Product Summary. Display instrumentation for use in hazardous and safe areas. visit our website Loop Powered Indicators.

Similar documents
BA414DF Fieldbus indicator Single variable

BA684DF-P PROFIBUS PA Field mounting Fieldbus Display

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Wall-/Pipe Mounted Universal Process Indicator

100mm Process Indicator Recorder

BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

/8 DIN Universal Process Indicator

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3

Flow Measurement SITRANS F C

BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12

BA688CF-F FOUNDATION fieldbus Panel mounting Display

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

C160 Wall-/Pipe Mounted Universal Process Indicator

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

RT2Y Compact temperature switch intrinsic safety

BA505C 2-wire 4/20mA manual setpoint station Issue 6

Dräger Polytron 8200 Stationary gas detector (CatEx)

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

BA364D Intrinsically safe externally powered field mounting counter, timer, tachometer and clock Issue 10

/8 DIN Motorized Valve Controller

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

BA444DF-P PROFIBUS PA Intrinsically safe Field mounting 8 variable Fieldbus Indicator Issue 2

Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Hazardous Area Protection

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

BA627E-SS General purpose 2-wire 4/20mA rugged manual set point station

BA444NDF-F FOUNDATION fieldbus Type n Field mounting 8 variable Fieldbus Indicator Issue 3

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

MTL8000-2/x Series Modular I/O

red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection

S900 Remote I/O System Intrinsic safety in the field ABB

Flow Measurement SITRANS F C

Digital Indicator Solutions

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Flow Measurement SITRANS F US Clamp-on

Roxar CorrLog High Accuracy Corrosion Monitoring

Ultrasonic Flow Meter Brochure

5 Fieldbus Technology

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Variable Area Flowmeter DATASHEET

Roxar SandLog High Accuracy Sand/Erosion Monitoring

Digital electropneumatic positioner

NF760 Batch Controller

Intrinsically Safe Barriers

SITRANS F flowmeters SITRANS F US

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Intrinsically Safe Temperature Concentrator System

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

CombiView DFON Graphical display

Contents. Temperature & Process Measurement Indicators Setup Guide

S800 I/O ABB Automation

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Simplified information where and how you want it.

Rotary Measuring Technology

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Remote monitoring and display solutions

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

CONVERTER MC608 A/B/R/P/I. The Hybrid electronic converter for all applications DS300-1-USA

Description, continued

IHP24. Intelligent Hydraulic Positioner D HP- PL

DTM Distributed Transmitter Monitor

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Rotary Position Technology Incremental Encoders

Temperature process values at a glance

Bargraph for quick range overview The digital indicators provide a bargraph in addition to the digital display. This gives you all information

General Specifications

Rotary Measurement Technology Absolute Encoders, Singleturn

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field

The Fusion Series of Large displays

Intrinsically safe batch controller Batching Master 110i

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

MODCELL 2050R Single Loop Controllers

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection

Flow Measurement SITRANS F US Clamp-on

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

C100 Portable Multifunction

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Continuous level measurement Radar transmitters

Explosion-Proof Gauge Pressure Transmitter

General Specifications

Digital electropneumatic positioner

CALIBRATORS. BetaGauge II INTRINSICALLY SAFE MODEL AVAILABLE

Humidity goes Digital

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Transcription:

Product Summary Loop Powered Indicators Display instrumentation for use in hazardous and safe areas Panel Meters Set Point Stations [Generators] Rate Totalisers Counters Tachometers Timers or Clocks Serial Text Displays Fieldbus Indicators & Displays Flow Batch Controllers Indicating Temperature Transmitters Sounders & Beacons LED Cluster Lamps visit our website www.beka.co.uk

Loop Powered Digital Indicators Intrinsically safe Ex na Flameproof General purpose > A model for all applications Extensive range of loop powered indicators now includes compact field mounting models and unique stainless steel panel mounting indicators, which have Ex ia intrinsically safe and Ex na non sparking certification. > Large high contrast displays with a wide viewing angle Optional backlight can be loop or separately powered > Panel mounting models provide IP66 front of panel protection Two case sizes Stainless steel models Combined bargraph & digital models > Field mounting indicators have robust GRP IP66 enclosure Compact 'G' models 'E' models with separate terminal compartment > certification permits worldwide installation Ex ia intrinsic safety, Ex na non sparking & Ex t dust protection by enclosure. > Internal calibrator, root extractor, lineariser & tare function > Wide operating temperature > Accessories Dual alarms Pipe & panel mounting kits Scalecards Laser etched stainless steel legend plates Easy scale card installation without the need to remove indicator from the panel. (below) All 'G' suffix field mounting instruments have a slide-in scale card showing units of measurement and tagging. (below) TAG NUMBER SCALE 2-wire Tx P E Zener barrier or galvanic isolator circuit

