Prodigy Control System Premium Rooftop Unit Control

Similar documents
OPERATION MANUAL.

L Connection Network Control System For Energence Rooftop Units

Commercial Controls. Advanced control for saving time and money

Quick Start Guide DDC (2014/02) Subject to change without prior notice Quick Start Guide

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

ETM-2050/ETM-2051 Service Manual

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

V0STAT51P-2 Programmable Wired Controller

System Controls Suggested Specification

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Millennium Simplicity Elite Parameter Points and Quirks

SE7600E Series Application Guide

Smart Equipment Controls (SEC)

Installation and Operation Instructions

SE7600E Series Application Guide

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

BACnet Flow Controller for Fan Filter Units

Dual Digital Module Technical Guide

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

WSHP-IOP-2 May Installation, Operation, and Programming. Tracer ZN510 Controller

THERMOSTATS & CONTROLLERS

Fast Route to Reliable Energy Savings ZIP Economizer

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps

CONTROLLER INSTALLATION OPERATION & QUICK START

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.

TC-9102 Terminal Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Andover ContinuumTM. b3850 Series Terminal Controllers

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

Measure & Control Temperature & CO2 levels with analog & digital I/O

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL

MicroTech II Vertical Self-contained Systems Unit Controller

Siemens BACnet Programmable TEC Unit Conditioner Controller

MANUAL INSTALLATION + SERVICE. Price Intelligent Controller. PIC Series. v400 Issue Date: 12/18/ Price Industries Limited. All rights reserved.

TAC Xenta 121-HP Programmable Heat Pump Application

Siemens BACnet Programmable TEC Constant Volume

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

VZ7000 Series. BACnet Commercial Zoning System

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

FCU-4 FAN COIL CONTROLLER

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

SEZ7000 Series. Wireless Commercial Zoning System

ECON-ZIP-BASE. ZIP Economizer Base Module

Description. descriptors, makes set-up and monitoring very user friendly.

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Economizer Controller Installation Guide

Custom Controller Installation Instructions

M1000 INTELLIGENT ZONE CONTROL SYSTEM

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

BACnet MS/TP Interface User s Guide

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Installation, Start-up and Operating Instructions

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

Field selectable application type and room module series, via dip-switches on controller

CommandCenter Operator Panel

FX 2 Instruction Manual

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

ECONOMIZERS. Z1ECON30B-1 ECONOMIZER (Cat No. 10Z29) INSTALLATION INSTRUCTIONS FOR ECONOMIZERS USED WITH ZC,ZG,ZH UNITS CAUTION WARNING

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

SEZ7656R1045B / SEZ7656H1045B

BACnet. b3867 Terminal Controllers

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

Tracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. January 2005

Table of Contents. RTU Open Controller

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

TAC Xenta 121-FC Programmable Fan Coil Application

Installation, operating and maintenance ADALINK II. Web solution for LENNOX units supervision ADALINK II-IOM-1401-E. lennoxemeia.

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

SEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

Building Energy Management Training Systems

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

Underfloor Controllers

PoolPak MPK with CommandPak Control System CPCS BACnet /IP User s Guide DOCUMENT #: SVW07-MPKBACNIP

4-step Chiller and Heat Pump Controller

Warning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M

Introduction. What is the RTU Open controller?

32MP Gateway. Overview and Configuration Manual

Siemens BACnet Programmable TEC Unit Vent Controller

SED2 Variable Frequency Drives

Product Data. SYSTXCCITW01---A, SYSTXCCITC01---A & SYSTXCCITN01---A Infinityr Touch Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR TOUCH CONTROL

DataNab it8: Intelligent Communicating Thermostat

Specification Sheet For electronically commutated motors

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Datasheet. ECB-600 and ECx-400 Series. ECB-600 & ECx-400. Overview. Applications. Features & Benefits.

