INSTALLATION MANUAL for the Application ihc-mirf

Similar documents
Installation Manual ihc-mirf Installation Manual for the Application ihc-mirf

Installation manual ihc-miirf

Installation manual ihc-mairf

elan-rf-003 Manual / rev.5 Page 1 of 13

The Smart Prime 6 Frequently Asked Questions. The Smart Prime 6 handset

Document Number: /4/2012

Smart Home Controller 2.3 Release Notes Contents

Home Monitoring and Control service provided by Verizon Online LLC

Installation Manual ihc-ma Installation Manual for the application ihc-ma

1. CONTROL OF THE LIVING ENVIRONMENT WITH ENTIALIVING SYSTEM 4 2. LIGHTING CONTROL WITH ENTIALIVING SYSTEM 5

USER HELP GUIDE. NOTE: We suggest that the user s device be upgraded to the most current version.

GAME OF LIGHTS KIT FOR CONTROLLING LIGHTS VIA SMARTPHONE PERFECT LIGHT ATMOSPHERE FOR EVERY OCCASION AND MOOD. User s manual 2.

Page 2 of 7 How do you recognize a successful connection? After successful connection the app will show the Main Dashboard automatically. Main Navigat

User Guide for Feit Electric App. Set up instructions for Alexa & Google Home.

ipad and iphone Basics

App Instructions. Quick Start Guide. works with the Google Assistant

Smart Home Controller 2.2 Release Notes

GAMMA instabus Application Program Description. November CO Touch-Panel

USER S MANUAL. DAS-G01 The Power of Tomorrow

FOCIS Flex Inspection

ALIBI Witness 2.0 v3 Smartphone App for Apple ios Mobile Devices User Guide

CONTROL4 INTEGRATION WITH THE SHADE STORE MOTORS CONTROL4 INTEGRATION OVERVIEW:

Manual Version: V1.01. Video Management Server Client Software User Manual

Guarding Expert Mobile Client Software

PRODUCT MANUAL LEDWizard Dynamic White LED Controller

Quantum 3.2 Software. User Manual

Smart Home Controller 2.2

Use of the application program. Table of Contents. GAMMA instabus Application program description. April B0 CO Room Control Unit

Full manual Nedis SmartLife

INSTALLATION & OPERATING INSTRUCTIONS when Touch-5 Wi-Fi Module is Installed in PCR-4 Driver/Receiver

Connection Guide (for D SLR Cameras) En

GAMMA instabus Application Program Description. July CO Colour Touch-Panel

Getting Started. Activation Process. G450 Overview

Do not place or mount Ocli 1 in an area where it will be exposed to water. Ocli 1 is designed for indoor use.

SAVANT PRO 8 APP AT A GLANCE

Total Connect 2.0 Online Help

XTS36 Touch Screen X10 Lighting Control System Operating Manual

Virtual Keypad App Help Last update: 2017/02/02

WaveLinx. This document is intended for Lighting Control Systems and IT professionals. User Manual

NVMS User Manual. Version 2.1.0

PIVOT CMS CLIENT SOFTWARE USER MANUAL

INTRODUCTION... 2 GETTING STARTED...

V0STAT51P-2 Programmable Wired Controller

COMPUTHERM S200 Wi-Fi socket

Connection Guide (for KeyMission 80)

Connection Guide (for COOLPIX)

Tablet PC User Manual

Discover the Start screen.

CME E-quotes Wireless Application for Android Welcome

DMS Local. User Manual. For Projector Management V 1.01

College of Pharmacy Windows 10

Overview - Danfoss Link and Connect software versions

USER MANUAL. Mac Version

Enter your Appserv username and password to sign in to the Website

Wireless RAK system setup guide

Smarter More Helpful Home Light Bulbs That Work with Alexa or Google Home

TOUCHDIAL Mobile App OPERATION GUIDE TABLE OF CONTENTS TOUCHDIAL MOBILE APP OPERATION GUIDE 1 OF 6 IG

IdeaTab A1000L-F. User Guide V1.0. Please read the Important safety and handling information in the supplied manuals before use.