Model No. Mounting Display Digits Bargraph Number Height Segments Length Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 BA304E* Field - separate 4 34mm No BA324E* Field - separate 5 29mm 31 83mm BA304G Field compact 4 34mm No BA324G Field compact 5 29mm 31 83mm BA307E Panel 96 x 48 4 15mm No BA308E Panel 144 x 72 4 34mm No BA327E Panel 96 x 48 5 11mm 31 44mm BA328E Panel 144 x 72 5 29mm 31 83mm BA326C Panel 144 x 48 Combined BA307E-SS** BA327E-SS** 4 5.5mm 100 95mm USA only 4 15mm No 5 11mm 31 44mm * and dust certification is an option ** allows installation in an Ex e or Ex p panel enclosure without invalidating enclosure certification Ex na & Ex tc - for use in Zones 2 and 22 without Zener barriers or galvanic isolators BA304NE Field - separate 4 34mm No BA324NE Field - separate 5 29mm 31 83mm BA304NG Field compact 4 34mm No BA324NG Field compact 5 29mm 31 83mm BA307NE BA327NE 4 15mm No 5 11mm 31 44mm Ex d Flameproof for use in Zones 1, 2. 21 and 22 BR323 Field 5 10mm No BA504E Field - separate BA524E Field - separate 4 34mm No 5 29mm 31 83mm BA504G Field compact 4 34mm No BA524G Field compact 5 29mm 31 83mm BA507E Panel 96 x 48 4 15mm No BA508E Panel 144 x 72 4 34mm No BA527E Panel 96 x 48 5 11mm 31 44mm BA528E Panel 144 x 72 5 29mm 31 83mm BA526C Panel 144 x 48 Combined BA507E-SS BA527E-SS 4 5.5mm 100 95mm 4 15mm No 5 11mm 31 44mm

Serial Text [Data] Displays Low cost operator interfaces which are ideal for simple machine and process control applications in hazardous and safe areas. > Intrinsically safe and general purpose models. > Field and panel mounting models with IP66 protection. > High contrast display with backlight, operator push buttons and two switch outputs. FREE simulation and ScreenWriter software > Selectable Modbus, BEKA or Legacy protocol. > General purpose models have RS232 or RS485 ports. > Displays up to eight variables on one of eleven standard screens, some with bargraphs. > Free BEKA ScreenWriter software simplifies design of custom screens. 6 5 4 3 2 1 1200 BA201 Communications isolator 0 kg RS232 or RS485 + 20 to 35V dc Optional external switches Model No. Mounting Operator buttons Communication Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 where certified BA484D Field 4 BA488C Panel 144 x 72 6 Via BEKA BA201 galvanic isolator BA684D Field 4 BA688C Panel 144 x 72 6 RS232 or RS485

Rate Totalisers An extensive new range of easy to use field and panel mounting instruments that can display rate and total flow in engineering units from most pulse or output flowmeters. > General purpose, intrinsically safe & Zone 2 internationally certified instruments. > IP66 field and panel mounting instruments. NEW 3rd generation instruments > Rugged stainless steel panel mounting models certified for installation in Ex e, Ex n, Ex p and Ex t enclosures. > Two input models can display sum or difference of inputs. > Optional backlight, isolated alarms and retransmitted pulse and outputs. Model No. Mounting Input Powered Display digits TOTAL RATE Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 where certified BA334G Field compact Pulse External 8 x 18mm 6 x 12mm BA334E Field - separate Pulse External 8 x 18mm 6 x 12mm BA337E Panel 96 x 48 Pulse External 8 x 9mm 6 x 6mm BA337E-SS* Pulse External 8 x 9mm 6 x 6mm BA338E Panel 144 x 72 Pulse External 8 x 18mm 6 x 12mm BA354E Field Loop 8 x 18mm 5 x 12mm BA358E Panel 144 x 72 Loop 8 x 18mm 5 x 12mm BA384G Field compact 2 x Pulse External 8 x 18mm 6 x 12mm BA384E Field - separate 2 x Pulse External 8 x 18mm 6 x 12mm BA388E Panel 144 x 72 2 x Pulse External 8 x 18mm 6 x 12mm * allows installation in an Ex e or Ex p panel enclosure without invalidating enclosure certification Ex na & Ex tc - for use in Zones 2 and 22 without Zener barriers or galvanic isolators BA334NG Field compact Pulse External 8 x 18mm 6 x 12mm BA337NE Pulse External 8 x 9mm 6 x 6mm BA384NG Field compact 2 x Pulse External 8 x 18mm 6 x 12mm BA354NE Field Loop 8 x 18mm 6 x 12mm BA534G Field compact Pulse External 8 x 18mm 6 x 12mm BA537E Panel 96 x 48 Pulse External 8 x 9mm 6 x 6mm BA537E-SS Pulse External 8 x 9mm 6 x 6mm BA538E Panel 144 x 72 Pulse External 8 x 18mm 6 x 12mm BA554E Field Loop 8 x 18mm 5 x 12mm BA558E Panel 144 x 72 Loop 8 x 18mm 5 x 12mm BA584G Field compact 2 x Pulse External 8 x 18mm 6 x 12mm BA588E Panel 144 x 72 2 x Pulse External 8 x 18mm 6 x 12mm

