Residual Current Devices drcm Digital

Similar documents
Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Table of Contents Protective Devices / Components

Combined RCD/MCB Devices FRBmM, 1+N-pole

Add-on Residual Current Protection PBSM MW

Digital Switchgear Communication at Eye Level planb.eu

xeffect - Industrial Switchgear Range

xef xe f f ec f t - Industrial Sw S itc it hgea ge r Range Catalog alo ue 2015

xef xe f f ec f t - Industrial Sw S itc it hgea ge r Range Catalog alo ue 2017

MCB. Elegance and precision engineering in the same breath. Range : upto 63Amps. Available in SP, SPN, DP, TP, TPN & FP version also Designed by HPL

xef xe f f ec f t - Industrial Sw S itc it hgea ge r Range Catalog alo ue 2018

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

W DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Allen-Bradley 1492-RCDA4A40

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Overvoltage Protection Devices

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Product Guide. UL 489 DIN rail miniature circuit breakers

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Surge Protection Devices Ex9UE2

E-STOP relays, safety gate monitors

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

DSE201, DSE201 M Compact design with enhanced protection

VAL-CP-1S-175. Extract from the online catalog. Order No.:

E-STOP relays, safety gate monitors

Datasheet SRB301ST 24V (V.2)

E-STOP relay, safety gate monitor

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

E-STOP relays, safety gate monitors

Section 4 Ground-Fault Protection Devices

Residual Current Protective Devices / Arc Fault Detection Devices

VAL-CP-3S-350. Extract from the online catalog. Order No.:

Datasheet - SRB 402EM-24V

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Safe timer relay/contact expansion modules

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED CONVERTERS 48 V

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

ic60n RCBO 30 ma IEC , IEC , AS/NZS

SITOP in the SIMATIC Design

E-STOP relays, safety gate monitors

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Datasheet - SRB 301LC/B-24V

ENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

MINI-PS AC/10-15DC/8

Contact protection relay

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

QUINT-PS/ 1AC/24DC/ 5

Overvoltage Protection Devices

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

SIMOCODE 3UF Motor Management and Control Devices

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

E-STOP relays, safety gate monitors

Overvoltage Protection Devices

PT 3-PB-ST. Extract from the online catalog. Order No.:

Circuit Breakers Type CTI 25M, CTI 45MB

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

SENTRON SIVACON ALPHA

MODULES FOR SAFETY AND MONITORING

E-STOP relays, safety gate monitors

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Miniature Circuit Breakers for Railway Applications

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Protection Equipment

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Safety relays PNOZsigma

E-STOP relays, safety gate monitors

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

STEP-PS/1AC/24DC/1.75

E-STOP relays, safety gate monitors

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

Contact expander modules

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

Lightning and Surge Arresters

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Transcription:

Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents. Integrated auxiliary contact(s) Local Indication New level of accuracy -> Reduced unwanted tripping Local status indication of residual current through 3 LEDs No monthly test required Comprehensive range of accessories Real contact position indicator Fault current tripping indicator Automatic re-setting possible Transparent designation plate 28

Surge current-proof 3 ka, sensitive to residual pulsating DC, type G/A (ÖVE E 8601) 25/0.03 25/0.3 40/0.03 40/0.3 63/0.03 63/0.3 80/0.03 80/0.3 drcm-25/4/003-g/a+ 120834 1 / 30 drcm-25/4/03-g/a+ 120835 1 / 30 drcm-40/4/003-g/a+ 120836 1 / 30 drcm-40/4/03-g/a+ 120837 1 / 30 drcm-63/4/003-g/a+ 120838 1 / 30 drcm-63/4/03-g/a+ 120839 1 / 30 drcm-80/4/003-g/a+ 120840 1 / 30 drcm-80/4/03-g/a+ 120841 1 / 30 Surge current-proof 3 ka, X-ray application, type R 63/0.03 drcm-63/4/003-r+ 120842 1 / 30 Selective + surge current-proof typ. 5 ka, sensitive to residual pulsating DC, type S/A 40/0.30 63/0.30 80/0.30 drcm-40/4/03-s/a+ 120843 1 / 30 drcm-63/4/03-s/a+ 120844 1 / 30 drcm-80/4/03-s/a+ 120845 1 / 30 Selective + surge current-proof typ. 5 ka, frequency converter-proof, type U 40/0.03 *) 40/0.30 63/0.03 *) 63/0.30 80/0.30 *) Short time delayed + surge current-proof 3 ka drcm-40/4/003-u+ 120850 1 / 30 drcm-40/4/03-u+ 120851 1 / 30 drcm-63/4/003-u+ 120846 1 / 30 drcm-63/4/03-u+ 120847 1 / 30 drcm-80/4/03-u+ 120848 1 / 30 29

Sealing Cover Set Z-RC/AK for PFIM, PFR, PF6, PF7, CFI6, drcm (not to use for PFDM) Type Designation Article No. Units per package 2-pole Z-RC/AK-2TE 285385 10 / 30 Z-RC/AK-4TE 101062 10 / 600 30

