PowerXL DG1 Redundant Drive Application

Similar documents
PowerXL DG1 Firmware Release Note

Operating a PowerXL DC1/DE1 Drive with a Rockwell PLC on Ethernet/IP

How to control and monitor up to 16 Motor Insight motor protection relays via an HMi and Modbus serial

Power Xpert incontrol One Installer Release Note

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

Operating Instructions Extended Cascade Controller MCO 101

PowerXL PC Tools Eaton Corporation. All rights reserved.

Optidrive Applications Support Library

Operating a Power Xpert C445 Global Motor Management Relay with a Rockwell PLC via Ethernet/IP

Vacon HVAC100 Commissioning Guide

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

SPX 1hr product overview Eaton Corporation. All rights reserved.

LOW VOLTAGE BLDC MOTOR CONTROLLER

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

Motion Control Products Application note Implementing safety functions on ABB servo drives

TR150 DRIVE STANDARD FEATURES

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 4

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

1 Extended and Advanced Cascade Controller Option 3

Quick Start Guide RSi S Series VFD. Using the 7-segment (4 digit LED) Keypad/Display

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SVX9000 Adjustable Frequency Drives. Modular, Configurable, Compact

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings

User Guide VLT Parallel Drive Modules

Optidrive Applications Support Library

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

HART INTERFACE FOR INTELLI+

Ocean Controls KTA-224 Modbus IO Module

DATRAN XL4 PLUS RTU Quick Start Guide

PowerFlex 400 AC Drive Guide Specification

MAKING MODERN LIVING POSSIBLE. VLT AQUA Drive Cascade Controller Options MCO 101/102 Operating Instructions

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26

Power Xpert Branch Circuit Monitor

PowerXL DG1 Product Overview Eaton Corporation. All rights reserved.

PowerXL Series Trouble Shooting Guide

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

How to Configure the DE1 Variable Speed Starter for Reversing Motor Starting Applications.

Operating comfort redefined Frequency Inverters M-MAX

PLC CommuniCations In This Chapter...

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Welcome to the safety functions configuration training module for ACS880 Cabinet-built industrial drives.

Practical Programmable Logic Controllers (PLCs) for Automation and Process Control. Contents

JOCKEY FIRE PUMP CONTROL MODEL: FPC Series

SmartWire-DT In-panel and on-machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

VFD with Bypass package for HVAC Applications. Introducing the ABB E-Clipse Bypass

-----other notes This picture was taken from here:

Power Xpert C445 Motor Management Relay Cheat Sheets

FANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook

Starter and Circuit Breaker Application with PowerFlex 7000

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

SmartFan Cirrus-9. Speed Control and Alarm for 4-Wire Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

Eaton Frequency Inverters SVX9000 and SPX9000. Modular, compact and configurable

FREQUENCY CONVERTER FC102 (QUICK GUIDE)

Safe shutdown of SIRIUS 3RA6 compact starters with IO-Link interface. SIRIUS Industrial Controls, Safety Integrated, IO-Link FAQ 05.

Distributed Power System SB3000 Synchronous Rectifier &RQILJXUDWLRQDQG3URJUDPPLQJ

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

TelePACE Studio Ladder Logic Training Manual

FREQUENCY CONVERTER FC101 (QUICK GUIDE)

PROGRAMMING MANUAL IM262R00. AQUAVAR Intelligent Pump Controller START-UP GENIE PROGRAMMING MANUAL

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FSCA-01 RS-485 adapter module User s manual

User s Manual E-Clipse Bypass Configurations (BCR, BDR, VCR, or VDR) for ACH550 Drives (1 400 HP)

INCOM communications adapter module

SED2 Variable Frequency Drives

DS2020SingleAxis ExtremelyCompact ServoDrives

OPTIDRIVE PLUS 3 GV 3 rd Generation Vector Control AC Variable Speed Drive kW

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

FTA3100 Series Setup and Operating Instructions

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

vacon 100 hvac ac drives application manual

Supplementary operating instructions for your air curtain system Controller TMC 500

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

SENSORLESS VECTOR CONTROL

CIP Safety for Drives

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

Peristaltic Cased Tube Pump

AP070002EN Differences between ELC series and ELC2 series PLCs

Series NRX drawout circuit breaker and cassette rejection interlocks

A66SM Installation and Programming Manual

VLT 2800 DRIVE SPECIFICATIONS

SMART RELAY SRW 01 V4.0X

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

5KW Parallel Installation Guide

DC1 Series 10 min Product Overview Eaton Corporation. All rights reserved.

