ESCA 2000 UPGRADE V ESCA 2000 V102 is compatible with NT 4.0, Windows 2000 and XP. It comes in five versions.

Similar documents
HIGHLIGHTS OF NEW FEATURES TOPICAL DESCRIPTION OF SOFTWARE

Bridge Cable User s Guide

Spectrometer Visible Light Spectrometer V4.4

Quick Installation Guide: QUARC TM on NI ELVIS III

Installation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10

II.1 Running a Crystal Report from Infoview

Setting up FT3000 and version on Windows 7. This is a step by step guide for setting up the FT3000 on a new Windows 7 or 8 PC

Copyright Autodesk, Inc.

Thank you for purchasing Qwizdom Remotes.

Installing the IBM ServeRAID Cluster Solution

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

Sharing Data between Applications Connecting 2 PC s running ic/icontrol

MAN0314/2.00. Software update summary

Getting Started With DO Analyser Software Version 4

ION Demo Kit. Quick Start Guide PERFORMANCE MOTION DEVICES

Installation Guide. Cornerstone* 8.5 NEXT Software and IDEXX-PACS* Imaging Software. Plan for your upgrade

Tempress System Controller_II Reference Manual

Procedure to set up an HPIB 82350B card on an M57. M58 or C20x PC. Table 1: Parts required. Part Number Description Qty

Network Setup 2.0

CONTENTS. SysReturn_Manaual Updata 06/4/24. Chapter1 Introducing SysReturn Introduction to SysReturn Features and Functions...

Lab 03. Windows Operating Systems (Cont.)

VI-CENTER EXTENDED ENTERPRISE EDITION GETTING STARTED GUIDE. Version: 4.5

WinMarkpro v6 for the FH Marking Head Quick Start Guide

PCI/PXI Gigabit Ethernet Adapters

This document provides additional information for the installation and use of the Keithley I/O Layer.

Jasco FP-6500 Spectrofluorimeter Updated November 14, 2017

DOWNLOAD KIT CYCLOCOMPUTER INTRODUCTION. Download unit & Download Software [e-train Data Ver.3] for Windows 98/ME/2000/XP

Agilent G1701DA MSD Productivity ChemStation Software

Windows Me Plug-and-Play

VIRTUALIZATION MANAGER ENTERPRISE EDITION GETTING STARTED GUIDE. Product: Virtual Iron Virtualization Manager Version: 4.2

System Requirements. Package Contents

Technical Bulletin DS2

Getting Started. ContrexHost 3. Suite of Serial Communications Applications for Contrex Motion Controls

PC RateLink (Open-i) Guide

Operation manual. DeviceControl NomadLink Network Control and Monitoring Software. Rev Item no. OM-DC

MoCo SMS Suite User s Manual

RTE for WIN32. Installation Manual (Rev.7.0) Midas lab

Sciex QTrap Operational Steps for Trained Personnel

Advantech Studio Quick Start Manual

Agilent MassHunter LC/SQ ChemStation Integration Software

UNIVERGE SV8500 SOFTWARE UPGRADE PROCEDURE FROM S5 TO S6

INSIGHT Installation Instructions

Workstation Setup Instructions Release 9.5

ZAVANTA Standalone Installation

CD-ROM Image Viewer Installation Guide M&T Bank. Member FDIC.

Windows NT Server Printer Driver Upgrade Instructions

1. Installing the Drivers for Windows

Quick Start Guide PCM600 for Relion 650/670 Series

SAS Installation Instructions Windows 2003, XP, 2000, NT. Workstation Installation Guidelines

IVC-100/100G & IVC-200/200G & IVC-120/120G

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

IT 341 Introduction to System Administration Project I Installing Ubuntu Server on a Virtual Machine

GV Director Restoring USB Image / Frame and Panel Installation

VCI - Virtual CAN Interface VCI-V3 Installation Manual

Windows 7 Professional 64 bit Installation and Configuration for MassLynx or Empower Controlled Ethernet Instrument Communication

USB TO SERIAL CONVERTER

PropertyBoss Upgrade

Software Release Notice TimeScan For Windows 2000/XP/Vista Release 8.7

Windows XP Software Installation Instructions GCC Elite Series Printers

You might think of Windows XP as a set of cool accessories, such as

Contact Center Supervisor Manual

Chapter 1. Introduction. System Requirements. Supports High Resolution graphics modes

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

How to install the software of ZNS8022

RALS Remote Connect (RRC) Version 2.2 Installation and Configuration Instructions

ARES. User s Guide. Aprilia Racing Engine Setup. English version

Install Manual. P2 Software ENGLISH

Unified Messenger 4.02 Installation Guide

NET-DYN USB Dual Band (Mediatek) Installation Guide. This manual is divided into three parts: Windows XP, Windows 7 / 8 / 8.