- digital Residual current devices Shape compatible with and suitable for standard busbar connection to other devices of the P-series Twin-purpose terminal (lift/open-mouthed) above and below Busbar positioning optionally above or below Free terminal space despite installed busbar Universal tripping signal switch, also suitable for PLS., PKN., ZP-A. can be mounted subsequently Auxiliary switch Z-HK can be mounted subsequently Contact position indicator red - green Tripping indicator white - blue Additional Safety - possibility to seal - possibility to lock in ON and OFF position Delayed types suitable for being used with standard fluorescent tubes with or without electronical ballast (30mA-RCD: 30 units per phase conductor, 100mA-RCD: 90 units per phase conductor) Notes: Depending of the fluorescent lamp ballast manufacturer partly more possible. Symmetrical allocation of the fluorescent lamp ballasts on all phases favourably. Shifting references of the fluorescent lamp ballast manufacturer consider. The device functions irrespective of the position of installation Tripping is line voltage-independent. Consequently, the RCD is suitable for fault current/residual current protection and additional protection within the meaning of the applicable installation rules Mains connection at either side The device can also be used for 3-pole connection: See connection possibilities. The device can also be used for 2-pole connection: See connection possibilities. The test key T must be pressed every year. The system operator must be informed of this obligation and his responsibility in a way that can be proven. The yearly test interval is only valid for residential and similar applications. Under all other conditions (e.g. damply or dusty environment), it's recommended to test in shorter intervals (e.g. monthly). A test is further needed if red and yellow LED are on together. Pressing the test key T serves the only purpose of function testing the residual current device (RCD). This test does not make earthing resistance measurement (R E ), or proper checking of the earth conductor condition redundant, which must be performed separately. Functioning - The green LED becomes active at 0-30% I Δn - The yellow LED becomes active at 30-50% I Δn - The red LED becomes active at >50% I Δn Technical Data 15 Potential-free relay (NO contact, in parallel with the yellow LED, up to 1 A ohmic load / 230 V~) for external prewarning function. Bistabile, means the warning stays on also when the breaker trips, until reset. Type -A: Protects against special forms of residual pulsating DC which have have not been smoothed Type -G: High reliability against unwanted tripping. Compulsory for any circuit where personal injury or damage to property may occur in case of unwanted tripping (ÖVE/ÖNORM E 8001-1 12.1.6). Type -G/A: Additionally protects against special forms of residual pulsating DC which have not been smoothed. Type -R: To aviod unwanted tripping due to X-ray devices. Type -S: Selective residual current device sensitive to AC, type -S. Compulsory for systems with surge arresters downstream of the RCD (ÖVE/ÖNORM E 8001-1 12.1.5). Type -S/A: Additionally protects against special forms of residual pulsating pulsating DC which have not been smoothed. Type -U: Suitable for speed-controlled drives with frequency converters in household, trade, and industry. Unwanted tripping is avoided thanks to a tripping characteristic designed particularly for frequency converters. See also explanation Frequency Converter-Proof RCDs - What for? Application according to ÖVE/ÖNORM E 8001-1 and Decision EN 219 (1989), VDE 0100, SEV 1000. Accessories: Auxiliary switch for subsequent installation to the left Z-HK 248432 Tripping signal contact for subsequent installation to the right Z-NHK 248434 Remote control and automatic switching device Z-FW/LP 248296 Compact enclosure KLV-TC-4 276241 Sealing cover set Z-RC/AK-4TE 101062 Switching interlock IS/SPE-1TE 101911 Connection diagram Electrical Maximum back-up fuse Design according to IEC/EN 61008 Type G and G/A acc. to ÖVE E 8601 Current test marks as printed onto the device I n = 16-63A I n = 80A I n = 100A Tripping instantaneous Endurance Type G, R 10 ms delay electrical comp. Type S 40 ms delay - mechanical comp. with selective disconnecting Mechanical function Type U (only 30 ma) 10 ms delay Frame size Type U (without 30 ma) 40 ms delay - Device height with selective disconnecting Device width function Mounting Rated voltage U n 230/400 and 240/415 V AC, 50/60 Hz Operation voltage electronic 50 254V AC Degree of protection, built-in Operation voltage test circuit 184 440V AC Deg. of prot. in moisture-proof encl. Rated tripping current I Δn 30, 300 ma Upper and lower terminals Sensitivity AC and pulsating DC Terminal protection Rated insulation voltage U i 440 V Rated impulse withstand voltage U imp 4 kv (1.2/50 µs) Terminal capacity Terminal screw Type G, G/A, R, U (30mA) 3 ka (8/20 µs) Terminal capacity warning contact(s) surge current proof Terminal torque Type S/A, U (except 30mA) typ. 5 ka (8/20 µs) Busbar thickness selective + surge current Tripping temperature proof Storage- and transport temperature Electrical isolation > 4 mm contact space Resistance to climatic conditions Rated short circuit capacity I nc Peak withstand current 10 ka Contact position indicator Tripping indicator Short circuit and overload protection 63 A gg/gl 80 A gg/gl 100 A gg/gl 4,000 operating cycles 20,000 operating cycles 45 mm 80 mm 70 mm (4MU) quick fastening with 2 lock-in positions on DIN rail IEC/EN 60715 IP40 IP54 open mouthed/lift terminals finger and hand touch safe, BGV A3, ÖVE-EN 6 1.5-35 mm 2 single wire 2 x 16 mm 2 multi wire M5 (Pozidriv PZ2) 0.25-1.5 mm 2 (plug in terminals) 2-2.4 Nm 0.8-2 mm -25 C to +40 C -35 C to +60 C 25-55 C/90-95% relative humidity acc. to IEC 60068-2 red / green white / blue

Local Indication RCCB Status indication LED Permanent light green red / yellow / green Normal operation Permanent light yellow The measured residual current is bigger than 30% of the nominal tripping value. Permanent light red The measured residual current is bigger than 50% of the nominal tripping value. Remote Indication Standard Version: 1 contact NO up to 230V AC, 2 terminals, 1 A ohmic load Optional Version: (available upon request) 1 NO + 1 NC up to 110V AC/contact, 2x2 terminals, 1 A ohmic load Terminal capacity of contacts: 0.25-1.5 mm 2 Dimensions (mm) Correct connection 3+N (230/400V) 3phase load without N (184V-254V AC Phase-Phase) 3phase load without N (400V AC Phase-Phase) 1+N (230V) Test button works within 184V 440V AC!, Electronic works within 50-254V AC! 16