Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Similar documents
Conductive Sensors 2 to 4-point level controller Type CL with teach-in

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Photoelectrics Retro-reflective, Industrial Door Market Type PD86.AP12, Polarized, Relay Output, Mute Input

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Classification Enclosure rating Input voltage Type of

Syr-line TMR48D Digital Timer

61F-GP-N8D. Model Number Structure. Ordering Information. Conductive Level Controller. Model Number Legend. List of Models

02/11/2015

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

02/11/2015

Conductive Level Controller

RCMB20/RCMB Series

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

RM35LM33MW liquid level control relay RM35-L V AC/DC

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

SPST-NO SPDT DPST-NO DPDT

Syr-line TMR48D Digital Timer

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

RUC industrial relays of small dimensions

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Displays Transducers. Displays and transducers

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

RM35LM33MW liquid level control relay RM35-L V AC/DC

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Operating Instructions. For. Level Control Module. Model SSR 1000

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

02/11/2015

Zelio Control-modular measurement and control relays 1

02/11/2015

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Measuring and Monitoring Relays

78 Series Electromechanical Relay Selection Guide

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector

Switching relay CT-IRE with 1 c/o (SPDT) contact

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

08/07/2015

Temperature Controller E5C4

RM4LA32M liquid level control relay RM4-L V AC

RM84 miniature relays

FOTOBUNKA S ODRAZKOU PD86

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Miniature Relays Series M25 Type M25-1 pole 16 A Monostable

Zelio Count - Counters RC87610

RUC industrial relays of small dimensions

MasterINTERFACE 39 Series - Relay interface modules

TIME DELAY RELAYS Product Summary

VariTrans P The Problem The variety of tasks results in a large number of different devices.

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

Amplifiers, Counters, Timers & Controls

VZBs. Power PCB Relay RT2 2 pole 8 A, DC and AC-coil. Features. Contact data

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

ITEM ESM-BA301

E-STOP relays, safety gate monitors

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

Micro Contactor MA Series

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

V REG.-Nr. 3919, Z E214024

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

RUC industrial relays of small dimensions

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Alarm Unit DG 3200 Control And Monitor Standard Signals

ISOMETER isoev425 with coupling device AGH420

Safety control unit B1 / B1. for 2 to 16 machine safety sensors. Use. Types. + PLd according to EN ISO

External level devices for conductive point level switch

Contact protection relay

RUC-M industrial relays for DC loads

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Safety Temperature Limiter TT-STL 50

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Process displays For current and voltage

Solid-state Timer H3YN

SBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description

PI-EX-ME-2NAM/COC-24VDC

RM84 / RM85 / RM87 Miniature Electromagnetic Relays

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Transcription:

Conductive Sensors to 4-point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying applications w-voltage AC electrodes Easy installation on DIN rails or with 11 pin circular plug Rated operational voltage: 4 VAC/DC, 115 VAC or 30 VAC Output x8a/50 VAC SPDT relay LED indication for: Calibration, faulty operation and relay status Product De scrip tion µ-processor based level controller for liquids with a wide sensitivity range (like sewage water, chemicals, salt water etc.). The controller has a separate output for alarm Type Selection indication in case of a tank running dry or if an overflow con dition occurs. 8A SPDT/SPST relay output, NO/NC. Ordering Key Type DIN rail mounting Inputs Function Adjustment Outputs Relay versions CLD4MTDM4 Mounting Relay Ordering no. Ordering no. Ordering no. Supply: 4 VAC/DC Supply: 115 VAC Supply: 30 VAC DIN-rail SPDT + SPST CLD4MTDM4 CLD4MTD115 CLD4MTD30 11-p circular plug SPST CLP4MTAM4 CLP4MT15 CLP4MTA30 Specifications Rated operational voltage (U B) Pin & 10 30 195 to 65 VAC, 45 to 65 Hz 115 98 to 13 VAC, 45 to 65 Hz 4 19. to 8.8 VAC/DC Rated insulation voltage <.0 kvac (rms) Rated impulse withstand voltage 4 kv (1./50 µs) (line/neutral) Rated operational power AC supply 5 VA AC/DC supply 5 VA / 5 W Delay on operate (t V) < 300 ms Outputs Make or break on DIP-switch Rated insulation voltage 50 VAC (rms) (cont./elec.) Relay Rating (AgCdO) µ (micro gap) Resistive loads AC1 8 A / 50 VAC (500 VA) DC1 1 A / 50 VDC (50 W) or 10 A 5 VDC (50 W) Small induc. ads AC11 0,4 A / 50 VAC DC13 0,4 A / 30 VDC Mechanical life (typical) 30 x 106 operations @ 18 000 imp/h Electrical life (typical) AC1 > 50 000 operations Level probe supply Max. 1 VAC Level probe current Max..5 ma Sensitivity 0Ω to 0KΩ Factory preset: 47KΩ Dielectric voltage >.0 KVAC (rms) (contacts / electronics) Rated impulse withstand volt. 4 kv (1./50 µs) (contacts / electronics) (IEC 664) Operating frequency (f) Relay output 1 HZ Response time 1 s (3,5 s with filter) Environment Overvoltage category III (IEC 60664) Degree of protection IP 0 /IEC 6059, 60947-1) Pollution degree (IEC 60664/60664A, 60947-1) Temperature Operating -0º to +50ºC (-4º to + 1ºF) Storage -50º to +85ºC (-58º to +185ºF) Housing material NORYL SE1, light grey Weight AC supply 00 g AC/DC supply 15 g Approvals UL508, c us CE marking Yes Specifications are subject to change without notice (06.06.011) 1

