Operating guide. Private Circuits

Similar documents
SIN 158 Issue 3.6 May 2018

You can do more with. Business Highway

Suppliers' Information Note. BT International MegaStream (2Mbit/s) Service Description

Get the message wherever you are. Call Minder for Cloud Voice

Suppliers Information Note. Synchronisation Recommended Settings for Customer Premises Equipment

Suppliers' Information Note. BT MegaStream 622, BT MegaStream Aggregate (STM4) Service Description

Suppliers' Information Note. BT International Megastream 155. Service Description

V Telephone User Guide

Welcome. BT Mini Connector Kit user guide

Get the message wherever you are Call Minder User Guide

BT Business Infinity Fibre to the Premises.

FEATURELINE CORPORATE.

Featureline. Site User Guide To make an external call press 9 followed by the telephone number

Suppliers Information Note. BT MediaNet Plus Network Service. Interface Characteristics & Withdrawal Notification

BT One Phone. Yealink SIP-T40 phone user guide

1 Plug in 2 Add to your existing network 3 Connect your devices

FEATURELINE. SITE USER GUIDE. This user guide provides you with all the information you need to get the most from your Featureline Phone.

User Guide Automatic Transfer Switch (ATS)

1 Connect to your hub/router

Your guide to ISDN 30

BT Wholesale Machine to Machine

Yealink W60 IP DECT phone. A guide to using your phone with Cloud Voice

Airway. User Guide. ISDN Card

Calculating the real cost of a business phone system. How a cloud phone system ultimately gives you more for your money

1 Plug in extender near your router. Mini Wi-Fi Home Hotspot 500 Kit User Guide

Boost your business with a more flexible phone system. Cut costs and do more with your calls with BT Cloud Voice

BT Decor User Guide

BT Decor 2600 Premium Nuisance Call Blocker

Go beyond broadband with BTnet.

BT Cloud Voice Smart Yealink W52P IP DECT phone. User guide

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

Yealink T46 IP phone. A guide to using your phone with Cloud Voice

Suppliers' Information Note. BT LAN Extension Service Service Description

BT CLOUD VOICE COMMUNICATOR USER GUIDE.

Featureline Compact. Site User Guide To make an external call press 9 followed by the telephone number

BT One Phone. Yealink SIP-T46 phone user guide

UK s best selling phone brand. User Guide. BT Duet 210. Corded Phone

T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE

LinchPin. Managed Service For IP VPN Networks. Web Site Telephone

Yealink T48 IP phone. A guide to using your phone with Cloud Voice

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Quick Guide Internal wiring

Calculating the real cost of your phone system. Could you be getting more for your money with a cloud phone system?

Superfast fibre Connecting communities to the future

SIN 510 Issue 1.1 August 2016

BT Inspiration Hotel Facilities User Guide

Engage Meeting Manager. User guide

BT Duet 210. User Guide

Suppliers' Information Note BT LAN EXTENSION SERVICES 1, 2, 10 & 10 LOCAL REACH (LES 1, 2, 10 & 10LR) Service Description

BT Cloud Phone. App for Desk user guide. A user guide for running BT Cloud Phone with Desk.com customer service software.

UK s best selling phone brand. User Guide. BT Converse 2100 Corded Phone

Response 15. Userfriendly Guide

Response 5 answering machine

The right phones for your business. Programme your perfect phone with our customisable Mitel MiVoice 5300 handsets

Suppliers' Information Note. BT LAN Extension Service Service Description

BT Locate Affordable, local, secure data centres

BT Call Blocking. Pull out and keep

Cordless Additional Handset & Charger. User Guide

SIN 462 Issue 1.4 August 2016

BT Wholesale M2M Competitor Comparison

BT Q DECT Phone. 1 Display 2 Battery charge status 3 Display Keys 4 Control Key 5 Feature Keys 6 Dialpad 7 Microphone 8 Signal strength

WHOLESALE HOSTED CENTREX

USER MANUAL CAMPUS-RS FRACTIONAL INTERFACE CARD

OPENREACH WHOLESALE EXTENSION SERVICE 622 (WES622) AND WHOLESALE END TO END EXTENSION SERVICE 622 (WEES622) Service & Interface Description

Suppliers' Information Note BT CHANNEL EXTENSION SERVICE Service Description

SIN 459 Issue 1.6 August 2016

Phones that mean business. IP Office handsets and conference phones from Avaya

OPENREACH BACKHAUL EXTENSION SERVICES 10 (BES 10) Service & Interface Description

BT 8568 Digital Phone

MAINS DISTRIBUTION UNIT MDU14-CO

WHOLESALE HOSTED CENTREX

CA111x-series Arming Station

Relate 700. Caller Display Telephone. User guide

BT CONVERSE 2200 User Guide

Overview of features. Status LEDs

WE MAKE IT POSSIBLE. Data Services. Jargon Buster

Suppliers Information Note

SIN 508 Issue 1.2 August 2016

Decor 100. Userfriendly Guide

Size of Mounting Plate /2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards)

to 12a Added Standard and Electrical requirements for UL table 1.1

BT Cloud Phone. App for Desk administrator guide. An administrator guide for running BT Cloud Phone with Desk.com customer service software.

