LabVIEW Tutorials. T.1 Temperature Measurement and Cold Junction Compensation (CJC) LUMS School of Science and Engineering

Similar documents
Introduction to Labview and Temperature Measurement

Additional products and features

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

Lab Exercise 2: Data Acquisition with NI LabVIEW

Hardware: Acquiring Data and Communicating with Instruments

1. Learn about LabView software and its different components

Install the Software and Hardware

NI mydaq HANS-PETTER HALVORSEN, Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics

NI-DAQmx Basic Course NITS John Shannon

Determination of Drag Coefficient

BE/EE189 Design and Construction of Biodevices Lecture 5. BE/EE189 Design and Construction of Biodevices - Caltech

Strain and Force Measurement

Hands-on Lab 2: LabVIEW NI-DAQ Basics 2

Advanced NI-DAQmx Programming Techniques with LabVIEW

DT9828. USB Powered Thermocouple Measurement Module. Key Features: Analog Input Channels

Wireless DAQ using ZigBee

Create a worksheet that collects, displays and saves temperature data

Measurement & Automation Explorer (MAX) View and control your devices and software

Step-by-Step Data Acquisition Part II Exercise 2: Generating an Analog Output Waveform

Høgskolen i Telemark Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics.

Installation Instructions for: Channel Thermocouple Amplifier

Ch En 475: Introduction to Instrumentation and Signal Processing with Labview

Lab Exercise 4: Analog & Digital I/O Signals

Figure 3.174: Illustration of the code of the event f USB that plots an USB camera frame if the typed frame is under the acceptable limits (case 0)

Getting Results with CompactRIO and LabVIEW

1. Main Features. TCIC User s Manual

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

LabVIEW Core 1. What You Need To Get Started. File Locations. The course installer places the course files in the following location: ni.

Dept. of Electrical, Computer and Biomedical Engineering. Instrumentation for the data acquisition laboratory

Data Acquisition HANS-PETTER HALVORSEN,

Ch En 475: Introduction to Instrumentation and Signal Processing with Labview

Data Acquisition in LabVIEW

Creating a NI-DAQmx Task, Channel, or Scale in a Project

SCXITM. SCXI-1125 User Manual. SCXI-1125 User Manual. October C-01

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

Data acquisition hardware

OpenStax-CNX module: m Thermometer VI * National Instruments

Installation Guide: Quanser Rapid Control Prototyping Toolkit 2016 for NI myrio

SCXI OFFSET-NULL AND SHUNT-CALIBRATION HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE

Specifications

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

Temperature Measurements using the KPCI-3108 with the EXP-1800

CALIBRATION PROCEDURE CAL Contents. Software

Notes on installing and using the OM-USB-5201 and OM-USB-5203 data logging devices

Setup Examples. Thermocouple Card Configuration

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

Datalogging in LabVIEW

Operating Manual. USB-based High-Precision 8-channel Temperature Measurement Module MODEL NO

USB-TEMP-AI. Temperature and Voltage Measurement. User's Guide

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

Ultra-Accurate Measurement for Temperature and Voltage

Temperature Measurement Instruments Ultra-Accurate... by Design

Vernier SensorDAQ User s Manual

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

Lab #4 The Data Acquisition (DAQ) Card. Read Before Coming to Lab: The Data Acquisition (DAQ) Card (from Appendix A)

Contents. Software CALIBRATION PROCEDURE NI TC-4353

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SCC-AO10 Isolated Analog Output Module

E/S/M/B Series Calibration Procedure for NI-DAQ mx

Ultra-Accurate Measurement for Temperature and Voltage

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-4357

The data acquisition components, and their relationship to each other, are shown below.

What s New in Data Acquisition

Data Acquisition Laboratory

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

9933 TableWare User s Guide

NI USB-TC01 Thermocouple Measurement Device

Ultra-Accurate Temperature Measurement Instruments

DT9828. Low-Cost, Isolated, Thermocouple Measurement Module. Overview. Key Features. Supported Operating Systems

Multifunction DAQ Accessory and Cable Selection Guides

USB Multi-sensor Measurement and Data Logger. User's Guide

ProfiPro Distributed PROFIBUS I/O Modules User Manual

NI 6703/6704 Calibration Procedure for NI-DAQ mx

TECH 3821 Lab #2 Relay Driver with Computer Control

Small rectangles (and sometimes squares like this

SCXI -1313A Terminal Block

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

Keysight U2802A 31-Channel Thermocouple Input Device

CALIBRATION PROCEDURE SCXI Contents. Software Requirements. ni.com/manuals

Teaching Computer-Based Data Acquisition and Analysis Research Skills Using LabVIEW

DAQ in MATLAB HANS-PETTER HALVORSEN,

USB-TC. Thermocouple Measurement. User's Guide. October Rev 10A Measurement Computing Corporation

