Table of contents: 1. HygroClip 2 in general. 2. The different probes. 3. Features in details. 4. Customer benefits. 5. Replacement overview
|
|
- Jennifer Tate
- 5 years ago
- Views:
Transcription
1 HygroClip 2
2 Table of contents: 1. HygroClip 2 in general 2. The different probes 3. Features in details 4. Customer benefits 5. Replacement overview
3 1. HygroClip 2 in general The HC2-series are digital humidity-temperature probes based on the AirChip 3000 technology. These probes feature a UART serial interface and two 0 1 V linear analog output signals.
4 1. HygroClip 2 in general The HC2 probes are designed for use with the HygroClip 2 generation of ROTRONIC humidity-temperature instruments: hand-held and bench top indicators, data loggers, transmitters, hygrostats, etc
5 1. HygroClip 2 in general The HC2 probes maintain all of the benefits of the original HygroClip technology such as the possibility of hot-swapping probes. Also significant improvements in the area of measurement accuracy and functionality are integrated.
6 1. HygroClip 2 in general The HC2 probes can also be used as a stand-alone device featuring: Analog output signals and Digital interface (UART)
7 1. HygroClip 2 in general The HC2 probes offer the following user functions: Calculation of the dew or frost point Humidity temperature calibration and adjustment Simulator mode Automatic humidity sensor test and drift compensation Sensor failure mode Data recording
8 1. HygroClip 2 in general Recommended supply voltage Nominal current consumption Maximum start-up current unlimited Minimum start-up current required Maximum current spike during operation Polarity protection Power supply and connections 3.3 VDC < 4.5 ma at VDD = 3.3 VDC 7.5 ma at VDD = 5 VDC < 50mA during 2µs Typical: 8 ma during 2ms and 5 ma during 2s 1 ma during maximum 2µs Mechanical only (keyed connector)
9 1. HygroClip 2 in general Humidity measurement Sensor Measuring range Measurement accuracy at 23 C Repeatability Long term stability Sensor time constant ROTRONIC Hygromer IN %RH ±0.8 %RH (w. standard adjustment profile) 0.3 %RH < 1 %RH / year Typical 10 sec, 63% of a 35 to 80 %RH step change (1m/sec air flow at sensor)
10 1. HygroClip 2 in general Temperature measurement Sensor Measuring range Measurement accuracy at 23 C Repeatability Long term stability Sensor time constant Pt100 RTD, IEC 751 1/3 class B C (see also environmental limits) ±0.1 C 0.05 C < 0.1 C / year Typical 4 sec, 63% of a step change (1m/sec air flow at sensor)
11 1. HygroClip 2 in general Calculated parameters Psychrometric calculations Start-up time and data refresh rate Start-up time Data refresh rate Dew or frost point (user configurable) 1.5s (typical) 1.0s (typical) when not calculating any parameter
12 1. HygroClip 2 in general Digital interface Interface type Organization Default configuration Baud rate configuration: Logical levels Maximum cable length UART (Universal Asynchronous Receiver Transmitter) Dialog, duplex Baud rate : Parity : none Data bits : 8 Stop bits : 1 No Logical 0: < = 0.3V * VDD Logical 1: > = 0.8V * VDD 5 m (16.4 ft) w/o signal booster
13 1. HygroClip 2 in general
14 2. The different probes Climate measurement HC2-S HC2-S3 Standard HygroClip2 (black) Standard HygroClip2 (white) Main utilization: indicators, data loggers and transmitters, with or without an extension cable
15 Measurement in tight spaces Main utilization: indicators, data loggers and transmitters
16 2. The different probes Spot check measurements in air ducts, chambers, ovens HC2-HK25 HC2-HK40 High Temp. HygroClip2 hand probe Temperature limits at sensor C High Temp. HygroClip2 hand probe Temperature limits at sensor C Main utilization: indicators and data loggers
17 2. The different probes Measurement of dust-free granular products in bulk HC2-P05 Mini insertion HygroClip2 hand probe Temperature limits C Main utilization: indicators and data loggers