INSTALLING THE FMS 5.3.x SOFTWARE

READ THIS INFORMATION FIRST Product: Remote IO Manager Software Release Remote IO Manager w/ Cable. Remote IO Manager Branding Toolkit.

USB driver and Software Installation. UPS Monitoring and Management Software

HOW TO: Upgrade Windows XP to Windows 7 with Windows Easy Transfer

User's Manual V 32.0

WE-20 Remote Control Installation Instructions

MFC790CW Windows Network Connection Repair Instructions

User Guide 701P Wide Format Solution Wide Format Scan Service

Windows 98 Manual Driver Installation

INSTALLATION AND STARTUP

D100 ISM Step by Step Installation Guide

EUTAXA-Installation: Troubleshoot Guide

Keithley Instruments ExceLINX-3A ExceLINX software for the Model 2000 Release Note for Version C02 3/26/2015

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup

Compact Contact Center Installation Manual

Network Device Installation Software DeviceInstaller

Galileo Print Manager Installation Guide

Step-by-Step Guide to Installing Cluster Service

Reinstalling the Operating System on the Dell PowerVault 745N

Cover. MATWorX Installation Guide NWA ISSUE 2.1

Print Server using HPMv7 Customer Installation Document

Section 4: Installing the ECC (Epilog Control Center)

Laser Beam Printer. Network Guide. IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference.

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.

RC-SV Configuration Guide (Rev 4)

Blackbaud StudentInformationSystem Update Guide

Deploying HP SIM 6.x on MSCS clusters on Windows 2008 with SQL Server 2008 SP1 White Paper

Port Connections This section covers parallel and Ethernet connections.

USING THE VENABLE RLC WINDOWS SOFTWARE VERSION 4.5

User Guide for ID-e Tag List Feature

Technical Information

Transcription:

ESCA 2000 UPGRADE V102.02 ESCA 2000 V102 is compatible with NT 4.0, Windows 2000 and XP. It comes in five versions. ESCA 2000 A - ESCA 2000 B - ESCA 2000 D - ESCA 2000 E - ESCA 2000 G - Standalone Data Analysis ESCA Capture and Analysis, No Motion Control Demo only. Can Not run Instrument ESCA Capture and Analysis Ethernet communication to new 4 axis controller. ESCA Capture and Analysis GPIB communication to old 2100 Indexers. The following improvements are included: 1. Export to Vamas and EXCEL from the Analysis Application. Peak fit curves and backgrounds can also be exported to EXCEL. 2. Import from the DOS Vectra data files. 3. Editing of the Scofield tables from the Analysis Application 4. Backup and Compact of database from Analysis Application 5. Improved Assignment of Elements after auto-find. Just click on the BE label that marks the peak center. Then select the Element and Transition from the list. 6. New Tools for add, subtract, smooth, differentiate integrate and satellite subtract. 7. Axes are labeled. 8. Auto compact of database each time the database is loaded. The compact can not take place if the database also open by another program. It will simply load. 9. Depth profile capture has a number of major bugs fixed. It runs much better. 10. Time can be entered as second (as large as desired), mm:ss or hh:mm:ss. Your may use number of scans or time for scanned spectra. The program will compute the number of scans from the time. The time will exceed the request to allow for completion of the last scan. 11. A Capture Settings has been added under the settings menu in the Capture Application. This provides a number of instrument settings that should be reviewed. Support for non-monochromatic X-ray sources is included. 12. Improved print out template. 13. Much improved manual is included on the CD. 14. Minor bugs in the calibration program have been fixed. Thank you for supporting our continuing effort to bring the Surface Science ESCA users a productive software program. Very truly Yours Bob Chaney i