Marian University Rooms 126, 130, 210, 218, 224, 228 (A)

Brivis Touch. Owner s Manual

Ctdigi.com. Instruction manual. Production by S & W Technology Labs

battery icon in the bottom right corner of the display screen.

Microsoft IT Showcase. microsoft.com/itshowcase

Shortcut To Turn Off Laptop Display Windows 7

PowerShield 8. Configuration Manual

Getting Started. Gateway Activation Process. Gateway Descriptions

iridium for HDL-BUS Pro

GV-Eye Mobile App. Contents

Video Management Software

SIMPLE CONTROL. User Guide

Deseo KNX Manual. Deseo KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 65 v basalte

SERIAL PORT TOOL. N-Button Lite Quick Start Guide

Veris Sensors App. Quick Start Guide Pressure Monitoring. For Use with Differential Pressure / Air Velocity Transducers. Introduction.

aaxa TECHNOLOGIES User Guide

Table of Contents. Chapter 1 Introduction Chapter 2 Quick Install... 7

QUICK START GUIDE. U.S. Cellular Customer Care:

Colour Touch Panel 3.5

INNOV.NET PTY LTD. User guide

ipads for Beginners For All HCPS Individual ipad Users

Exploring Windows 8. Starting Windows 8 for the First Time. About Windows 8 User Interface and Features. Get Started. Unlock Your Computer and Sign In

Video recorders DX Series

Application description. KNX push-button 1gang. KNX push-button 2gang. KNX push-button 3gang. KNX push-button 4gang. Page 1/51

ipcam-wo Wireless Outdoor

AI Suite 3 User Manual Quick Menu AI Suite 3 AI Suite 3 Main menu AI Suite 3 Utilities System requirements

User Guide Introduction

Catalogue. Assembling... 1 Unpack Charge the Battery Install the Memory Card Product Basics Buttons and Connections...

DART SVP. Software Manual For Web Based User Interface And For Apple ipod touch User Interface. Software Version 3.0.x ipod Application Version 1.

Wi-Fi Pan & Tilt Camera AlwaysSafe App Manual. ios and Android. English

Operation Guide CT32 ENGLISH

Phone Overview. Important buttons on your Jitterbug Smart

Motion Sensor 2 with temperature sensor

Your familiar Windows, only better.

Battery Charging The tablet has a built-in rechargeable Li-polymer battery.

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen.

ELAN INTEGRATION WITH THE SHADE STORE MOTORS ELAN INTEGRATION OVERVIEW:

LIGHTIFY App - User-Guide

Tel: sp.com Support: 8:30 AM to 8:00 PM Canadian statu tory holidays obser ved.

Model: Available in : Sapphire Black and Glacier White

Click Install View Touch. Installation starts. Click Next. Click Finish.

Getting to know your ipad exploring the settings, App store, Mail

Transcription:

INSTALLATION MANUAL for the Application ihc-mirf

Contents Introduction 3 Installing the application on a mobile phone 3 Settings 4 Control 12

Introduction The applications ihc-mirf (for mobile phones with IOS) are designed for comfortable control of the RF Control electrical installation using your mobile telephone. This is an RF Control system accessory, and as a part of the inels Smart Home Solution, its elegance blends in with any modern home. The menu is divided into clearly structured sections in which the icons indicate individual functions. Here you will also find faster access to your favorite functions, and you will maintain a constant clear view of what s happening in and around your home. Thanks to ihc-mirf (the application ), you can perfectly control the function of your wireless RF Control electrical installation. You thus keep complete control over your home lights, appliance switching and heating. The application only works with the device elan-rf-003 or elan-rf-wi-003. This unit must be used in your wireless installation. It is designed for devices with IOS 8.0 and higher. It is optimized for devices with a display resolution of 800x480 The application language follows the language set in the IOS Implemented communication with Axis video cameras, thanks to which you can monitor what s going on around your home. It also enables control for multiple users at once (by entering multiple IP addresses). It enable creation of week-long programming or communicating with temperature units. Setting options: max. number of actuator per application- 40 max. number of time schedules (for dimming and switching)- 16 max. number of time schedules, heating- 16 max. number of actuators in one schedule - 8 max. number of intervals in one schedule - 8 max. number of heating circuits - 16 max. number of heating and cooling devices in one heating circuit 10 max. number of central sources - 10 Downloading: Download the current version (named ihc-mirf) at the Apps store. https://itunes.apple.com/cz/app/inels-home-control-rf-for/id704493937?mt=8 Installing the application on a mobile phone - Connect to the Internet using your mobile telephone. - Activate the service app store. - In the search bar, enter the password inels and press Search. - Select the application inels Home Control RF Mobile for iphone from the list and open the dialog box with information on this application. - Click on Install. - After the application is successfully installed in the phone, instead of the button Install, the button Open appears. 3 / 14