Product Data. Features/Benefits. 50RLP Water Source Heat Pumps System Control Panel

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

IntesisBox ModBus RTU Fujitsu Air Conditioning

BACnet Terminal Box (VAV) Controller

Transcription:

CONTROLS Prodigy Control System Premium Rooftop Unit Control Bulletin No. 210537 February 2010 Supersedes January 2010 L E N N O X L E N N O X L E N N O X OVERVIEW The Prodigy Control System intelligently controls every Lennox Energence rooftop unit. This control system provides all control functions for the unit, ensuring safe and reliable operation. Unit status information and unit diagnostics are displayed in plain English by the control system to facilitate troubleshooting. Although default operation does not require programming, the control system has programmable parameters that allow adjustment of time delays and setpoints that enable many advanced features. The default operation requires a standard room thermostat or direct digital controller (DDC). By changing one parameter, the control system will also control the unit from a Comfort Sensor or zone temperature sensor. The Prodigy Unit Controller is a network controller when daisy chained to the L Connection Network Control System. For ease of configuration, the Prodigy Unit Controller can be connected to a PC with Unit Controller PC software installed. The Prodigy Control System is comprised of the powerful Prodigy Unit Controller and the intuitive SmartWire System.

FEATURES AND BENEFITS PRODIGY UNIT CONTROLLER The Prodigy Unit Controller is a microprocessor-based control board that provides flexible control of all unit functions. All control voltage is provided via a 24V (secondary) transformer with built-in circuit breaker protection. Built-in functions include: Blower On/Off Delay - Adjustable time delay between blower on and off. Built-in Control Parameter Defaults - No programming required. The Prodigy Unit Controller features: Scrolling Display - Display scrolls full text instead of numerical codes to help simplify diagnosing and troubleshooting. The high contrast display makes it easy to read in various lighting and ambient conditions. Push Buttons - Offer simplified navigation during setup and diagnostics. Arrow buttons (no DIP switches) simplify setup and installation by making menu navigation very intuitive Guided Setup - The Prodigy Unit Controller features a guided setup procedure that speeds up and helps insure proper installation and setup of the rooftop unit. USB Port - Allows a technician or user to easily download and transfer unit information (with a time/date stamp and unit serial number) via a USB flash drive to help verify service was performed. A second USB port also offers an easy interface with a PC and the Lennox Unit Controller Software. Unit Profile - A Unit Profile can also be saved to a USB flash drive and then uploaded to an identical unit, instantly copying all setpoints. Self-Test - Unit Controller performs self-test to verify individual critical component and system performance. Included is an economizer test function that helps assure the economizer is operating correctly. Time Clock with Run-time Information - Internal time clock with runtime information on these key components: Power Applied Filter Blower Belt UV Lamp Blower Compressor(s) Condenser Fan(s) Heat Stage(s) Free Cooling Exhaust Fan Dehumidification Prodigy Control System / Page 2 Compressor Time-Off Delay - Adjustable time delay between compressor shutoff and start up. DDC Compatible - Various third party DDC controllers can be factory or field installed. Dirty Filter Switch Input - When a Dirty Filter Switch is installed, the control will signal when the indoor blower static pressure increases, indicating a dirty filter condition. Switch is optional and can be factory or field installed. Discharge Air Temperature Control - The controller will cycle up to 4 stages of heating or cooling to maintain the discharge air setpoints for heating or cooling. Optional sensor for remote field installation in the supply duct. Display/Sensor Readout - Displays control parameters, text status messages, and sensor readings. The unit controller displays temperature readings from return air, supply air, and outdoor air sensors that are furnished as standard on all Energence units. Controller will also display readings from optional sensors such as zone sensors, CO 2 sensors or relative humidity sensors. Economizer Control Choice - The economizer is controlled by the Prodigy Unit Controller. The control has several options for controlling the economizer.