Mode of Operation Connection cable, 3, 4 or 5 conductor PVC cable, normally screened. Cable length: max. 100 m. The resistance between the cores and the ground must be at least 0k. Normally, it is re commended to use a screened cable between probe and controller, e.g. where the cable is placed in parallel to the load cables (mains). The screen has to be connected to Y5 (reference). DIP-switch setting Select the needed function on the DIP-switches, so that the desirable application occurs. Press the pushbutton in front of the controller shortly, until the green LED flashes once. The DIPswitch setting will now be read by the controller. Teach-in: Make sure that the reference electrode and one of the other electrodes are in contact with the liquid approximately 1 cm. Press the teach pushbutton at the front of the controller for approximately seconds, until the green LED turns OFF. The controller will now auto-adjust itself ac cord ing to the re sistance of the measuring liquid. If the resistance of the liquid is outside the maximum range handled by the controller, the green LED will flash quickly for a period of seconds, indicating a wrong teach-in. Filter The signal delay is selectable from 1 second or 3 seconds, and works for the on/off switching of the output relays. Example 1 The diagram shows the level control connected as max. and min. control, i.e. registration of levels + alarm levels. The re lays react to the low alternating current created when the electrodes are in contact with the liquid. The reference (Ref) must be connected to the container or if the container consists of a non-conductive mater ial, Example 1 (Din-rail) 1 Pump on/off Y4 Y Y5 Y3 Y1 4 Alarm on/off A to an additional electrode. (To be connected to pin Y5). In the diagram this electrode is shown by the dotted line.) The alarm outputs utilize electrodes on Y1 for alarm and Y4 for alarm. Function: Charge or Discharge used as a minimum-maximum control for up to two individual systems, with the same kind of liquid to be measured. Function selection 3 Relay 1 - Charge (off) or Discharge (on) 4 Relay - Charge (off) or Discharge (on) X-ERENCE Y 6 A 10 1-3 1 11 4 9 Charging or discharging 1 Y Y4 Y5 4 A Charging or discharging Charging Relay on pumping contact (make) Discharging Relay on pumping contact (make) Specifications are subject to change without notice (06.06.011)

Operation Diagram Function: Charge and Discharge used as a minimum-maximum control for two systems, a charging system and a discharging system, with the same kind of liquid to be measured and one common pump. DIP switches (Plu Function selection 3 No function 4 No function X-ERENCE Y 6 A 10 1-3 1 11 4 9 Discharging (Tank 1) 1 Relay 1 Pump contactor coil Y Y4 Y5 4 Not in use A Charging (Tank ) Charging and discharging tank 1 tank 1 tank tank Relay 1 on pumping contact Function: Charge or Discharge with high and low alarms used as a minimum-maximum control charging or discharging system, with and Alarm output. Function selection 3 Relay 1 - Charge (off) or Disc 4 Relay X-ERENCE Y 6 A 10 1-3 1 11 4 9 1 Pump on/off Y4 Y Y5 Y3 Y1 4 Alarm on/off A Charging LO HI Relay 1 on pumping contact Relay on alarm contact Specifications are subject to change without notice (06.06.011) 3