QUICK UPGRADE INSTRUCTIONS 1. Use windows software install/uninstall to remove the current ESCA 2000 programs. Select remove all shared files. 2. Check the C:\Program Files\ESCA 2000 folder. Make a copy of the sig.txt file and the Start.mdb file. These may be copied over by the upgrade. If a Viewer folder remains delete the View.ocx and the Viewer folder. 3. Check the C:\Wnnt\System32 folder. Be sure your explorer is set to view system files.dll,.ocx,.sys etc. Go to the bottom of the list of files and look for any files that start with xps or xprob. Delete any such file. 4. Place the CD in the CD drive and open the CD Install ESCA 2000 B folder. Open the ESCA 2000 B folder and double click on the Setup.exe icon. During installation you may receive a notice that the files being loaded are not newer than the files on your hard drive. Do you want to keep your files. You should keep all system files (they end in.dll,.ocx etc). You may keep your start.mdb file. Do not keep the Programdb.mdb and the ESCATemplate.mdb file that is on your drive. 5. Replace the sig.txt file loaded by ESCA 2000 V1.02 with the file you saved in step 2. You may delete the newly installed start.mdb file and copy back the Start.mdb you save above. 6. This upgrade will not effect your calibration settings. You will not need to reregister this program. If you have any questions please call. 541-318-8688 ii

Installation Overview 1. New installations a. Computer check list i. Set up CMOS BIOS for IRQ 10. Hit Delete button during boot-up to access CMOS BIOS. Select PCI/PnP set up. Reserve IRQ 10 slot for ISA/EISA operation. ii. Three each 2420 GPIO cards must be installed in ISA slots. The cards have jumper blocks to determine their I/O address and IRQ number. The card parameters are: 1. Detector board Nbr. 12 I/O 280 IRQ 10 2. Spectrometer board Nbr. 13 I/O 2C0 None 3. Accessories board Nbr. 14 I/O 300 None iii. National Instruments GPIB 488.2 interface card for original motion system interface. Use Driver Version 1.7 with NT operating system. Driver Version 2.0 with Windows 2000 operating system. Install and verify before installing ESCA software. Driver V 2.0 is on ESCA 2000 CD. iv. Install a dedicated Ethernet card for use with new 6K4 Motion system. If a GPIB card is present it should be disabled or removed. The Ethernet card should have a TCP/IP Internet protocol installed. The card IP address can NOT be assigned automatically. Assign a fixed address of 10.0.0.100 and a subnet mask of 255.255.255.0. No other entries are required. v. Run the latest Service Pack for the operating system. SP6a for NT or SP3 or later for Windows 2000. b. Software checklist. i. This instruction is used for all five installation CD s. Find your installation situation in the following directions. Use only the short instruction set that pertains to your situation. ii. On the CD s for full system installation,(b, G and E) you will find Folders named ESCA 2000 B, G or E and a folder ESCA 2000 A. Folder 2000 A is available for installation of the Data Analysis program on a standalone computer. The folder ESCA 2000 B, G or E contains a full installation of both the ESCA Capture and ESCA Data Analysis applications. There is no need to make a separate installation of ESCA 2000 A. iii. In upgrades your existing Database files will be left in place. The ESCAVB folder will not be removed. iv. You will find you old sig.txt file in the ESCAVB folder and a new blank sig.txt file in the ESCA 2000 folder. If you use signature correction you should copy your old sig.txt file to the new ESCA 2000 folder. To set up iii

signature use Main Toolbar > Settings > Capture Preferences then supply path to your sig.txt file. v. When the program is first started it may be unable to find a database to open. Ignore the message and let the application open with out a database. Then use the file menu to open any database you choose. This will get the program started. iv

Installation Instructions General comments The CD ROM contains a complete program for first time installation. This program can be used for new installations or for upgrading an existing program. If it is used to upgrade an existing program there will be no need to register the installation. The upgrade process is also greatly simplified. The CD ROM contains a number of folders. Various folders are required depending on the operating system and depending on rather a new installation or an upgrade is performed. You may need the CD at a later date so keep it handy. We assume knowledge of general Windows file operations. If this instruction lacks sufficient detail please free to call and ask for assistance. You won t be put in a long hold queue. We will use a shorthand description. The key word Folder means go to the named folder and open it to find the named file. Next we will give the file name. Double click the file to open it. All of the named files will install the desired program. Next we will describe actions that must be taken before the next step in the installation. New Installation If upgrade from ESCAVB skip this section. Windows NT 4.0 New Instillation of ESCA 2000 series. A. ESCA 2000 A (NT, new) Folder NTsp6a.. Folder MDAC Folder ESCA 2000 A Install file sp6i386.exe. Updates service pack 6a Install file mdac-typ.exe. Install MDAC services. Install file setup.exe. Installs Data Analysis. RUN > Programs > ESCA Data Analysis A. If there are warnings about not loading files just continue. Follow directions. You will be given a Serial Number that is unique to your computer. Call Barbara or Bob at Service Physics, Inc., 541-318-8688, and The next time you start the application it will provide a different number. Don t send us a serial number and then shut down the computer. v