Settings The application ihc-marf is designed for controlling the installation so that once started, it immediately offers control over the electrical installation. To achieve this with as few presses as possible, you must first set up and configure the application. Initial display upon running the application*: Basic upper bar of the telephone Tab Scenes The home application desktop. After configuring, the basic tiles of the control system are displayed. Tab Cameras Tab Favorites By pressing Settings, the basic application settings menu displays. Setting the IP address of the communication interface, by means of which the telephone communicates with the wireless units elan-rf Selection for setting the tab Heating Selection for setting the tab Scenes Selection for setting the tab Others Selection for the basic configuration of the application and device, elan-rf device settings. Configuration of the project of the installation, assigning addresses, pairing actuators, assigning icons, etc. Selection for setting the tab Favorites Selection for setting the tab Cameras Help button Tab Settings * If elan is connected with the application, the top bar is blue. A grey bar shows loss of connection between elan and application. Tab - elan Settings Manually adding elan-rf: If you know the IP address elan-rf to which you want to connect, you can press the button Add. Enter its name (any name) and IP address. Automatic search: Press the icon search. Discovered elan-rf units appear that are located in your network to which you are currently connected by phone (home network). Icon Search Searched elan-rf By pressing the required elan-rf, a window opens up for you to name it. After entering the name, confirm by pressing OK (if manually entering, the elan-rf is named when added). In this device list, you can have several elan-rf devices and IP addresses configured. Here you can introduce one elan-rf even with two IP addresses (with an internal IP address for the home network and a public IP address for remote communication). Button for manually adding elan-rf By pressing Refresh, you can restart a search for elan-rf in your network For the application to run properly, you must highlight it in the list of the elan-rf with which the application is to primarily communicate 10s after designating the application starts automatically downloading all the settings from elan-rf (if elan is already coupled to RF). By pressing Back, you return to the settings menu. If you have already set up the elan-rf, click Back to go back to the desktop with set-up units. If you are setting up the elan-rf for the first time, continue setting it up according to the manual. Any name will suffice Selection of the required elan-rf 4 / 14

Tab - Configuration By pressing the tab Configuration, you will arrive at the basic settings menu. Rooms In the field Name of room, you can enter any name (even with diacritical marks) In the field Select room type, choose the room icon. If you only create one room, the device is displayed directly on the desktop. Window for name of room Window for selecting room icon Button for adding Rooms Button for saving the selected room Units To add a unit that you want to control through the application, you must fill in the fields: 1. Name of unit - any name 2. Enter the unit address the address is a six-digit code listed on the unit box. 3. Type of unit - select type of unit. 4. Temperature offset - set the offset (if the temperature from the actuator sensor differs from the true ambient temperature) - only for Thermal elements. 5. Select type of icon to be displayed. Entering any name of unit Entering added unit address Window for selecting unit type Removing a unit by a long press on the given unit. Modification / renaming by a short press on the given unit, you will open the settings options. Modify the offset Window for selecting icon type Button for saving the added device Added units Add units After adding rooms and all required units, it is a good idea for a clearer picture to assign units to individual rooms, in which they are found (not a condition). Select the room in the menu Add units. By pressing, you assign the unit to the selected room. By pressing Next, you can select the next option and continue assigning. Upon a change in assigned units, continue the same way by pressing, you change the device selection status. Selection of the room for adding units Confirmation button upon selecting the unit Next button for continuing and consequent saving 5 / 14