18 2. The different probes Measurement of seeds, granulates and powders in bulk HC2-HP28 HC2-HP50 Insertion HygroClip2 hand probe Barrel: diameter: 10 mm, length: 280 mm Insertion HygroClip2 hand probe Barrel: diameter: 10 mm, length: 500 mm Main utilization: indicators and data loggers
19 2. The different probes Measurement of paper cardboard stacks and rolls HC2-HS28 HC2-HS42 Sword HygroClip2 probe Blade: 4 mm x 22 mm, length: 280 mm Sword HygroClip2 probe Blade: 4 mm x 22 mm, length: 420 mm Main utilization: indicators and data loggers
20 2. The different probes Process measurement (fixed installation) HC2-IC102 HC2-IC105 HC2-IC110 Industrial HygroClip2 PPS probe Temperature limits at sensor C Barrel: diameter: 15 mm, length: 100 mm Probe cable length.: 2 m Probe cable length.: 5 m Probe cable length.: 10 m Main utilization: transmitters and data loggers
21 2. The different probes Process measurement (fixed installation) HC2-IC302 HC2-IC305 HC2-IC310 Industrial HygroClip2 PPS probe Temperature limits at sensor C Barrel: diameter: 15 mm, length: 250 mm Probe cable length.: 2 m Probe cable length.: 5 m Probe cable length.: 10 m Main utilization: transmitters and data loggers
22 2. The different probes Process measurement (fixed installation) HC2-IC402 HC2-IC405 HC2-IC410 Industrial HygroClip2 PPS probe Temperature limits at sensor C Barrel: diameter: 15 mm, length: 400 mm Probe cable length.: 2 m Probe cable length.: 5 m Probe cable length.: 10 m Main utilization: transmitters and data loggers
23 2. The different probes Process measurement (fixed installation) HC2-IC502 HC2-IC505 HC2-IC510 Industrial HygroClip2 PPS probe Temperature limits at sensor C Barrel: diameter: 15 mm, length: 550 mm Probe cable length.: 2 m Probe cable length.: 5 m Probe cable length.: 10 m Main utilization: transmitters and data loggers
24 2. The different probes Process measurement (fixed installation) HC2-IC702 HC2-IC705 HC2-IC710 Industrial HygroClip2 PPS probe Temperature limits at sensor C Barrel: diameter: 15 mm, length: 700 mm Probe cable length.: 2 m Probe cable length.: 5 m Probe cable length.: 10 m Main utilization: transmitters and data loggers
25 2. The different probes Process measurement (fixed installation) HC2-IC302-A Industrial HygroClip2 PPS probe C diameter: 25/15 mm, length: 250 mm Probe cable length.: 2 m HC2-IC305-A Probe cable length.: 5 m HC2-IC310-A Probe cable length.: 10 m Main utilization: transmitters and data loggers
26 2. The different probes Process measurement (fixed installation) HC2-IC302-A Industrial HygroClip2 PPS probe C diameter: 25/15 mm, length: 250 mm Probe cable length.: 2 m HC2-ICxXX-A A= 25/15 diameter /robust Cable length (2,5,10m) Probe length (1,3,4,5,7) Industrial PPS cable versions HygroClip 2 Technology Main utilization: transmitters and data loggers
27 2. The different probes Process measurement (fixed installation) HC2-IM102 Industrial HygroClip2 metal probe C diameter: 15 mm, length: 100 mm Probe cable length.: 2 m HC2-IM105 Probe cable length.: 5 m HC2-IM110 Probe cable length.: 10 m Main utilization: transmitters and data loggers
28 2. The different probes Process measurement (fixed installation) HC2-IM302 Industrial HygroClip2 metal probe C diameter: 15 mm, length: 250 mm Probe cable length.: 2 m HC2-IMxXX Cable length (2,5,10m) Probe length (1,3,4,5) Industrial metal cable vers. HygroClip 2 Technology Main utilization: transmitters and data loggers
29 2. The different probes Measurement in compressed air conduits and vessels HC2-IE102 Industrial HygroClip2 metal / screw in probe C / max. 100bar (1450 PSI) G ½ thread Probe cable length.: 2 m HC2-IE105 Probe cable length.: 5 m HC2-IE110 Probe cable length.: 10 m Main utilization: transmitters and data loggers
30 2. The different probes Measurement in compressed air conduits and vessels HC2-IE302 Industrial HygroClip2 metal / screw in probe C / max. 100bar (1450 PSI) NPT½ thread Probe cable length.: 2 m HC2-IE305 Probe cable length.: 5 m HC2-IE310 Probe cable length.: 10 m Main utilization: transmitters and data loggers