FEATURES AND BENEFITS Fresh Air Tempering - Provides heating and cooling as needed to maintain the supply air temperature within a comfort range, regardless of the thermostat demand. Sensor ships with unit but must be field installed in the supply air duct. Requires change to setpoint in the field to activate this mode of operation Extensive Unit Diagnostics - The Prodigy Unit Controller monitors all sensors and functions related to unit operation to provide critical information. The controller will display detailed diagnostic information with over 100 diagnostic and status messages to pinpoint any problems and reduce troubleshooting time. All diagnostic messages and status alarms are displayed in plain English. Exhaust Fan Control Modes - Fans controlled by fresh air damper position or building static differential pressure transducer. Permanent Diagnostic Code Storage - Stores last 84 diagnostic messages even in the event of a power failure. Field Changeable Control Setpoints - Over 200 different control setpoints allow customizing of the unit operation by changing delays, cooling stages, deadbands, and other comfort control parameters. Indoor Air Quality Input - The Prodigy Unit Controller is Demand Control Ventilation ready from the factory (optional field installed CO 2 sensor required). Two modes of operation are available: setpoint and proportional. 1. Setpoint - Opens the economizer dampers to full position when CO 2 setpoint level is reached. 2. Proportional - Opens the dampers at the first set point and gradually increases it as the CO 2 level increases until the second setpoint is reached. Low Ambient Controls - Allows unit cooling operation down to 0 F. Gas Valve Time Delay Between First and Second Stage - Allows gradual increase of input rate. Minimum Compressor Run Time - Ensures proper oil return to the compressor. Network Capable - The Prodigy Unit Controller can be daisy chained to other Energence Rooftop Units or the L Connection Network Control System using twisted pair wire. Night Setback Mode - Adjusts setpoints, closes outdoor air dampers and operates the blower on demand, may be customized for special requirements. Return Air Temperature Limit Control - Allows the user to override the demands based upon the return air temperature during either heating or cooling operation. Helps protect against abnormal operating conditions in the event of a room sensor or thermostat failure. Safety Switch Input - Normally-closed digital input allows the Prodigy Unit Controller to respond to a external safety switch trip (phase protector, low voltage, etc.) shutting down unit operation. Service Relay Output - Digital output can indicate a critical error has occurred to an external control device. Can also be configured to energize based on relative humidity, indoor air quality, outdoor air temperature or unit operation. Smoke Alarm Mode - Control board has four choices for responding to a smoke alarm. 1. Unit Off - unit will turn off. 2. Positive Pressure - blower is energized, exhaust fan is de-energized, and the outdoor air dampers are opened. 3. Negative Pressure - blower is energized, exhaust fan is energized, and the outdoor air dampers are closed. 4. Purge - blower is energized, exhaust fan is energized, and the outdoor air dampers are opened. Staging - 2 heat/2 cool. Capable of up to 4 heat/4 cool with zone sensor or third party DDC control system. Strike Three Protection - Ends cooling or heating operation when any of the following occurs three times (adjustable) within a thermostat cycle: low pressure trip, high pressure trip, heat limit trip, blower proving, or freezestat trip. Gas Reheat - Control parameter option that allows simultaneous heating and cooling operation for controlling humidity for process air applications such as supermarkets. Field installed relative humidity sensor or dehumidistat can be used. On Demand Dehumidification - Monitors and controls condenser hot gas bypass operation with Humiditrol option. Prioritizes heat and cool demand with dehumidification demand. Reheat demand can be enabled by digital input or a field installed relative humidity sensor can be used. Thermostat Bounce Delay - Protects compressor from short cycling when mechanical thermostat is used. Warm Up Mode Delay - Adjustable time that the economizer dampers are kept in the closed position during morning warm-up. LED Indicators - For L Connection Network (transmit and receive) and for each thermostat input. PC Interface - PC with optional Unit Controller software may be used to field or remotely adjust parameters, read alarms, or display unit status. Zone Sensor Operation - Controls zone temperature with up to 4 stages of heating or cooling with optional zone sensor. Prodigy Control System / Page 3