Plan In the plan, you can set the desired function element depending on day and time. In the Name field, type the name of schedule. In the Elements 1-8 mark the elements that you want to associate with the plan. One plan can be assigned to the elements of one type. Confirm by pressing OK. Displays menu functions for different types of elements: - Switching: the possibility of setting ON / OFF - Switch for blinds: blinds up / down. - Dimming: 3 adjustable levels of brightness and illumination up to 100%. Upon pressing the Next button a graph appears, where you can set the schedule function. When creating a plan, you will see a graph displayed for Monday. Click (+) New you can set the time intervals (in hours and minutes) and choose the desired function. You can create up to eight time periods for one day, which you can change at any time during use. You can set the timetable by using the Copy (+), this allows you to copy to other days. By pressing All-copy you can schedule all the days of the week. Pressing the Save button saves the settings. Modify / delete the time interval. In the required time plan, press Next. By a long press right on the time interval, you open a table for modifying the time or deleting the interval. Save the time interval modification by pressing Save and then confirming by pressing Save settings. Pressing expands all the elements associated with the schedule Vertical time interval slider Schedule for the different levels of brightness with a dimmer feature Fast modification of time interval. Shortly press the time interval, and it will set the sliders. You can modify the interval as needed by simply moving the sliders to the sides. 6 / 14

Tab - Heating You can control heating in the application from the central source to control e.g. of a RFATV-1 thermovalve mounted on a heater valve. Selection for setting the tab Heating Direct control of thermo-valve RFATV-1 You can add thermo-valve to the room as a separate unit, without having to be assigned to the heating area. Thermo-valve has a built in temperature sensor. App lets you operate your heating (where thermos-valve is installed). Name the thermo-valve Thermo-valve address Window for selecting unit type Modify the offset Confirmation button upon selecting the unit Window for selecting icon type Control using a time schedule The first step is selecting the central heating source (if it is necessary to control it) e.g. switching on an electric boiler. The next step is placing units for temperature control (heating units, switches, thermovalves) in the required space (room). You can have units placed in the required room for temperature control even without controlling the central heating. Naming the time plan Assigning modes: Selectable hysteresis 1. Time plan for heating, which you want to use. In the field Name, enter the name of the heating program In the field Hysteresis, select the required hysteresis in a range of 0.5-5 C. Setting heat modes - by pressing on the window beside the time modes, you can modify temperatures for individual rooms. In the lower right corner, press Next. Adjustable temperatures for individual modes Once the menu drops down, select the temperature by means of pickers 7 / 14

The graph appears, where you set the time plan of heating modes. By default, the heating mode Minimum is set throughout the week throughout a 24-hour time axis. When creating a time plan, you will see displayed the heating mode for Monday. By pressing (+) New, you can set the time intervals (in hours and minutes) and select a heating mode for them. You can create up to 8 time intervals for a single day, which can be changed at any time during use. By pressing (+) Copy to, you can copy the set time schedule to other days. By pressing All, you will copy over the time schedule to all days of the week. By pressing the button Save, you can save the settings. Setting the start of the time interval Setting the end of the time interval Setting the end of the time interval Heating modes with set temperature Name Button for saving Time interval Button for adding a time interval Button for copying the daily plan Set day Slide for setting further days Modify / delete the time interval. In the required time plan, press Next. By a long press right on the time interval, you open a table for modifying the time and mode or deleting the interval. Save the time interval modification by pressing Save and then confirming by pressing Save settings. Option of changing the interval time Option of changing the heat mode Button for deleting time interval Button for storing the modified time interval Fast modification of time interval. Shortly press the time interval, and it will set the sliders. You can modify the interval as needed by simply moving the sliders to the sides. Vertical time interval slider Modified time interval 8 / 14

