RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock (for voltages > 00 V, a dead interval of 0 ms on reversing must be taken into account) Sizes S00 to S As components for customer assembly. There is also a range of accessories (auxiliary switch blocks, surge suppressors, etc.) that must be ordered separately. For overload relays for motor protection, see "SIRIUS Overload Relays". The RA1 contactor assemblies have screw connections and are suitable for screwing or snapping onto mm standard mounting rails. Complete units The fully wired reversing contactor assemblies are suitable for use in any climate. They are finger-safe according to EN 027. The contactor assemblies consist of 2 with the same power, with one NC contact in the basic unit. The are mechanically and electrically interlocked (NC contact interlock). For motor protection, either RU11 overload relays for direct mounting or individual mounting or thermistor motor protection tripping units must be ordered separately. Components for customer assembly Installation kits for all sizes are available for customer assembly of reversing contactor assemblies. Contactors, overload relays, the mechanical interlock (as of size S0) and for momentary-contact operation auxiliary switch blocks for latching must be ordered separately. Rated data AC-2 and AC- for AC 0 Hz 00 V Rating kw Size Contactor Mechanical current I e interlock 1) A 1) Can be mounted onto the. 2) Laterally mountable with one auxiliary contact. ) Laterally mountable without auxiliary contact. ) Interlock can only be ordered with installation kit. ) Installation kit contains: mechanical interlock; connecting clips for 2 ; wiring connectors on the top and bottom. Mechanical interlock 2) Mechanical Installation kit Fully wired and tested interlock ) contactor assemblies 7 S00 RT10 1 -- ) -- -- RA19 1-2A ) RA1 1-8XB0-1.. 9 RT10 1 RA1 1-8XB0-1... RT10 17 RA1 17-8XB0-1... S0 RT10 2 RA19 2-1A RA19 2-2B -- RA19 2-2A ) RA1 2-8XB0-1.. 7. 17 RT10 2 RA1 2-8XB0-1.. 1 RT10 2 RA1 2-8XB0-1.. 1 2 S2 RT10 RA19 2-1A RA19 2-2B -- RA19-2A 7) RA1-8XB0-1.. 18. 0 RT10 RA1-8XB0-1.. 22 0 RT10 RA1-8XB0-1.. 0 S RT10 RA19 2-1A RA19 2-2B -- RA19-2A 7) RA1-8XB0-1.. 7 80 RT10 RA1-8XB0-1.. 9 RT10 RA1-8XB0-1.. 11 S RT10 -- -- RA19-2A RA19-2A 8) -- 7 10 RT10 90 18 RT10 110 22 S10 RT10 -- -- RA19-2A RA19-2A 8) -- 2 RT10 10 00 RT10 200 00 S RT10 7 -- -- RA19-2A RA19 7-2A 8) -- 20 00 RT10 7 -- -- ) Installation kit contains: wiring connectors on the top and bottom. 7) Installation kit contains: 2 connecting clips for ; wiring connectors on the top and bottom. 8) Installation kit contains: wiring module on the top and bottom. /8 Siemens LV 1 200
RA1, RA Contactor Assemblies RA1 complete units,... kw Selection and ordering data Size S00. kw Rated data AC-2 and AC- current I e Ratings of induction motors at 0 Hz and Rated control DT supply voltage U 1) s Fully wired and tested contactor assemblies 2) Price 00 V 20 V 00 V 00 V 90 V A kw kw kw kw V kg AC operation, 0/0 Hz 7 2.2. 2 AC A RA1 1-8XB0-1AB0 1 1 unit 101 0.29 110 AC A RA1 1-8XB0-1AF0 1 1 unit 101 0.0 20 AC } RA1 1-8XB0-1AP0 1 1 unit 101 0.27 9.. 2 AC A RA1 1-8XB0-1AB0 1 1 unit 101 0.29 110 AC A RA1 1-8XB0-1AF0 1 1 unit 101 0.28 20 AC } RA1 1-8XB0-1AP0 1 1 unit 101 0.2... 