31 3. Features in detail Mechanical improvements: Very robust connector One connector for all probes! Foolproof connection Temperature barrier from mass to sensor Sensor connector Bulkhead improvements New filter technology Tight ultrasonic welded housing
32 3. Features in detail AirChip 3000: Highest accuracy of a RH-probe on the market Sole RH-probe with full ERES conformance Dew point / Frost point probe Simulator mode Automatic humidity sensor test and drift compensation Sensor failure mode Alarming Data recording
33 Checks the atmosphere humidity, temperature, dew-point
34 Not narrow minded free scaling, configurable
35 Foresight Auto diagnostic function
36 Remains young Dynamic aging compensation Typical characteristic of an aged, exposed to contaminants sensor and therefore drifted Active compensation
37 is independent Alarming before break down
38 dead straight AirChip 3000 linearization and compensation
39 no secrets open, accessible data of mathematic results
40 the auditor may simulate digital and analog outputs
41 is a historian Data logging, recording
42 4. Customer benefits Highest accuracy of a RH-probe on the market Sole RH-probe with full ERES conformance Dew point / Frost point probe Simulator mode Automatic humidity sensor test and drift compensation Sensor failure mode Alarming Data recording
43 4. Customer benefits Saving money on maintenance High availability all over the world modular designed basic types on stock easy modification from ROTRONIC distributors Easy integration in custom specific applications Free firmware update on lifetime
44 5. Replacement overview Product name HC2-S HC2-S3 (white housing) HC2-C04 HC2-C05 HC2-HK25 HC2-HK40 HC2-P05 HC2-HP28 HC2-HP50 HC2-HS28 HC2-HS42 Replaces HygroClip S HygroClip S3 HygroClip SC04 HygroClip SC05 HygroClip HK25 HygroClip HK40 HygroClip SP05 HygroClip HP28 HygroClip HP50 HygroClip HS28 HygroClip HS42
45 5. Replacement overview Product name HC2-IC102 HC2-IC105 HC2-IC110 HC2-IC302 HC2-IC302-A HC2-IC305 HC2-IC305-A HC2-IC310 HC2-IC310-A HC2-IC402-A HC2-IC502-A HC2-IC702-A Replaces HygroClip IC-1 HygroClip IC-1-05 HygroClip IC-1-10 HygroClip IC-3 HygroClip IC-3-15/25 HygroClip IC-3-05 HygroClip IC /25 HygroClip IC-3-10 HygroClip IC /25 HygroClip IC HygroClip IC HygroClip IC
46 5. Replacement overview Product name HC2-IM102 HC2-IM105 HC2-IM110 HC2-IM302 HC2-IM305 HC2-IM310 HC2-IM402 HC2-IM502 Replaces HygroClip IM-1 HygroClip IM-1-05 HygroClip IM-1-10 HygroClip IM-3 HygroClip IM-3-05 HygroClip IM-3-10 HygroClip IM4 HygroClip IM5
47 5. Replacement overview Product name HC2-IE102 HC2-IE105 HC2-IE110 HC2-IE302 HC2-IE305 HC2-IE310 Replaces HygroClip IE-1-M HygroClip IE-1-M-05 HygroClip IE-1-M-10 HygroClip IE3-M HygroClip IE3-M-05 HygroClip IE3-M-10 Only metal versions available
48 HygroClip 2
HygroClip 2 (HC2) Humidity Temperature Probes User Guide
Page 1 of 50 Probes User Guide Page 2 of 50 Table of contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Models... 4 3 General description... 25 3.1 Power supply... 25 3.2 Measured
More informationHygroClip2 ADVANCED Humidity Temperature Probes
Humidity Temperature Probes 2016 ROTRONIC AG Bassersdorf Switzerland Table of contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Models... 4 3 General description... 18 3.1 Power supply...
More informationHygroFlex HF7 Humidity Temperature Transmitters. User Guide
Page 1 of 22 HygroFlex HF7 Humidity Temperature Transmitters User Guide Page 2 of 22 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 3 General description... 5 3.1 Power
More informationHygroClip DIGITAL Humidity and temperature probe
HygroClip DIGITAL Humidity and temperature probe 2016 ROTRONIC AG Bassersdorf Switzerland Contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Variants... 4 3 General information...