2. Heating circuits (heating rooms) to which you can assign time plans. Press Heating circuit, and by pressing Add at the bottom right, you will create a new heating circuit. Name enter the name of the heating circuit (e.g.: Room 1) Select the temperature sensor - select the required unit with temperature sensor (e.g. RFATV-1). Some units have two temperature sensors - internal and external - selected the required one*. Select the temperature plan from the set menu. Select holiday plan - a set menu. The schedule is be activated by one press and is used for temporary discontinuation of the extended schedule (not a condition). Select heating - here select the units found in the given area and those that you want to control heating of a room. If you have a controlled central heating source, you can assign it to the selected heating For easier control, we recommend creating a separate room for heating circuits, into which you will assign all heating circuits. Select the name of the heating circuit Select the temperature sensor Select the temperature plan Select the temperature plan Select the heating that the room contains Press to display the heating selection Selection of central heating source * RFSTI-11/G: a choice between internal and external sensors and mixedmode (mixed mode - measured space temperature sensor internal and external sensor monitors the critical temperature of the floor, when exceeding of the critical temperature occurs the floor heating is turned off regardless of the temperature measured by the internal sensor). 3. Central source Press Central source, and by pressing Add at the bottom right, you will create a new central source. Name enter the name of the central heating source. Unit select the unit by which you switch on the central source. Heating circuit indicate the heating circuits that you want linked to the central source. Save by pressing Save. Name of central heating source Select the unit for the central heating source Assigning a central heating source to the heating circuit Button for saving the central heating source Tab - Favorites By pressing Add, a list opens of configured devices, which you will designate with. After pressing Save, it is assigned to the list in the Favorites tab. THERMO-VALVE Field for selecting the device in the Favorites tab List of all devices configured in elan-rf Button for saving the Favorites tab configuration 9 / 14

Tab - Scenes The list of scenes is used to activate the user s predefined scenes, such as all off, all on, all blinds up, all on - all blinds down, etc. After pressing the Scenes tab, press Add. Name enter the name of the light scene. By designating you select the units you want to assign to the light scene. When finished selecting, press Next. Choose the functions of the single units you wish to perform when launching the scenes. Field for selecting from used units for configuration in the Scenes tab Name the scene Scroll bar of selected units in the created scene. Primarily, units are selected at the middle position of the scroll bar - under the scene name The Next button for selecting units switches to the display for setting the functions of selected units At the dimmer settings function, set the required brightness that the unit sets when the scene is activated Tab - Cameras If you wish to have video cameras always at hand, you can add them to the quick display - Tiles. In the ihc application, you can also view the current image (stream) from home security Axis IP video cameras, custom. By pressing Save, you will open the menu with settings to Axis IP video cameras. Note: When using other than the recommended IP cameras custom, format of stream requires mjpg. Please insert this format in the column Enter an address of camera. To access your stream please use e.g. web interface or check in the camera manual. If the stream is not in a format MJPG, the App connection attempt will fail. Example: Address format: ip address:port/mjpg/video.mjpg Address format example: 10.10.5.142:80/mjpg/video.mjpg Field for displaying the IP address of the installed video camera Field Type of video camera - selection field with menu of video camera manufactures inels cam, Axis and custom. ROOM Field for arbitrary naming of the IP video camera e.g. Living room Field for entering the log-in name to the added IP video camera Field for entering the log-in password to the added IP video camera After filling in items on the display, press Save. The application saves the settings and automatically adds the video camera to the list of devices in the Cameras tab. Removing a video camera from the list by a long press on the given item in the list. The application allows full screen video camera display; press and hold the relevant video camera view to open the PTZ panel to control it (if the PTZ camera supports it). CAMERA Cameras tab with defined video cameras and camera view in the tile position on the desktop Open tile of the defined IP video camera in the ihc application. The video image (stream) from the video camera now automatically reverses based on the telephone s approved services PTZ control elements 10 / 14

