HD Flex Zero RU Cassette Holder and Bracket

Similar documents
OptiCom Adapter for HD Flex Cassettes

G12/G12x USER S MANUAL

SYSTIMAX 360 ipatch 96F LC Upgrade Kit

with Fiber Management Bar

Wall Mounted Building Entrance Enclosure Instructions

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Peel/Rewind Upgrade Kit

System Storage EXP3000 Rack Installation Instructions

Rack Installation Instructions

3 Angled Connector Housing (MC) Installation

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

High Density PEACOC v. 3.0 Fiber Patch Panel& FleT

Internal tray pulls out towards the user, providing room to manage the fiber cable behind the fiber adapter panels or cassettes.

Fuser. Figure Remove the fuser assembly (1 of 2) 184 Chapter 5 Removal and replacement ENWW

Service & Maintenance

Assembly and Setup Manual

Rack Installation Instructions

Cable Routing Procedures for Dell PowerEdge R630 Systems

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Installation

Replacing the SATA PCI Controller Card

IBM. Rack Installation Instructions

Rack Installation Instructions

Rack Installation Instructions

2 visit

7403 K321. Display Wall Mount. Kit Instructions. Issue A

7409 K570. Generic Pinpad Mount. Kit Instructions. Issue B

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

HP EVA4400 M6412 drive enclosure

Installation Job Aid for Avaya Virtual Services Platform 8400

Removing and Replacing Parts

APES-14 HD-6500 & HD-7000 Version Operator s Training Manual

Installing the Server into a Rack

Removal and Installation 8

Keypad Lock. Operation and Service Manual. Order parts online

TDM-100/150 TO NMD-50 CONVERSION PROCEDURES RL5000

PACSystems* RX3i IC695ACC650

FreeNAS Mini and Mini XL Network Upgrade Kit

Pretium Rack-mountable 1U Housing Hardware

Fiber Management Tray (FMT) User Manual

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System

120Ra-1 Pentium III Processor Installation Insert

V.I.A. - Monitor Shroud

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Removing and Replacing Chassis Components

System Storage DS3950 Quick Start Guide

TrueNet 1U and 2U Fiber Panel Installation and Cable Routing Instructions

Floor Standing Pedestal

Megatouch FORCE Monitor Chassis Board Replacement

The Drivers Behind High-Density Systems

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

Vertiv Local Rack Access 18.5" LED LCD Console

XCM8800 PSU Cover. Installation Guide. 350 East Plumeria Drive San Jose, CA USA. May v1.0

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website:

Dell Inspiron N5110 Service Manual

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

Installation Guide. Copyright 2005 MSI Computer Corp.

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Dual Drive Installation

7403-K131/132/133/K138. Memory Modules. Kit Instructions. Issue C

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Maintaining E-Series Routers

LASERJET ENTERPRISE MFP M630

Installation Guide Philips MP20/30/40/50/60/70 IntelliVue M-Series Arm Rail Mount Kit

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

User Guide OMNI 97. For ipad 9.7, ipad Pro 9.7 and ipad Air ADVANCE RELEASE! (Product coming F/W 2017) [ Issued

Assembly and Setup Manual

Central Processing Unit (CPU) Replacement

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness

Adding or Replacing a PCI Card

Oracle <Insert Picture Here>

HP ProLiant DL165 G7 Server

Rear Consumer LCD Hinge Assembly Large Displays

Removal and Installation8

Assembly Instructions for #5630 Medication PalWOW

Table of Contents Chapter 3 Installing the Switch

Quick Start Guide. AR530&AR550 Series Industrial Switching Routers. Issue: 07 ( ) Part number: HUAWEI TECHNOLOGIES CO.

Dell PowerEdge R940. Upgrading the dual processor to quad processor system

2T-RMSMC System Management Station Kit Installation Guide

Two Rack Unit (2RU) Fiber Management Tray (FMT) User Manual

Dell Latitude C800 Service Manual

Written By: Teren Wallace

HAW-SIBU. Rack Installation Guide. Version 1.0.1

A-MOD DESKTOP OWNER S MANUAL

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

Installing IDS-4235 and IDS-4250

Replacement Instructions. Backplane PCA for the HP Router 650

CARD PRINTER PRINTHEAD REPLACEMENT INSTRUCTIONS

Cisco TelePresence VX Clinical Assistant TM

Ryobi 12 in. Sliding Compound Miter Saw With Laser Model No. TSS120L Repair Sheet

DATASHEET REV.1.0 Data center System. Datasheet. 2RU Slide-Out Fiber Enclosure Unloaded #51610 FHD-2UFCE. Description. Application

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

5000, 7000 Series StorSimple Appliance. Rack Installation Guide

CHASSIS INSTALLATION GUIDE

Model GS7000 Node Expanded Fiber Tray Installation Instructions

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C)

TDM To MiniMech conversion ProceDure

LENS REPLACEMENT PROCEDURE

Transcription:

HD Flex Zero RU Cassette Holder and Bracket Part Numbers: FLEX-0RUBR**, FLEX0RUCH** Panduit Corp. 2016 INSTALLATION INSTRUCTIONS The Zero RU Cassette Holder and Bracket are designed to mount on the side of the cabinet rails. They are available in 4-port, 6-port, and 12-port cassette configurations. FLEX-0RUBR04 FLEX-0RUBR06 FLEX-0RUBR12 FLEX-0RUCH04 FLEX-0RUCH06 FLEX-0RUCH12 WARNING: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. DO NOT LOOK DIRECTLY INTO THE END OF THE CONNECTOR. DO NOT INSPECT WITH MAGNIFYING DEVICES. MAINTAIN DUST CAPS ON UNMATED CONNECTORS. CAUTION: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Consult the manufacturer s cable specification sheet for the specific cable in use. Follow TIA/EIA-568-A, 569, 606, and 607 installation guidelines where applicable. ASSEMBLY VIEW (FLEX-0RUBR06 shown) Label Card Holder Label Card HD Flex Zero RU Cassette Holder and Bracket Assembly Package Contents: (FLEX-0RUBR04, FLEX-0RUBR06, FLEX-0RUBR12) (1) HD Flex Zero RU Cassette Holder Assembly (includes Mounting Bracket and Label Card Holder) (1) HD Flex Zero RU Adapter Plate (4) M5 x 0.8 x 12 Self Tapping Screw (4) #12-24 x 0.5 Screw (4) M6 x 1.0 x 15mm Screw (4) #10-32 Hex Nut (1) Label Card (2) Laser Warning Label (1) Fiber Caution Label HD Flex Zero RU Cassette Holder Package Contents: (FLEX-0RUCH04, FLEX-0RUCH06, FLEX-0RUCH12) Cassette Holder Assembly (1) HD Flex Zero RU Cassette Holder #10-32 Hex Nut Mounting Bracket Rail Adapter Plate Figure 1 Page 1 of 10

Mounting on the side of a Panduit network cabinet: ASSEMBLY VIEW (FLEX-0RUBR06 shown) HD Flex Zero RU Using four (4) M5 self-tapping screws, attach the HD Flex Zero RU Cassette Holder and Bracket to the side of the network s cabinet vertical post. Note: The HD Flex Zero RU cannot be attached to vertical posts with air flow control panels attached. Network cabinet vertical post Mounting on the side of a Panduit server cabinet: Figure 2 ASSEMBLY VIEW (FLEX-0RUBR06 shown) Using two (2) M5 self-tapping screws, attach the HD Flex Zero RU Cassette Holder and Bracket to the side of the server s cabinet rail. HD Flex Zero RU server cabinet rail Figure 3 Page 2 of 10

Mounting the Zero RU to the front of the equipment rack: The HD Flex Zero RU can be mounted onto a previously installed equipment rack using existing screws and the HD Flex Rail Adapter Plate. The HD Flex Zero RU can be mounted on either the left or the right rail of the equipment rack. 2 1. Remove screws from existing equipment that align with mounting holes in the HD Flex Zero RU Rail Adapter Plate. 2. Loosen screws from existing equipment that align with the slits in the HD Flex Zero RU Rail Adapter Plate. 3. Slide the HD Flex Zero RU Rail Adapter Plate under the loose screws. 4. Replace and tighten the removed screws. 3 1 Rail Adapter Plate front of equipment rack Figure 4 5. Attach the HD Flex Zero Cassette Holder assembly to the HD Flex Zero Rail Adapter Plate using four (4) #10-32 hex nuts Cassette Holder Assembly Rail Adapter Plate Figure 5 Page 3 of 10

Mounting the HD Flex Zero RU to the back of the equipment rack: 1 2 Rail Adapter Plate Cassette Holder Assembly If the space in front of the equipment rack is inadequate, the HD Flex Zero RU can be mounted to the back surface of the equipment rack. 1. Attach the HD Flex Zero RU Rail Adapter Plate to the back surface of the equipment rack using four (4) screws. 2. Attach the HD Flex Zero RU Cassette Holder assembly to the HD Flex Zero RU Rail Adapter Plate using four (4) #10-32 hex nuts. back of equipment rack Cassette Assembly (sold separately): Figure 6 First, attach trunk cabling to the rear port of the cassette or FAP to be installed. Note the polarity label on the cassette and orient properly as needed. To install cassettes, insert into slot and push forward until it snaps into place. Polarity Label Figure 7 Page 4 of 10

Cassettes can be removed from the front, as needed, for replacement or migration. Disconnect patch cords from the front of the cassette. Press the latch away from the cassette and pull the cassette forward. Once the cassette is pulled past the latch, the cassette can be completely removed. Disconnect the trunk cable from the rear of the cassette and connect to the rear of the replacement cassette. Figure 8 Re-install the cassette or MPO FAP opposite the way it was removed. Align the rear of the cassette or MPO FAP in the opening and push inward until the cassette snaps into place (for cassette changes). Figure 9 Cassettes can be removed from the back, as needed, for replacement or migration. Disconnect patch cords from the front of the cassette. Press the two latches on the back of the cassette inward, then with the latches squeezed together, pull the cassette out through the back. Figure 10 Page 5 of 10