Nexgen Australia. Service Level Agreement

Conitel ASYNC Adapter

Suppliers Information Note. 21CN Optical Solution. Service & Interface Description

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

BT Big Button 100 Edition User Guide BT Big Button 100

Meridian 1 Fiber Remote Multi-IPE Interface Description, installation, and maintenance

BT Quantum. BT Quantum Components

Polycom VVX 300 and 400 series. A guide to using your phone with Cloud Phone

SIN 481 Issue 1.3 August 2016

Copyright 2000: PictureTel Corporation Printed in U.S.A. PictureTel Corporation, 100 Minuteman Road, Andover, MA

Ultrafast speeds with fibre infrastructure. A guide to installing fibre infrastructure in new residential developments

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION

FE1/10&100Base-T Bridge

BT ISDN 30 (DASS) Service Description

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

TALS 2. Torque Activated Logging System. Operating Instructions

LCI User Manual mantracourt.com

Using the operator panel

Transcription:

Private Circuits NETWORK TERMINATING UNIT 8 KiloStream N Private Circuits International KiloStream Private Circuits International MegaStream Private Circuits

To report a fault with your KiloStream private circuit, please ring your BT Service Centre on this number: Please quote: your circuit type your circuit number(s) your end address For International private circuits please ring the number provided in your customer handover information 2

Contents 1 About this guide 4 2 About NTU8 4 3 The equipment you ll see 5 Single NTU 5 Multiple NTU 6 4 Connections from the NTU 8 Connecting the NTU8 to the mains 8 Connecting your equipment to the NTU8 8 KiloStream N (voice) 8 Digital IPC (G703 presented) 9 Digital IPC (X21 presented) 10 KiloStream N (data) 10 Cabling distance 11 Configuration of the Service 11 5 Getting started 12 6 Testing your circuit 13 7 Looping your circuit 15 Testing the operation of your equipment 16 Testing the connection from the network 16 Testing the operation of the entire circuit 16 8 If you have a problem 17 9 How to report a fault 18 3

1 About this guide This Operating Guide gives information on Private Circuits including: Connecting your equipment to the Network Terminating Unit What the display means. How to test your line How to test your equipment. 2 About NTU8 A dedicated digital private circuit service, offering either data or voice transmission. The KiloStream N circuit A digital IPC The NTU8 is typically used on Nx64kbit/s Digital IPCs. (X.21 or G.703 presented International KiloStream/MegaStream). 4

3 The equipment you ll see BT s digital private circuits terminate at your premises on a network terminating unit (NTU) which is provided within the rental price. Any on-site wiring and equipment beyond the NTU is your responsibility and maintained by the relevant contractor. This may be BT or an independent supplier. One of our engineers will connect the NTU to the BT network using the ports on the NTU labelled as Local Line,TX and RX. If you alter these line connections in any way, you will set off remote alarms within the BT network and your service will be affected Single NTU If you have ordered a single private circuit, the unit is contained in a grey rectangular box. The lamps on the front of the unit, in conjunction with the liquid crystal display (LCD), show the operating state of the circuit. Front view of NTU8 single unit FAULT Customer Local Line TM RXD Menu Scroll Toggle Prog Local Loop Loop Back Rear view of NTU8 single unit NTU8A HDSL MODULE 240V 50Hz 8W Internal Fuse 100mA F O/P M x 64 I/P N x 64 TX Local Line RX HMI Port 5

Multiple NTUs If you have ordered a number of lines at one site, or a network of services, you may need shelf mounted NTUs. This installation normally consists of a series of NTUs in card form. Each card will be shelf mounted in a stacking system. There is only one LCD display for a multiple NTU installation. To select the NTU for which you want to display details on the LCD, press the appropriate NTU DISPLAY button. A yellow lamp confirms the NTU you ve selected. The LCD will continue to show information from that NTU until you press another DISPLAY button. Front view of NTU8 shelf mounted unit Connections to a multiple NTU8 installation should be made via the BT installed distribution panel 6