Tab - Other In the selection field Display panel Favorite items after startup, set the list of favorite items on the start page after starting the application. In the selection field Receive notifications on new firmware - set automatic checking of availability of the newest version of firmware for your elan-rf, and you will receive notifications to your mobile phone. After receiving notification, the application will ask you to update in the form of a red circle with an exclamation point. Pressing the button with the update offer will lead you to the menu Other. By pressing Update elan, the firmware in your elan-rf will be automatically updated. After using the function Receive notifications on new firmware, you must have an Internet connection via Wi-Fi network or mobile data. Confirmation button for displaying the panel Favorites after startup Confirmation button for obtaining notification on availability of a new firmware version of elan-rf Button after downloading the latest firmware version into a mobile telephone Enable checking of the time in elan - function monitors elan time synchronization and applications (eg. If elan is not connected to the Internet). If the difference is more than 5 minutes, the application displays a warning. Item Download newest firmware version is used to download the latest firmware version into your mobile telephone. In case you already have the current firmware installed in your mobile phone, it offers you the option to delete it. To use the function Receive notifications on new firmware, you must have an Internet connection via Wi-Fi network or mobile data. After connecting your telephone to the elan-rf device, you can press Update elan (in the menu Other), update firmware in elan-rf. Thanks to this, you have the option of updating the firmware in the device elan-rf even in places where an Internet connection is not available. Offer for update Click to start update Information on the progress of update Download settings elan - function allows you to download the current settings for the connected elan-rf directly to your phone. * Backup settings are stored in memory on your telephone. Record elan settings- displays the saved settings for elan that you can upload from your phone to the currently connected elan. License displays information Upgrade feature - when updating firmware from elan version 2.7.012 or higher it is required to press the button (the new features are already assigned to the set features). Clear saved settings The application version is uploaded to your phone. elan upload status * After configuration is recommended to save your settings for the elan through an application or Web interface 11 / 14

Control The main display in the ihc application is formed of so-called Tiles. This is a general overview of rooms in the intelligent electrical installation inels Home Control. Based on the previous steps for settings, the initial tiles of the application will appear on the screen: based on units in rooms (e.g. rooms as in living room ) based on groups (e.g. Lights or All ). If you want to control individual units, press the required room to which you have assigned the given unit. If the configuration is set up that there are more than 6 tiles on the default display, switch between them by dragging your finger up/down along the display, i.e. scrolling. After displaying the list of units in a certain room, you can control individual devices. Pressing inels displays the room set Basic overview of configured tiles in the application menu. Tile (room) Button for configuring the system and settings from the application Output Status indicators are automatically updated when any status/ mode/temperature change occurs. Warning: if you control the blinds using any other method eg. A key-chain, wall or other controller., The application displays the current status of the output. For correct display, perform a manual update of the status output. The manual update of Output Status indicators can be activated (in the case of the sleep mode) by dragging your finger across the screen (ie. scrolling). Then the Output indicators will be updated. Auto Symbol feature, works automatically according to schedule. The timing symbol shows the current timing (for dimmers - start / stop, with the switches - On- / Off -delay, with the switches for blinds - blinds move). Controlling dimmers Arrows for switching between individual rooms Symbol, icon assigned to the given unit, device You can scroll up and down through the tiles by dragging on the screen By a short press of the unit tile, you can change the unit status ON/OFF. In case of blinds UP/ DOWN Status bar of monitored rooms Auto Symbol Time Symbol Unit output status indicator, or device on - brightness at 70%. To bring up the brightness setting, the slider must be held on the unit tile Unit output status indicator, or device on, off If you hold your fi nger down on the device, you will see displayed e.g. for a dimmed light, a bar graph for setting the dimmed light brightness. Two buttons are displayed underneath it - increase and decrease, enabling smooth dimming and brightening of the light. If the dimmer is assigned to the schedule the possibility of switching on / off the Auto function will also be displayed. For the buttons increase and decrease, by pressing the arrows, a menu opens with options for setting the time of the increase / decrease functions. While setting the time the automatic time setting must be off, after saving the settings turn on the automatic setting for correct function of the schedule. By pressing a dimmer with RGB control option, you will see the menu displayed for setting color, brightness and the brightening mode. Settings of RGB light color Bargraph for setting the brightness Press to initiate gradual brightening Button for setting time Button for setting the time of the given function After setting the time, press to confirm Press to initiate gradual dimming Set time minutes : seconds Setting the light RGB brightness Switching off/on the RGB light Circus mode - automatic color change Currently selected color 12 / 14

