SSA3000X Series Spectrum Analyzer. Quick Guide

Similar documents
SVA1000X Series Spectrum Analyzer. Quick Guide QG0701X-E01A

RIGOL. Quick Guide. DSA1000 Series Spectrum Analyzer. Nov RIGOL Technologies, Inc

2016 SIGLENT TECHNOLOGIES CO.,LTD

22, 2017 RIGOL TECHNOLOGIES, INC.

RIGOL. Quick Guide. DP800A Series Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

Economy Single Channel Output DC Power Supply

XSA1000 Series Spectrum Analyzer Quick Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

DS1000B Series Digital Oscilloscope

99 Washington Street Melrose, MA Phone Toll Free Visit us at

2019 RIGOL (SUZHOU) TECHNOLOGIES INC.

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

USER S MANUAL Linear Programmable DC Power Supply APS

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

DM3058/DM3058E Digital Multimeter

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

VDS Series PC Oscilloscopes Quick Guide

ODP Series Dual Output Linear Programmable DC Power Supply User Manual

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

Bluetooth/USB Data Logger USER S MANUAL. Hantek 365A/B/C/D/E/F V

RIGOL. Service Guide. L-3400 Series Column Oven. Nov RIGOL Technologies, Inc.

2015 SIGLENT TECHNOLOGIES CO., LTD

Spectrum Analyzer GSP-730 QUICK START GUIDE GW INSTEK PART NO. 82SP-73000M01 ISO-9001 CERTIFIED MANUFACTURER

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

1-36V, 0-3A DC Power Supply

ODP Series Linear Programmable DC Power Supply User Manual

Model 2380 Rack-Mount Kit

BC-3OOO USER S MANUAL. Scale Printer ISHIDA CO., LTD. WARNING

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

ETHOS Auto Ranging Digital Multimeter

Model 2380 Rack-Mount Kit

HV-CS kv Edge Mount Triaxial Jack

ODP3031 Linear Programmable DC Power Supply User Manual

RIGOL. User s Guide. DP1116A Programmable DC Power Supply. Mar RIGOL Technologies, Inc.

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

RIGOL User s Guide. DL3000 Series Programmable DC Electronic Load. Feb RIGOL TECHNOLOGIES, INC.

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Model 7705 Control Module

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

AD-400. CD Player with USB/SD and FM Tuner. Item ref: UK User Manual

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Universal AC Power Source + AC Power Analyzer

Configurable Network Paging Console. Product Instructions. Model: X-NPMI

User Guide True RMS Multimeter Extech EX205T

Manual. Dimmer DMD-12-2

7032 Digital-Analog Multimeter

General Warranty. For more details, please refer to the user manual, it can be downloaded at

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

9040/9040UK. Users Manual. Phase Rotation Indicator

2260B-RMK-Series Rack Mount Kit

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Thin clients JC500X - 1 Reference guide

Digital Overhead Stirrer

DS-2 RF DMX dimmer. user manual

SPD1000X Series Programmable DC Power Supply. DataSheet

Keysight M8000 Series BER Test Solutions

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

PicoVNA. USB vector network analyzer. Quick Start Guide

2016 SIGLENT TECHNOLOGIES CO., LTD

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

General Warranty. For more details, please refer to the user manual, it can be downloaded at

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

STYLITIS-POWER OPERATOR S GUIDE

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

KHT 6000 C HV-Probe Calibrator. Instruction Manual

User s Guide. 600A AC Clamp Meter. Model 38387

KDC-C712 KDC-C662 KDC-C462

User's Guide. Extech AM A AC Analog Clamp Meter

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers

2014 SIGLENT TECHNOLOGIES CO., LTD

UP-1-1 Channel Dimmer dimmer pack. user manual

PicoScope 9000 Series PC Sampling Oscilloscopes. Quick Start Guide

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

High Precision Quad Output DC Power Supply

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series

Antenna Distributor ORDERCODE D1444

Pure sine wave inverter. Product Manual

TA330 HAND HELD AUTOMOTIVE SINGLE CHANNEL OSCILLOSCOPE AND MULTIMETER

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operating Instructions

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Series 370 S SoftwSystem are Qui Switch/Mult ck Start G imeter uide Quick Start Guide

