Table of Contents CaseIH Combines...1

Similar documents
GS2 Third Party Controller Harness Kit

Case AFS Pro 300, 600, 700 Display Kit (Self-Propelled) Installation Manual 54VT-PRO-SP01

Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case & NH ISObus Ready) Display Kit Installation Manual 54VT-PRO-PT01

Trimble FMX/FM100 - with Hydraulic Steer - Case IH Factory Install Installation & Configuration Guide for Harness :

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

ISOBUS Working Set. One or more ISOBUS modules that control an implement s functionality. Main module is called the Working Set Master (WSM).

education and advancement of the marine electronics industry and to waypoint, present Lat/Long, and a binary status byte.

INSIGHT SYSTEM PIN-OUT GUIDE Draft Rev. August 2004

SMS - Known Issues. Jump to section below: SMS v18.0 Known Issues. SMS - Known Issues 1

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19

DirectCommand Installation DirectCommand Complete Wiring Harness

Table of Contents. GPS Legacy Products...1 Configuring GPS 6500 and 6000 For Legacy Displays...1

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx

Survey. Chamber Chamber. black (2m) 10 pin 3 tubes. LI-8100A Analyzer Control Unit Chamber black (2m) 12 pin 2 tubes.

Connecting a Cisco Reader Module

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

INTMOD485-LH Protocol Converter

Ag Leader Technology. DirectCommand Installation Rogator 900/1100/1300 Sprayers

with the Yield Monitoring System Quick Reference Card

Precision Farming System PF3000 Cotton Yield Monitor Operators Manual

Installation Instructions for: Channel Thermocouple Amplifier

Mobileye EyeCAN (with CAN sniffer cable) User Guide

Field Update Guide. for Raven Viper Pro

Hello Angles... A First Use Guide to the VS Product Series: RS232 Interface with LD Standard Communication Protocol & Analogue 4-20mA Output Signals.

OPERATOR S MANUAL VM-4100

Unity Control Circuit Board As of

Analog Input and Output Options for Syringe Pumps

INDUSTRIAL POE SWITCH

Mounting DIGITAL DISPLAY

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

Hydronix Moisture Sensor Electrical Installation Guide

Instruction Manual. P/N AQ1 Data Logger

Older Compaq UPS Family - Identifying Serial Communication Cables

Precision Farming System Operators Manual

3950 NW 120 th Ave, Coral Springs, FL TEL FAX MFT F-CAM. Force Front Camera Module NTV-KIT831 BHM 07/31/18 NTV-DOC298

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Raven Adapter Harness

INSTALLATION INSTRUCTIONS

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

Dearborn Protocol Adapter (DPA) and PLC TestCon Pinouts and Industry Connectors Reference Guide Including the J1939 Type-2 Connector

W205-RVC NTV-KIT580. Overview

New Eagle Data Logger

Supply Voltage V dc Supply is fully isolated internally, and protected against transients. Internal power modules are CE certified.

2. Hardware Connectivity

Domain 3000 Back Panel

Bosch LSU4 Wide Band UEGO Controller

InSight Single Implement

Industrial Power Supply Connectors

Addendum for 125B Bushealth Measurements

LTI TruSense S200 S210 Quick Guide

Note: Indented items indicate parts included in an assembly listed above

Parrot MULTICAN for Mini cars (part 2)

Harvest Setup for CNH controllers

Target cell RTD-set. RTD label. Epics RTD notation. Red or Golden. CPC plug slot. Old notation from 1 to 15** RTD 4, B4, R2.

TOUCH TRACKER with Quad Splitter

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

Printer Interface (6370) Setup. Replaces discontinued Printer Interface (4370)

Easy Arc Integration into a Simatic S7-300 Process Control System

WIRING FOR MXL PRO- 05

Parrot MULTICOMM For Mitsubishi steering wheel

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

Supported Vehicle Installations

Driver/Controller Development Assistance Package For IDEX Health & Science TitanHT TM Driver Board

GSV-1A4 M12/2 M12/2. Highlights

DirectCommand Installation RoGator Model Year Ag Leader Technology

Tank Fluid Monitor 905-D6 WITS OPTION COMMUNICATION BOARD MANUAL IMPORTANT OPERATOR INFORMATION

Connecting and Calibrating a Load Cell with V-Link

Tile Plow Installation Gold Digger

DWG DESCRIPTION IRVINE, CALIFORNIA MANUAL, INSTALL, HID MIFARE READER REVISIONS INITIAL RELEASE PER EO #E6055-7

More Precision. colorsensor // Color Sensors, LED Analyzers

Trust Truesight 2 - True row guidance for high accuracy row-crop autosteer control