Port 1 If migrating to an MPO FAP, connect the MPO trunk cable to the left most position, port 1. MPO FAP Installing Additional Trunks: 1 6 Figure 11 To install additional trunks, remove the MPO FAP through the back of the HD Flex Zero RU and attach the trunks as needed. 1. Insert diagonally until rear of boot is just past the rear post. Installing Additional Cassette Holders: 1 2 2. Lift cable over post. Figure 12 If the MPO FAP cannot be removed through the back, due to lack of slack in the front cables, insert the MPO connector into the rear of the FAP diagonally between the posts. Push the connector in until the rear of the boot just passes the rear post and lift the cable over the post to "hold" the connector in place. Pull the FAP with the "held" MPO trunk out through the front of the HD Flex Zero RU. Remove the dust cap and connect the MPO to the appropriate port of the FAP. FAP can accommodate "holding" up to 3 MPO connectors at a time. The cassette holders are designed to latch to one another and can be added or removed as needed. For most applications, a maximum of four (4) cassette holders can be latched together. To remove the label card holder, depress the two locking latches of the cassette holder below it. locking latch Figure 13 Keeping the locking levers depressed, slide the label card holder back out of the four (4) engagement hooks of the cassette holder below it. engagement hooks Figure 14 Page 6 of 10

Lift the label card holder away from the casette holder. Label Card Holder Cassette Holder Figure 15 Place the additional cassette holder (top) over the existing cassette holder (bottom). Figure 16 openings Verify that the four engagement hooks in the bottom cassette holder are aligned with the four openings in the top cassette holder. engagement hooks Press Here Figure 17 Force the two cassette holders together by applying pressure near the outer centers of the top cassette holder. (See Figure 17A).) Slide the top cassette forward until the locking latches of the bottom cassette holder click into the locking position. Re-install the label card holder over the top cassette holder using the same procedure as for cassette holder installation. Figure 17A Note: If required, multiple stacked cassette holders can be separated using the same procedure as for removing the label card holder. Page 7 of 10

Reconfiguring the port configuration on the Zero RU Cassette Holder: Select the rail to be removed. Grip the end of the rail and pull it away from the cassette holder. rail Figure 18 While continuing to apply pressure on the rail being removed, pull the rail forward. As the rail begins to move, it will disengage from the tray and be free to remove completely. rail Figure 19 To install the rail into the cassette holder, align the rail between triangular cutouts and reverse the removal process. The posts on the bottom of the rail will drop into the cutouts of the cassette holder. As the rail is pushed toward the back of the cassette holder, the posts will engage the cassette holder. Once the rail is fully re-inserted, the front of the rail will snap into position. Pull forward on the rail to ensure it is properly installed. triangular cutout rail Figure 20 Page 8 of 10

Zero RU Casette Holder Port Configurations (Only cassette holder trays are shown for clarity) 6-Port Configuration: 1 black removable rail per cassette holder Figure 21 4-Port Configuration: 2 white removable rails per cassette holder Figure 22 12-Port Configuration: No removable rails installed in cassette holder Figure 23 Page 9 of 10

Labeling: Labeling options for the HD Flex Zero RU allow for identification to follow the EIA 606-B labeling standards. Panduit labels, used in conjunction with Panduit Easy-Mark Labeling Software, simplifies label creation and allows for ease of editing and label replacement when necessary. The labeling layout is shown in Figure 24. Panduit label part #C061X030FJJ can be used for single port identification, Panduit label part #C125X030FJJ can be used for 2-port identification, Panduit label part #C252X030FJJ can be used for 4-port identification, or Panduit label part #C379X030FJJ can be used for 6-port identification. Mounting Surface Panduit Part # C061X030FJJ Panduit Part # C125X030FJJ Panduit Part # Panduit Part # C252X030FJJ C379X030FJJ Figure 24 The label card coincides with the port labeling as shown in Figure 25. Cassette holder 1 is the closest to the mounting surface (the layout shows ports 1-12 on the first cassette holder, ports 13-24 on the second cassette holder, etc). The label card should be stored in the label card holder. Mounting Surface Figure 25 Panduit Label Part Numbers Part Number C061X030FJJ C125X030FJJ C252X030FJJ C379X030FJJ Description White, adhesive polyolefin label, 1-port identifier White, adhesive polyolefin label, 2-port identifier White, adhesive polyolefin label, 4-port identifier White, adhesive polyolefin label, 6-port identifier For Instructions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp www.panduit.com Page 10 of 10 E-mail: techsupport@panduit.com Phone: 866-405-6654