More informationIntelligence. humidity and temperature probes. Introducing AirChip Digital Technology.
humidity and temperature probes Unique Sensing Intelligence. Introducing AirChip Digital Technology. Innovation in Humidity and Temperature Measurement Relative humidity, temperature measurement and dew
More informationHumidity Temperature Transmitter User Guide
Page 1 of 29 XB Humidity Temperature Transmitter 2015; E-M-XB-V1_26 Page 2 of 29 Table of contents 1 Overview... 3 2 Dimensional drawings... 4 3 General description... 5 3.1 Power supply... 5 3.2 Measured
More informationHygroFlex HF7 Humidity Temperature Transmitters. User Guide
Page 1 of 27 HygroFlex HF7 Humidity Temperature Transmitters User Guide Page 2 of 27 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 3 General description... 5 3.1 Power
More informationHygroFlex HF3 Transmitters. User Guide
Page 1 of 27 HygroFlex HF3 Transmitters User Guide Page 2 of 27 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 2.1 Display option... 5 3 General description... 6 3.1
More informationHumidity goes Digital
Industrial Humidity Temperature Transmitter Dew-point and other calculated values Wide range of digital interchangeable probes No need for field calibration PC compatible and RS485 networkable SWISS MADE
More informationHygroLog HL20 and HL21 Data Logger. User Guide
Page 1 of 17 HygroLog HL20 and HL21 Data Logger Page 2 of 17 Table of contents: 1. Overview... 3 1.1 General... 3 2. General description... 4 2.1 Models... 4 2.2 Required accessories... 4 2.3 Batteries...
More informationHygroFlex HF3 Transmitters and Thermohygrostats: User Guide
Page 1 of 26 HygroFlex HF3 Transmitters and thermo-hygrostats Page 2 of 26 Table of contents 1 Overview... 3 2 Mechanical configurations and dimensions... 4 2.1 Display option... 5 3 General description...
More informationHumidity goes Digital
Humidity goes Digital Networkable Industrial Transmitter Humidity, Temperature and Dew Point or other Computed Parameter Optional metal enclosure Unique HygroClip technology for superior performance Durable,
More informationHygroLog HL20 and HL21 Data Logger. User Guide
Page 1 of 23 HygroLog HL20 and HL21 Data Logger Page 2 of 23 Table of contents: 1. Overview... 4 1.1 General... 4 2. General description... 5 2.1 Models... 5 2.2 Required accessories... 5 2.3 Batteries...
More informationHygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual
HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual page 2 of 15 Contents: Overview... 2 Models... 3 Power... 4 Probes... 4 Connector identification... 5 Pin-out diagrams... 6
More informationPCD DIGITAL Differential pressure probe
Differential pressure probe 2016 ROTRONIC AG Bassersdorf Switzerland Contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Variants... 4 3 General information... 6 3.1 Power supply...
More informationHW4 Software version 2. Probe Adjustment function Legacy devices
Page 1 of 12 HW4 Software version 2 Probe Adjustment function Page 2 of 12 Table of contents 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 3 PROBE ADJUSTMENT... 4 3.1 Overview... 5 3.2 Menu Bar...
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationHW4 Software version 3. HP23 Humidity Temperature Indicator
Page 1 of 27 HW4 Software version 3 2010-2011; E-M-HW4v3-F2-012_11 Page 2 of 27 Table of contents 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 2.1 Functions and settings overview... 4 2.2 Detecting
More informationHW4 Software version 3. Device Manager HygroClip DI
Page 1 of 10 HW4 Software version 3 2010 E-M-HW4v3-F1-003_10 Table of contents Page 2 of 10 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 3 DEVICE MANAGER... 4 3.1 Device Manager Menu Bar... 5
More informationHygroFlex TF5 Temperature Transmitter. User Guide
Page 1 of 23 HygroFlex TF5 Temperature Transmitter Page 2 of 23 Table of contents 1 Overview... 3 2 Dimensional drawings... 4 2.1 Display and keypad option... 4 3 General description... 5 3.1 Power supply...