Neets Control QueBec P/N#: P/N#: User Manual

Note: Indented items indicate parts included in an assembly listed above

connecdim Gateway G1 Ethernet TCP/IP to DALI

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

DNP3 Protocol (Serial)

MicroHAWK ID-20 / ID-30 / ID-40

Tile Plow Installation O Connell

Ink-Dot Series II Driver

EMC 10/4 "CE" Mechanical Upgrade Procedure

ATT2 Installation Guide for PQube 3

Jaguar F-TYPE CAM Dual Camera interface for select 14+ Jaguar vehicles NTV-KIT589

Digital Dash I/O Adapter Configuration

INSTALLATION AND OPERATING INSTRUCTIONS FOR. Serial Control Board SCB-100

Quick Installation Guide

Parrot MULTICOMM For FORD steering wheel

Upgrade Kit for the 4300 Remote BAC About This Document Using This Document Note Caution Inspecting Shipment

DirectCommand Installation 5 Channel Spreader Control Module Technology

type44legacy Manual VERIPOS

Bluetooth to Serial Converter TOP FRONT. Click 421

VM VM

FEB 2017 Rev F. Verify that all cable assemblies are in good condition.

Ag Leader Technology. DirectCommand Installation Miller Nitro 5000 & 6000 ISO Kit

C.O.D-F50. Ford OEM 360 Surround-View Camera Controller NTV-KIT899 BHM 02/01/19 NTV-DOC334

MODEL A-30 ALTITUDE DIGITIZER OPERATION MANUAL INSTALLATION MANUAL

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

Quick Reference Guide For

Transcription:

Table of Contents CaseIH Combines...1 CaseIH 2188 Combine Yield Monitor Kit...1 Q: My Combine has a factory yield monitor in it, can I remove it when I install a Ag Leader System?...2 How To Hook up a Case AFS Moisture Sensor to Ag Leader Moisture Module PN 4001538...3 How to Hook up an Ag Leader GPS receiver to a Case IH Pro600...5 CNH Moisture Adapter Cables...8 How to Hook up an Ag Leader GPS receiver to a Case IH Pro700...9 Ground Speed on 2016+ x140 Series Case Combines...12

CaseIH Combines Grain yield monitoring articles related to CaseIH combine harvesters CaseIH 2188 Combine Yield Monitor Kit Click the desired link from the list of reference documents for this model combine: Ag Leader Integra/Versa/EDGE/InSight - 2005800 CAN Combine Installation Instructions - Grain PF/YM Series - 2005200-3 Combine Installation Instructions PF/YM Series - Initial Calibration Sheet South American - Initial Calibration Sheet CaseIH Combines 1

Q: My Combine has a factory yield monitor in it, can I remove it when I install a Ag Leader System? Question: My Combine has a OEM Monitor in it from the factory, can I remove it when I install a Ag Leader System? Answer: As long as the OEM Monitor does not do any of the combine functions (Rotor Speed, Engine Diag, ect..) Example: Case 8010 combine with a Case IH Pro 600 display, the Pro 600 does all the combine functions so we cannot completely remove the OEM monitor. Q: My Combine has a factory yield monitor in it, can I remove it when I install a Ag Leader System?2

How To Hook up a Case AFS Moisture Sensor to Ag Leader Moisture Module PN 4001538 Setup: The customer will remove the cable clamps that secure the OEM Moisture Sensor cable and then double the cable back over so that it reaches our module. Use a PN 4002061-3 to convert the CASE IH 6 pin Duetsch connection to the Ag Leader 8 pin Duetsch moisture module connection. How To Hook up a Case AFS Moisture Sensor to Ag Leader Moisture Module PN 4001538 3

How To Hook up a Case AFS Moisture Sensor to Ag Leader Moisture Module PN 4001538 4

How to Hook up an Ag Leader GPS receiver to a Case IH Pro600 riority="64" SemiHidden="false" UnhideWhenUsed="false" Name="Medium Shading 2 Accent 4" /> How to hook up an Ag Leader GPS receiver to a Case Pro600. Setup: On the bottom of the Pro600 there is a RS232 port. Connect the mobile logging cable PN 4002675-18 (For GPS 1500/1600/2500 receivers) (cig power) or PN 4004176-18 (For GPS 6000/6500 receivers) to the port directly on the bottom of the Pro600. (You will have to go into the pro andriority="64" SemiHidden="false" UnhideWhenUsed="false" Name="Medium Shading 2 Accent 4" /> configure the port. The port is RS232 B and will need to output VTG and GGA at 5hz, 38400 baud.) How to Hook up an Ag Leader GPS receiver to a Case IH Pro600 5