FEATURES AND BENEFITS OPTIONS / ACCESSORIES Factory or Field Installed Blower Proving Switch Monitors blower operation, shuts down unit if blower fails. Dirty Filter Switch Senses static pressure increase indicating dirty filter condition. CONTROLS OPTIONS / ACCESSORIES Factory or Field Installed Fresh Air Tempering Used in applications with high outside air requirements. The Prodigy Unit Controller energizes the first stage heat as needed to maintain a minimum supply air temperature for comfort, regardless of the thermostat demand. When ordered as a factory option, the sensor ships with the unit but must be field installed. Smoke Detector Photoelectric type, installed in supply air section, return air section or both sections. Available with power board and single sensor (supply or return) or power board and two sensors (supply and return). Power board is located in rooftop unit control box. Interoperability via BACnet or LonTalk Protocols Communication compatible with third-party automation systems that support the BACnet Application Specific Controller device profile, LonMark Space Comfort Controller functional profile, or LonMark Discharge Air Controller functional profile. The Lennox BACnet module has been tested and is listed with BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test prod BACnet Testing Laboratories (BTL). for compliance with ASHRAE standards. Compliance of listed products to requirements of AS Standard 135 is the responsibility of the BACnet Manufactures Association (BMA). BTL is a regi trademark of the BMA Commercial Control Systems L Connection Network Control System Complete building automation control system for single or multi-zone applications. Options include local interface, software for local or remote communication, and hardware for networking other control functions. See L Connection Network Control System Engineering Handbook Bulletin for details. Aftermarket DDC Novar Unit Controller and options. Thermostats Control system and thermostat options. Aftermarket unit controller options. Field Installed Humidity Sensor Kit Humidity sensor required with factory installed Humiditrol dehumidification option or Supermarket reheat field selectable option. SMARTWIRE SYSTEM Part of the Prodigy Control System, the SmartWire System features color coded, keyed, and labeled connectors which improve and simplify unit setup. Easy connection of field sensors and accessories reduces installation and setup time. Uniform Wiring Color Scheme All Energence rooftop units have a common wiring scheme which eliminates any wiring differences between models. If a certain color belongs to a wiring group of one Energence unit it will be the same on all other models or sizes. Labels On Wiring Connections The SmartWire System features easy to read and understand labels on all important wiring connections. This reduces installation and service time and helps assure they are wired correctly. Improved Wire Routing The SmartWire System wire routing simplifies servicing and troubleshooting by keeping it easy to trace each wire s path. Prodigy Control System / Page 4

MAIN CONTROL BOARD MAIN CONTROL BOARD DETAIL ALARMS Use arrows to move TEST Push to select or enter value; then use arrows DISPLAY SERVICE DATA SETTINGS RUNTIME UNIT DISPLAY DISPLAY USB USB INTERFACE INTERFACE PORT PORT (For Flash Drive STATUS MODE CALLS OFFLINE IN/OUTPUTS REPLACE HISTORY SENSORS NETWORK SETPOINTS CONTROL OPTIONS USER USER INTERFACE INTERFACE NAVIGATION NAVIGATION ARROWS ARROWS SELECT SELECT BUTTON BUTTON USB REPORT FACTORY INSTALL M2 UNIT CONTROLLER BACnet Listed USB CONNECTION (for Unit Controller software) L CONNECTION ( optional connection method for Unit Controller software) SMARTWIRE CONNECTORS MAIN CONTROL BOARD DETAILED COMPONENT VIEW CONTROL BOARD CONTROL BOARD EXPANSION PORT EXPANSION PORT USB CONNECTION (for Unit Controller software) L CONNECTION ( optional connection method for Unit Controller software) ECONOMIZER POTS AND DIP SWITCHES (PAGE 20) 2 AMP FUSE Prodigy Control System / Page 5

USER INTERFACE USER INTERFACE MENU TOP LEVEL DETAILS NOTE Use the left button during normal operation to clear delays (hold 2 seconds) or reset the controller (5 seconds). Dashed line for automatic displayed messages DISPLAY SERVICE DATA SETTINGS ALARMS TEST RUNTIME UNIT STATUS MODE Use arrows to move OFFLINE IN / OUTPUTS Use arrows to move HISTORY SENSORS Use arrows to move SETPOINTS CONTROL Use arrows to move CALLS REPLACE NETWORK OPTIONS USB REPORT FACTORY INSTALL Prodigy Control System / Page 6