More informationHW4 Software version 3. Device Manager TF5 Temperature Transmitter
Page 1 of 15 HW4 Software version 3 Device Manager 2010; E-M-HW4v3-F2-017_10 Table of contents Page 2 of 15 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 3 DEVICE MANAGER... 4 3.1 Device Manager
More informationHygroFlex5-EX Humidity & Temperature Transmitter Instruction Manual
Page 1 of 24 HygroFlex5-EX Humidity & Temperature Page 2 of 24 Table of contents 1 General information... 3 1.1 About this manual... 3 1.2 Document versions... 3 1.3 Supporting documents... 3 2 Overview...
More informationMain Catalogue 2009/10. Humidity and temperature measurement
Main Catalogue 2009/10 Humidity and temperature measurement How to contact ROTRONIC? ROTRONIC is a family owned group of companies with headquarters in Switzerland, and subsidiaries and distributors world-wide.
More informationDMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions
www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew
More informationMain catalogue. Measurement solutions for multiple parameters HUMIDITY TEMPERATURE CO2 DIFFERENTIAL PRESSURE PRESSURE FLOW WATER ACTIVITY DEW POINT
Main catalogue Measurement solutions for multiple parameters HUMIDITY TEMPERATURE CO2 DIFFERENTIAL PRESSURE PRESSURE FLOW WATER ACTIVITY DEW POINT ma/v ma V How to contact Rotronic ROTRONIC Instruments
More informationHygroLog NT Humidity Temperature Data Logger. Instruction Manual
HygroLog NT Humidity Temperature Data Logger Instruction Manual in-lognt-r11 02/15/2005 - 2 - Contents: DESCRIPTION... 3 Overview... 3 HygroLog NT - hardware description... 4 Models... 4 Memory... 4 Probes...
More informationHygroPalm. Portable Humidity Temperature Indicator. Instruction Manual
HygroPalm Portable Humidity Temperature Indicator Instruction Manual - 2 Contents Overview... 3 General Description... 5 Power Requirements... 5 Optional Docking Station (PalmDock)... 5 Probes and Probe
More informationHygroFlex. Humidity Temperature Transmitter. Instruction Manual
HygroFlex Humidity Temperature Transmitter Instruction Manual v3 - 2 - Contents Overview...3 General Description...4 Power Requirements...4 Probes and Probe Inputs...5 Analog Outputs (HygroFlex 1 and HygroFlex
More informationHygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL
HygroClip M22 Series 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL 20060329 CONTENTS Overview... 3 Operation... 5 Power supply... 5 HygroClip S digital probe... 5 Temperature
More informationHygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual
HygroPalm 0 Portable Humidity Temperature Indicator Instruction Manual v 3 20040211 - 2 Contents Overview... 3 General Description... 3 Power Source... 3 Optional Docking Station (PD1-ACA)... 3 Unit System...
More informationKCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement
Our CO2 gas sensors get a small deviation unlike NDIR Single type. So they keep long term stability. KCD-HP100x Excellent stability and accuracy - through testing and calibration with sophisticated process
More informationDMT345 and DMT346 Dewpoint Transmitters
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662
More informationAM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL
AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL CONTENTS 1. Battery Operation... 3 2. Operation with a Rechargeable Battery... 3 3. Humidity and Temperature Probe (Probe Input 1)... 3
More informationHMT330 Series Humidity and Temperature Transmitters for Industrial Applications
HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial
More informationCLEAN ROOM PANEL - CRP5
RELIABLE MEASUREMENTS IN CLEAN ROOMS Measures differential pressure, humidity and temperature Designed specifically for clean rooms Removable humidity and temperature probes for simpler adjustment and
More informationTransmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD
Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x D 1 INTRODUCTION The RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD transmitters
More informationHygroLog NT Humidity Temperature Data Logger Instruction Manual
HygroLog NT Humidity Temperature Data Logger Instruction Manual page 2 of 41 Contents: OVERVIEW... 4 HygroLog NT DATALOGGER... 5 Models... 5 Power... 5 Battery lifetime... 6 Battery replacement... 6 Probes...
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative humidity (RH) and temperature (T), the transmitter also calculates parameters
More informationEE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.
