BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE

Similar documents
PEREGRINE SERIES RETROFIT INSTALLATION GUIDE

CHANNEL LETTER LIGHTING UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

OT DMX RGB Installation Guide

WARNING. General Information

Principal LED Street Stik Fluorescent Bulb Replacements

Principal LED Qwik Stik Fluorescent Bulb Replacements

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201

M215 (M215-60) Safety

M250 (M LL) Safety

E1135C PDU and Pod Upgrade Procedure

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

PrevaLED Troffer. Snap board feature allows for customizable lengths. Light is OSRAM.

Enphase S-Series Microinverter and Engage Cable Safety

Installing a Power over Ethernet injector

WARNING ELECTRICAL SHOCK HAZARD

Ink-Dot Series II Driver

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

527F Dual PC Option Installation Guide as replacement for 32MP made by Fadal

M215-Z Safety Information (M LL-IG-ZC)

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Operating instructions. Switching amplifier DN0210 DN / / 2015

SAVE THESE INSTRUCTIONS

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Twisted Nitro Stunt Racing New Cabinet Design with Sintra Marquee Supplement to Operation & Service Manual

810D Series FAA L-810 Double Obstruction Light Installation Manual

Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2

Installation and Operations Manual. Electronic copies available at (Rev_ )

PowerLogic High Density Metering System 1-Meter Enclosure

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Replacing the Power Supply

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

MCG Surge Protection

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Megatouch FORCE Monitor Chassis Board Replacement

LINEARlight FLEX Accessories

PV Rapid Shutdown device

Linearray PD Retrofit Kit

PANEL MOUNT INTERCOMS

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PXC Compact Unitary Equipment Controller (UEC)

Installation Instructions

Series 3700 Screw Terminal Assemblies Installation Instructions

ExpressCard Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure. September 22, 2014

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Operating Instructions

-Verify that supply wiring voltage matches power supply voltage by comparing it with power supply label.

Standard icontrol Power Supply Kit

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

REMOTE HEAD ADAPTER INSTALLATION GUIDE

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

CAUTION READ CAREFULLY

AutoScan to MultiScan Replacement Kit

INSTALLATION INSTRUCTIONS

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date:

GPIB-232CT-A IBCL EPROM Installation Guide

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Broadband Automatic Disconnect Switch. User Manual

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

TRC-190 User s Manual

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

OPLC Installation Guide

Panduit Basic Rack PDU


EcoFlex LED Neon Manual

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

SM Sygnus Hybrid Quick Installation Guide Version

G5 PDU Installation Guide

Lightning Stitch Assembly

TRC-190 User s Manual

Pit Transition with 24" Fan Installation and Operators Instruction Manual

ILC LightLEEDer MicroLite 1000P Retrofit Installation

PS/IO Circuit Board Retrofit

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Panduit Basic Rack PDU with Local Meter

Carefully remove the translite from the backbox and then lower the speaker panel to the position shown in Fig. A to gain access to the backbox.

Operating instructions IO-Link master CabinetLine AL19xx

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Plasma Panel Replacement Guide DU-42PX12X

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

PICO PROTECTOR PG-06 & PK-06 Series

Installing and Configuring Rialto Analytic Appliances

Mounting on the Ceiling Using Flush Mount (Face Down)

To connect the AC adapter:

Replacing the Gateway M275 Keyboard

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Blackout Shutter Kits with Breathable Wall Light Traps

JAN 16 Rev B

BRB Systems USA Co. Instruction Manual. USA Trap Solo Voice Release System. 12V & 120V Versions.

Transcription:

www.osram-americas.com/signage BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE PERFORMING INSTALLATION OF THE POWER SUPPLIES, MODULES, AND/OR RGB CONTROLLERS. Failure to install the power supplies and/or LED modules in accordance with the National Electric Code (NEC), all applicable Federal, State, and local electric codes as well as the specific Underwriters Laboratories (UL) safety standards for the installation, location and application may cause serious personal injury, death, property damage and/or product malfunction. These instructions are guidelines for installation of LED modules and power supplies. Installation requirements may vary depending on the application. Licensed electricians should provide all installation services for connection for both primary and secondary (input/output) of the power supplies. RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS E311887 3SNE 1.0 PREPARE FOR INSTALLATION 1.1 Tools Required: - Wire stripper/cutter - Screwdriver - Measuring tape 1.2 Supplies Required: - PLTC cable - Wire nuts/connectors - #8 screws or rivets - Accessory Mounting Track and Brackets 1.3 Carefully remove existing neon or fluorescent tubes, HID or incandescent light sources and power supplies and/or ballasts if necessary. 1.3.1 Make sure power is turned off. a. Where applicable, determine if a disconnect switch needs to be installed (may be integral with existing power supply/transformer). 1.3.2 Remove all existing screws, sockets and wiring. 1.3.3 Dispose of all old sign components in the proper manner. 1.3.4 Repair and seal any unused openings in the sign enclosure. Openings greater than ½ diameter require a metal patch secured by screws or rivets and caulked with nonhardening caulk. Smaller openings may be sealed with non-hardening caulk. 1.3.5 Clean the inside of the sign to make sure it is free of dirt. LED340

2.0 MECHANICAL INSTRUCTIONS 2.1 Refer to desired module layout 2.2 Measure inside cabinet dimensions 3 2.3 Required track lengths

2.4 Cut the two b track segments to length be certain the dimension d on both track pieces is the same to ensure the tracks are parallel in the case 2.5 Attach the two b track segments to the sides of the case

2.6 Examples of module spacing

2.7a Insert BoxLED Plus DS modules into the required number of a track pieces referring to step 2.6 for layout options 2.7b Insert one end of the module into the track and push down on the opposite end until it clicks into place 2.8 Loop any excess wire around the track in-between the modules and tie wrap it into place

2.9 Slide the Left and Right mounting brackets onto the corresponding ends of each of the a track segments 2.10 Slide the assembly into the desired mounting holes in the b track segments and push down on the left and right brackets so they click into place

3.0 ELECTRICAL INSTRUCTIONS 3.0 Use wire nuts or connectors to connect the white and red (+) input wire of the modules to the red (+) output wires of the 24V power supply. Connect the black and white (-) input wire of the modules to the blue (-) output wire of the 24V power supply (see Figure 11). 3.1 Cap off any unused connection wires when finished. 3.2 Make sure AC line is OFF before beginning power supply installation. Secure power supply to clean metal surface using screws (see Figure 12). Figure 11 Figure 12 3.3 OPTIONAL AC DISCONNECT SWITCH INSTALLATION: Connect disconnect switch in line with VAC line (black wire) (see Figure 13). VAC into Disconnect isconnect Switch Optional Disconnect Switch VAC out from Disconnect Switch Figure 13 Figure 14 3.4 Finish power supply AC connection by connecting black VAC line to black input cord of power supply, and white neutral to white input cord of power supply. Connect green ground wire from line to the same metal surface the power supply is mounted on (see Figure 14).

3.5 Power Supply Information: Table 1 Power Supply Information Item Number Ordering Description Power Supply Wattage Input Voltage (VAC) Input Current (A) Output Voltage (V) 51598 OT50W/24V/120V/LP 50W 120 0.47 24 51514 OT75W/24V/UNV 75W 120/277 0.76/0.33 24 51522 OT96W/24V/UNV 96W 120/277 0.97/0.39 24 Table 2 Max. Number of Modules per Power Supply BX-DS-PL (73502, 73737) BX12BA-W4F (71920) Item Number Ordering Abbreviation Max. Modules per Power Supply 51598 OT50W/24V/120V/LP 6 5 51514 OT75W/24V/UNV 10 7 51522 OT96W/24V/UNV 13 9 4.0 Troubleshooting Guide Problem Possible Cause Corrective Action Entire sign does not light No input power Check AC connection to power supply. Check power supply connection to modules. Entire sign/one or more LED runs do not light Part of an LED run does not light One module does not light No power to LED modules No power to that run Module has been damaged Check DC polarity- power supply red output wires must be connected to red striped module wires, power supply blue output wires must be connected to black striped module wires. Verify power supply output voltage is 24V. Check module to module connection for correct polarity. Replace the module. Observe correct polarity. Specifications subject to change without notice OSRAM, BoxLED, and OPTOTRONIC are registered trademarks of OSRAM GmbH SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc. SEE THE WORLD IN A NEW LIGHT is a trademark of OSRAM SYLVANIA Inc. 2016 OSRAM SYLVANIA Inc. 02/16