Operation Diagram Function: Charge or discharge with low alarm used as a minimum-maximum control charging or discharging system, with one alarm output. Function selection 3 Relay 1 - w alarm 4 Relay - Charge (off) or Disc X-ERENCE Y 6 A 10 1-3 1 11 4 9 Y Y4 Y5 1 4 alarm on/off Pump on/off A Function: Charge or discharge with high alarm used as a minimum-maximum control charging or discharging system, with one alarm output. Function selection 3 Relay 1 - Charge (off) or Disc 4 Relay - gh alarm X-ERENCE Y 6 A 10 1-3 1 11 4 9 Y Y4 Y5 1 4 Pump on/off alarm on/off A Function: Direct input- output used as direct input/ output, where each of the two inputs (electrodes) controls an individual relay output: Electrode no. 1 = Relay no. 1 Electrode no. = Relay no.. DIP switches (Plu Function selection 3 No function 4 No function Direct input- output X-ERENCE Y 6 A 10 1-3 1 11 4 9 Ref Y Y5 Y1 1 Relay 1 Relay 4 A Relay 1 Relay 4 Specifications are subject to change without notice (06.06.011)

Operating Schedule The following schedule provides an overview of the setup and failure situations Situation Condition Action Green Control lamp Read DIP-switch setting The DIP-switch setting has to match one of the descriptions written in mode of operation Press the Teach-button in front of the controller shortly until the green control lamp turns off. Release the teach button immediately Teach button Green lamp Teach-in Fill the tank with the liquid to be measured until the second longest electrode is immersed approx. 1cm Press the Teach button in front of the controller for approx. seconds until the green control lamp turn off continuously. Release the teach button Teach button Green lamp Failure indication The Green lamp is flashing fast for approx seconds after a teach-in operation Control the electrode for short-cut connections. Control that the resistance of the measured liquid is within the specified range Teach button Green lamp Wiring Diagram Din-rail version Plug version - - Y4 Y3 Y Y1 Y5 1 4 A - - 4 5 6 8 7 3 9 10 1 11 Ref (PE) Ref (PE) Specifications are subject to change without notice (06.06.011) 5

Dip Switch Settings Din-rail version 1 Charge or Discharge + Alarm (Relay ) 1 Charge and Discharge 1 in out 1 Charge or Discharge 3 Relay 1 - Charge (Y1 & Y) 3 Relay 1 - Discharge (Y1 & Y) 4 Relay - Charge (Y3 & Y4) 4 Relay - Discharge (Y3 & Y4) 5 Relay 1 + not inverted 5 Relay 1 + inverted 6 Filter off 6 Filter on Plug version 1 Charge or Discharge + Alarm (Relay ) 1 Charge and Discharge 1 in out 1 Charge or Discharge 3 Relay 1 - Charge (8 & 6) 3 Relay 1 - Discharge (8 & 6) 4 Relay - Charge (5 & 4) 4 Relay - Discharge (5 & 4) 5 Relay 1 + not inverted 5 Relay 1 + inverted 6 Filter off 6 Filter on Dip Switch Function Dip-switch 1 3 4 5 6 Functionality Comments Function settings 0 0 Charge or discharge +alarm One system in one tank 1 0 Charge and discharge One system in two tanks with one relay output 0 1 in - out Each input direct controlling one output relay 1 1 Charge or discharge seperate systems Relay #1 function 1 1 0 Discharge Emptying system #1 1 1 1 Charge Filling system #1 Relay # function 1 1-0 Dicharge Emptying system # 1 1-1 Charge Filling system # Relay output - - - - 0 Normally open Relays in normally open position - - - - 1 Normally closed Relays in normally closed position Filter - - - - - 0 Normal filter time On-delay <0.5s - - - - - 1 Extended filter time On-delay <.0s 6 Specifications are subject to change without notice (06.06.011)

Dimension Drawings Din-rail version Plug version 45 41,5 1 60, 63 81 35,5 35,5 Accessories 11 pole corcular socket Mounting rack ZVD11 SM13 Delivery Contents Amplifier Packaging: Carton box Manual Specifications are subject to change without notice (06.06.011) 7