Series High-Precision Air / Gas Velocity Transmitter for Industrial Applications The series air velocity transmitters were developed to obtain accurate measuring results over a wide range of velocities
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationHygroLog NT Humidity Temperature Data Logger v1.2a Instruction Manual
HygroLog NT Humidity Temperature Data Logger v1.2a Instruction Manual page 2 of 43 Contents: OVERVIEW... 4 OVERVIEW... 4 HygroLog NT DATALOGGER... 5 Models... 5 Power... 5 Battery lifetime... 6 Battery
More informationH290 HUMIDITY TRANSMITTER INSTRUCTION MANUAL
H290 HUMIDITY TRANSMITTER INSTRUCTION MANUAL DESCRIPTION 4 OPERATION 4 Power Supply 4 Output Signal 4 Temperature Operating Range and Limits 4 Humidity Limits 5 Temperature Compensation 5 Sensor Protection
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
High-End Humidity and Temperature Transmitter for Demanding Process Control is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative
More informationTEMPERATURE - HUMIDITY ELEKTRONIK EE08
TEMPERATURE - HUMIDITY ELEKTRONIK EE08 SENSOR MEASURE SIGNAL OUTPUT ELECTRICAL SUPPLY MODEL IN EOL MANAGER Temperature 0...1 V 12...24 V EE8 / ROTRONIC Humidity 0...1 V 12 24 V EE8 / ROTRONIC APPLICATION
More informationRMS Mini Wireless Data Logger
RMS Mini Wireless Data Logger 2016 ROTRONIC AG Bassersdorf Switzerland Table of Contents 1 Overview... 3 1.1 RMS System Overview... 3 1.2 Device Overview... 4 1.3 RMS Mini Data Logger... 5 1.4 Power Supply...
More informationFTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist
FTM84/85 Feature Application IP65 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Llinear adjustment air velocity by computer, analogue output
More informationEE35. Industrial Transmitter for Dew Point Measurement. Autocalibration. Installation. Alarm Output. Integrated power supply. Typical Applications
EE35 Industrial Transmitter for Dew Point Measurement Exact dew point monitoring is increasingly playing a more important role in many industrial applications, such as drying processes, air pressure pipelines,
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationMeasurement solutions for multiple parameters
Measurement solutions for multiple parameters HUMIDITY TEMPERATURE DEW POINT WATER ACTIVITY DIFFERENTIAL PRESSURE PRESSURE FLOW CO2 ROTRONIC WORLDWIDE ROTRONIC is represented in more than 40 countries
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationEE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationRHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter
RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x A 1 INTRODUCTION The RHT-WM-485-LCD and RHT-DM-485-LCD transmitters include high
More informationEE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical
EE80 Series HVAC Room Transmitter and Switches for, Relative Humidity and Temperature EE80 series set new standards in measurements for HVAC. The transmitters resp. switches combine, relative humidity
More informationWATER ACTIVITY MEASUREMENT WATER ACTIVITY
MEASUREMENT WATER ACTIVITY FAST AND PRECISE WATER ACTIVITY MEASUREMENTS. INTRODUCING AIRCHIP DIGITAL TECHNOLOGY. Determine product quality with ROTRONIC Aw products ROTRONIC Aw devices for laboratory and
More informationPTU300 Combined Pressure, Humidity and Temperature Transmitter
PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface
More informationHumidity Temperature Indicator. Instruction Manual
BT-RS1 Humidity Temperature Indicator Instruction Manual -2- GENERAL 3 DEFAULT SETTINGS 3 DESCRIPTION 3 Front Panel 4 Back Panel 4 Electrical Connections 4 OPERATION 5 Stand Alone Operation 5 PC Operation
More informationaccurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationRMS Mini Wireless Data Logger
2018 ROTRONIC AG Bassersdorf Switzerland Table of Contents 1 Overview... 3 1.1 RMS System Overview... 3 1.2 Device Overview... 4 1.3 RMS Mini Data Logger... 5 1.4 Power Supply... 5 1.5 Measured Parameters...
More informationHLX75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C
Series High-Precision Air / Gas Velocity Transmitter for Industrial Applications The series air velocity transmitters were developed to obtain accurate measuring results over a wide range of velocities
More informationElectronic pressure switch with display Model PSD-4
Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine
More informationSchneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.
