MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Similar documents
C1U-W Tx Series AC/DC Front End Power Supply

Consult with factory for availability INPUT CHARACTERISTICS. Consult with factory for details and availability OUTPUT CHARACTERISTICS

C1U-W Tx Series

D1U3CS-D HxxC Series 81mm 1U Front End DC-DC Power Supply Converter

60 Watt Medical (MWLT)

MVAC400 Series 400W 3" x 5" High Density AC-DC Power Supply Converter

D1U2-D HA4C 54mm 1U Front End DC-DC Power Supply Converter

MVAC400 Series 400W 3" x 5" High Density AC-DC Power Supply Converter

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

D1U3CS-W HxxC Series

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

Safety Standards. Model Number: Unit Weight:

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

275 Watt Medical Ultra low profile

D1U4CS-W HxxC Series AC/DC Front End Power Supply

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

ORDERING INFORMATION SEE PAGE 6

CINT W Triple Output Industrial Series

ORDERING GUIDE. Model Number Natural Convection Cooling Forced Air Cooling MVAC400-24AFJT* # JST : B2P3-VH Series AC Input Connector

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Recommended Alternative: PQC250 Series ORDERING GUIDE. Model Number Natural Convection Cooling Forced Air Cooling OUTPUT CHARACTERISTICS.

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

Cool. NFF Series. CoolX600 NFF Series. NFF Series; No Fan Featured

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Safety Standards. Model Number:

Universal Power Supplies

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

D1U-W Hx Series

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Industrial Power Supplies

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

D1U5CS-H HA4C

D1U-W Hx Series

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

Safety Standards. Model Number:

Safety Standards. Model Number:

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Enclosed Power Supplies

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Safety Standards. Model Number:

Output Voltage* (nom.)(adjustable)

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

78xxSR Series 3.3V/5V/12V Outputs High-Effi ciency Switching Regulators with LM78xx Pinouts

Safety Standards. Model Number:

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

LED Indicator. Class I

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

NMUSBEVAL Powered Dual Port USB Data Isolator

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Safety Standards. Model Number:

Constant Voltage Mode

C B. Models. Operating up to 5000m altitude 5 year product warranty

Features. Applications and Benefits TRC ELECTRONICS, INC

Output Voltage* (nom.)(adjustable)

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

PMT. Safety Standards. Model Number:

500Watts Medical Single Output

PJT Highlights & Features

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

EMH Series. 250 W & 350 W Forced-cooled. Industry Standard 3 x 5 x 1.43 Format. IT & Medical (BF) Approvals. 80 V VAC Operation

Transcription:

www.murata-ps.com MVAD040 Series DESCRIPTION The MVAD040 series switching power supplies utilize advanced component and circuit technologies to deliver high effi ciency. Designed for Medical, Telecom, and Industrial applications to satisfy 1U height design considerations, the MVAD040 Series measures only 2.0" x 4.0" x 1.3". All models offer universal AC input and compliance to worldwide safety and EMC standards. FEATURES ITE (2nd Ed.) and Medical (3rd ed.) MOPP safety approved 30-40W compact high density 2" x 4" standard footprint High effi ciency up to 89% Universal AC input Low profi le - 1U package Convection-cooled operation up to 40W with 5000m altitude RoHS compliant UL Class I and II approved Less than 0.3W no load input power with ErP/Energy Star requirement average efficiency>85.3% (24V and 48V) Available now at ORDERING GUIDE Model Number Natural Convection Cooling Main Output (V1) MVAD040-05 30W 5V MVAD040-12 12V MVAD040-24 40W 24V MVAD040-48 48V INPUT CHARACTERISTICS Input Voltage Operating Range Single phase 90 120/230 264 Vac DC 120 300 Vdc Input Frequency 47 50/60 63 Hz Turn-on Input Voltage Input rising at full load 50 70 Turn-off Input Voltage Input falling at full load 50 70 Vac Input Current 90Vac input, full load 0.9 A Inrush Current At 264Vac, at 25 C cold start OUTPUT CHARACTERISTICS Main Output Model Number Load Current Peak Load Voltage (V1) 3 Load Capacitance Line, Load, Cross Regulation 60 Apk Typical Effi ciency @230Vac full load MVAD040-05 5V 0 to 6A 0 to 1200μF ± 2% 80% MVAD040-12 12V 0 to 3.34A 5.0A 0 to 680μF ± 2% 87% MVAD040-24 24V 0 to 1.67A 2.5A 0 to 330μF ± 2% 88% MVAD040-48 48V 0 to 0.84A 1.25A 0 to 220μF ± 2% 89% Main Output Characteristics (all models) Parameter Conditions Min. Max. Units Transient Response (MVAD040-05 only) ± 8 50% load step, 1A/μsec slew rate Transient Response (all other models) ± 5 % Settling Time to 1% of Nominal 200 μsec Turn On Delay After application of input power 1 sec Output Voltage Rise Monotonic, 0 to 100% load 50 msec Setpoint Accuracy 120Vac, 40W, 25 C ± 0.5 % Output Holdup, MVAD040-05 only 115Vac, 100% load 20 msec Output Holdup, all other models 115Vac, 100% load 15 msec Temperature Coeffi cient 0.02 %/ C Ripple Voltage & Noise 1 1 % 1. Ripple and noise are measured with 0.1 μf of ceramic capacitance and 47 μf of electrolytic capacitance on each of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial cable with 50ohm scope termination is used. 2. Unless otherwise specifi ed all readings are taken at 120Vac input and 25 C ambient temperature. 3. Peak current lasting <15 seconds with a maximum 10% duty cycle and with an average output power of 40W. For full details go to www.murata-ps.com/rohs CB Test Certificate and Test Report MVAD040.B01 Page 1 of 6