Counters New one and two input, easy to use externally powered counters which can display total and rate in engineering units from a wide variety of sensors including position indication from a quadrature encoder. > General purpose, intrinsically safe & Zone 2 internationally certified instruments. > IP66 panel and field mounting instruments > Rugged stainless steel panel mounting model certified for installation in Ex e, Ex n, Ex p and Ex t enclosures. > May be used with voltage, switch, open collector or proximity detector sensors. NEW 3rd generation instruments > Two input models can display sum or difference of inputs, or decode a quadrature encoder. > Optional backlight, isolated alarms, pulse and outputs. BA368E Scale card > Pulse output is synchronous with input pulse for retransmission. Proximity detector, magnetic pick-off, voltage pulse, switch contact, open collector sensors or quadrature encoder N A Isolated pulse output Zener barrier or galvanic isolator Power 24V dc S V b A b Quadrature encoder Typical intrinsic safety installation Model No. Mounting Input Powered Display digits TOTAL RATE Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 where certified BA364G Field compact 2 x Pulse External 8 x 18mm 6 x 12mm BA364E Field - separate 2 x Pulse External 8 x 18mm 6 x 12mm BA367E Panel 96 x 48 Pulse External 8 x 9mm 6 x 6mm BA367E-SS* Pulse External 8 x 9mm 6 x 6mm BA368E Panel 144 x 72 2 x Pulse External 8 x 18mm 6 x 12mm * allows installation in an Ex e or Ex p panel enclosure without invalidating enclosure certification Ex na & Ex tc - for use in Zones 2 and 22 without Zener barriers or galvanic isolators BA364NG Field compact 2 x Pulse External 8 x 18mm 6 x 12mm BA367NE Pulse External 8 x 9mm 6 x 6mm BA564G Field compact 2 x Pulse External 8 x 18mm 6 x 12mm BA567E Panel 96 x 48 Pulse External 8 x 9mm 6 x 6mm BA567E-SS Pulse External 8 x 9mm 6 x 6mm BA568E Panel 144 x 72 2 x Pulse External 8 x 18mm 6 x 12mm

Tachometers New easy to configure, externally powered instruments that measure and display speed in engineering units from a wide range of sensors. To assist with maintenance all models include a run-time display. > General purpose, intrinsically safe & Zone 2 internationally certified instruments. > IP66 panel and field mounting models > Rugged stainless steel panel mounting model certified for installation in Ex e, Ex n, Ex p and Ex t enclosures. > May be used with voltage, switch, open collector or proximity detector sensors. NEW 3rd generation instruments > Optional backlight, isolated alarms, pulse and outputs. > Synchronous isolated pulse output for retransmission. BA318E Scale card Proximity detector, magnetic pick-off, voltage pulse, switch contact or open collector sensors N Isolated pulse output Zener barrier or galvanic isolator Power 24V dc S V Typical intrinsic safety installation Model No. Mounting Input Powered Display digits SPEED RUN-TIME Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 where certified BA314G Field compact Pulse External 8 x 18mm 6 x 12mm BA314E Field - separate Pulse External 8 x 18mm 6 x 12mm BA317E Panel 96 x 48 Pulse External 8 x 9mm 6 x 6mm BA317E-SS* Pulse External 8 x 9mm 6 x 6mm BA318E Panel 144 x 72 Pulse External 8 x 18mm 6 x 12mm * allows installation in an Ex e or Ex p panel enclosure without invalidating enclosure certification Ex na & Ex tc - for use in Zones 2 and 22 without Zener barriers or galvanic isolators BA314NG Field compact Pulse External 8 x 18mm 6 x 12mm BA317NE Pulse External 8 x 9mm 6 x 6mm BA514G Field compact Pulse External 8 x 18mm 6 x 12mm BA517E Panel 96 x 48 Pulse External 8 x 9mm 6 x 6mm BA517E-SS Pulse External 8 x 9mm 6 x 6mm BA518E Panel 144 x 72 Pulse External 8 x 18mm 6 x 12mm

