The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

Similar documents
Assembly Instructions scancontrol 2700/2750 (500)

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

Instruction Manual scancontrol 29xx

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter

Instruction Manual scancontrol 27x0

Instruction Manual scancontrol 29xx/BL

Instruction Manual scancontrol 2700 / 2710 LLT LLT LLT LLT LLT LLT

More Precision. 2D/3D laser scanner (laser profile sensors)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

camera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition

Quick Manual DT6220 DT6222 DT6230

More Precision. optoncdt // Laser Triangulation Displacement Sensors

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

PHOENIX CONTACT - 10/2009

Instruction Manual DS05(03) DS05(04) DS05(07) DS05(14) DS05(15) DS1 DS1(04) DS1/T

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

Measurement range, typical

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

More Precision. scancontrol BL // 2D/3D blue laser scanner

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMC III Universal Sensor

Absolute Encoders Multiturn

Laser Triangulation Displacement Sensors

PLIN-LWL Optical Coupler for LIN Data Transmission. User Manual. Document version ( )

Operating Instructions 10/200 10/400 25/200 25/400

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optoncdt // Laser displacement sensors (triangulation)

F1000 User's Manual. (Version: V1.01)

Measurement range, typical

LVX Control Unit. Features:

IMC-21 Quick Installation Guide

The World s Smallest TOF Sensor lineup with analog output type

FL MC 2000E (SM40) LC

(threaded M5) 7-pole fem. connector Binder Series 712 (connection Master/Slave) Connecting cable: cab-las7-male not necessary for single system!

CMC III Temperature/Humidity Sensor

Mounting holes. Transmitter optics. 8-pol. fem. conn. Binder Series 712 (connection to PLC) Connecting cable: cab-las4/pc or cab-4/usb or cab-4/eth

Instruction Manual reflectcontrol Compact RCC RCC RCC RCC RCC RCC

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

(see also technical drawings) Width with inlay

More Precision. optocontrol // Optical precision micrometers

Minimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)

Access Terminal IF-800

MC 11 EB-2 Power supply cabinet with external bus, AC version

Laser Triangulation Displacement Sensors

VersaMax IP I/O Module

QUICK START GUIDE ODT-MAC40*-*-RD

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optocontrol // Optical precision micrometers

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

In-Sight 7010C/7200C/7400C

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

More Precision. optoncdt // Laser displacement sensors (triangulation)

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Laser Triangulation Displacement Sensors

AX3000 Platine Terminal Ethernet TCP/IP

MLC 420. MAGNETIC Press Brake ENCODERS OPERATION MANUAL

IF-80x Outdoor Terminal

M2-iLAN-2 Laser Scanner

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO

More Precision. colorsensor // Color Sensors, LED Analyzers

More Precision. colorsensor // Color sensors, LED Analyzers

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Instruction Manual C-Box/2A

4.8 Expansion Module MAC00-FS1/FS4

Delivery. Connection. C. AA+BB Helicoidal cable 2. Radial M12 8p CCW. 3. Radial M23 12p CCW

ADN PS. Power Supply. Instruction manual

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

More Precision. optoncdt // Laser displacement sensors (triangulation)

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Absolute encoders - SSI

SK TU4-IOE-M12-C Part Number

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

QUICK START GUIDE 2-D Laser Scanner

VersaMax IP Input Module

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English

Flow Sensor SONOFLOW CO.55

AX3000 Platine Terminal Ethernet TCP/IP

More Precision. 2D/3D laser scanner (laser profile sensors)

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

NOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental

IMC-21A Quick Installation Guide

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

CPCI-PS24 24V-Power Supply

More Precision. colorsensor // Colour Sensors, LED Analyzers

CinCam CCD - Technical Data -

Transcription:

Assembly Instructions scancontrol 2600/2650/2900/2950 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply must not exceed the specified limits. > > Danger of injury, damage or destruction of the sensor Avoid shock and vibration to the sensor. Avoid continuous exposure to dust and spray on the sensor. Avoid exposure to aggressive materials (e. g. washing agent, penetrating liquids or similar) on the sensor. > > Damage to or destruction of the sensor Read the detailed instruction manual before operating the sensor. You will find this manual on the provided CD or online at www.micro-epsilon.com. 2. Notes on CE Identification The following applies to the scancontrol 26xx/29xx: EU directive 2014/30/EU EU directive 2011/65/EU, RoHS category 9 The sensor is designed for use in industry and satisfies the requirements. The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed. 3. Proper Environment Protection class: IP 65 Operating temperature: 0 to +45 C (+32 to +113 F), by free circulation of air Storage temperature: -20 to +70 C ( -4 to +158 F) Humidity: 5-95 % (non condensing) 4. Scope of Delivery of scancontrol 26xx/29xx 1 Sensor scancontrol 26xx/29xx with integrated controller 1 Multifunction cable PC2600/2900-5, length 5 m; for power supply, trigger and RS422; Escha screw connector and free cable ends Sensor acceptance report / assembly instructions 2 protective caps scancontrol Demo-CD with drivers, programs and documentation

5. Laser Safety The scancontrol 26xx/29xx sensors operate with a semiconductor laser having a wavelength of 658 nm (visible/red). The laser operation is indicated visually by the LED on the sensor. scancontrol 26xx/29xx sensors with a maximum laser power up to 8 mw are classified in Laser Class 2M (IIM). The following information labels are fitted to the sensor housing (front and rear side). If both information labels are hidden in the installed state, the user must ensure that additional labels are fitted at the point of installation. Hazard to the eye via laser radiation! Consciously close your eyes or turn away if the laser radiation impinges on the eye. Lasers of Class 2M are not subject to notification and a laser protection officer is not required. Mark the laser area recognizable and everlasting. Laser Class 3B scancontrol 26xx/29xx sensors with a maximum laser power up to 50 mw are classified in Laser Class 3B (IIIB). When using lasers of 3B class appropriate protective glasses are necessarily! Injury of the eyes and the skin by laser radiation! Class 3B (IIIB) laser sensors are notifiable and a laser protection officer is required either. During operation the laser area has to be restricted and marked. The following information label should be fitted to the sensor housing (front and rear side): Warning- Laser radiation Avoid exposure to beam Class 3B Laser Product IEC 60825-1: 2015-07 P0 50mW, P P 50mW; = 658nm; F = 0...4kHz, t = 1µs... Beam attenuator The beam attenuator prevents access to all laser and collateral radiation. The figures show the sensor with closed and open beam attenuator. The beam attenuator must be open during measurement. i Sensors of Laser Class 3B (IIIB) need an external key switch to switch off the laser, see Chap. Laser switching.

6. Connections, LED Displays 1 2 Ethernet Connection, Standard Connection to PC 1 Ethernet port 2 Multifunction port (Power supply, IO) RJ45 connector 8-pin. screw connector (sensor side) Pin no. Color stranded hookup Pin no. 10BaseT, 1000BaseT wire SC2600/2900-x 100BaseTX 1 white (orange) 5 Tx+ D1+ 2 orange 6 Tx- D1-3 white (green) 8 Rx+ D2+ 4 blue 1 D3+ 5 white (blue) 2 D3-6 green 7 Rx- D2-7 white (brown) 3 D4+ 8 brown 4 D4-1 View on pin side male cable connector 1 7 8 2 6 3 4 5 View on solder pin side screw connector The sensor supports an automatically, sensor-adapted IP address in the link-localnet (169.254.x.x). No collision detection is implemented. This is also the default setting. The sensor supports DHCP. This setting is activated by default and has priority over the retrieval in the link-local-net. The sensor scancontrol 26xx/29xx supports Power over Ethernet. If the sensor is connected to a network adapter/switch that is capable of POE and if you also use the power supply of the multifunction port, these two power supplies have to be galvanically isolated. > > Damage of the sensor and/or the Ethernet card! A fixed IP address can be assigned. Use the program SensorFinder delivered on the CD, to make the above-described sensor settings.