ENVIRONMENTAL CHARACTERISTICS Storage Temperature Range -40 85 Operating Temperature Range See thermal derating curves -20 70 C Start up -20 Operating Humidity Non-condensing 10 95 % Operating Altitude For Class I ITE Equipment deployment -200 5000 Other -200 2000 m MTBF Telcordia SR-332 M1C3 25 C 1M Hours Shock Operating, IEC60068-2-27, half-sine 5G, 6ms, 3 times per face, 6 faces Non-operating, IEC60068-2-27, half-sine, 30G, 18ms, 3 times per face, 6 faces Vibration Safety Warranty Outside Dimensions Weight Operating, IEC60068-2-6, 1.0G, 10-150Hz, 10minutes per axis, on all 3 axes Non-operating, IEC60068-2-6, 2.0G, 10-150Hz, 10minutes per axis, on all 3 axes IEC60950-1:2005 (2nd Edition); Am1:2009 UL60950-1 2nd Edition,2011-12-19, CSA C22.2 No. 60950-1-07, 2nd Edition,2011-12 EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011 IEC60601-1:2005 + CORR.1(2006) + CORR.2(2007) ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP CE Marking per LVD 2 years 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) 0.28lbs (127g) typical (MVAD040-05 only) 0.27lbs (123g) typical (all other models) PROTECTION CHARACTERISTICS Overvoltage Protection Latching (60% load) 110 160 %V1 Overcurrent Protection, MVAD040-05 only Hiccup mode 110 160 %A Overcurrent Protection, all other models Hiccup mode 170 240 %A ISOLATION CHARACTERISTICS Primary to Earth Ground (1xMOPP) 1500 Isolation Primary to Secondary (2xMOPP)4 4000 Vac Secondary to Earth Ground 500 Vdc Leakage Current (under normal conditions) 240Vac, 60Hz, 25 C 300 264Vac, 60Hz, 25 C 350 μa Touch Current 264Vac, 60Hz, 25 C 100 EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics IEC/EN 61000-3-2 Class A Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Conducted Emissions EN 55022 Class B, Class A (at Class II equipment) FCC Part 15 Class B, Class A (at Class II equipment) ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion A Radiated Field Immunity IEC/EN 61000-4-3 Level 2, Criterion A Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 3, Criterion A Surge Immunity IEC/EN 61000-4-5 Level 4, Criterion A RF Conducted Immunity IEC/EN 61000-4-6 Level 2, Criterion A Magnetic Field Immunity IEC/EN 61000-4-8 Level 2, Criterion A Voltage dips, interruptions IEC/EN 61000-4-11 Level 3, Criterion B 4. At class I equipment. MVAD040.B01 Page 2 of 6