Timers or Clocks New one and two input externally powered instruments that can be easily configured as a Timer or as a Clock. As a Timer, they can measure the elapsed time between events or control events with the versatile easy to use state and event structure. As a Clock, local time can be displayed, and each of the two control outputs can be turned on and off twice in each 24 hour period. > General purpose, intrinsically safe & Zone 2 internationally certified instruments. > IP66 panel and field mounting models NEW 3rd generation instruments > Rugged stainless steel panel mounting model certified for installation in Ex e, Ex n, Ex p and Ex t enclosures. > May be used with voltage, switch, open collector or proximity detector sensors. > One and two input models BA378E Scale card Proximity detector, magnetic pick-off, voltage pulse, switch contact or open collector sensors N A Isolated status output Zener barrier or galvanic isolator Power 24V dc S V b Typical intrinsic safety installation Model No. Mounting Input Powered Display digits PRIMARY SECONDARY Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 where certified BA374G Field compact 2 x Sensors External 8 x 18mm 6 x 12mm BA374E Field - separate 2 x Sensors External 8 x 18mm 6 x 12mm BA377E Panel 96 x 48 Sensor External 8 x 9mm 6 x 6mm BA377E-SS* Sensor External 8 x 9mm 6 x 6mm BA378E Panel 144 x 72 2 x Sensors External 8 x 18mm 6 x 12mm * allows installation in an Ex e or Ex p panel enclosure without invalidating enclosure certification Ex na & Ex tc - for use in Zones 2 and 22 without Zener barriers or galvanic isolators BA374NG Field compact 2 x Sensors External 8 x 18mm 6 x 12mm BA377NE Sensor External 8 x 9mm 6 x 6mm BA574G Field compact 2 x Sensors External 8 x 18mm 6 x 12mm BA577E Panel 96 x 48 Sensor External 8 x 9mm 6 x 6mm BA577E-SS Sensor External 8 x 9mm 6 x 6mm BA578E Panel 144 x 72 2 x Sensors External 8 x 18mm 6 x 12mm

Fieldbus Indicators & Displays An extensive range of bus powered, single and eight variable Displays, Indicators and Listeners for use with FOUNDATION fieldbus and Profibus PA systems in hazardous or safe areas. FIELDBUS INDICATORS 5 digit 20mm high LCD digits with a 31 segment bargraph > Single variable FOUNDATION fieldbus models > 8 variable FOUNDATION fieldbus models which can be nodes or listeners. > 8 variable Profibus PA models which can be nodes or listeners. > Ex ic certification permits use with higher voltages in Zone 2. NEW FIELDBUS DISPLAYS Graphical display which can show up to 8 variables > Models for FOUNDATION fieldbus or Profibus PA applications. > Choice of 11 standard display screen formats, some with bargraphs. > Backlight > Push buttons for operator acknowledgements > 6 optional outputs One variable displayed at a time FISCO & FNICO compliant Up to eight variables may be displayed at a time FISCO compliant Model No. Mounting Variables Protocol Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 where certified INDICATORS BA414DF Field 1 FF BA444DF Node or Listener Field 8 FF or Profibus PA BA418CF Panel 1 FF BA448CF Node or Listener Panel 8 FF or Profibus PA DISPLAYS BA484DF Field 8 FF or Profibus PA BA488CF Panel 8 FF or Profibus PA Ex na & Ex tc - for use in Zones 2 and 22 without Zener barriers or galvanic isolators INDICATORS BA414NDF Field 1 FF BA444NDF Node or Listener Field 8 FF or Profibus PA INDICATORS BA614DF Field 1 FF BA644DF Node or Listener Field 8 FF or Profibus PA BA618CF Panel 1 FF BA488CF HAZARDOUS AREA 1 2 BA648CF Node or Listener Panel 8 FF or Profibus PA DISPLAYS FISCO Terminator Fieldbus FISCO Terminator FISCO Power Supply & Segment Coupler Host BA684DF Field 8 FF or Profibus PA BA688CF Panel 8 FF or Profibus PA FISCO Field Device FISCO Field Device

