LSRFortessa Guide. Cell Evaluation and Therapy Core HO324

Similar documents
FACSLSRFortessa SORP QUICK REFERENCE GUIDE

UNC Flow Cytometry Core Facility LSR II Operation 2018

Log into the computer using your CU Denver username and password. Log into the DIVA software using your CU and Username and the password flow

Setup protocol for Firefly particles. On BD LSR II and LSRFortessa cytometers with single tube loader function

Canto II Operation Protocol

Flow Cytometry & FACS Core Facility

Unscrew and remove the cap from the waste tank

BD FACSDiva Software Quick Reference Guide for BD FACSCanto Systems with Loader Option

Setup protocol for Firefly particles. On BD FACSCanto cytometers with single tube loader function

CyAn ADP Guide. Starting Up

FACSAria Fusion SORP QUICK REFERENCE GUIDE

FACCalibur Users Guide

BD CellQuest Pro Acquisition Tutorial

USER GUIDE TO BECKMAN COULTER FC500

The Danish Stem Cell Center (DanStem) Danish Stem Cell Center Flow Cytometry Core Facility. LSR Fortessa Guide

BD CellQuest Pro Software Acquisition Tutorial

Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance:

FACSLyric TM General User instructions

STANDARD OPERATING PROCEDURE FOR THE LSR II

Standard Operating Procedure For: Independent End User Training and Maintaining Optimal Instrument Performance:

CELLQuest Acquisition Tutorial

Science is hard. Flow cytometry should be easy.

Customer ( you ) must review these notes prior to installing or operating the Attune NxT Software version ( Attune Software v1.1.0 ).

Gallios TM Quick Reference

BD Influx Standard Operation Protocol - Basic Operation

BD Multiwell AutoSampler Additional Features Tutorial

Release Notes Life Technologies Attune NxT Cytometric Software v 2.0.0

BD FACSMelody Cell Sorter Quick Reference Guide

LEGENDplex Data Analysis Software Version 8 User Guide

Release Notes Thermo Fisher Scientific Attune NxT Software v2.4

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer

Applied Biosystems Attune Cytometric Software version 1.2 Release Notes

For additional information, please consult the Read-Me and Help documentation or contact Electro-Voice or Dynacord technical support.

Release Notes Life Technologies Attune NxT Software v2.2

JMJ-Group Microbiology BMB SDU

Technical Note. Display of BD Accuri C6 Software- Generated FCS 3.0 Files Using FlowJo for PC and Mac v7.6. Introduction

BD CellQuest Pro Analysis Tutorial

Flowlogic. User Manual Version GraphLogic: Developed by scientists, for scientists. Graphing and Statistical Analysis.

NovoExpress Software Guide. Software Version 1.2.4

Release Notes Life Technologies Attune NxT Software v2.3

FACScan 4 and 5 Color Upgrade Rainbow Users Guide

FloMax Software for Cytometry. Operating Manual Instrument Control and Acquisition. FloMax Operating Manual Instrument Control and Acquisition

KIN 147 Lab Practical Mid-term: Tibial Acceleration Data Analysis Excel analyses work much better on PCs than on Macs (especially older Macs)

Navigate to Cognos Cognos Analytics supports all browsers with the exception of Microsoft Edge.

FlowJo Software Lecture Outline:

KIN 147 Lab 02: Acceleration Data Analysis

Attune NxT Acoustic Focusing Cytometer

The following instructions cover how to edit an existing report in IBM Cognos Analytics.

Appendix 1: DataStudio with ScienceWorkshop Sensors Tech Tips

KIN 147 Lab Practical Mid-term: Ground Reaction Force (GRF) Data Analysis

II.1 Running a Crystal Report from Infoview

Basic Tutorial. Data Analysis Software for Flow Cytometry Windows/Mac user documentation

2015 Optima Healthcare Solutions Page 2

SPA III Quick Reference Guide for Custom Panels

Flow Cytometry Analysis Software. Developed by scientists, for scientists. User Manual. Version Introduction:

KIN 147 Lab 06: Ground Reaction Force (GRF) Data Analysis Excel analyses work much better on PCs than on Macs (especially older Macs)

Contributing Lists in Activity Center

Overview. Experiment Specifications. This tutorial will enable you to

BD Lyoplate Human Screen Analysis Instructions For analysis using FCS Express or FlowJo and heatmap representation in Excel 2007

PerkinElmer Series 200 HPLC: Operating Procedure

How to set up an Amazon Work Profile for Windows 8

ADOBE DREAMWEAVER CS4 BASICS

FileLoader for SharePoint

AGENT123. Full Q&A and Tutorials Table of Contents. Website IDX Agent Gallery Step-by-Step Tutorials

Fairfield University Using Xythos for File Storage

CalPlan. Creating a Unit Plan Navigating CalPlan Workbook 1/25/18

TRAINING GUIDE. Web App End User Training

Cytomics FC 500 Quick Reference

BD High Throughput Sampler User s Guide

Navigate to Cognos Cognos Analytics supports all browsers with the exception of Microsoft Edge.

Lesson 16: Collaborating in Excel. Return to the Excel 2007 web page

Office 365. Exporting and Importing Safe and Blocked Senders List

How to Export a Report in Cognos Analytics

Flow Cytometry/FACS Bio-Rad S3e Cell Sorter

Spherotech, Inc Irma Lee Circle, Lake Forest, IL

Aqueous GPC Instructions - Detailed

Scheduling Book Set-Up & Check-In Preferences

Hands-On Lab. Developing BI Applications. Lab version: Last updated: 2/23/2011

Introduction to Cognos

DATA ARCHIVING SOFTWARE V.