2 AC A RA1 17-8XB0-1AB0 1 1 unit 101 0.0 110 AC A RA1 17-8XB0-1AF0 1 1 unit 101 0.2 20 AC } RA1 17-8XB0-1AP0 1 1 unit 101 0.0 DC operation 1) Coil operating range at 0 Hz: 0.8... 1.1 x U s ; at 0 Hz: 0.8... 1.1 x U s. 7 2.2. 2 DC } RA1 1-8XB0-1BB 1 1 unit 101 0.8 9.. 2 DC } RA1 1-8XB0-1BB 1 1 unit 101 0.7 2) The integrated in the contactor assemblies have no unassigned auxiliary contacts. Mountable accessories (to be ordered separately): The fully wired and tested contactor assembly includes the following components: 1 1 2 NSB009 1 1 Accessories Page Individual parts Page K1 K2 1 1 Solder pin adapters (auxiliary switch block according to EN 000 must be used) Surge suppressors RT19 1-KA1 RH19 11-1... RT19 1-1... /2 /110 /119, /0 1) RT10 1 with one NC contact in the basic unit are required for the electrical interlock. Contactors, kw Contactors, kw Contactors,. kw Installation kit The installation kit contains: RT10 1 RT10 1 RT10 17 RA19 1-2A RT10 1 RT10 1 RT10 17 Mechanical interlock 2 connecting clips for 2 Wiring connectors on the top and bottom for connecting the main conducting paths, electrical interlock included 1), interruptible (NC contact interlock) / / / / Siemens LV 1 200 /9
RA1, RA Contactor Assemblies RA1 complete units,... kw Size S0 11 kw Rated data AC-2 and AC- current I e Ratings of induction motors at 0 Hz and 1) Coil operating range at 0 Hz: 0.8... 1.1 x U s ; at 0 Hz: 0.8... 1.1 x U s. Rated control DT supply voltage 1) U s Fully wired and tested contactor assemblies Price 00 V 20 V 00 V 00 V 90 V A kw kw kw kw V kg AC operation, 0/0 Hz. 7. 7. 2 AC A RA1 2-8XB0-1AC2 1 1 unit 101 0.7 110 AC A RA1 2-8XB0-1AG2 1 1 unit 101 0.7 20 AC } RA1 2-8XB0-1AL2 1 1 unit 101 0.777 17 7. 10 1 AC A RA1 2-8XB0-1AC2 1 1 unit 101 0.70 110 AC A RA1 2-8XB0-1AG2 1 1 unit 101 0.7 20 AC } RA1 2-8XB0-1AL2 1 1 unit 101 0.77 2. 11 11 1 AC A RA1 2-8XB0-1AC2 1 1 unit 101 0.7 110 AC A RA1 2-8XB0-1AG2 1 1 unit 101 0.70 20 AC A RA1 2-8XB0-1AL2 1 1 unit 101 0.77 DC operation. 7. 7. 2 DC } RA1 2-8XB0-1BB 1 1 unit 101 1.22 17 7. 10 1 DC A RA1 2-8XB0-1BB 1 1 unit 101 1.222 2. 11 11 1 DC A RA1 2-8XB0-1BB 1 1 unit 101 1.229 Mountable accessories (to be ordered separately): The fully wired and tested contactor assembly includes the following components: 1 1 1 2 NSB000 The connecting leads are not shown. Accessories Page Individual parts Page K1 K2 1 1 Surge suppressors RA19 2-1A RH19 21-1CA.. RH19 21-1EA.. RT19 2-1... / /1 /1 /119 Contactors,. kw Contactors, 7. kw Contactors, 11 kw RT10 2 RT10 2 RT10 2 RT10 2 RT10 2 RT10 2 / / / Installation kit RA19 2-2B RA19 2-2A / / The installation kit contains wiring connectors on the top and bottom (they also form the mechanical connection between the ). /0 Siemens LV 1 200
RA1, RA Contactor Assemblies RA1 complete units,... kw Size S2 22 kw Rated data AC-2 and AC- current I e Ratings of induction motors at 0 Hz and 1) Coil operating range at 0 Hz: 0.8... 1.1 x U s ; at 0 Hz: 0.8... 1.1 x U s. Rated control DT supply voltage 1) U s Fully wired and tested contactor assemblies Price 00 V 20 V 00 V 00 V 90 V A kw kw kw kw V kg AC operation, 0/0 Hz 2 7. 1 18. 18. 2 AC A RA1-8XB0-1AC2 1 1 unit 10.2 110 AC A RA1-8XB0-1AG2 1 1 unit 10.2 20 AC A RA1-8XB0-1AL2 1 1 unit 10.220 0 11 18. 22 22 2 AC A RA1-8XB0-1AC2 1 1 unit 10.1 110 AC A RA1-8XB0-1AG2 1 1 unit 10.20 20 AC A RA1-8XB0-1AL2 1 1 unit 10.00 0 1 22 0 22 2 AC B RA1-8XB0-1AC2 1 1 unit 10.0 110 AC B RA1-8XB0-1AG2 1 1 unit 10.1 20 AC A RA1-8XB0-1AL2 1 1 unit 10.290 DC operation 2 7. 