CLEAN ROOM PANEL - CRP5

Similar documents
RMS WIRELESS MINI LOGGER

Intelligence. humidity and temperature probes. Introducing AirChip Digital Technology.

REFERENCE GENERATOR FOR CALIBRATION OF HUMIDITY AND TEMPERATURE INSTRUMENTS

CRP5 Clean Room Panel. Instruction Manual

CRP5 Clean Room Panel. Instruction Manual

PCD DIGITAL Differential pressure probe

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

Humidity goes Digital

Avoid experiments in monitoring important parameters. Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries

HygroFlex HF7 Humidity Temperature Transmitters. User Guide

HygroClip DIGITAL Humidity and temperature probe

Data logger systems from ROTRONIC

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

HygroFlex HF3 Transmitters. User Guide

HygroFlex HF7 Humidity Temperature Transmitters. User Guide

Rotronic s Universal Monitoring System: RMS

Main catalogue. Measurement solutions for multiple parameters HUMIDITY TEMPERATURE CO2 DIFFERENTIAL PRESSURE PRESSURE FLOW WATER ACTIVITY DEW POINT

Measurement solutions for multiple parameters

Humidity Temperature Transmitter User Guide

HygroFlex HF3 Transmitters and Thermohygrostats: User Guide

HygroFlex TF5 Temperature Transmitter. User Guide

RMS Mini Wireless Data Logger

2016 ROTRONIC AG Bassersdorf Switzerland. RMS Data Logger

PTU300 Combined Pressure, Humidity and Temperature Transmitter

DMT345 and DMT346 Dewpoint Transmitters

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

HygroClip2 ADVANCED Humidity Temperature Probes

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Main Catalogue 2009/10. Humidity and temperature measurement

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

HM4. Humidity and Temperature Probe with Heated Sensor. Instruction Manual E-M-HM4-V1_12. HM4 Humidity and Temperature Probe with Heated Sensor

HygroClip 2 (HC2) Humidity Temperature Probes User Guide

RMS Mini Wireless Data Logger

HygroFlex5-EX Humidity & Temperature Transmitter Instruction Manual

Humidity transmitter for critical climate applications

Product data sheet accessories control and regulation Accessories AIRWIN

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

HygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MMT330 Series Moisture and Temperature Transmitters for Oil

InBin-P Pressure switches from 5 Pa Pa

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

More Precision. wiresensor // Draw-wire displacement sensors

Table of contents: 1. HygroClip 2 in general. 2. The different probes. 3. Features in details. 4. Customer benefits. 5. Replacement overview

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

DP DP2500 DP0250

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Differential Pressure Controller DPC 200

Hydrostatic filling level sensor HFB C4 / R / MD

InCos-P Pressure sensor 20 Pa Pa

Draw wire sensors, draw wire sensors for displacement, position

Portable Data LOGGING SYSTEMS. for Professionals

IntesisBox Modbus Server Panasonic

More Precision. wiresensor // Draw-wire displacement sensors

Humidity goes Digital

Precision Hand-held Thermometer

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

TSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

HygroLog NT Humidity Temperature Data Logger Instruction Manual

Temperature Switches

The industrial humidity transmitter

HygroLog NT Humidity Temperature Data Logger. Instruction Manual

RXTH DUAL ROOM SENSOR / SWITCH

A C C S for Road Tunnels. NOVICOM CO/NO/Visibility Monitor Contact us for Information about:

Huba Control. Pressure, vacuum and differential pressure transmitter. 0 3 / 5 / 10 / 30 / 50 mbar EDITION 12/2005

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

CAEL-DP Series Dew Point Transmitter for Industrial Control

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

The industrial humidity transmitter

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

DPC DPC PRECISION DIGITAL MASS FLOW CONTROLLER WITH MULTI-GAS FUNCTIONALITY

RXTP ROOM TEMPERATURE

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Digital electropneumatic Positioner for the integrated mounting on process control valves

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

HygroLog HL20 and HL21 Data Logger. User Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

LAUREL ELECTRONICS, INC.

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Neon pr. ph/ ORP measurement. Applications. Description

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Multi-range pressure and differential pressure transmitter

Process displays For current and voltage

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Clear Benefits of the KRAL Electronic.