1 Series Specifications Input age. 24 VAC ±20%, 20 to 36 VDC Class 2 Analog....4-20 /0-5 VDC/0-10 VDC (selectable) Sensor Current Draw... 20-36 VDC 40 avg., 105 max. 24 VAC 50 avg., 150 max. Operating
More informationHTZ. Description. Features. Smart HART Humidity and Temperature Transmitter
March 2018 Description The HTZ Smart HART Transmitter simultaneously measures humidity and temperature in industrial, commercial, manufacturing, and HVAC applications. Based on the humidity and temperature
More information2016 ROTRONIC AG Bassersdorf Switzerland. RMS Data Logger
2016 ROTRONIC AG Bassersdorf Switzerland RMS Data Logger Table of Contents 1 Overview... 3 1.1 RMS System Overview... 3 1.2 Device Overview... 4 1.3 RMS Data Logger... 5 1.4 Power Supply... 5 1.5 Measured
More informationData logger systems from ROTRONIC
Data logger systems from ROTRONIC RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network Logger with power supply RS-485
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationPRELIMINARY! DIGITAL HUMIDITY SENSOR
Characteristic features Measuring range 0.. 100 % rh, -40.. 125 C Calibrated and temperature-compensated Accuracy ±1.8 % RH and ±0.2 C (-H) Chemical resistant, dew formation resistant Low hysteresis, compensated
More informationMP 101A HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL
MP 101A HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL -2- CONTENTS DESCRIPTION...3 OPERATION...3 INSTALLATION...4 MAINTENANCE...7 CALIBRATION BASICS...7 CALIBRATION PROCEDURE...8 SPECIFICATIONS...11 PLEASE,
More informationHumidity transmitter for critical climate applications
Humidity transmitter for critical climate applications testo 6651 Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs
More informationA1H Portable Humidity Temperature Indicator Instruction Manual
A1H Portable Humidity Temperature Indicator Instruction Manual -2- CONTENTS Description...3 Operation...3 Measurement...4 Maintenance...4 Probe Installation and Removal...5 Output Connector...6 Accessories
More informationDCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor
DCT 5 Industrial Pressure Transmitter with RS85 Modbus RTU Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar output
More informationHMT330 Series Humidity and Temperature Transmitters for Industrial Applications
HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. P.O. Box 26, FI-00421 Helsinki,
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationProduct Guide. Repeatable RH and temperature measurement for precise humidity control and validation
Repeatable RH and temperature measurement for precise humidity control and validation Relative Humidity Probes, Transmitters & Validators The Best in Relative Humidity Measurement to Optimize your Process
More informationTemperature / Humidity Controller for Stability Chamber
Temperature / Humidity Controller for Stability Chamber Model Wise Description: Sr. No Model Product Description 14.2.4 HTC-3003 Microcontroller based Temperature & %RH PID-On/Off controller (2 AI + 2
More informationP30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application
P30-2 Pressure Transmitter Datasheet At a Glance *High Quality* 3 Years Warranty Premium Pressure Transmitter for gauge and pressure measurement with 3 years warranty High repeatability and long-term stability
More informationCRP5 Clean Room Panel. Instruction Manual
Page 1 of 39 CRP5 Clean Room Panel 2018; Page 2 of 39 Contents 1 Short Description of the Product... 3 Delivery Package... 4 Main Features of the CRP5... 5 Technical Drawings... 6 2 General Description...
More informationHLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.
Series The precise and reliable measurement of humidity in industrial processes is gaining more and more importance. The multifunctional transmitters series offer the ideal solution. The result of many
More informationModel T3000 Resistance Temperature Transmitters
odel T3000 Description The T3000-series is a robust temperature transmitter using a RTD (resistance temperature detector) as the sensing element. This RTD is a Pt100 which is a temperature sensitive platinum
More informationCRP5 Clean Room Panel. Instruction Manual
Page 1 of 36 CRP5 Clean Room Panel Page 2 of 36 Contents 1 Short Description of the Product... 3 1.1 Delivery Package... 4 1.2 Main Features of the CRP5... 5 1.3 Technical Drawings... 6 2 General Description...