1 18. 18. 2 DC A RA1-8XB0-1BB 1 1 unit 101.0 0 11 18. 22 22 2 DC A RA1-8XB0-1BB 1 1 unit 101. 0 1 22 0 22 2 DC A RA1-8XB0-1BB 1 1 unit 101. Mountable accessories (to be ordered separately): The fully wired and tested contactor assembly includes the following components: 1 1 2 1 NSB001 The connecting leads are not shown. Accessories Page Individual parts Page K1 K2 1 1 Surge suppressors RA19 2-1A RH19 21-1CA.. RH19 21-1EA.. RT19 2-1... RT19-1... / /1 /1 /119 Contactors, 1 kw Contactors, 18. kw Contactors, 22 kw Installation kit The installation kit contains: RT10 RT10 RT10 RA19 2-2B RA19-2A RT10 RT10 RT10 /1 /1 /1 / / 2 connecting clips for 2 with a clearance of 10 mm Wiring connectors on the top and bottom for connecting the main conducting paths Siemens LV 1 200 /1
RA1, RA Contactor Assemblies RA1 complete units,... kw Size S kw Rated data AC-2 and AC- current I e Ratings of induction motors at 0 Hz and 1) Coil operating range at 0 Hz: 0.8... 1.1 x U s ; at 0 Hz: 0.8... 1.1 x U s. Rated control DT supply voltage 1) U s Fully wired and tested contactor assemblies Price 00 V 20 V 00 V 00 V 90 V A kw kw kw kw V kg AC operation at 0/0 Hz 18. 0 7 2 AC B RA1-8XB0-1AC2 1 1 unit 101.22 110 AC B RA1-8XB0-1AG2 1 1 unit 101.20 20 AC B RA1-8XB0-1AL2 1 1 unit 101.221 80 22 7 2 AC B RA1-8XB0-1AC2 1 1 unit 101.2 110 AC B RA1-8XB0-1AG2 1 1 unit 101.00 20 AC B RA1-8XB0-1AL2 1 1 unit 101.00 9 22 2 AC B RA1-8XB0-1AC2 1 1 unit 101. 110 AC B RA1-8XB0-1AG2 1 1 unit 101.00 20 AC B RA1-8XB0-1AL2 1 1 unit 101.70 DC operation 18. 0 7 2 DC B RA1-8XB0-1BB 1 1 unit 101.80 80 22 7 2 DC B RA1-8XB0-1BB 1 1 unit 101.0 9 22 2 DC B RA1-8XB0-1BB 1 1 unit 101.71 Mountable accessories (to be ordered separately): The fully wired and tested contactor assembly includes the following components: 1 1 2 1 NSB002 The connecting leads are not shown. Accessories Page Individual parts Page K1 K2 1 1 Surge suppressors RA19 2-1A RH19 21-1CA.. RH19 21-1EA.. RT19 2-1... RT19-1... / /1 /1 /119 Contactors, 0 kw Contactors, 7 kw Contactors, kw Installation kit The installation kit contains: RT10 RT10 RT10 RA19 2-2B RA19-2A RT10 RT10 RT10 /18 /18 /18 / / 2 connecting clips for 2 with a clearance of 10 mm Wiring connectors on the top and bottom for connecting the main conducting paths /2 Siemens LV 1 200
RA1, RA Contactor Assemblies Components for customer assembly Selection and ordering data For Type Mechanical interlocks RA19 2-1A mounted onto 2 RA19-2A RA19-2C Coil repeat terminals RA19 2-B Base plates RT10 2 RT10 RT10 RT1 2 RT1 RT1 RT10 2 RT10 RT10 RT1 2 RT1. RT1. 7 RT10.-A with RT10 RT10 RT10 1) Can also be used for -pole with sizes S2 and S. 2) Can also be used for size S0 -pole. Size Version DT Price S0 S2 S S0 S2 S S0 S S10 S S with S For mounting 1) Each with one auxiliary contact (1 NC contact) per contactor (can only be used to connect which are not more than 1 size larger or smaller. The mounting depth of the smaller contactor has to be adapted.) For mounting to the 2) To with sizes S0 to S (for of the same size) Note: Size S0: Wiring connectors must be mounted first Sizes S2 and S: Use RA19 2-2C mechanical connectors For mounting Without auxiliary contacts; size S, S10 and S can be interlocked