Multifunction Port Designation Sensor connector Pin Cable color PC2600/2900-x Notes +Ub 9 red + 11 V - 30 V DC (rated value 24 V); max. 500 ma GND 2 blue 0 V +Laser on/off 3 white -Laser on/off 1 brown RS422 12 red-blue /RS422 11 gray-pink optional RS422, input respectively output In1 6 yellow Digital Input 1 GND-In1 4 green Ground In1 In2 5 pink Digital Input 2 GND-In2 8 gray Ground In2 In3 10 violet Digital Input 3 GND-In3 7 black Ground In3 Schirm Gehäuse black No galvanic connection to GND 10 1 9 2 3 8 7 12 6 4 11 5 12-pin screw connector, view on solder pin side GND: galvanically isolated from 1, 2, 3, RS422, Laser on/ off Laser on/off: Input galvanically isolated from GND, IN1 3, RS422 IN1, IN2, IN3, RS422: Inputs galvanically isolated from GND and Laser on/off RS422, Synchronisation The RS422 connection (Pin 11 and 12 of the multifunction port) can be used with either of the following configurations: RS422 (half-duplex): Load user modes and sensor control. Synchronization/triggering: Synchronization respectively triggering using switching signals. Trigger, Encoder, Mode Switching The switching inputs of the multifunction port can either be used for encoder input, for trigger input or for loading previously stored user modes. The signal levels are switchable for all switching inputs between LLL (low-voltage-, TTL logic) and HLL (high-voltage-, HTL logic): LLL level: Low 0 V 0.8 V, high 2.4 V 5 V, internal pull-up 10 kω to 5 V HLL level: Low 0 V 3 V, high 11 V 24 V (permitted to 30 V), internal pull-up 10 kω to 24 V Pulse duration: 5 µs

External Laser Switching The sensors of the scancontrol 26xx-x/SI and scancontrol 29xx-x/SI series offer this function. Use a serial key switch inside the control circuit to switch off the laser. You will find details for the wiring in the instruction manual, Chap. 5.2.6. LED Displays LED laser on LED state : Two-color LED (red / green) Green: Laser on Green: Measurement Green flashing: Data transmission Red flashing: Error code Note: The state LED flashes green, long during active data transmission and short for controller accesses. The state LED indicates different error conditions by flashing. If no flashing occurs for several seconds, no error has occurred. For a detailed description of the error codes, please refer to the instruction manual, Chap. 11. 7. System Requirements scancontrol Configuration Tools The following minimum system specification is necessary: Windows 7 (32 bit and 64 bit), Windows 8 or 8.1 (32 bit and 64 bit), Windows 10 (32 bit and 64 bit) 1-GHz or faster (32 bit and 64 bit) processor / 1 GB RAM Screen resolution: 1024 x 768

8. Quick Start: Commissioning, Software Install the software. Please insert the scancontrol Demo CD in the CD-ROM device. Follow the dialog through the installation process. A. Reading of installation help B. Installation of software C. Further informations in the online documentation Mount the sensor according to the installation instructions. Connect the sensor to the PC via the Ethernet cable. Connect the sensor to display or monitoring units. Connect the sensor to the power supply. The connectors for Ethernet and the multifunction port are fitted with an Escha screw connector. i Loosen the screws before you remove the connector from the socket. Connect the shield of the power supply cable to the PE protective earth conductor of the main power supply. Close unused connection plugs with the provided protective caps. Switch on the power supply (24 VDC). Only connect the sensor to the peripheral equipment, if it is disconnected from the power supply, i.e. only when the operating voltage is switched off. The sensor needs a warm-up time of typically 20 minutes for high precision measurements. Please wait until the scancontrol device is recognized by the PC. This may take a few seconds. Now you can operate the scancontrol measurement system with the scancon- TROL software packages. i Operating a scancontrol sensor via Ethernet may require a modification of the IP settings of the PC/sensor or a modification of the firewall settings, see Chap. 5.2.5 of instruction manual.

9. First Profile Now start the scancontrol Configuration Tools software. Click on Display Profiles in the main window. If the software shows the error message No scancontrol found in the status line, please check the Ethernet connection between scancontrol and PC. On the left side you can adjust the settings for your measurement task, the right side shows the profile data and information about the measurement. 10. How to Access Profile Data Profile data of scancontrol can be accessed via: GigEVision and GenICam for digital cameras via Ethernet interface SDK for fast application integration (C, C++, C# and others) For details how to access profile data refer to the enclosed online manual.

11. Further Information Please refer to the enclosed online manual the section Status and Error Messages and Notes in the scancontrol Configuration Tools manual. You will find details to the separate programs in the respective instruction manuals or in the instruction manual of this sensor, Chap. 6.2. You will find the instruction manuals online or on the provided CD. www.micro-epsilon.com MICRO-EPSILON Messtechnik GmbH & Co. KG Königbacher Str. 15 94496 Ortenburg / Germany, Tel. +49 (0) 85 42/1 68-0 *X9771299-A04* X9771299-A041086HDR