USER INTERFACE USER INTERFACE - SUB-MENU LEVELS Table below shows the major levels of the menu interface. Many of these options have more levels and are described in the following sections that detail DISPLAY, SERVICE, DATA, and SETTINGS. Use recangular button to progress to next lower level (i.e. Level 1 to Level 2). Use left arrow to back up to the next higher level (i.e. Level 2 to Level 1). Use the up/down arrows to move within a level and change valus of selected items. Menu Interface Level 1 Level 2 Level 3 NOTE Features and options not currently available are greyed out in (display area) ROWS TO M MOVE O USE AR R ALARM STATUS MODE CALLS USB TEST OFFLINE IN / OUTPUTS REPLACE REPORT SILENCE (push any button to silence) SILENCE (push any button to silence) COMP LOAD SHEDDING COOLING DEHUMIDIFICA- TION FAN ONLY FREE COOLING FRESH AIR COOL FRESH AIR HEAT HEATING HVAC OFF IDLE TSTAT Y1, etc BACNET Y1, etc LONTALK Y1, etc WRITING USB WRITING ALARM/STATUS LOG USB COMPLETE GUIDED BLOWER FANS COOL HEAT DAMPER REHEAT SENSORS OUTPUTS CONTROLLER LOCKOUT BLOWER ONLY COOLING ONLY HEATING ONLY RESET ZONING SENSORS RELAYS NETWORK OUTPUTS FILTER BELT UV LAMP FANS BLOWER COMPRESSOR MAKE REPORT READ INSTALL READ FACTORY LOW AMBIENT LOCKOUT MORNING WARMUP M2 FAILED TO RESPOND M2 RESET OFF ON ALARM PRE COOL PRE INSTALL RESTARTING.. SMOKE TEST LCONN Y1, etc BUILDING Y1, etc Menu Interface (cont d) Level 1 Level 2 Level 3 DATA SET- TINGS TO MOVE USE ARROWS E ARROWS TO MOVE US E RUNTIME S HISTORY SENSORS (also accessible thru In / Outputs) NETWOR K FACTORY UNIT SER- VICE SET- POINTS CONTROL OPTIONS POWER ON FILTER: XX HRS BELT: XX HRS UV LAMP: XX HRS BLOWER: XX HRS XX CYC COOLING HEATING FREE COOLING: XX HRS XX CYC FANS EXHAUST REHEAT: XX HRS XX CYC ALARMS STATUS LAST USB READ INSTALL RPT CLEAR HISTORY TSTAT BRPM:XX DPOS:XX% OAT:XXºF RAT:XXºF DAT:XXºF ZAT:XXºF IAQ:XX PPM LCONN ADDRESS BACNET ADDRESS LONTALK ADDRESS SMK:OFF/ON RH:XX% IE:XX MA OE:XX MA GLO:OFF/ON DI2:OFF/ON DI3:OFF/ON DI4:OFF/ON READ M2 SOFTWARE VERSION READ DB SOFTWARE VERSION READ FACTORY RPT CATALOG NO. MODEL NO. SERIAL NO. UNIT NO. DATE/TIME UNITS F/C COOLING HEATING DAMPER REHEAT EXHAUST IAQ GUIDED SETUP LOCAL THERMOSTAT LCONN BACNET LONTALK MSAV REHEAT SMOKE MODE ECTO RESERVED INSTALL NEW M2 DAMPER FLOAT SW BLOWER PROVING SW PHASE MONITOR UV LAMP ELECTRIC HEAT STAGES UPDATE DISPLAY SOFTWARE Prodigy Control System / Page 7

REPORTING SAMPLE USB SERVICE REPORT USB SERVICE REPORT ========================================================================== Service Date 09/10/2009 Service Time 13:22:01 Serial No. SN NOT SET M2 Version 6.92.30 DB1Version 0.09 Unit No. 12 Unit Address 1 BACnet Address. 1 CAT No. 1 Description No Description ========================================================================== Runtime Data Total Power On 95 HRS 1 CYCLES Before Install 95 HRS Filter 0 HRS Belt 0 HRS Blower 0 HRS 0 CYCLES Compressor 1 0 HRS 0 CYCLES Compressor 2 0 HRS 0 CYCLES Compressor 3 0 HRS 0 CYCLES Compressor 4 0 HRS 0 CYCLES Outdoor Fan 1 0 HRS 0 CYCLES Outdoor Fan 2 0 HRS 0 CYCLES Outdoor Fan 3 0 HRS 0 CYCLES Outdoor Fan 4 0 HRS 0 CYCLES Outdoor Fan 5 0 HRS 0 CYCLES Outdoor Fan 6 0 HRS 0 CYCLES Heat Stage 1 0 HRS 0 CYCLES Heat Stage 2 0 HRS 0 CYCLES Reheat 0 HRS 0 CYCLES Free Cooling 0 HRS 0 CYCLES UV Lamp 0 HRS ========================================================================== Sensor Data OAT : 1 degf RAT : 0 degf DAT : 0 degf ZAT : 64 degf RH : 0 % CO2 : 0 ppm ========================================================================== Alarm/Status Log (12) 01.01.1970 00:00:00 COMP 1 HIGH PRESS S4 (32) 01.01.1970 00:00:00 COMP 1 FRZSTAT OPEN S49 (50) 01.01.1970 00:00:00 PRIMARY HEAT 1 LIMIT OPEN NOTE GAS OR ELECTRIC (82) 01.01.1970 00:00:05 CONTROLLER RESET (83) 01.01.1970 00:00:00 (118) 01.01.1970 00:00:00 (12) 01.01.1970 00:00:00 COMP 1 HIGH PRESS S4 (32) 01.01.1970 00:00:05 COMP 1 FRZSTAT OPEN S49 (50) 01.01.1970 00:00:00 PRIMARY HEAT 1 LIMIT OPEN NOTE GAS OR ELECTRIC (82) 01.01.1970 00:00:00 CONTROLLER RESET (83) 01.01.1970 00:00:00 (118) 01.01.1970 00:00:05 (12) 01.01.1970 00:00:00 COMP 1 HIGH PRESS S4 (32) 01.01.1970 00:00:00 COMP 1 FRZSTAT OPEN S49 (50) 01.01.1970 00:00:00 PRIMARY HEAT 1 LIMIT OPEN NOTE GAS OR ELECTRIC (82) 01.01.1970 00:00:05 CONTROLLER RESET ========================================================================== END OF REPORT Prodigy Control System / Page 8