How to Hook up an Ag Leader GPS receiver to a Case IH Pro600 6

How to Hook up an Ag Leader GPS receiver to a Case IH Pro600 7

CNH Moisture Adapter Cables Priority="64" SemiHidden="false" UnhideWhenUsed="false" Name="Medium Shading 2 Accent 4" /> Ag Leader Integra/Versa/EDGE/InSight 1. 2. CNH Adapter Cables Old Style Module Moisture Sensor Adapter for New Holland CR/CX or CaseIH 14xx, 16xx, 21xx, 23xx, 25xx, AFX (Except AFS Black Box sensors) a. PN 4100103: Upgrade CNH EMS to Ag Leader CAN Display (AFX/CR/CX) b. PN 4000362-15: Upgrade CNH EMS to Ag Leader CAN Display (14xx-25xx) New Style Module Moisture Sensor Adapter for New Holland CR/CX or CaseIH 14xx, 16xx, 21xx, 23xx, 25xx, AFX (Except AFS Black Box sensors) a. PN 4002061-3: Upgrade CNH EMS to Ag Leader CAN Display (AFX/CR/CX) b. PN 4002061-15: Upgrade CNH EMS to Ag Leader CAN Display (14xx-25xx) 3. CaseIH YM Ready Combines: 2008-Newer *(Check for 4-Pin Deutsch Connection on Flow Sensor)* YM/PF 1. a. PN 4100334: 7010, 8010, 7120, 8120, 9120 Models b. PN 4100336: 5088, 6088, 7088 Models AFS Black Box (CaseIH Branded YM2000) to Ag Leader YM or PF Series Display (uses all existing sensors) a. PN 2000931: Adapts CaseIH 25 pin cab cable to 25 pin connection on YM/PF display b. PN 3000691: Post Bracket c. PN 2000139: Anchor Bar d. PN 2001304-2: Monitor Bracket Install Kit 1. AFS Universal Display or Universal Display Plus to Ag Leader PF Display 3. a. PN 3001200-1: AFS to PF3000 b. PN 3001200-2: AFS to PF3000Pro c. PN 3001200-3: AFS to PFAdvantage Moisture Sensor Adapter for New Holland CR/CX or CaseIH 14xx, 16xx, 21xx, 23xx, 25xx, AFX (Except AFS Black Box sensors) a. PN 4100104: Upgrade CNH EMS to Ag Leader PF Display (14xx-25xx) b. PN 4100103: Upgrade CNH EMS to Ag Leader PF Display (AFX/CR/CX) CNH Moisture Adapter Cables 8

How to Hook up an Ag Leader GPS receiver to a Case IH Pro700 Overview: This procedure should be applicable to the Pro700/IntelliView equipped CR/AFX combine. Setup: 1.) Find the white 10 pin connector located inside the machine's right hand panel: How to Hook up an Ag Leader GPS receiver to a Case IH Pro700 9

The pin-out for the white connector is as follows: Of which, these pins are of relevance: Function Pin Wire Color Power A Orange Ground B Black TX (transmit) E Blue RX (receive) F Red The pin-out for the GPS 1500, 1600, 2500 Port A Serial Connector is as follows: How to Hook up an Ag Leader GPS receiver to a Case IH Pro700 10

Function Pin Wire Color Power 4 Yellow Ground 5 Black TX (transmit) 3 Green RX (receive) 2 Red 2.) Connect the BLUE wire (pin E) of the machine connector to the GREEN wire (pin 3) of the GPS 1500, 1600, 2500 Port A Serial Connector. 3.) Connect the RED wire (pin F) of the machine connector to the RED wire (pin 2) of the GPS 1500, 1600, 2500 Port A Serial Connector. 4.) Set the display GPS configuration to RS232A: How to Hook up an Ag Leader GPS receiver to a Case IH Pro700 11

Ground Speed on 2016+ x140 Series Case Combines Affected Kit: 4100338 On 2016+ x140 Series Case combines, the ground speed sensor is not supported by the Speed Module. When installing a Harvest kit on this series of machine the ground speed sensor will not be used. GPS is required as a speed source to run yield monitoring with this machine. Content last reviewed on: 8/9/17 Reviewed by: JMD Ground Speed on 2016+ x140 Series Case Combines 12