Sensor for car parks and tunnels

HygroLog NT Humidity Temperature Data Logger v1.2a Instruction Manual

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

HygroFlex. Humidity Temperature Transmitter. Instruction Manual

ProcessCalibrator Model CPH6000

Differential pressure and air velocity measurement instruments

Transcription:

RELIABLE MEASUREMENTS IN CLEAN ROOMS Measures differential pressure, humidity and temperature Designed specifically for clean rooms Removable humidity and temperature probes for simpler adjustment and cleaning FDA- and GAMP-compatible Digital communication via Ethernet RJ45 and/or MODBUS TCP / RTU Analog input and output signals freely configurable Glass front panel highly resistant to chemicals Optical operating elements for operation with protective gloves

TAKE A CLOSE LOOK: THE MAIN ADVANTAGES AT A GLANCE. The Clean Room Panel, which is fitted with a diaphragm sensor for differential-pressure measurement, is a top-quality device. Validated according to GMP directives, and with its well thought-out design, the CRP5 is optimized for applications in laboratories and clean rooms. Optical buttons, and the magnet-mounted, removable HC2-CRP humidity and temperature probe permit efficient and effective cleaning. Up to 6 measurement values and messages can be displayed via its graphical color display. The colors of the display can be adjusted individually. Alarms, such as faults, exceeded limit values, or warnings are highlighted on the CRP5 display, and can also be forwarded digitally via MODBUS, Ethernet, or relays. Thanks to its analog and digital communication capabilities, the CRP5 is very easy to integrate in any monitoring system. Its comprehensive functional capabilities allow the CRP5 to be configured perfectly for each application. The CRP5 is distinctive in the marketplace through its tough glass front plate and a removable humidity sensor. Proven housing Robust, resistant glass front plate Protection Class IP65 Installation in the wall of the clean room Functional display Measurement values displayed on a color graphics display with trend indicator and alarm signaling Configuration possible via 4 optical buttons Power supply...48 VDC / 18...35 VAC Communication 4 analog outputs: freely allocatable and scalable 2 analog inputs 2 digital inputs Ethernet RJ45; MODBUS TCP / RTU 6 solid-state relays Interchangeable probe Removable humidity and temperature probe HC2-CRP Simple probe calibration outside the room being monitored Alternatively: External HygroClip2 probe for detached humidity and temperature measurement

THE APPLICATIONS The CRP5 clean-room panel is the obvious choice wherever a high degree of cleanliness is vital, in addition to precise measurement of differential pressure, humidity, and temperature. The CRP5 is used particularly in clean-rooms in hospitals, in the pharmaceutical, electronics, and foodstuffs industries, and wherever small variances in pressure are monitored. The very comprehensive functional capabilities of the CRP5 provide solutions for many measurement and control tasks. THE PROBES FOR THE CRP5. The HygroClip2 is available in various versions. From simple standard probes up to highly developed cable probes for high-temperature or other special applications, you will find exactly the probe that you need in our product range. What they all have in common is the high precision, reliability, and long-term stability that individual adjustment assures. And that is precisely what makes each probe in our range a high-end product for normal and industrial applications. Clean-room probe HC2-CRP Any Rotronic probe Precision: ±1.5 %RH Range of application: -5...60 C Probes in stainless steel Magnetic attachment to the CRP5 Precision: up to ±0.5 %RH Range of application: -0...0 C Plastic, stainless-steel and screw-in versions Screw connection via Rotronic E2 plug Would you like more information (special applications, ordering codes, etc.) on the choice of the correct probe? You will find a complete and always up-to-date overview of all our probes at our web site www.rotronic.com.

TECHNICAL INFORMATION Clean-room probe HC2-CRP HC2-CRP Range of application -5...60 C / 0...0 %RH Precision @ 23 C ±3 K ±1.5 %RH / ±0.2 K Power supply 3.3...5 VDC Current consumption 3.5 ma Long-term stability <1 %RH / year Sensor HYGROMER WA-1 Filtertype Teflon, 5 µm Response time 49 s Connection Spring contacts gold plated Housing material Stainless steel 1.4301 / PEEK Weight / Protection type 155 g / IP65 Holder HC2-CRP HOLDER Range of application Connection Housing material Protection type -5...60 C / 0...0 %RH Gold contacts / PicoBlade PEEK IP65 HC2-CRP-HOLDER Accessories AC62 Assembly accessories 2 off Wall bracket AC61 4 off PEEK screws AC62 Service cable AC6 (requires HW4 software) Covers, pressure connections AC60 (without hole) AC60 (with hole) Calibration jig ER-CRP Calibration jig for HygroGen2 ER-CRP-HG2 Cable cm, open end PB-15-PB Cable A for PicoBlade A-80-PB Teflon filter SP-CRP ER-CRP