More informationDTB-1. Digital Thermometer Battery Powered
Digital Thermometer Battery Powered Battery powered 100mm stainless steel case (IP65) Direct mount, panel mount, or surface mount Clear 6 digit alphanumeric LCD display Configured C or F High accuracy
More informationHC322 HUMIDITY / DEW POINT AND TEMPERATURE TRANSMITTER INSTRUCTION MANUAL
HC322 HUMIDITY / DEW POINT AND TEMPERATURE TRANSMITTER INSTRUCTION MANUAL -2- INTRODUCTION...4 Temperature Limits at the Electronics...5 Operating Limits at the Sensors...5 Sensor Protection...6 INSTALLATION...6
More informationEE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211
Humidity and Temperature Transmitter for Continuous High Humidity The is dedicated for accurate and long term stable measurement under continuous high humidity (>85 % RH) and condensing conditions in demanding
More informationDMT340 Series Dew Point and Temperature Transmitters
DMT340 Series Dew Point and Temperature Transmitters For Very Dry Conditions Features Measures dew point from -70... +80 C (-94... +176 F) with an accuracy of ±2 C (±3.6 F) Condensation-resistant Unique
More informationAvoid experiments in monitoring important parameters. Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries
Avoid experiments in monitoring important parameters Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries ABOUT ROTRONIC Swiss precision at the highest level Founded
More informationRMS WIRELESS MINI LOGGER
RMS WIRELESS MINI LOGGER COMPACT, VERSATILE & FLEXIBLE Various models to measure and log humidity, temperature, lux and electrical values Stores up to 10 000 values Fail safe, due to internal battery and
More informationHygroFlex M. Meteorological Humidity Temperature Transmitter. Instruction Manual
HygroFlex M Meteorological Humidity Temperature Transmitter Instruction Manual v3 20020716 - 2 - Contents Overview...3 General Description...4 Power Requirements...4 Probes and Probe Inputs...4 Analog
More informationMTII4200 Level Transmitter Installation, Operation & Maintenance Instructions
Specialists in Liquid Level Indication MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions Section: M500 Bulletin: M500.31 Date: 05-17-16 Supersedes: 09-30-11 1. INTRODUCTION
More informationGMM220 CO 2. Transmitter Modules. Introduction. Mounting
Introduction GMM220 CO 2 Transmitter Modules Vaisala GMM220 transmitter modules are versatile instruments for measuring CO 2 in industrial applications. The CARBOCAP sensor is silicon based and its operation
More informationSubmersible Liquid Level Transmitter Series: PT-500
Submersible Liquid Level Transmitter Series: PT-500 The PT-500 is a rugged submersible pressure transmitter designed for tank liquid level measurement, water and wastewater applications, and well depth
More informationDP DP2500 DP0250
DP7000 - DP2500 DP0250 PB_DP7000_DP2500 - DP0250_07 2016 Field adjustable, multi-range differential pressure transmitters Product Bulletin The Delta Pressure transmitter series of Johnson Controls, with
More informationFILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane
Filter Caps for Humidity and Dewpoint Transmitters with probe 12 mm (0.47 ) The right choice of appropriate filter cap is essential for best long term performance in the application. For assistance please
More informationSensor for car parks and tunnels
Page 1 Sep. 2017 system with exchangeable sensor element including digital value processing, temperature compensation and selfmonitoring algorithm for the continuous sensing and control of the ambient
More informationINSTRUCTION MANUAL HBPH DIFFERENTIAL 2-WIRE (4-20 ma) ph Sensor
INSTRUCTION MANUAL HBPH DIFFERENTIAL 2-WIRE (4-20 ma) ph Sensor TABLE OF CONTENTS 1. GENERAL INFORMATION 2 2. SPECIFICATIONS 2 3. INSTALLATION 3 3.1. General Instructions 3 3.2. HBPH 4-20 ma Sensor 3 4.
More informationHM4. Humidity and Temperature Probe with Heated Sensor. Instruction Manual E-M-HM4-V1_12. HM4 Humidity and Temperature Probe with Heated Sensor
Page 1 of 41 HM4 Humidity and Temperature Probe with Page 2 of 41 Table of Contents 1 Overview... 4 1.1 Scope... 5 1.2 Background Information on the Principle of Measurement... 5 2 Mechanical Variants
More informationEchotouch, EchoSpan & EchoSwitch Ultrasonic Liquid
Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that
More informationNI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server
DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationMODEL ELECTRONIC COMPASS
MODEL 32500 ELECTRONIC COMPASS REV K080703 MANUAL PN 32500-90 R. M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 SPECIFICATIONS* Compass:
More informationDP2500 DP0250. Differential Pressure Transmitter. Product Bulletin
DP2500 DP0250 Differential Pressure Transmitter Product Bulletin The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air and
More information