Close-up view of front of shelf mounted unit 7

4 Connections from the NTU Connecting the NTU8 to the mains The NTU8 is supplied with a three pin plug, fitted with a 3 amp fuse, for connection to a 13 amp mains supply. You should leave the power switched on at all times. The multiple NTU8 installation will typically be permanently wired to the power supply. Connecting your equipment to the NTU8 The following sections give details for connecting your terminal equipment, for either KiloStream N or International circuits, or either G703 (voice) or X21 (data). KiloStream N (voice) Connecting terminal equipment to the KiloStream N NTU8 (Voice) You should connect your terminal equipment to the NTU with two coaxial cables: one for transmission into the NTU and one for transmissions from the NTU. The ports for these cables are labelled as Mx64 I/P and O/P respectively. The physical interface is a BNC connector whose mating face conforms to BS9210 (N0001, part 2, fig 2). Your terminal equipment supplier should provide these cables. The electrical interface conforms to CCITT Recommendation G703. 8

Digital IPC (G703 presented) Connecting terminal equipment to the NTU8 (G703 presented) You should connect your terminal equipment to the NTU with two coaxial cables: one for transmission into the NTU and one for transmissions from the NTU. The ports for these cables are labelled as Mx64 I/P and O/P respectively. The physical interface is a BNC connector whose mating face conforms to BS9210 (N0001, part 2, fig 2). Your terminal equipment supplier should provide these cables. The electrical interface conforms to ITU-T Recommendation G703. 9

Digital IPC (X21 presented) Connecting terminal equipment to the NTU8 (X21 presented) You must connect your terminal equipment to the NTU with the correct type of cable using a 15-way D-type connector. Your terminal equipment supplier will normally provide this cable. KiloStream N (data) Connecting terminal equipment to the KiloStream N NTU8 (data) For the KiloStream N (data) service you must connect your terminal equipment to the NTU with the correct type of cable, using a 15-way D-type connector. Your terminal equipment supplier will normally provide this cable. 10

Cabling distance In order to achieve the best performance from your private circuit, the cabling distance between the NTU and your terminal equipment should not be more than 10 metres. If you have to relocate the terminal equipment at any time, please don t exceed this distance. Configuration of the service BT engineers have configured your circuit to the service option and circuit capacity that you specified when you ordered. Please note that your terminal equipment must also be configured to the same specification, otherwise the service will not function properly. You can check the configuration of your NTU by using the STATUS menu as shown in the section opposite, Getting started. 11

5 Getting started When we connect your private circuit, the LCD will show one of three menu headings: OPTIONS, STATUS or TEST. To change the LCD to the menu your require: press the up or down Scroll button. When you see the > symbol on the right of the LCD, there are further options available within the menu. To see these further options: press the Menu button. Examining the set-up of your NTU You can use the OPTIONS menu (which is display-only) to examine the set-up of your NTU. There are four messages: 0: CUSTOMER 0: PASSWORD 0: CLOCK 0: LOCAL LINE (for BT use only) (for BT use only) (for BT use only) (indicates alarm thresholds). Looking at the current status of your NTU You can use the STATUS menu (which is display-only) to examine the current operational status of the NTU in its normal state. There are five messages: S: CUSTOMER INTERFACE SETTING S: BIT RATE SETTING (in kbit/s) S: CUSTOMER INTERFACE ALARM STATUS S: LOCAL LINE INTERFACE ALARM STATUS S: G.821 STATS (for BT use only). 12

6 Testing your circuit You can test your private circuit in one of two ways: use the TEST menu to carry out straightforward tests use the Local Loop or Loop Back buttons to loop your private circuit. Using the TEST menu Use the TEST menu to test the NTU, apply a remote loop, or send binary data to the other end of the circuit. To change the LCD to the test you want: press the Toggle button; an asterisk appears in the LCD and the whole display flashes. To activate the test you ve selected: press the Prog button. To deactivate the test you ve selected: press the Toggle button press the Prog button. The actual options available within the TEST menu depend on the service option you ve chosen: voice (G703 or X21) or data. Both services have five options. 13

If you have voice/g703 14 select T: BINARY T: G821 LL STATS T: LOOP T: SELF TEST T: LAMP TEST If you have data/x21 select T: BINARY T: G821 LL STATS T: LOOP T: SELF TEST T: LAMP TEST to (not active for voice/g703) (for BT use only) apply or remove local loops on either all timeslots or individually selected timeslots; this operation is complex and you should only carry it out in conjunction with the relevant X-Stream Sevice Centre. Note that there is no remote loop facility available for KiloStream N voice cause the NTU to test itself (this doesn t interrupt data flow); if the NTU fails, the LCD displays SELF TEST FAIL. You should report this to the relevant X-Stream Service Centre momentarily illuminate all lights; this doesn t interrupt data flow to send constant binary 1s (or 0s if preferred) to the distant end of the circuit; this interrupts data flow (for BT use only) apply or remove a remote loop (a loopback at the distant NTU); this interrupts data flow. (Note: For international circuits it is not possible to call up a remote loop from your NTU8) cause the NTU to test itself (this doesn t interrupt data flow); if the NTU fails, the LCD displays SELF TEST FAIL. You should report this to the relevant X-Stream Service Centre momentarily illuminate all lights; this doesn t interrupt data flow

