Quantum Chargers Enhanced AC Line Transient Immunity

Similar documents
Hardware Implementation of Overvoltage and Under voltage Protection

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Maximize Your Uptime: Reducing Risk of Power Supply Failure

Dirty Power... A Guide to Surge Suppression & Filtering. Surge & Signal Protection for Business-Critical Continuity. EmersonNetworkPower.

AIR COOLED MODULAR RECTIFIER

Power Quality of Commercial Buildings - Advanced

Surge Protector. Esma Khatun

Ethernet Protection A Whole Solution Han Zou, ProTek Devices

Mitigation of Voltage Swells I

An Overview of Surge Protection for the Smart Grid IEEE PES/SPDC WG Matt Wakeham, Chair

The Different Types of UPS Systems

SPECIFIC INTERCONNECTION PROTECTION REQUIREMENTS... 5

Product Overview 2Pro AC Devices Provide Overcurrent/Overvoltage/ Overtemperature Protection for AC Industrial and Appliance Applications

AC Power Quality and Protection

INDUSTRIAL POWER QUALITY PROBLEMS. A. El Mofty K. Youssef. Alexandria Electricity Company, Alexandria Egypt SUMMARY

Motor Surge Suppressors and Cable Considerations

RT12-240V/2.4kW Rectifier Specification

RT7-48V/6kW Specification

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Monitoring Emergency Power Supply Health and Performance to Ensure Peak Reliability

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

RClamp3374N. High Power TVS for Ethernet Interfaces. PRELIMINARY Features

The Seven Types of Power Problems

ASCO SERIES 230 Automatic Transfer Switch

Surge & Filter Protection Addressing your industrial power quality needs.

Technology Live Workshop

RT4F-120V/20A-WAC RECTIFIER

Power Quality of Commercial and Industrial Power Systems

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Welcome to the World of Transients. Transient Generation. The Nature of Transients. Externally Generated Transients. Lightning Generated Transients

Industrial Facility Wide Protection

RClamp TM 0504M RailClamp Low Capacitance TVS Diode Array PRELIMINARY Features

RT9-48V/1.4kW Rectifier Specification

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Features. Applications and Benefits TRC ELECTRONICS, INC

Medium Voltage Metal-Enclosed Power Capacitor Banks

ENGR. MARITES R. PANGILINAN, P.E.E.

Power Quality. The Overlooked Productivity Variable

Voltage surge suppressor

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

A Dell Technical White Paper Dell

TriStar MPPT (150V and 600V) Wind Charging Control Info

Suppressing Transients: A New Approach

www. ElectricalPartManuals. com

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

White Paper Surge Protective Devices in Automatic Transfer Switches

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

CHAPTER 11 HOW TO ENHANCE THE RELIABILITY & POWER QUALITY OF ELECTRICITY SUPPLY

New Solutions. for AC Motor Starters

POWER QUALITY (UNIT-3) ELECTRICAL TRANSIENT:

RT4F-110V/25A RECTIFIER

Voltage Sag Simulator

Voltage Dip-Proofing Inverter

Handling Transient Threats in RS-485 Systems

Power supply (Power supply unit or PSU) is a device or system that supplies electrical or other types of energy to an output load or group of loads.

MV Network Switchgear, Protection and Control

GE Digital Energy. Power Quality

PT SERIES SIP Package

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

electrical disturbances how to protect businesses

SAMPLE. MOVs are sometimes referred

Output Voltage* (nom.)(adjustable)

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Technical Data Sheet Medium Current Power Surge Filters

PDD-300 pulsed diode driver

Voltage Dip-Proofing Inverter

LPI SST Surge Filters

Chapter J. Protection against voltage surges in LV. Contents. General. Overvoltage protection devices. Choosing a protection device

3- and 4-pole switching in UPS installation

The International Power Quality Resource

ECE 528 Understanding Power Quality. Paul Ortmann (voice) Lecture 23

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

AC Line Voltage Transients and Their Suppression

Final Report. Mini Project TET Group nr 7 - Project nr 4. Students: Hans Lavoll Halvorson, NTNU