EMI CONSIDERATIONS MVAD040 Series For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with safety standards, this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the standalone power supply to comply with EN55022 class A radiated emissions. Radiated emission results vary with system enclosure and cable routing paths. SAFETY CONSIDERATIONS 1. This power supply is a component level power supply intended for use in class I or class II applications. Secondary ground traces need to be suitably isolated from primary ground traces when used in class II applications. 2. When the power supply is used in class II equipment, all ground traces and components connected to the primary side are considered primary for spacing and insulation considerations. 3. Double pole/neutral fusing. PERFORMANCE DATA 88 86 84 82 80 78 76 74 72 70 68 MVAD040-05 E ciency (%) 0 1 2 3 4 5 6 95 93 91 89 87 85 83 81 79 77 75 MVAD040-12 E ciency (%) 0 0.5 1 1.5 2 2.5 3 3.5 95 93 91 89 87 85 83 81 79 77 75 MVAD040-24 E ciency (%) 0 0.3 0.6 0.9 1.2 1.5 1.8 Inrush waveform ( 25 C) 95 93 91 89 87 85 83 81 79 77 MVAD040-48 E ciency (%) 75 0.0 0.2 0.4 0.6 0.8 1.0 Output power (W) 45 40 MVAD040-12/24/48 Thermal Dera ng 35 30 MVAD040-05 Thermal Dera ng 25 20 15 10 5 0-20 -10 0 10 20 30 40 50 60 70 80 Ambient temperature ( C) MVAD040.B01 Page 3 of 6

MECHANICAL DIMENSIONS MVAD040-05 ONLY All dimensions in inches (mm). tolerance is +/-0.02 (0.5) Mounting holes H1 and H2 should be earth-grounded for EMI purpose Mounting holes H2 is earth ground connection This power supply requires mounting on standoffs minimum 0.2' (5.0) in height Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS PIN Description Mating Housing Crimp terminal/pins Input Connector CN1 : Molex 26-62-4030 1 AC Line (V-) Molex 09-50-8031 with locking ramp 3 AC Neutral (V+) Spade Connector: #250 GND Earth Ground Output Connector CN2 : Molex 26-60-4040 1, 2 V1 Molex 09-50-8041 with locking ramp 3, 4 DC Return MVAD040.B01 Page 4 of 6

MECHANICAL DIMENSIONS MVAD040-12 ONLY Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) All dimensions in inches (mm). tolerance is +/-0.02 (0.5) Mounting holes H1 and H2 should be earth-grounded for EMI purpose Mounting holes H2 is earth ground connection This power supply requires mounting on standoffs minimum 0.2' (5.0) in height INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS PIN Description Mating Housing Crimp terminal/pins Input Connector CN1 : Molex 26-62-4030 1 AC Line (V-) Molex 09-50-8031 with locking ramp 3 AC Neutral (V+) Spade Connector: #250 GND Earth Ground Output Connector CN2 : Molex 26-60-4040 1, 2 V1 Molex 09-50-8041 with locking ramp 3, 4 DC Return MVAD040.B01 Page 5 of 6

MECHANICAL DIMENSIONS MVAD040-xx 24V and 48V MODELS All dimensions in inches (mm). tolerance is +/-0.02 (0.5) Mounting holes H1 and H2 should be earth-grounded for EMI purpose Mounting holes H2 is earth ground connection This power supply requires mounting on standoffs minimum 0.2' (5.0) in height Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS PIN Description Mating Housing Crimp terminal/pins Input Connector CN1 : Molex 26-62-4030 1 AC Line (V-) Molex 09-50-8031 with locking ramp 3 AC Neutral (V+) Spade Connector: #250 GND Earth Ground Output Connector CN2 : Molex 26-60-4040 1, 2 V1 Molex 09-50-8041 with locking ramp 3, 4 DC Return Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy. Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. ( Murata ) makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify Murata, its affi liated companies, and its representatives against any damages arising out of the use of any Murata products in safety-critical applications. Specifi cations are subject to change without notice. 2014 Murata Power Solutions, Inc. MVAD040.B01 Page 6 of 6