Analog Output Module Installation Instructions

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

Pulsafeeder Technical Bulletin

Improving monitoring and control hardware cost at Totten Mine

Deaerator and Surge Tank Control

E7B Drive / Bypass System with TouchPad Control Panel (option T or Y) Control Wiring and Start-up Procedure

GRUNDFOS INSTRUCTIONS. Grundfos Modular Controls. for wastewater pumping stations WW 2 application, version V03.00

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Instructions. Modbus RTU Card (WSIQ-COM-MB)

Transcription:

pplication Note P040112EN PowerXL DG1 Redundant Drive pplication Introduction The Power XL DG1 is capable of operating a redundant drive scheme when using the internal PID controller in the drive. This system will utilize two drives with one drive as the Master drive and a secondary drive as a backup. This scheme will use the RS485 communication bus to communicate between the two drives. If the master drive fails due to a fault or a motor interlock is removed, the secondary drive will be brought in and allow the system to keep running. dditional isolation can be built into the scheme to provide the ability to physically replace a drive if one has failed while allowing the other drive to operate the system. System Configurations The system setup for this redundant drive application will include two adjustable frequency drives of the same rating, appropriate input protection, input isolation contactors or disconnect devices, output contactors, and a single motor. The output of both drives will be wired into two output contactors and combined to feed to the motor. This setup will allow for either drive to supply power to the motor. y adding a disconnect before each drive, a failed drive can be replaced while having the backup drive continue to operate the system. This typical setup is detailed in Figure 1 below. In most cases, this redundant drive setup will be used with two drives and a single motor as described above. However, the system could also be set up to utilize two drives each wired to its own motor. This system would utilize the same components as described above, except the output contactors would be wired to the respective motors and not combined to the same motor. This alternative setup is shown in Figure 2 below. This configuration provides redundancy for the drives as well as the motors. For both system configurations, the output contactors for the master drive and backup drive will be tied to the Run relay output on the respective drives. This will set the drive software as the interlock. hen the master drive is running and sees a fault, the motor interlock contactor will drop out. hen this occurs, the system will check if the backup drive is able to run the motor. If it is able, the backup drive will close its Run relay thus closing the output contactor. ll main controls, inputs and outputs should be wired to both drives. This will allow either drive to properly operate the system if it becomes the active drive. Further details on the wiring and setup are given in the following sections.

pplication Note P040112EN PowerXL DG1 Redundant Drives pplication Input Circuit reaker (MCP) Drive 1 input contactor/ disconnect Drive 2 input contactor/ disconnect Drive I1+ Drive (ackup) I1+ I1- I1- CM CM Drive 1 Output contactor (M1) ack up drive output contactor (M2) Motor Figure 1: Redundant Drive Configuration with 2 Drives Controlling 1 Motor 2 ETON CORPORTION www.eaton.com

PowerXL DG1 Redundant Drives pplication pplication Note P040112EN Input Circuit reaker (MCP) Drive 1 input contactor/ disconnect Drive 2 input contactor/ disconnect Drive I1+ Drive (ackup) I1+ I1- I1- CM CM Drive 1 Output contactor (M1) ack up drive output contactor (M2) Motor Motor Figure 2: Redundant Drive Configuration with 2 Drives Controlling 2 Motors ETON CORPORTION www.eaton.com 3

pplication Note P040112EN PowerXL DG1 Redundant Drives pplication Sample Control Schemes Figures 3 5 below show basic control scheme layouts for three different types of transducer setups. The figures show the wiring of the analog signals, start commands, and the RS-485 communication bus between each drive. ith this setup, the backup drive will always be capable of becoming the active drive in the event of a drive failure. If Safe Torque Off (STO) is used, the inputs can be run in parallel to each drive or individually. If the backup drive s STO is connected individually from the Master drive and a fault is triggered, it can be sent back to the Master drive to stop the system. This is controlled by the P18.3.6 parameter setting and is explained in the later tables. If multiple motors are used, it would be advised to use Motor interlocks to be sure the motor is OK to run prior to operating. In the case where a single motor is used, the interlock would be disabled or fed back to both drives. hen the motor interlock is used, it will not allow the system to run with a single motor. The last drive in the network should have the RS485 Termination resistor enabled on the control board. This resistor identifies the last device on the communication network. Please see the figures and associated notes on the following pages. 4 ETON CORPORTION www.eaton.com