75 TECHNICAL INFORMATION. 75 75 Technical drawings, 160 CRP5 180 4 48 75 75 160 180 140 4 48 160 160 180 180 4 4 48 48 160 180 With front-mounted probe HC2-CRP With HygroClip2 connection on back HC2-CRP HC2-CRP Holder CRP Wall Bracket 3 140 Ø 56 Guide pin 1. VCC 2. GND 3. Rx 4. Tx 140 140 Ø 44 2,5,8 25,3 140 290 5 M4 Ø 4,5 Guide pin (coding-side) Coding 1. VCC 2. GND 3. Rx (UART) 4. Tx (UART) 5. nc 6. nc Ø 4,5 M4

TECHNICAL DATA. CLEAN ROOM PANEL - CRP5 General Parameters Differential pressure, temperature, relative humidity, digital and analog inputs Housing material Front: Glass Back: Stainless Steel IP protection Front: IP65 (also with sensors removed) Back: IP Mounting position Wall Mounting Display Color TFT display Menu Navigation 4 optical buttons Electrical connections Screw terminals on back Power supply...48 VDC / 18...35 VAC Current Consumption <500 ma Range of application / Storage conditions -5...60 C (23..140 F) / 0...0 %RH Firmware update via HW4 software Service interface UART CE / EMC compatibility EMC Directive 04/8/EC Fire protection class Corresponds to UL94-HB FDA- / GMP compatible 21 CFR Part 11 and GAMP5 Dimensions 180 x x 72 mm Weight 1,700 g (with humidity sensor) 1,550 g (without humidity sensor) Differential Pressure Measurement Measurement principle Diaphragm sensor Measurement ranges ±50 Pa / ±0 Pa / ±250 Pa / ±500 Pa Medium Air and non-aggressive gases Accuracy at 23 C ±3 K ±1.0 % full-scale Zero drift Compensated (manual or automatic zero adjustment) Measurement interval 1 s Pressure resistance 0.7 bar (70,000 Pa) Pressure connections Front: Hose connectors Ø 6 mm x mm Back: Hose connectors Ø 4 mm x mm Temperature measurement / Relative-humidity measurement Probes HC2-CRP; alternatively: any HygroClip2 probe Measurement range -0...0 C (probe-dependent) / 0...0 %RH Outputs Analog outputs 4, freely configurable Analog output type 0 / 4... ma or 0...1 / 5 / V Switch output 6 solid-state relays Switching capacity <50 VDC at <2 A when observing polarity <35 VAC at <1 A, irrespective of polarity Accuracy, analog output ±5 mv (voltage output) ± µa (current output) Permissible load > kω (voltage output) <500 Ω (current output) Digital communication Ethernet (Modbus TCP, HW4) / RS-485 (Modbus RTU, HW4) Technical changes, errors and omissions reserved at all times ROTRONIC AG, Grindelstrasse 6, CH - 8303 Bassersdorf, Tel. +41 44 838 11 44, www.rotronic.ch ROTRONIC Instruments (UK) Ltd, Crompton Fields, Crompton Way, Crawley, West Sussex, RH 9EE, UK, Phone +44 (0)1293 5700, www.rotronic.co.uk ROTRONIC Instrument Corp, 135 Engineers Road, Hauppauge, NY 11788, USA, Phone, +1 631 427-3898, www.rotronic-usa.com ROTRONIC Canada Inc., 236 Pritchard Rd, Unit 4, Hamilton, ON, Canada, L8W 3P7, Phone + 1 416-848-7524, www.rotronic.ca ROTRONIC Instruments Pte. Ltd., 03 Bukit Merah Central, #06-31 Inno Centre, Singapore 159836, Phone +65 6376 27, www.rotronic.sg 59048E/15-