Smart Inrush Current Limiter Enables Higher Efficiency In AC-DC Converters

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Using the Bitronics 70 Series to Improve Local Monitoring and Control

Datasheet Stock No: RS Pro

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

Cirprotec Technical Article No. 5

RT4B-110V/12A RECTIFIER

Zinc Oxide Varistor Series ( Standard Surge ) :

Surge Protection. The effects of transient voltages on business and the benefits of installing Surge Protection Devices

ADVANCED MICRO SYSTEMS

Common Mode Noise The Often Neglected Tenth Power Problem

Output Voltage* (nom.)(adjustable)

RT4F-48V/50A-WAC RECTIFIER

Application Note: High Power Semiconductor Crowbar Protector for AC Power Line Applications

White Paper Transient Surges and Suppressor Technologies

Standards Update Notice (SUN) Issued: August 11, 2017

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

Safety Standards. Model Number:

SECTION VARIABLE FREQUENCY DRIVES

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ELG4125: System Protection

Bulletin 294 ArmorStart LT Distributed Motor Controllers Feature Diagram

Transcription:

Introduction Quantum Chargers Enhanced AC Line Transient Immunity By: Nasser Kutkut, PhD, DBA Advanced Charging Technologies Inc. This white paper outlines the most common AC power quality disturbances and how the Quantum chargers were designed to provide additional immunity to such disturbances. Nominal AC line Fluctuations In a typical AC voltage distribution system, the steady state operating voltages will vary from nominal values due to voltage drops in the system as well as changes in the system s operating conditions. Utilities are required to maintain system service voltages within a suitable range. As such, utilities must regulate the service voltages to customers to ensure that voltage variation remains within acceptable limits. Voltage regulators in substations or on feeders are typically used to adjust the primary voltage to maintain service voltages within acceptable limits. These limits are set by various regulatory bodies and standards. Most utilities in the US follow the ANSI voltage standards (ANSI C84.1). The ANSI C84.1 is the American National Standard for Electric Power Systems and Equipment Voltage Ratings (60 Hertz). The standard establishes the nominal voltage ratings and operating tolerances for 60-Hz electric power systems above 100 volts up to a maximum system voltage of 1200 kv (steady-state voltage levels only). The standard specifies acceptable operational ranges at two locations on electric power systems: Service Voltage: The voltage at the interconnect point of the AC power system and the customer s facility, which is normally at the meter. Maintaining acceptable voltage at the service point is the utility s responsibility. Utilization Voltage: The voltage at the line terminals, where electrical equipment is connected. This voltage is the facility s responsibility. The ANSI C84.1 divides voltages into two ranges. Range A is the optimal voltage range while Range B is acceptable, but not optimal (Table 1). Utilities must ensure that the service voltages remain within these limits and equipment manufacturers must design their equipment to operate satisfactorily within the given limits. While in steady state, the service and distribution voltages remain within the preset limits, many power quality disturbances occur within a power system that cause momentarily and extended variations of service and utilization voltage limits that exceed the ANSI C84.1. Various power quality disturbances will be discussed next. Advanced Charging Technologies Inc. 1

Table 1: Voltage ranges according to ANSI C84.1 standard For 120V 600V Systems Nominal Nominal Service Voltage (V) Service Utilization Range A Range B Voltage (V) Voltage (V) Max Min Max Min 120 115 126 114 127 110 240 230 252 228 254 220 480 460 504 456 508 440 600 575 630 570 635 550 AC Power Quality Disturbances A wide number of power quality disturbances can affect the performance of electrical equipment at manufacturing and distribution facilities causing momentary or extended variations is the AC service or utilization voltages. Some of the most common power quality disturbances include: 1. Voltage Spikes / Surges 2. Interruptions 3. Voltage Sags 4. Undervoltages 5. Voltage Swells 6. Overvoltages Voltage Spikes or Surges Voltage spikes or surges (also referred to as impulsive transients) are sudden high peak events that increase the nominal AC voltage for very short duration (Fig. 1). Fig. 1: Typical AC voltage spike Advanced Charging Technologies Inc. 2