PowerXL DG1 Redundant Drives pplication pplication Note P040112EN + Output 0-10 transducer Drive I1+ I1- Start CM M1 Drive (ackup) I1+ I1- CM M2 Figure 3: Control scheme with 10 supply and 0-10 transducer For the control scheme in Figure 3, please note the following: The /+ supplies along with Grounds for each drive should be connected together. hen connecting multiple power supplies together, it is advised to use a feedback diode to prevent power supplies back feeding on themselves. The Run commands need to be wired into each drive. Parameter/Setting Main Drive Setting ackup Drive Setting P2.1 I1 Mode 0-10 0-10 P2.2 I1 Signal Range 0-100% 0-100% Jumper RS485 Terminating Resistor ETON CORPORTION www.eaton.com 5

pplication Note P040112EN PowerXL DG1 Redundant Drives pplication + Output 4-20m transducer Drive I2+ I2- Start CM M1 Drive (ackup) I2+ I2- CM M2 Figure 4: Control Scheme with 10 supply and 4-20m Transducer For the control scheme in Figure 4, please note the following: The /+ supplies along with Grounds for each drive should be connected. hen connecting multiple power supplies together, it is advised to use a feedback diode to prevent power supplies back feeding on themselves. The Run commands need to be wired into each drive. Parameter/Setting Main Drive Setting ackup Drive Setting P2.11 I2 Mode 0-20m 0-20m P2.12 I2 Signal Range 20-100% 20-100% Jumper RS485 Terminating Resistor 6 ETON CORPORTION www.eaton.com

PowerXL DG1 Redundant Drives pplication pplication Note P040112EN Ext. Supply + - + Output 4-20m transducer Drive I2+ I2- Start CM M1 Drive (ackup) I2+ I2- CM M2 Figure 5: Control Scheme with External Supply and a 4-20m transducer For the control scheme in Figure 5, please note the following: The + supplies along with Grounds for each drive should be connected. hen connecting multiple power supplies together, it is advised to use a feedback diode to prevent power supplies back feeding on themselves. The Run commands need to be wired into each drive. Parameter First Drive Setting ackup/last Drive Setting P2.11 I2 Mode 0-20m 0-20m P2.12 I2 Signal Range 20-100% 20-100% Jumper RS485 Terminating Resistor ETON CORPORTION www.eaton.com 7

pplication Note P040112EN PowerXL DG1 Redundant Drives pplication Parameters The table below shows the setup parameters. This menu is visible in both Single and Multi drive modes. Panel Code Parameter Default Range Modbus ID Description P18.3.1 Multi-pump mode 0 0-1 2279 0 = Disable 1 = Single Drive 2 = Multi Drive (multi-follower) P18.3.2 Drive ID 0 0-5 2278 Each drive in multi drive system has to have a unique, and non-zero number. If a drive has a zero ID, it will be regard as isolated single drive. nd for multi drive system, the lower number drive has higher priority to compete for master. P18.3.3 Number of Motors 1 0-5 342 Total number of motors/pumps connected to this drive in single drive mode. hen in multi-drive, this limits the amount of active drives running at a time. P18.3.4 Regulation Source 0 0-1 2284 0 = Network 1 = Feedback For drives that have been connected with both start/stop signal and PID feedback can be set as Feedback, so they will have ability to be master. P18.3.5 Recovery Method 0 0-1 2285 0 = utomatic 1 = Stop This parameter is for slaves when multi drive system lost master, slave drive can continue run if it is set to be utomatic, however the slave drive will stop immediately if it is set to be Stop. P18.3.6 Callback Source 0 0-1 2286 0 = No ction 1 = Safety Torque Off Sometimes some information needs to be called back from slave to master and affect the whole system; if the slave drive has a callback source as STO, when it suffers STO fault, master drive will answer this callback and shut down the whole system. P18.3.7 dd/remove Pump Rule 0 0-1 2311 0 = Drive ID 1 = Run Time In default, MPFC system will add/remove pump according to their drive ID, from small to large; and the order can also depend on each slave drive s running time: add the drive has shortest running time and remove the drive has longest running time first. P18.3.8 PID andwidth 343 The same as Single Drive mode P18.3.9 Staging Frequency P1.2 P1.1-400 2315 Master drive can only add pump when output frequency is over staging frequency and feedback is out of bandwidth. P18.3.10 De-Staging Frequency P1.1 0 - P1.2 2316 Master drive can only reduce pump when output frequency is below de-staging frequency and feedback is out of bandwidth. P18.3.11 dd/remove Delay 344 The same as Single Drive mode P18.3.12 Interlock Enable 350 The same as Single Drive mode ut in Multi Drive mode, system only detect Interlock 1 P18.3.13 Include Freq Converter 346 Not available for Multi Drive mode P18.3.14 uto-change Enable 345 Not available for Multi Drive mode P18.3.15 uto-change Interval 347 Not available for Multi Drive mode P18.3.16 uto-change Freq 349 Not available for Multi Drive mode Limit P18.3.17 uto-change Motor 348 Not available for Multi Drive mode Limit P18.3.18 Run Time Enable 0 0-1 2280 The run time counter will start counting only if this parameter is enabled. P18.3.19 Run Time Limit 0.0 0.0-300000. 0 2281 If drive run time is over this limit, its network status will be Need lternation. Limit equals 0 means run time counter disabled. P18.3.20 Run Time Reset 0 0-1 2283 One-time parameter, when to 1 it will clear the run time counter. 8 ETON CORPORTION www.eaton.com