Controlling switches For switches, you can run the function Delayed on / Delayed off and if the switch is assigned to a Schedule it will also show the possibility of switching on / off the Automatic function The delayed on / off time settings are set by pressing arrows by the buttons. While setting the time the automatic time setting must be off, after saving the settings turn on the automatic setting for correct function of the schedule. For delayed on/off, you can extend the time for up to one hour For switches for controlling blinds, the movement time of the blinds is set in the same manner as for previous ones. Setting the time applies to both directions. If the switch is assigned to a Schedule it will also show the possibility of switching on / off the Automatic function. While setting the time the automatic time setting must be off, after saving the settings turn on the automatic setting for correct function of the schedule. Button for lowering blinds Button for raising blinds Stopping the blinds Confirm the time Blue light - switched on Greyed out - off After setting the time, press to confirm Setting the movement time for blinds Thermo-valve control If you press and hold (long press) the icon of assigned thermovalve to room, the settings will be displayed: Manual temperature control 0-32 C The set / recorded temperature Display status - battery, open thermo-valve, the window status Adjusting the open window sensitivity Open window off time With any manipulation of batteries RFATV-1 (eg. Replacement) always recalibrate the thermal valve *. Display the current temperature Set temperature Buttons for quick temperature correction Manual temperature adjustment Display the battery s status Display the status of open thermo-valve Adjust the open window sensitivity Display the open window function Time setting of the open window Controlling the temperature control Heating circuits can be controlled right from the rooms in which they were assigned. For heating circuits in the room, the following is displayed: 1. Current heating mode to the given heating circuit. 2. Current temperature of sensor at the unit assigned to the heating circuit. 3. Heating circuit status backlit icon circuit is active, heating. Heating circuit status By a long press of the heating circuit, you will open the settings Indication of dead battery at the unit Current temperature of temperature circuit Display of the current heating circuit mode Indication of the unit already assigned in the heating area *Calibrating the RFATV-1: 1. open the battery cover 2. remove the batteries 3. after 30s, insert new batteries (observe the polarity) 4. close the battery cover 5. using a key, press the blue button. The thermovalve itself will find the extreme position open and closed on its own. During calibration, do not touch the thermovalve. A flashing green LED diode on the thermovalve indicates the end of calibration. 13 / 14

Heating circuit functions The heating circuit monitors the temperature by means of a selected sensor in the room. Once the temperature drops below the set level +/- of the hysteresis, the units in the room determined for heating begin to heat, (the thermovalve opens on the heater valve, the relay at the heater switches on, etc.) Change of heating mode in the circuit by a long press, you will open the required circuit, and based on the current requirement, you can: - change the heating mode - manually adjust the temperature 0.5-5 C - switch on/off the entire circuit (regardless of its time plan) - set the function - sensitivity to an open window (displayed only when the temperature circuit is assigned to a thermo head) - inform on battery status - inform on current and set temperature After manual adjustment of the heating mode, the heating circuit in the following set time interval returns, and will continue to work according to the set time plan You can manually adjust the temperature at any time by +/- 5 C, the corrected temperature is only for the current time interval. By pressing, you switch on/off the entire heating circuit regardless of its time plan. By pressing the button for setting the function window sensitivity, you can set the sensitivity and time of switching off the heating while the window is open. Here you will find information on the current status of the function. If the heating circuit contains units that are battery powered and the application ascertains that one of the units has a weak or dead battery, the left part of the screen displays the battery icon. By pressing the battery icon, a list is displayed of units needing a change of batteries. Another method of displaying a dead battery is indicated directly on the main screen at specific units, (rooms). The icon is only informative. In the correction wheel, the Set and Current temperatures are displayed. Set temperature - set in the heating mode +/- temperature correction adjusted by user. Current temperature measured by temperature sensor of one of the connected units. If an icon appears at one of the units in the form of a lock, this means that the unit is already assigned into some heating circuit. The unit cannot be controlled where, by an accidental press, you did not switch on heating that you have set in a different preselected time plan. Heating circuit after power supply outage: During the schedule - returns to the set timetable When manually set - returns to the set timetable If it is manually turned off - remains off. 1. Buttons for quick temperature correction 1 7 8 2. Set temperature correction 3. Battery status indicator 4. Automatic control of the heating circuit according to the selected heating plan 5. Holiday mode 6. ON/OFF 7. Manual temperature adjustment 8. Set temperature 9. Current temperature of heating circuit 10. Button for setting open window function 11. Temporary manual settings (function only applies until the next pre-set schedule changes 12. Manually setting (it does not change if you do not switch to another mode) 13. Option of changing the heat mode 2 3 9 10 4 5 11 12 6 13 14 / 14