7 Looping your circuit You can use the Local Loop, and Loop Back buttons to help further with fault location. Types of test loop, national circuit International circuit Local looping allows you to test the operation of your equipment. Looping back helps BT engineers to test the connection from the network. 15

Testing the operation of your equipment To test the connection and operation of your equipment through the customer interface of the NTU, you need to install a local loop. To do this: press the Local Loop button to display LCD. CONFIRM LOOP? message on press the Prog button within three seconds. This applies a local loop and the TM and Local Loop lights are illuminated. To remove the loop: press the Local Loop button. Testing the connection from the network To test the connection from the network through the local end and the NTU, BT engineers may ask you to apply a loopback to help them locate the fault. To do this: press the Local Loop button to display LCD. CONFIRM LOOP? message on press the Prog button within three seconds. This applies a Loopback and the TM and Loop Back lights are illuminated. To remove the loop: press the Loop Back button. Testing the operation of the entire circuit To test the connection and operation of the entire circuit a loop needs to be applied at the distant end. To do this you will need to contact the distant end user and ask them to apply a loopback. 16

8 If you have a problem If you think there s a problem with your private circuit, you may try the checks below to try to solve the problem. If a fault proves to be in your terminal equipment or on-site wiring, rather than in the private circuit, BT reserves the right to charge for time spent on a visit to your premises: it s in your interest to carry out these checks first. symptom cause what you should do no lamps or blank LCD FAULT Local Line LED lit FAULT Customer LED lit TM LED lit no power to the NTU fault on circuit incorrect connection or loss of input to NTU from the local DTE the test function is active check that the power to the NTU is switched on check that all connections to the NTU are correct check all connections to the NTU and DTE; if symptoms persist consult your equipment supplier remove any loops or tests from the NTU at each end of the circuit If you can t solve the problem using the checks above, you may try to locate the problem within the circuit or your own terminal equipment. To do this, you may carry out the tests described in the section Testing your circuit. 17

9 How to report a fault BT has established X-Stream Service Centres to deal exclusively with maintaining KiloStream and MegaStream digital private circuits. Before you contact an X-Stream Service Centre, you should: ensure that the fault is in the private circuit or NTU and isn t due to your own wiring or terminal equipment ensure that all plugs are properly connected and that there is power to the equipment ensure that any non-bt maintained equipment is working carry out the tests described in the section Testing your circuit. If the fault is with the private circuit or the NTU, please telephone the nominated X-Stream Service Centre, as shown on the inside front cover of this guide. If the fault is with your International private circuit, please ring the number provided in your customer handover information. When you ring, you ll need to give the following information: the circuit reference number which you ll find on the cover of your NTU the name and telephone number of the person in your company whom we can contact while the fault is being traced; when the line is clear, we will inform the same person a description of the fault. BT X-Stream Service Centres are manned by specialist staff who have access to computer-aided facilities to speed the handling of any problem with your KiloStream private circuit; these facilities include access to alarm information. 18

The X-Stream Service Centre staff will keep you informed of progress made towards restoring your service, and will report back to you when service has been restored. You can report a problem at any time of the day or night, seven days a week, 365 days a year. If you report a problem outside normal office hours (0900 to 1700, Monday to Friday), you will need to state if access to your premises is available outside normal office hours. Note: X-Stream Service Centre staff don t have test access to equipment beyond your NTU, nor can they provide diagnostic information about equipment beyond your NTU. NTU8 are not used for American line coding, for T1 use B8ZS/AMI. 19

Offices worldwide The telecommunications services described in this publication are subject to availability and may be modified from time to time. Services and equipment are provided subject to British Telecommunications plc s respective standard conditions of contract. Nothing in this publication forms any part of any contract. BT and the BT logo are trademarks of British Telecommunications plc. British Telecommunications plc 2003 Registered office: 81 Newgate Street, London EC1A 7AJ Registered in England and Wales No: 4190816 Produced by stratauk.net Printed in England by Vitesse Printers Co Ltd PHME 44249/12/03 Printed on paper which meets international environmental standards