PowerXL DG1 Redundant Drives pplication pplication Note P040112EN P18.3.21 Damper Start 483 Not available for Multi Drive mode P18.3.22 Damper Time Out 484 Not available for Multi Drive mode P18.3.23 Damper Delay 485 Not available for Multi Drive mode The table below shows the status parameters. This menu is visible only in multi drive mode. Panel Parameter Default Range Modbus Description Code ID P18.1.1.x Operation Mode 0 0-2 0 = Offline (For single drive mode or slave drive which has lost master in multi drive mode) 1 = Slave Drive (Operate as an auxiliary drive in multi drive mode) 1 = Master (Operate as the regulating drive of the Multi drive system) P18.1.2.x Multi-pump Status 5 0-5 0 = Stopped (For master or single drive which is stopped) 1 = Sleep (For master or single drive which is asleep) 2 = Regulating (For master or single drive which is running) 3 = ait for CMD (For slave drive which is stopped) 4 = Following (For slave drive which is running) 5 = nknown (Status for disconnected drives showing on other drives menu) P18.1.3.x Network Status 0 0-4 0 = Disconnected (For disconnected slave drive or single drive) 1 = Fault (For drives that suffer fault) 2 = Pump Lost (For drives that lose interlock signal) 3 = Need lternation (For drives that run time is over limit) 4 = No Error The table below shows the measurement parameters. This menu is visible only for Master drives. Panel Parameter Default Range Modbus Description Code ID P18.2.1.x Latest Fault Code These measurement parameters of all drives within multi P18.2.2.x Output Frequency drive system can be seen from master drive s menu. P18.2.3.x Motor oltage P18.2.4.x Motor Current P18.2.5.x Motor Torque P18.2.6.x Motor Power P18.2.7.x Motor Speed P18.2.8.x Run Time ETON CORPORTION www.eaton.com 9

pplication Note P040112EN PowerXL DG1 Redundant Drives pplication Installation Settings The steps below detail the process for setting up the redundant drive system. 1. Make all hardwire connections between the two drives. a. Terminal / for RS485 connect the two drives together. b. Power Supply connect the two drives with feedback diodes if using both drives supplies (with ext. supply this is not required) to prevent back feeding on individual Master devices. c. connect the Control terminals on both drives to keep a common control level. d. Digital Inputs connect any desired Digital inputs to both drives. e. nalog Inputs connect analog feedback and set point values to both drives. f. Safe Torque Off (STO) connect to the STO terminals on both drives in series. 2. On the keypad or PC tool, set both drives to the Multi-Pump application (P21.1.2 pplication). 3. Go through the Start p wizard to set up the motor parameters and control places. (Either Local or Remote Reference parameters should be set for PID Control 1 to follow PID control loop operation.) 4. Set the aud rate (P20.2.3) and communication mode (P20.2.1) to the desired com speed and Modbus-RT. The Slave address (P20.2.2) for each drive should be different. 5. Set up any additional control functions required. 6. Set Drive ID s (P18.3.2) to different ID s. 7. Set the maximum amount of motors (P18.3.3) to 1 so that only one drive will be active at a time. oth drives should have the Start/Stop signal and PID feedback connected to them and the PID Feedback connection regulation source (P18.3.4) set to PID Controller 1. 8. Select the functions for the other Multi-drive functions if the defaults are not desired. ith the default values, the system can safely operate. The table on the following page shows the default values. a. Recovery Method (P18.3.5) b. Callback Source (P18.3.6) c. dd/remove Drive Selection (P18.3.7) d. PID andwidth (P18.3.8) e. Interlock (P18.3.12) 9. Once set, copy the parameters to the keypad (P21.1.4) to back up the parameters for both drives. 10. ith the drives connected, the Master drive should see the additional drive and the setup is done. The system can now be started. Note: hen the keypad is used as the set point source, changes are not communicated to other drive. If the set point is changed on one drive, it is required to manually change the set point on the other drive. This will allow the system to keep the desired set point when it switches to the backup drive. 10 ETON CORPORTION www.eaton.com