The most common cause of voltages pikes and surges is lightning strikes. Other causes include electrostatic discharge (ESD), switching of inductive loads, switching of power factor correction capacitor banks, poor grounding, and clearing of utility line faults. These factors can result in large amounts of energy transfer with very short rise and decay times The table below shows the various transient sources, magnitudes, and durations. Table 2: Examples of transient sources and magnitudes Voltage Current Rise-time Duration Lighting 25kV 20kA 10 µs 1ms Switching 600V 500A 50µs 500ms EMP 1kV 10A 20ns 1ms ESD 15kV 30A <1ns 100ns Interruptions Power interruptions occur when the AC line voltage decreases to less than 10% of the nominal line voltage (0.1 p.u.) for a period not longer than 60 seconds (Fig. 2). If the interruption lasts longer than one minute, it becomes a sustained interruption. Fig. 2: Power interruption (few cycles) Interruptions are usually the result of some sort of electrical power system failure or damage that may be caused by lightning, trees, animals, weather (high winds, heavy snow or ice on lines), insulation failure, improper/faulty grounding, equipment failure, or automatic re-closure of protection devices to isolate faulty sections of the system. Interruptions can be classified, depending on their durations, as shown in Table 3 below. Advanced Charging Technologies Inc. 3

Table 3: Classification of Interruptions according to IEEE 1159 Type of Interruption Duration Instantaneous 0.5 30 cycles Momentary 30 cycles 3 secs Temporary 3 secs 2 mins Sustained > 2 minutes Voltage Sags A voltage sag is a momentary reduction in the AC rms voltage to between 10% to 90% (0.1 to 0.9 p.u.) of the nominal rms voltage for period of half a cycle up to one minute. It is caused by AC line faults, starting of electric motors, switching on heavy loads, or excessive loading. Fig. 3 shows a voltage sag to 50% of nominal rms voltage. Undervoltages Fig. 4: AC voltage sag An undervoltage is a decrease in the AC rms voltage to less than 90% (<0.9 p.u.) of the nominal rms voltage for a duration longer than one minute (Fig. 5). Undervoltages are the most common power quality disturbance that occurs in industrial facilities. Their effect can be quite severe as they may cause damage of sensitive equipment, such as Programmable Logic Controllers (PLCs), Adjustable Speed Drive (ASDs), and Chiller controllers. The most common causes of undervoltages include closing and opening of circuit breakers, AC line faults, switching on large inductive loads, such as motor starting and transformer energizing, and equipment failure due to insulation breakdown, heating or short circuit. Advanced Charging Technologies Inc. 4

Fig. 5: AC undervoltage Undervoltages can be classified depending on their durations as shown in Table 4 below. Table 4: Classification of Undervoltage according to IEEE 1159 Type of Undervoltage Duration Magnitude Instantaneous 0.5 30 cycles 0.1 0.9 p.u. Momentary 30 cycles 3 secs 0.1 0.9 p.u. Temporary 3 secs 1 min 0.1 0.9 p.u. Voltage Swells A voltage swell is a momentary increase in the AC rms voltage to between 110% to 180% (1.1 to 1.8 p.u.) of the nominal rms voltage for period of half a cycle up to one minute (Fig. 6). It is caused by switching off heavy loads, loss of generation, badly regulated transformers, and AC line faults. Fig. 6: AC voltage swell Advanced Charging Technologies Inc. 5

Overvoltages An overvoltage is an increase in the AC rms voltage of greater than 10% (>1.1 p.u.) of the nominal rms voltage for a duration longer than one minute (Fig. 7). It results from switching off large loads, incorrect tap settings of distribution transformers, energizing of capacitor banks, AC line faults, and/or ungrounded or floating ground delta systems. Fig. 7: AC overvoltage Overvoltages can be classified depending on their durations as shown in Table 5 below. Table 5: Classification of Overvoltage according to IEEE 1159 Type of Overvoltage Duration Magnitude Type of Overvoltage Duration Magnitude Instantaneous 0.5 30 cycles 0.1 0.9 p.u. Momentary 30 cycles 3 secs 0.1 0.9 p.u. Quantum Chargers Enhanced AC Line Transient Immunity The Quantum charger, ACT s flagship product, is the industry s first smart industrial charger appliance that features many advanced energy efficiency and energy management capabilities as well as communication and smart grid integration (Fig. 8). The Quantum charger is first industrial smart appliance that is highly efficient, internet protocol (IP) addressable, and can be controlled by external signals from the utility, enduser, or other authorized entity. The Quantum charger s design encompasses many advanced protection functionalities aimed at enhancing the immunity of the chargers to AC power quality disturbances. The following is a summary of the key design features that yield enhanced immunity. Advanced Charging Technologies Inc. 6

