to view the Communication screen. Click OK to return to the Main screen. Updating the Device Profile 1. Click Update after you have made changes to settings. This will update the Device Profile of the Shark 100 meter. The meter will then Reset. After Reset is completed, CoPilot will attempt to reconnect. 2. When Programming Complete appears, click OK. NOTE: If Comm Settings were changed, you must exit the program from the Connect screen and reconnect with the new settings. Electro Industries/GaugeTech Doc # E156701 V1.02 2-2

Chapter 3 Viewing Data 3.1: Viewing Shark 100 Meter Data with CoPilot Once a connection has been established and any configuration is done, you are ready to View Data. 1. Open the CoPilot EXT software. You will see the Main screen. 2. Click on the View Data icon. You will see the View Data screen, shown below, on the right. Select Data to View 3. Click on the Icon for the type of data you want to view. You will see Real Time Data for the type of data you selected. (The meter is polling continuously.) Screen Data VOLTAGE AND FREQUENCY Screen A-N, B-N, C-N, A-B, B-C, C-A POWER Screen Totals for W, VAR, VA and PF PHASORS Phasor Diagram, VAN, VBN, VCN, IA, IB, IC CURRENT Screen Instantaneous Current Readings A, B, C ENERGY Screen Instantaneous Energy Readings for Delivered Wh, Received Wh, Delivered VARh, Received VARh, VAh DEVICE STATUS Device ID & Type, Boot, Run-Time, DSP Boot, Run-Time Exit Click OK to Exit this screen and return to the Main screen. Electro Industries/GaugeTech Doc # E156701 V1.02 3-1

3.2: Viewing Nexus Meter Data with CoPilot Once a connection has been established, you are ready to View Data. 1. Open the CoPilot EXT software. You will see the Main screen. 2. Click on the View Data or the Retrieve Logs icon. You will see one of the following screens. View Data 3. Click on the Icon for the type of data you want to view. Real Time Data appears for the type of data selected. (The meter is polling continuously.) Screen Data VOLTAGE AND FREQUENCY Select 1 sec or.1 sec readings A-N, B-N, C-N, A-B, B-C, C-A, AUX, FREQ POWER Screen Select 1 sec or.1 sec readings Totals for W, VAR, VA and PF ENERGY Instantaneous Energy Readings for Delivered Wh, Received Wh, Delivered VARh, Received VARh, VAh THD Channel Selection: VAN, VBN, VCN, IA, IB, IC Harmonics Spectrum, % THD Factor, K Factor, Zoom DEVICE STATUS Device ID, Device Type, Boot, Run-Time, DSP Boot and Run-Time, Protection (Password) CURRENT Select 1 sec or.1 sec readings A, B, C, NC, Nm POWER PHASES Screen A, B, C for W, VAR, VA and PF Electro Industries/GaugeTech Doc # E156701 V1.02 3-2

PHASORS Phasor Diagram, VAN, VBN, VCN, IA, IB, IC INPUTS 8 Labeled High Speed Inputs with Status for each LOG STATUS Number of Records and Memory Used for the following logs: Historical Logs 1 & 2 Limit Triggers Digital Inputs Digital Outputs Waveform / PQ System Events Retrieve Logs 1. Click on the Retrieve Logs Icon. The Retrieve Logs screen for the connected device appears. The screen lists the available logs for that device with a check box in front of each log. 2. Select the Log(s) you want to retrieve from the screen. 3. Click OK. The software retrieves the Programmable Settings for the connected device and then retrieves the selected logs. The software downloads the logs to a file labelled: meter name.db. Electro Industries/GaugeTech Doc #: E156701 V1.02 3-3

Electro Industries/GaugeTech Doc #: E156701 V1.02 3-4