DS-1H05 Ethernet-over-Coax Extender. User Manual

P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31

UP-1-1 Channel Dimmer. User manual. dimmer pack

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

AC/DC Current Probe Model SL201

Operating Instructions

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Transcription:

SSA3000X Series Spectrum Analyzer Quick Guide

Copyright Information SIGLENT TECHNOLOGIES CO., LTD. All Rights Reserved. Information in this publication replaces all previously corresponding material. SIGLENT reserves the right to modify or change parts of or all the specifications or pricing policies at company s sole decision. Any way of copying, extracting or translating the contents of this manual is not allowed without the permission of SIGLENT.

General Safety Summary Carefully read the following safety precautions to avoid any personal injury or damage to the instrument and any products connected to it. To avoid potential hazards, please use the instrument as specified. Use Proper AC Power Line Only the power cord designed for the instrument and authorized by local country should be used. Ground the Instrument The instrument is grounded through the protective earth conductor of the power line. To avoid electric shock, please make sure the instrument is grounded correctly before connecting its input or output terminals. Connect the Probe Correctly If a probe is used, do not connect the ground lead to high voltage since it has isobaric electric potential as the ground. Look Over All Terminals Ratings To avoid fire or electric shock, please look over all ratings and sign instruction of the instrument. Before connecting the instrument, please read the manual carefully to gain more information about the ratings. Use Proper Overvoltage Protection Make sure that no overvoltage (such as that caused by a thunderstorm) can reach the product, or else the operator might be exposed to danger of electrical shock. Electrostatic Prevention Operate the instrument in an electrostatic discharge protective area environment to avoid damages induced by static discharge. Always ground both the internal and external conductors of the cable to release static before connecting. Maintain Proper Ventilation Inadequate ventilation may cause increasing of the instrument s temperature, which will eventually damage the instrument. So keep well ventilated and inspect the intake and fan regularly. Avoid Exposed Circuit or Components Do not touch exposed contacts or components when the power is on. Do Not Operate Without Covers Do not operate the instrument with covers or panels removed. Use Only the Specified Fuse. Keep Product Surfaces Clean and Dry To avoid the influence of dust and/or moisture in the air, please keep the surface of the device clean and dry. Do Not Operate in Wet Conditions In order to avoid short circuiting to the interior of the device or electric shock, please do not operate the instrument in a humid environment. Do Not Operate in an Explosive Atmosphere In order to avoid damage to the device or personal injury, it is important to operate the device away from an explosive atmosphere.

General Safety Summary Safety Terms and Symbols Terms on the product. These terms may appear on the product: DANGER Indicates direct injuries or hazards that may happen. WARNING Indicates potential injuries or hazards that may happen. CAUTION Indicates potential damages to the instrument or other property that may happen. Symbols on the product. These symbols may appear on the product: Warning Hazardous Voltage Protective Earth Ground Earth Ground Chassis Ground

General Care and Cleaning Care Do not store or leave the instrument in direct sunshine for extended periods of time. Notice: To avoid damages to the instrument, please do not leave it in fog, liquid, or solvent. Cleaning Please perform the following steps to clean the instrument regularly according to its operating conditions. 1. Disconnect the instrument from all power sources, and then clean it with a soft wet cloth. 2. Clean the loose dust on the outside of the instrument with a soft cloth. When cleaning the LCD, take care to avoid scratching it. Notice: To avoid damages to the surface of the instrument, please do not use any corrosive liquid or chemical cleanser. Make sure that the instrument is completely dry before restarting it to avoid short circuits or personal injuries.

General Inspection 1.Inspect the shipping container Keep the damaged shipping container or cushioning material until the contents of the shipment have been completely checked and the instrument has passed both electrical and mechanical tests. 2. Inspect the instrument If the instrument is found to be damaged, defective or fails in electrical or mechanical tests, please contact SIGLENT. 3. Check the accessories Please check the accessories according to the packing list. If the accessories are incomplete or damaged, please contact your SIGLENT sales representative.