Fig. 8: ACT Quantum chargers: Industry s first smart charging appliance AC Input Protection to Voltage Spikes / Surges In order to provide extra immunity to AC voltage spikes / surges, the Quantum chargers design include: A UL1449 compliant thermally protected phase to phase transient voltage suppression devices (TMOVs) capable of absorbing 400 Joules (200kW for 2 milliseconds) and up to 10,000 Amperes of transient current Two sections of phase to phase suppression capacitors A common mode/differential mode suppression filter inductor Phase to earth ground capacitor for common mode noise and transient suppression AC Input Protection to Voltage Swells / Overvoltages To provide protection for momentary voltage swells or extended overvoltages, the Quantum chargers design feature the following: A proprietary converter topology that provides 40% voltage operating margins for input side semiconductor switches at high line and nearly 50% margin at nominal line. This large derating eliminates failures of these devices due to AC voltage swells and over-voltage conditions. This is especially critical in industrial installations where power quality is poor. Input DC protection to provide extra immunity to the downstream power devices and circuits. This includes: A 1000V/1600V input rectifiers, providing 33% to 77% extra voltage margin at high line Large DC input choke and supplemental inrush surge protection, which prevents large transient currents from flowing into the input circuit Advanced Charging Technologies Inc. 7

Nominal input side DC energy storage of 30 Joules, which absorbs low frequency AC input disturbances, thus reducing any stress to the input side semiconductor devices Advanced controls, which temporarily disables the power circuitry and pauses the charge cycle when an extended voltage swell or overvoltage condition is detected. The advanced controls continuously monitors the AC line voltage and automatically enables the power circuitry to resume the charge cycle once the AC line voltage recovers to nominal values. AC Input Protection to Voltage Sags / Undervoltages To provide protection for momentary voltage sags or extended undervoltages, the Quantum chargers design feature the following: A proprietary converter topology that provides 20% power derating, which allows the Quantum chargers to operate reliably at line voltages well below the 10% limit set by ANSI. This large derating eliminates failures of power devices due to AC voltage sags and under-voltage conditions, which is especially critical in industrial installations where power quality is poor. Advanced controls, which temporarily disables the power circuitry and pauses the charge cycle when an extended voltage sag or undervoltage condition is detected. The advanced controls continuously monitors the AC line voltage and automatically enables the power circuitry to resume the charge cycle once the AC line voltage recovers to nominal values. Conclusion The Quantum chargers have been designed to provide extra immunity to AC line transients and surges. The enhanced immunity allows the Quantum chargers to work very reliably in industrial and commercial installations, where power quality issues are very frequent. Field deployment of Quantum chargers in installations with extreme power quality disturbances has proven very successful, making the Quantum chargers the most reliable and resilient industrial charger on the market. References 1) Joseph Seymour, The Seven Types of Power Problems, White Paper 18, Schnieder Electric. https://goo.gl/ue1cef 2) Kevin Olikara, Power Quality Issues, Impacts, and Mitigation for Industrial Customers Rockwell Automation, Inc. https://goo.gl/erd09n 3) M. Paul, A. Chaudhury, S. Saikia, Hardware Implementation of Overvoltage and Under voltage Protection, International Journal of Innovative Research In Electrical, Electronics, Instrumentation And Control Engineering, Vol. 3, Issue 6, June 2015. 4) Transient Voltage Suppressors (TVS Diode) Applications Overview, Application Note, Littlefuse. https://goo.gl/xy8kjs Advanced Charging Technologies Inc. 8