B. ESCA 2000 B (NT, new) Folder NTsp6a.. Folder MDAC Folder ESCA 2000 B Install file sp6i386.exe. Updates service pack 6a Install file mdac-typ.exe. Install MDAC services. Install file setup.exe. Installs Capture and Analysis. RUN > Programs > ESCA 2000 > ESCA Data Analysis B. If there are warnings about not loading files just continue. See note above on sig.txt. Follow directions. You will be given a Serial Number that is unique to your computer. Call Barbara or Bob at Service Physics, Inc., 541-318-8688, and Don t send us a serial number and then shut down the computer. C. ESCA 2000 D (NT, new) Folder NTsp6a.. Folder MDAC Folder ESCA 2000 D Install file sp6i386.exe. Updates service pack 6a Install file mdac-typ.exe. Install MDAC services. Install file setup.exe. Installs Capture and Analysis. RUN > Programs > ESCA 2000 > ESCA Data Analysis G. If there are warnings about not loading files just continue. See note above on sig.txt. Follow directions. You will be given a Serial Number that is unique to your computer. Call Barbara or Bob at Service Physics, Inc., 541-318-8688, and Don t send us a serial number and then shut down the computer. vi

D. ESCA 2000 E (This version cannot be loaded on NT) E. ESCA 2000 G (NT, new) Install the GPIB card and the National Instruments driver according to National Instruments instructions. You should be sure the driver is version 1.7. Go to www.ni.com to obtain this driver if not available. Use the Ni 488.2 Getting Started utility to test you installation. Be sure the communication to the GPIB card is established before continuing. Folder NTsp6a.. Folder MDAC Folder ESCA 2000 G Install file sp6i386.exe. Updates service pack 6a Install file mdac-typ.exe. Install MDAC services. Install file setup.exe. Installs Capture and Analysis. RUN > Programs > ESCA 2000 > ESCA Data Analysis G. If there are warnings about not loading files just continue. See note above on sig.txt. Follow directions. You will be given a Serial Number that is unique to your computer. Call Barbara or Bob at Service Physics, Inc., 541-318-8688, and The next time you start the application it will provide a different number. Don t send us a serial number and then shut down the computer vii

Windows 2000 operating system New Installations of ESCA 2000 series. Note: YOU ONLY NEED to install Windows Service Pack 3 (sp3) or higher if it is not already installed. This is true for ALL ESCA 2000 installations on Windows 2000. F. ESCA 2000 A (Win 2000, new) Folder 2000SP3. Folder ESCA 2000 A Install file sp3express.exe. If required Install file setup.exe. Installs Data Analysis. RUN > Programs > ESCA Data Analysis A. If there are warnings about not loading files just continue. Follow directions. You will be given a Serial Number that is unique to your computer. Call Barbara or Bob at Service Physics, Inc., 541-318-8688, and Don t send us a serial number and then shut down the computer. G. ESCA 2000 B. (Win 2000, new) Folder 2000SP3 Folder ESCA 2000 B Install file sp3express.exe. If required Install file setup.exe. Installs Capture and Analysis. RUN > Programs > ESCA 2000 > ESCA Data Analysis B. If there are warnings about not loading files just continue. See note above on sig.txt. Follow directions. You will be given a Serial Number that is unique to your computer. Call Barbara or Bob at Service Physics, Inc., 541-318-8688, and Don t send us a serial number and then shut down the computer. viii