SPECIFICATIONS Operating Environment Temperature: -40 F to 155 F Humidity: 10% - 95% RH, Non- Condensing Power Requirements 24VAC (+/-25%), 50/60Hz 4.8 VA for M2 maximum 14.4 VA for M2 w/all expansion boards Maximum Memory Type Device Commissioning Unit type Re-programmable Flash Auto-poll (real plug and play) Electric/Electric, Gas/Electric & Heat Pumps (Rooftops) Cooling stages 4 Heating stages 4 Modulating Gas Valves 2 Electronic Configure To Order Parameters 239 Alarm Codes 107 Alarm Codes Stored 84 Display Type Indicator LEDs Scrolling, 7 plus Character Red LED 1- Heartbeat on each board 1- Bus transmit 1 - Bus receive 1- each for Y1,Y2,W1,W2,G,OCP Dimensions - Main Board Main Board: Height: 8 in., Width: 14-1/2 in., Depth: 6 in. Weight 2 lbs. for M2 w/all modules installed Cable Type SysBus - Lennox yellow COMM cable: C0MISC00AE1- (27M19) (500 ft. box), C0MISC04AE1- (94L63) (1000 ft. box), C0MISC01AE1- (68M25) (2500 ft. roll) ZoneBus - Lennox purple COMM cable: C0MISC05AE1- (23W99) (500 ft. box) C0MISC06AE1- (24W00) (1000 ft Prodigy Control System / Page 9

INPUTS / OUTPUTS INPUTS / OUTPUTS (M2 MAIN BOARD) Bus Port Expansion Ports Digital Outputs Digital Inputs Analog Inputs Temperature Inputs INPUTS / OUTPUTS (M2 VAV, MODULATING GAS AND I/O MODULES) For Energence 092 through 600 (7.5 through 50 Ton) Models Only Expansion Ports Digital Outputs Digital Inputs Analog Inputs Analog Outputs INPUTS / OUTPUTS (M2 #3 and #4 COMPRESSOR MODULE) Expansion Ports Digital Outputs Digital Inputs INPUTS / OUTPUTS (MOTOR CONTROL MODULE) Expansion Ports Digital Outputs Digital Inputs Analog Outputs Lennox SysBus, EIA-485, 9600 baud (SmartWire wiring terminal block and phone jack ) USB Communication Port 3 expansion ports for adding up to 5 expansion boards 15 digital outputs (2 Amps Max) 27 (24VAC), 6 (5VDC) 5 analog inputs (0-10VDC or 4-20 ma) 4 temperature inputs (thermistor type). Outdoor Air, Return Air, Discharge Air and Zone. 1 expansion port 1 relay output (1 Amps Max) 2 digital inputs (24VAC) 4 analog inputs (0 to 10VDC) 2 analog outputs (0 to 10VDC) 1 expansion port 6 relay output (2 Amps Max) 8 digital inputs (24VAC) 1 expansion port 3 digital inputs 1 digital input, frequency 2 analog outputs (includes pwm) M2 BACNET MODULE Refer to M2 BACnet Module Service Literature, Corp. 0926-L11. M2 LONTALK MODULE Refer to IMC LonTalk Module Service Literature, Corp. 0927-L5. Prodigy Control System / Page 10

Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2010 Lennox Industries, Inc.