What s New in Cognos. Cognos Analytics Participant s Guide

Downloading & Installing Audacity

Gallios Flow Cytometer

JANUARY 1, University of Wisconsin Business Intelligence QUICK START GUIDE

Document Management System User Guide

Preparing Chart Aggregations with Custom Report

Student User Guide: Navigation. Student User Guide: Navigation Toolbar

Jack s Coal Fired Pizza

Determination of Drag Coefficient

User Guide. Web Intelligence Rich Client. Business Objects 4.1

PST for Outlook Admin Guide

Using Excel to Troubleshoot EMIS Data

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software

Digital IDs (E-Signatures) in Adobe Acrobat

Microsoft Excel 2007 Beginning The information below is devoted to Microsoft Excel and the basics of the program.

SAS Job Monitor 2.2. About SAS Job Monitor. Overview. SAS Job Monitor for SAS Data Integration Studio

Pay Stub and Direct Deposit Self-Service

Sciex QTrap Operational Steps for Trained Personnel

Standard Operating Procedure for the Horiba FluroMax-4

Getting Started with DADiSP

Transcription:

LSRFortessa Guide Cell Evaluation and Therapy Core HO324

Before Use: Prime the instrument twice with no tube and arm to the side Ensure that sheath is full and waste is empty To Begin: Log into ilabs tracker with your MUSC email and your ilabs password Launch Diva from the desktop Diva user name: Last name (no passwords) Allow the cytometer to connect to the computer If Prompted choose use CST settings

Welcome to Diva! Choose a new experiment

You can rename your experiment by right clicking and selecting rename or by selecting the experiment and renaming it in the inspector.

Cytometer Settings: Select the appropriate flurophores for your experiment. You can select these from the drop down window in the inspector. The ones you do not need can be deleted. Multiple parameters can be deleted at once by clicking the dot outside while holding down the Ctl key.

At a minimum, select the Area (A), Height (H) and Width (W) parameters for FSC in order to eliminate doublets from your analysis. FSC should be collected using linear scale. SSC can be collected in either linear or log scale, depending on the needs of the experiment or preference of the lab. All fluorescence parameters should be collected in log scale unless DNA cell cycle analysis is to be performed. Area should be selected for fluorescence parameters on LSR II instruments. Example of the same data collected in SSC Linear and SSC Log:

Automatic Compensation: Create compensation controls by selecting the Experiment dropdown> Compensation Setup> Create Compensation Controls Select the OK button. You will see a specimen appear in the Browser window labeled Compensation Controls.

Expand the compensation control specimen by clicking the + symbol. Click on the Tube pointer next to the unstained control, it should turn green. The tube pointer must be green on the tube you wish to be acquiring/recording. Simply highlighting the tube will not suffice. Green point active Yellow point acquiring Orange point recording

Place your unstained cells on the SIP tube and select Acquire in the Acquisition Dashboard window. DiVa sets the events to record at 5000. You may elect to increase this number by selecting the dropdown or typing the number of events you want to record in the box. Highlight your adjusted P1 gate, right click, and select Apply to All Compensation Controls.

In the Acquisition Dashboard select Next Tube or select the Tube Pointer next to the first single color control sample Compensate calculation values by selecting Experiment dropdown > compensation setup > calculate compensation.

If compensation is calculated successfully you will be asked if you want to apply or link and save. You may save this if you want to access this compensation again. Collecting Experimental Samples: Add a new specimen by clicking the syringe icon or by navigating to the Experiment dropdown> New specimen and select Blank Panel. Note: If the tube pointer is still pointed at your last single color control, the plots you create will show the events from the single color control Create gates using the gate buttons on the Worksheet toolbar Change the parameters on the plots by right clicking the label on the plot and selecting the desired parameter.

Some parameters may not be available until you move the Tube Pointer to the first experimental tube. To make a plot showing only gated events either right click the plot and go to show populations Or double click parent gate and select drill down

The Acquisition Dashboard: Events to record: How many stopping events are going to be recorded? Events to display: The number of events that appear in the worksheet window Sample acquisition: Acquire your first experimental tube. Adjust the flow rate using Low, Med, and High on the cytometer. When the event rate stabilizes (keep below 10,000 evt/s), click Record in the Acquisition Dashboard. Recording will stop automatically when the Events To Record have been collected (or the Stopping Time has passed) but your sample will continue to be drawn as long as it remains on the SIP. If the Events to Record has not been achieved and there is no sample left to run, promptly remove your tube and move on. Never leave an empty tube on the SIP with the arm engaged. This will force bubbles into the flow cell. Select Next Tube in the Acquisition Dashboard to move to the next sample or use the Tube Pointer to select the tube and record as above. Once all of your tubes have been collected, export your FCS files. Highlight the experiment name in browser, right click, select Export > FCS files.

Select the type of FCS file required (generally this should be 3.0) and click the OK button. Export the FCS files to the D:/BDExport/FCS folder or to your attached portable drive. When the Export FCS File(s) progress bar reaches 100%, copy the FCS files to your own personal drive. We encourage you to delete your own data from our computers, however we will universally delete the data after 2 weeks.

Clean and Prepare for the next user: Put a tube with ~3ml (~half tube) BLEACH (squeeze bottle) on the SIP and run in HIGH for 5min. This step is crucial to decontaminate the instrument. Put a tube with ~3ml water on the SIP and run on high for approximately 3min. Leave ~1mL of water on the SIP and hit STANDBY. Check and fill sheath, empty waste and add approximately 300ml bleach.