Appearance and Dimension Figure 1 Front View Figure 2 Top View

Adjust the Supporting Legs Adjust the supporting legs properly to use them as stands to tilt the Spectrum Analyzer upwards for stable placement as well as easier operation and observation of the instrument. Before adjusting After adjusting

Connect to AC Power Supply The Spectrum Analyzer accept 100-240V, 50/60/440Hz AC power supply. Please use the power cord provided as accessories to connect the instrument to the power source as shown in the figure below.

General Description SSA3000X series spectrum analyzer has a frequency range from 9 khz up to 2.1 GHz/3.2 GHz. It is lightweight, small and precise, offering a user friendly interface, clear display with plenty of RF measurement functions. The product can be used for research and development, education, production, maintenance and other relevant applications. The Front Panel 1 3 2 5 4 6 11 10 9 8 7 1 User Graphical Interface 4 Numeric Keyboard 7 RF Input 10 USB Host 2 Menu Control Keys 5 Knob 8 TG Output 11 Power Switch 3 Function Keys 6 Arrow Keys 9 Earphone interface

Details of the Various Functions: Frequency: Sets the Center Freq\Start Freq\Stop Freq\Freq Step Span: Sets the Span\Full Span\Zero Span\Zoom In\Zoom Out\Last Span Amplitude: Used to Set the REF Level\Attenuator\Preamp\Amplitude Auto Tune: Automatically sets the optimal parameters according to the characteristics of the signal BW: Used to adjust the RBW,VBW,VBW/RBW Rate,Average Type (Logpower\Power\Voltage) Trace: Selects Trace\Trace setup\trace math Sweep: Selects the Sweep time\sweep Rule\Sweep Mode Detect: Selects the Detector type Trigger: Used in Selecting the Free Trigger\Video Trigger\External Trigger Limit: Sets the Pass\Fail Limit TG: Sets the TG Level\TG Level offset\normalize Demod: Used to set the Parameters of the AM and FM Marker: Used to Select the Mark Trace and Marker math Marker : Sets all types of Markers to Freq Marker Fn: Selects the Noise Marker\N db BW\Freq Counter\Read out of Freq Peak: Searches for the Peak Signal and Counts the Peak Frequency

Meas: Selects the Channel Power\ACPR\Occupied BW\T-Power Meas Setup: Used to Choose the Parameters Details of Channel Power\ACPR\Occupied BW\T-Power System: Selects the Language\Power on/preset\interface\calibration\system information\data&time\self Test Mode: Selects the opretion Mode Display: Used to Adjust the Grid Brightness\Display Line File: Use to Select the File system Preset: Sets the system to default status Couple: Used to Select the RBW\VBW\Attenuator\Freq Step\Sweep time mode Help: Help Information Switch Save: Save Shortcut Key

The Rear Panel 1 2 3 4 5 6 1 Handle 2 USB Device 3 LAN Interface 4 10MHz REF Input 5 10MHz REF Output 6 Trigger In 7 Safety Lock Hole 8 AC Power Socket 8 7

Opertion Notices 1. RF INPUT WARNING To avoid damage to the instrument, make certain that the input signal to the RF input port does not contain more than 50 Volts DC. The AC (radio frequency) input signal component should not exceed a maximum continuous power level of +30dBm. 2. TG OUTPUT WARNING To avoid damage to the tracking generator, The reverse DC voltage must not exceed 50V

User Graphical Interface 1 2 6 3 7 5 4 1 SIGLENT LOGO 2 4 5:Parameters setting area 3 Menu setting area 6 Active parameter 7 Display area

For More Product Information You can obtain the instrument information including model, serial number as well as hardware and software version numbers through System Information. For more information of this product, please refer to the following manuals (provided in the CD in the accessories; you can also download them from the SIGLENT Web site): SSA3000X Series User Manual: provides detailed introductions of the functions of this product; SSA3000X Series Programming Guide: provides detailed introductions of the SCPI commands and programming of this product; SSA3000X Series Datasheet: provides the main characteristics and specifications of this product;

Contact us SIGLENT TECHNOLOGIES CO., LTD. Address:3/F, building No.4, Antongda Industrial Zone, 3rd Liuxian Road, Bao an District, Shenzhen, P.R.C. Tel:+86-755-36615186 E-mail:sales@siglent.com Http://www.siglent.com

www.siglent.com