Flow Batch Controllers Very easy to use, stand alone batch controllers for dispensing or sampling. > Intrinsically safe and general purpose models. > Field and panel mounting with IP66 protection. > Easy to read graphical backlit display. > Pulse or input > Three configurable outputs for - Control - Flow alarm - Reset status - Batch status - Pulse output > Single or two stage control BA458C DISPLAY > 9 selectable batch setpoints > Overrun compensation Pulse or output from flowmeter Power supply 24V > Options Three additional outputs Flow Zener barriers or galvanic isolators Flowmeter Valve 2 Valve 1 Model No. Mounting Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 BA454D Field BA458C Panel BA654D Field BA658C Panel

Set Point Station [Generator] Ideal for manually adjusting process controller set points or process variables from within a hazardous or safe area using instrument's push buttons. These loop powered instruments incorporate an easy to read display showing the current in engineering units. > Intrinsically safe and general purpose models. > Rugged stainless steel panel mounting model certified for installation in Ex e, Ex n, Ex p and Ex t enclosures. NEW > Optional backlight which can be loop or separately powered. > BA490 Rotary Encoder enables manual analogue control of output as an alternative to operating instrument push buttons. NEW Set point Station BA427E Scale card Zener barrier or galvanic isolator Speed controller Set point input Adjusting speed controller set point from within hazardous area Shown with optional backlight Model No. Mounting Display digits NEW BA490 Rotary Encoder - optional Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 where certified BA427E Panel 96 x 48 5 x 11mm bargraph BA427E-SS 5 x 11mm bargraph BA627E Panel 96 x 48 5 x 11mm bargraph BA627E-SS 5 x 11mm bargraph

Indicating Temperature Transmitters Innovative field mounting loop powered, HART enabled, indicating temperature transmitters which eliminate the need for Zener barriers or galvanic isolators for many hazardous area applications. Zone 0, 1, 2, 20, 21 or 22 Zone 2 or 22 BA474D THC, mv or V RTD or R Intrinsically safe input BA474ND Optional alarm outputs circuit > Cost saving technique eliminates Zener barrier or galvanic isolators. THC, mv or V RTD or R Intrinsically safe input BA474D Optional alarm outputs circuit > 20mm easy to read display with optional backlight. > RTD, THC & voltage input > IP66 field and panel mounting models. THC, mv or V RTD or R Input Zener barriers or galvanic isolators Optional alarm outputs circuit > HART communication with sensor diagnostics. > Optional: Loop powered backlight Dual isolated alarms Model No. Mounting Ex i intrinsically safe - for use in Zones 0, 1 & 2 and 20, 21 & 22 where certified BA474D Field BA478C Panel 144 x 72 Ex na - intrinsically safe input BA474ND Field BA674D Field BA678C Panel 144 x 72

Ex d Sounders & Beacons A vast range of Ex d flameproof Sounders, Beacons and combined devices. and certified for use in gas and dust hazardous areas. Models for use with 24V dc, 115V ac or 230V ac supplies. SOUNDER > 32 different sounds > 3 stage alarm > Up to 123dBA output > IP67 enclosure BEACON > Red, Amber, Yellow, Green, Blue & White models > Up to 21 joule output > IP67 enclosure > Xenon flash or LED light source Panel Meters Cost effective general purpose panel meters built using the same high quality techniques developed for BEKA hazardous area instrumentation. Featuring high brightness LED displays with models for most types of process currents and voltages, including resistance thermometers and thermocouples. > 24V dc, 115V ac or 230V ac powered versions > IP65 front of panel protection > Adjustable brilliance > Optional dual alarms with NO/NC relay outputs > Optional isolated output > Optional isolated transmitter power supply A70 A75 A80 A85 Process input panel meter Factory set input type and range Universal input process input panel meter Input type selectable on-site Resistance thermometer input panel meter Single or differential temperature measurement and display in ºC or ºF Thermocouple or millivolt input panel meter Selectable type of thermocouple Model No. 24Vdc, 115V and 230Vac powered models A70 A75 A80 A85 NEW range available soon www.beka.co.uk Single range process meter Universal process meter RTD temperature meter THC input temperature meter