H. ESCA 2000 D (Win 2000, new) Folder 2000SP3 Folder ESCA 2000 D Install file sp3express.exe. If required Install file setup.exe. Installs Capture and Analysis. RUN > Programs > ESCA 2000 > ESCA Data Analysis D. If there are warnings about not loading files just continue. See note above on sig.txt. Follow directions. You will be given a Serial Number that is unique to your computer. Call Barbara or Bob at Service Physics, Inc., 541-318-8688, and Don t send us a serial number and then shut down the computer. I. ESCA 2000 E. (Win 2000, new) Connect Ethernet crossover cable between computer and 6K4 controller. Also connect RS232 cable between computer and 6K4 controller. Connect Joystick to USB port. Go to Start > Settings > Control Panel and select the Game Controllers Icon. The dialog will list the controller as CH 3Axis/4 button OEM and the status as OK. Select the Properties button in the lower right of the dialog. A test panel will be displayed. Play with the joystick to verify that all motions are active. Go to CD ROM. Folder CH Products Install file SETUP.exe. Installs driver/mapper. After message that Aux1 and Aux2 drives are installed then reboot computer. Folder Motion Planner Install file Motion Planner.exe Installs 6K4 driver. 2000 Install file SETUP.exe Installs Run Time Access. Folder ESCA 2000 E Install Setup.exe. Installs Capture, Data Analysis, Joystick Test and Ethernet Setup (SixKWiz). On the computer desk top select ix

Programs > ESCA 2000 > Ethernet Setup Set motor connection to 6K4 and turn on all axes that are installed. Click next. Compare the Ethernet and Hardware addresses entered into the registry and those recovered from the 6K4 controller. The program will attempt to set the registry correctly. The IP address should be 10.0.0.10 for both entries. The hardware address will be 00-90-55-00-xx-yy. Where the values for xx and yy are unique for each 6K4 controller. If the setup program has problems a message will be provided. Call Service Physics, Inc. if this step fails. Click Next. Click the Test connection button. The message should read: Ping succeeded. If the Ping failed then close the dialog. Turn off the 6K4 controller for 30 seconds to reset its communication interface. Reboot the computer to reset the registry configuration. Reopen the ESCA 2000 Ethernet Setup wizard. Step through the wizard. The ping should be successful. Click Next. Let the wizard start the Joystick maper. If the Wizard cannot find the map browse to: C:\Program Files\CH Products\OEM Maper\Maps. Open Bob1.map The map must be Activated, Enabled and Calibrated. These are the 4,6 and 7 Icons reading left to right in the toolbar. Follow the instruction on calibration of the Joystick. Finish the Ethernet setup wizard. You will find a Snoopy Icon in the Windows Tray in the lower right corner of the Windows desktop. Snoopy lives by the clock. Right mouse click Snoopy. Choose open from the menu. The dialog has 4 blue bands, one for each axis. Each band should cover its axis window from the left edge to the center of the window. As you move each axis of the Joystick the blue band should reflect your motion. Test each motor. Try various speed settings. Snoopy must be installed for the Joystick to operate. You may hide the setup dialog. Click the Form close box in the upper right corner of the form. Then select Hide. Snoopy will continue to be displayed in the tray. If Snoopy is closed he may be reopened. Go to Start > Programs > ESCA 2000 > Joystick Test. RUN > Programs > ESCA 2000 > ESCA Data Analysis E. If there are warnings about not loading files just continue. See note above on sig.txt. Follow directions. You will be given a Serial Number that is unique to your computer. Call Barbara or Bob at Service Physics, Inc., 541-318-8688, and Don t send us a serial number and then shut down the computer. x

J. ESCA 2000 G. Install the GPIB card in computer. Folder NI488.2 2000 Install file ni488220.exe Installs GPIB driver. Use the Ni 488.2 Getting Started utility to test you installation. Be sure the communication to the GPIB card is established before continuing. Folder 2000SP3 Folder ESCA 2000 G Install file sp3express.exe. If required Install file setup.exe. Installs Capture and Analysis. RUN > Programs > Esca 2000 > Esca Data Analysis G. If there are warnings about not loading files just continue. See note above about sig.txt. Follow directions. You will be given a Serial Number that is unique to your computer. Call Barbara or Bob at Service Physics, Inc., 541-318-8688, and Don t send us a serial number and then shut down the computer. xi