NI USB-622x/625x/628x OEM

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

Labview Lab 2. Vern Lindberg. April 16, 2012

Cube67 - Modular I/O station

NI Technical Symposium ni.com

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

Dept. of Electrical, Computer and Biomedical Engineering. Data Acquisition Systems and the NI LabVIEW environment

last update December 1, 2010 reference smtirin06n page 1/21 SMARTEC INFRARED INTERFACE BOARD SMTIRIN06

User s Guide OM-USB-TEMP-AI. 8 Channel Temperature/Voltage Measurement USB Data Acquisition Module. Shop online at

M Series USB-6221/6225/6229/6251/6255/6259 OEM Devices

Introduction to LabVIEW and NI Hardware Platform

Virtual Instrumentation With LabVIEW

USER MANUAL NI 9755 NI Powertrain Controls CompactRIO NOx Sensor Module Kit

A Review of PC-Based Data Logging and Recording

File (19 inches) for RS3 FIC I/Os (AI/AO) migration toward a new system

High-Temp PRT Module 2561

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

Transcription:

LabVIEW Tutorials T.1 Temperature Measurement and Cold Junction Compensation (CJC) LUMS School of Science and Engineering Umer Hassan & Muhammad Sabieh Anwar

Introduction: In this tutorial we shall learn how to measure temperature using NI DAQ Cards and LabVIEW while employing cold junction compensation in real time. Thermocouples require some form of temperature reference to compensate for the cold junctions. The most common method is to measure the temperature at the reference junction with a direct reading temperature sensor. This process is called cold junction compensation (CJC). Procedure: Follow the following illustrative step by step procedure to measure temperature using thermocouples. Start Measurement & Automation Explorer. Under Configuration, select My System then select Data Neighborhood, following dialog box appears. Click NI DAQmx Global Virtual Channel On the following window, click, Create New NI DAQmx Channel,

On clicking, Create New NI DAQmx Global Virtual Channel, a dialog box appears which asks you whether you want to create or acquire a signal. Select Acquire Signal, and then select Analog Input and then Voltage, as shown in the below picture.

On clicking Voltage, following dialog box appears which asks you which Physical Channel acts as virtual channel. Current SCC 68 connections: PIN 57 (AI 7) is connected to PIN 70 (CJC+) PIN 56 (AI GND) to PIN 71 (AI GND). Thus, on the following dialog box select AI 7 and click on Next.

The dialog box appears which asks you to write a desired name for the global virtual channel. We named RT CJC and then click on Finish.

The following window appears. Make the Terminal Configuration to RSE, under the Settings tab, set the signal Input Range to Max 10 and Min 10. And select Volts as Scaled Units. Click on the Connection Diagram tab, at the lower bottom of the dialog box. It shows you the connection diagram of the existing channel, which is shown below. Make sure the connections on the diagram should be same as of the SCC 68.

Now click on the NI DAQmx Global Channel again, and under the Voltage Input Setup, scroll down Custom Scaling and select Create New. Following Dialog box appears.

Click on Table, the following window asks you to enter the name of the scale, e.g. Steinhart calibration Click Finish, following dialog box appears.

Click on Import, Now we have to import the calibration file (Steinhart.txt), the import file wizard shows you the calibration table as follows,

Click Ok. The table has been added as shown below. Click OK, now the Custom Scaling should read as Steinhart calibration. On the following dialog box, click Save.

A global virtual channel has been created; now close the Measurement & Automation Explorer. Now go to LabVIEW, Open a new VI In Block Diagram, place a DAQ Assistant, the following dialog box appears

Select Acquire Signals, Analog Input, and Temperature and finally select Thermocouple. Select the physical channel, at which you connected the thermocouple, let s say AI 0 Select the channel and click on finish. Following dialog box appears

Under the Thermocouple Setup, set the following parameters as, Signal Input range: The range of the input temperature you are acquiring Scaled Units: The different temperature units (C, F, K) Thermocouple Type: Select the type of the thermocouple which you are using (identified using color codes) CJC Source: Define the CJC source as Constant, Channel, or Built in. For the real time cold junction compensation measurements, define it to Channel. CJC Channel: Select the RT CJC channel which we have just created Acquisition Mode: Select this to Continuous samples.

Click Ok. Place a Graph Indicator at the output i.e. Data of the DAQ assistant and click on Run button. Place a while loop around it to continuously run the file, as shown,

Check the Front Panel.

Graph Indicator shows you the temperature while performing cold junction compensation in real time. Find the average of the acquired temperature for eliminating noise. Important Note: Turn the switch ON labeled as SW1 on SCC 68 Card. The light turned as the switch turns ON. This switch provides the power to the thermistor circuit which is performing the real time cold junction compensation. Enjoy!!!!!!!!