PowerXL DG1 Redundant Drives pplication pplication Note P040112EN Parameter Parameter Name Drive Setting (oth Drives) P21.1.2 pplication Multi-Pump P20.2.1 Communication Mode Modbus RT P20.2.2 Slave ddress aries P20.2.3 aud Rate 9600 P1.11 Remote Control Place I/O terminal P1.14 Remote Reference PID Control 1 P3.37 Motor Interlock 1 aries single motor not used, multiple motors set up ID P10.11 PID1 Keypad Set point 1 aries P10.14 PID1 Set point Source Keypad or I or Fieldbus P10.32 Feedback Source 1 I2 or I2 P18.3.2 Drive ID aries P18.3.3 Number of Motors 1 P18.3.4 Regulation Source PID Controller 1 P18.3.5 Recovery Method utomatic P18.3.6 Callback Source No ction if STO s are in wired in parallel, Safety Torque Off if the STO s are individually wired P18.3.7 dd/remove Pump Rule Drive ID P18.3.8 PID andwidth 10 P18.3.12 Interlock Enabled Disabled with single motor, Enable with multiple motors P18.3.13 Include Frequency Converter Enabled ETON CORPORTION www.eaton.com 11

pplication Note P040112EN PowerXL DG1 Redundant Drives pplication pplication Specifics Master Handover hen a drive is setup as the Master drive, it will maintain the master functionality as long as it does not meet the following status. 1. Fault occurs except for STO. (If Master drive has STO fault, the whole system will be shut down and it will remain in the Master position). 2. The interlock signal is lost (when using the interlock function). 3. The regulation source (P18.3.4) changes from feedback to network. In the event the Master drive meets one of the criteria above, the system will switch to the backup drive if the following conditions exist: 1. The drive is within the Multi-Pump and Fan control network and communication is OK. 2. Regulation source (P18.3.4) is set at feedback. 3. No active faults and interlock signal is present (if enabled). Master Lost If there is a communication loss between the Master and backup drive for over 5 seconds, there will be a new Master generated from the backup master. If neither Master is able to run, the system will stay stopped. Slave Callback If using the Safe Torque Off feature and the inputs are not wired in series between the two drives, it is possible to shut down both drives when a Safe Torque Fault occurs to the backup drive. y setting parameter P18.3.6 Callback Source Setting to Safety Torque Off, the main drive will shut down if an STO fault is seen by the backup drive. Fire Mode If using Fire Mode via a digital input, it is necessary to wire the input into both drives and set the Fire Mode frequency in both drives. This will allow the active drive (Master or backup) to begin operating at the Fire Mode frequency when activated. Keypad Stop button y default, the keypad is always active for stopping the drive based off the Keypad Stop (P7.5) parameter. hen the Master drive keypad Stop button is pressed, the operation will shut down the whole system regardless of where the control source is coming from. If a backup drive receives the keypad Stop operation, it will not affect the Master drive. 12 ETON CORPORTION www.eaton.com

pplication Note P040112EN PowerXL DG1 Redundant Drives pplication dditional Help In the S or Canada: please contact the Technical Resource Center at 1-877-ETN-CRE or 1-877-386-2273 option 2, option 6. ll other supporting documentation is located on the Eaton web site at www.eaton.com/drives Eaton 1000 Eaton oulevard Cleveland, OH 44122 S Eaton.com 2014 Eaton ll Rights Reserved Printed in S Publication No. P040112EN May 2015 Eaton is a registered trademark of Eaton Corporation. ll other trademarks are property of their respective owners