I.S. Sounders & Beacons High performance intrinsically safe sounder and flashing beacon in IP66 enclosures, may be used separately or as a pair powered from a single intrinsically safe circuit. Both are and US certified for use in gas hazardous areas. BR385 Sounder BA386 Beacon Zener barrier or galvanic isolator 24V dc Optional alarm accept push-button silences sounder for pre-set time while beacon continues to flash BR385 SOUNDER > 49 different sounds > 3 stage alarm > Up to 103dBA output > IP66 enclosure BA386 BEACON > Red, Amber, Green, Blue & White models > 2 double flashes per second > Alarm accept function silences sounder for pre-set time. Model No. Ex i intrinsically safe - for use in Zones 0, 1 & 2 BR385 Sounder BA386 Beacon I.S. LED Cluster Lamps Bright, low cost panel mounting lamps with IP66 front of panel protection which have a ten year life expectancy. All versions have, and US certification for use in gas hazardous areas. > Red, Amber, Green, Blue & White versions > BA390 has constant 20mA current consumption. > BA390S has specified performance at 4mA > BA599 rear sealing kit provides IP65 protection for lamp terminals includes cable gland. BA390S operates at only 4mA Model No. Ex i intrinsically safe - for use in Zones 0, 1 & 2 BA390 20mA constant current BA390S Low current specified performance at 4mA

Accessories 'D' and 'E' Field Instruments 'G' Field Instruments 'G' Field Instruments PIPE MOUNTING KITS BA392D Standard duty 316 stainless steel bracket secured by two stainless steel worm drive hose clips which attach instrument to any 60 to 80mm outside diameter vertical or horizontal pipe. Usually suitable for clamping to a 2 inch internal diameter metal pipe. D or E instrument PIPE MOUNTING KIT BA393G 316 stainless steel pipe mounting bracket attaches 'G' instruments to any vertical or horizontal pipe with an outside diameter between 40 and 73mm. Shown with optional legend plate (see right) 30mm 95mm EXTERNAL STAINLESS STEEL LEGEND PLATE For customers requiring traditional labelling, G instruments can be supplied with a laser etched stainless steel legend plate showing customer specified information. L E G E N D P L A T E 106 max BA392D pipe mounting kit 60 to 80mm BA393 Heavy duty 316 stainless steel pipe mounting bracket using a single V bolt which attaches instrument to any vertical or horizontal pipe with an outside diameter between 40 and 80mm. Will also support BEx series flameproof sounders and beacons. G instrument 93mm max 40 to 73mm PANEL MOUNTING KIT BA394G 316 stainless steel panel mounting kit secures 'G' instrument in panel aperature. G instrument TAG NUMBER SCALE Etched legend plate 'E' Panel Instruments and Advisors Includes instruments in 96 x 48 and 144 x 72mm plastic enclosures and mm rugged stainless steel enclosures. SLIDE IN SCALE CARD A slide-in scale card can be fitted without removing the instrument from the panel or opening the instrument enclosure. A customer specified scale card is a no cost accessory when an 'E' or Advisor instrument is ordered. A pack of 30 scale cards pre-printed with common legends is available for on-site configuration. D or E instrument Joint between instrument and panel is not sealed P E 100mm 60mm 330 SLIDE IN SCALE CARD All 'G' suffix field mounting instruments have a slide-in scale card which can accommodate scale and tag marking. If requested the instrument can be supplied with the scale card printed to show customer specified units of measurement, tag and application information. Slide-in scale card (below) Scale card for 'E' suffix instruments is inserted from the rear of the instrument. Pre-printed scale cards % %RH C F A bar barg FT FT-LBS gal in.wg kg kg/h kpa Litres L/h L/min L/s m³/h mbar M8 'V' bolt mbarg Pa ph psi rpm 106 max 40 to 80mm P E SPM t/h tonnes

Why Buy? > Three-Year warranty on all products > Fast manufacturing times, typically 3-5 working days > Widest range available of hazardous area indicators and displays > certifications for global applications > High reliability products for hazardous areas and general purpose applications > Privately owned by engineers designing products for engineers since 1984 > Direct telephone or email contact to sales team and knowledgeable engineers > Excellent customer support pre and post sales > World-wide support network of agents and distributors > Set-up and scale printing on most models for no additional charge > Comprehensive website and easy access to all documentation Asia Pacific South America Africa & The Middle East BEKA associates Ltd Old Charlton Road, Hitchin, Hertfordshire SG5 2DA England Telephone +44 (0) 1462 438301 Fax +44 (0) 1462 453971 www.beka.co.uk e-mail: sales@beka.co.uk Printed in EU 11-16