with each other as required; no adaptation of mounting depth is necessary. Contactor clearance 10 mm. kg } RA19 2-2B 1 1 unit 101 0.00 } RA19 2-1A 1 1 unit 101 0.02 } RA19-2A 1 1 unit 101 0.0 Adapter, ly mountable, for mechanical interlocking of contactor S (only for AC operation) with contactor S using RA19-2A locking device (must be ordered separately) incl. connecting clips A RA19-2C 1 1 unit 101 0.00 S2, S For the coil connectors A1 and A2 for reversing starters (contactor sizes S2 and S). 2 x A1 and 1 x A2 required per assembly. (1 set contains 10 x A1 and x A2) B RA19 2-B 1 1 set 101 0.082 RT10 S For customer assembly of B RA19 2-2A 1 1 unit 101 1.29 RT1. S10 reversing contactor B RA19 2-2A 1 1 unit 10.091 RT1. 7 S assemblies B RA19 72-2A 1 1 unit 10.22 Siemens LV 1 200 /
RA1, RA Contactor Assemblies Components for customer assembly For Size Version DT Price kg Type Installation kits for making -pole contactor assemblies RT10 1 S00 The installation kit contains: } RA19 1-2A 1 1 set 101 0.01 mechanical interlock 2 connecting clips for 2 RA19 1-2A wiring connectors on the top and bottom RT10 2 S0 The installation kit contains: wiring connectors on the top and bottom } RA19 2-2A 1 1 set 101 0.02 RA19 2-2A RT10 S2 The installation kit contains: 2 connecting clips for 2 wiring connectors on the top and bottom } RA19-2A 1 1 set 101 0.2 RA19-2A RT10 S The installation kit contains: 2 connecting clips for 2 wiring connectors on the top and bottom } RA19-2A 1 1 set 101 0.29 RA19-2A RT10 S The installation kit contains: A RA19-2A 1 1 set 101 1.29 RT1. S10 wiring connectors on the A RA19-2A 1 1 set 10.19 RT1. 7 S top and bottom A RA19 7-2A 1 1 set 101.00 / Siemens LV 1 200
RA1, RA Contactor Assemblies Components for customer assembly Wiring connectors Size For Contactor clearance Version DT Price Type mm kg RT10 1 S00-S00 0 Top (in-phase) } RA19 1-D 1 unit 101 0.011 Bottom (phase reversal) } RA19 1-E 1 unit 101 0.0 RT10 2 S0-S0 0 Top (in-phase) } RA19 2-D 1 unit 101 0.021 and and Bottom (phase } RA19 2-E 1 unit 101 0.019 S0-S0 10 reversal) RT10 S2-S2 10 Top (in-phase) } RA19 -D 1 1 unit 101 0.0 Bottom (phase } RA19 -E 1 1 unit 101 0.0 reversal) RT10 S-S 10 Top (in-phase) } RA19 -D 1 1 unit 101 0.17 Bottom (phase } RA19 -E 1 1 unit 101 0.17 reversal) RT10 S-S 10 Top (in-phase) A RA19 -D 1 1 set 101 0.1 RT10 S10-S10 10 Top (phase reversal) B RA19 -D 1 1 set 101 1.2 Size For Contactor clearance Interlocking Version DT Price Type mm kg Mechanical connectors 1 pack = 10 sets for 10 assemblies RT1. 1 1) S00-S00 0 Laterally For and mountable -pole } RA19-2H 1 10 sets 101 0.001 RA19-2H RA19 22-2C RT1. 2 S0-S0 0 Mountable 10 2) on RT1. RT1. S2-S2 S-S Laterally mountable 0 Mountable on For and -pole For -pole } RA19 22-2C 1 10 sets 101 0.02 } RT19 22-2D 1 10 sets 101 0.110 } RA19 2-2C 1 10 sets 101 0.001 RA19 2-2C RT1. RT1. RT1. S2-S2 S-S S-S 10 Laterally For -pole mountable } RA19 2-2D 1 10 sets 101 0.00 RA19 2-2D RT1. S2-S2 10 Laterally For -pole mountable } RA19 2-2G 1 10 sets 101 0.007 RA19 2-2G RT1. S-S 10 Laterally For -pole mountable } RA19 2-2G 1 10 sets 101 0.008 RA19 2-2G 1) This pack contains 10 additional interlocks. 2) The connector function can be fulfilled with the wiring connectors for size S0, a contactor clearance of 10 mm and a interlock. Siemens LV 1 200 /