Upgrade from ESCAVB Windows NT 4.0 and Windows 2000 A. ESCA 2000 A. (upgrade ESCAVB) Navigate to Start > Settings > Control Panel > Add/Remove programs. Remove ESCAVB. If ask if you want shared programs removed select [Yes to All] Folder ESCA 2000 A Install file setup.exe. Installs Data Analysis. If you are informed that the file being loaded is not newer than the file on your computer. Would you like to keep your file? Say Yes. (You want to keep the newer file.) RUN > Programs > ESCA Data Analysis A. If there are warnings about not loading files just continue. B. ESCA 2000 B, D or G. (Upgrade ESCAVB) Navigate to Start > Settings > Control Panel > Add/Remove programs. Remove ESCAVB. If ask if you want shared programs removed select [Yes to All] Manually delete Viewer.ocx form C:\Program files\escavb\viewer. Also delete the following from ESCAVB folder: Gviewer.exe All files ending in.ocx All files ending in.dll Viewer folder Folder ESCA 2000 B, D org. Install file setup.exe. This installs both the Capture and Data Analysis. If you are informed that the file being loaded is not newer than the file on your computer. Would you like to keep your file? Say Yes. (You want to keep the newer file.) RUN > Programs > ESCA 2000 > ESCA Data Analysis B, D or G. If there are warnings about not loading files just continue. See note above about sig.txt. xii

Upgrading from NT to Windows 2000 This upgrade has had mixed results. It is very important to have drivers for Windows 2000 for your Video Card and Ethernet card. Some read/write CD drives require drivers from the manufacture. Our CD supplies the driver for the GPIB if it is used. You must work through the upgrade and establish the Windows 2000 environment with at least Service Pack 3. IF GPIB is used uninstall the V 1.7 driver and install the V 2.0 driver on the ESCA 2000 CD. Be sure to reboot after the driver is installed. We have found the most reliable results are obtained if the ACCESS 2000 Runtime is uninstalled and then reinstalled from the ESCA 2000 CD. With these precautions in mind use the (Win 2000, new ) installation procedures after preparing the Windows 2000 environment. Upgrading ESCA 6K4 installations A. ESCA 2000 E (Win 2000, upgrade existing 6K4 installations) Navigate to Start > Settings > Control Panel > Add/Remove programs. Remove ESCAVB. If ask if you want shared programs removed select [Yes to All] Delete Viewer.ocx form C:\Program files\escavb\viewer Delete following from ESCAVB folder: TestJoystick.exe Gviewer.exe All files ending in.ocx All files ending in.dll Viewer folder Folder ESCA 2000 E. Install file setup.exe. If you are informed that the file being loaded is not newer than the file on your computer. Would you like to keep your file? Say Yes. (You want to keep the newer file.) This installs ESCA Capture, Data Analysis, Joystick Test and Ethernet setup. The new Ethernet setup will eliminate many of the problem with the Ethernet connection. Programs > ESCA 2000 > Ethernet Setup Set motor connection to 6K4 and turn on all axes that are installed. Click next. Compare the Ethernet and Hardware addresses entered into the registry and those recovered from the 6K4 controller. The program will attempt xiii

to set the registry correctly. The IP address should be 10.0.0.10 for both entries. The hardware address will be 00-90-55-00-xx-yy. Where the values for xx and yy are unique for each 6K4 controller. If the setup program has problems a message will be provided. Call Service Physics, Inc. if this step fails. Click Next. Click the Test connection button. The message should read: Ping succeeded. If the Ping failed then close the dialog. Turn off the 6K4 controller for 30 seconds to reset its communication interface. Reboot the computer to reset the registry configuration. Reopen the ESCA 2000 Ethernet Setup wizard. Step through the wizard. The ping should be successful. Click Next. Let the wizard start the Joystick maper. If the Wizard cannot find the map browse to: C:\Program Files\CH Products\OEM Maper\Maps. Open Bob1.map The map must be Activated, Enabled and Calibrated. These are the 4,6 and 7 Icons reading left to right in the toolbar. Follow the instruction on calibration of the Joystick. Finish the Ethernet setup wizard. You will find a Snoopy Icon in the Windows Tray in the lower right corner of the Windows desktop. Snoopy lives by the clock. Right mouse click Snoopy. Choose open from the menu. The dialog has 4 blue bands, one for each axis. Each band should cover its axis window from the left edge to the center of the window. As you move each axis of the Joystick the blue band should reflect your motion. Test each motor. Try various speed settings. Snoopy must be installed for the Joystick to operate. You may hide the setup dialog. Click the Form close box in the upper right corner of the form. Then select Hide. Snoopy will continue to be displayed in the tray. If Snoopy is closed he may be reopened. Go to Start > Programs > ESCA 2000 > Joystick Test. RUN > Programs > ESCA 2000 > ESCA Data Analysis E. If there are warnings about not loading files just continue. See note above on sig.txt. Follow directions. xiv