Measuring baseline whole-brain perfusion on GE 3.0T using arterial spin labeling (ASL) MRI

Similar documents
Measuring baseline whole-brain perfusion on GE 3.0T using arterial spin labeling (ASL) MRI

ACQUIRING AND PROCESSING SUSCEPTIBILITY WEIGHTED IMAGING (SWI) DATA ON GE 3.0T

MB-EPI PCASL. Release Notes for Version February 2015

Existing Packages. Overview. Siemens. Michael A. Chappell

ASAP_2.0 (Automatic Software for ASL Processing) USER S MANUAL

A Virtual MR Scanner for Education

Transforming Datasets to Talairach-Tournoux Coordinates

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

Functional MRI data preprocessing. Cyril Pernet, PhD

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Table of Contents. IntroLab < SPMLabs < Dynevor TWiki

Rat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy

This exercise uses one anatomical data set (ANAT1) and two functional data sets (FUNC1 and FUNC2).

Correction of Partial Volume Effects in Arterial Spin Labeling MRI

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

GLIRT: Groupwise and Longitudinal Image Registration Toolbox

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

0.1. Setting up the system path to allow use of BIAC XML headers (BXH). Depending on the computer(s), you may only have to do this once.

Supplementary methods

GLM for fmri data analysis Lab Exercise 1

Image Acquisition Systems

Instructions for template creation and T1 normalization using SPM8 "new segmentation" and "Dartel" (September 27th 2010)

SIVIC Scripting Tutorial

SIVIC GUI Overview. SIVIC GUI Layout Overview

Neuroimaging Group Pipeline Quick Start Manual

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

MARS: Multiple Atlases Robust Segmentation

E. Mark Haacke, PhD. The MRI Institute for Biomedical Research Detroit, Michigan Wayne State University Detroit, Michigan 48201

SIVIC GUI Tutorial. HMTRC Workshop - March 23-24, 2017

FMRI Pre-Processing and Model- Based Statistics

BME I5000: Biomedical Imaging

The alignment process uses two alignment methods: (1) the mrvista function, rxalign, for a rough alignment, and then (2) KNK's alignment for

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Improved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm

Playing with data from lab

Empirical analyses of null-hypothesis perfusion FMRI data at 1.5 and 4 T

MRI Physics II: Gradients, Imaging

Functional MRI. Jerry Allison, Ph. D. Medical College of Georgia

Advanced MRI Techniques (and Applications)

The University of Chicago. Center for EPR Imaging in Vivo Physiology. Image Registration. Boris Epel

n o r d i c B r a i n E x Tutorial DSC Module

Structural MRI of Amygdala Tutorial: Observation, Segmentation, Quantification

CTA HEAD Perfusion AqONE without and with IV Contrast

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Pre-processing of ASL data T CT

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis

Bayesian Inference of Hemodynamic Changes in Functional Arterial Spin Labeling Data

MRI. When to use What sequences. Outline 2012/09/19. Sequence: Definition. Basic Principles: Step 2. Basic Principles: Step 1. Govind Chavhan, MD

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

ThE ultimate, INTuITIVE Mr INTErFAcE

This Time. fmri Data analysis

New Technology Allows Multiple Image Contrasts in a Single Scan

COBRE Scan Information

MRI Segmentation MIDAS, 2007, 2010

Page 1 of 9. Protocol: adult_other_adni3basichumanprotocol25x_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

Single Subject Demo Data Instructions 1) click "New" and answer "No" to the "spatially preprocess" question.

Release Notes Version 5.6

Ch. 4 Physical Principles of CT

Real-Time FMRI Tools & Automation in AFNI & SUMA

SIEMENS MAGNETOM TrioTim syngo MR B17

AFNI Preprocessing: Outline, Recommendations, and New(ish) Stuff. Robert W Cox SSCC / NIMH & NINDS / NIH / DHHS / USA / EARTH

MEDICAL IMAGE ANALYSIS

Politecnico di Torino. Porto Institutional Repository

SPM Course! Single Subject Analysis

GNU-AVR Building the GNU AVR Toolchain for Mac OS X and Linux

SIEMENS MAGNETOM Avanto syngo MR B15

Journal of Articles in Support of The Null Hypothesis

Artifact detection and repair in fmri

MR Advance Techniques. Vascular Imaging. Class III

GE Dynamic 13 C Acquisition

CS/NEUR125 Brains, Minds, and Machines. Due: Wednesday, April 5

Corso di laurea in Fisica A.A Fisica Medica 4 TC

DIFFUSION TENSOR IMAGING ANALYSIS. Using Analyze

SNMP Manager User s Manual

Statistical Analysis of Neuroimaging Data. Phebe Kemmer BIOS 516 Sept 24, 2015

SIVIC Scripting Tutorial

ANALYSIS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING DATA USING SPM99: VOXEL-BASED MORPHOMETRY DONNA ROSE ADDIS

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Carestream Vita user quick guide. Software version 3.2 From April 2012

SIEMENS MAGNETOM Avanto syngo MR B15

Role of Parallel Imaging in High Field Functional MRI

MRI image formation 8/3/2016. Disclosure. Outlines. Chen Lin, PhD DABR 3. Indiana University School of Medicine and Indiana University Health

Annexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

Automatic segmentation of the cortical grey and white matter in MRI using a Region Growing approach based on anatomical knowledge

Constrained Reconstruction of Sparse Cardiac MR DTI Data

Artifact Detection and Repair: Overview and Sample Outputs

A Spatio-temporal Denoising Approach based on Total Variation Regularization for Arterial Spin Labeling

Overview of fmri Analysis Software. McConnell BIC Open Methods Meetup January 13th 2013

I.e. Sex differences in child appetitive traits and Eating in the Absence of Hunger:

Analysis of fmri data within Brainvisa Example with the Saccades database

Breast MRI Accreditation Program Clinical Image Quality Guide

M R I Physics Course

fmri Basics: Spatial Pre-processing Workshop

Structural MRI of Amygdala Tutorial: Observation, Segmentation, Quantification

Data Loading & 3D Visualization

SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

ADNI, ADNI_QH, SURVEY. Geometry. connection

SCIRun Lab Walkthrough

Transcription:

Measuring baseline whole-brain perfusion on GE 3.0T using arterial spin labeling (ASL) MRI Revision date: 09/15/2008 Overview This document describes the procedure for measuring baseline whole-brain perfusion in humans using arterial spin labeling (ASL) MRI on GE 3.0T. ASL data are acquired using a modified flow-sensitive inversion recovery (FAIR) pulse sequence with interleaved spiral read out. Reconstruction of the data into AFNI briks is described. Additional calibration scans are required in order to allow quantification of the perfusion signals via a MATLAB script. Acquiring ASL data There are two protocols available: Brain_perfusion_4S and Brain_perfusion_SS, saved in the head section of the protocol list. The CMFRI webpage lists the pros and cons of these two protocols. Each of the protocols consists of 3 scans, ASL-FAIR, CSF and MinContrast. The ASL-FAIR scan collects perfusion-weighted data, and the CSF and MinContrast are calibration scans that are needed for perfusion quantification. A GE 8-channal phased array coil is used for all the scans. ASL-FAIR The ASL-FAIR acquisition uses a modified FAIR sequence. The global inversion pulse in standard FAIR is replaced by a spatially selective inversion pulse, which extends 10cm in either direction outside the imaging slab. QUIPSSII saturation pulses are applied. Some important pulse sequence parameters are: TI1=600 msec, TI2=1600 msec, TR=2.5sec, TE=minimum, FOV=22x22cm. The Brain_perfusion_4S sequence uses a spiral read out with 4 interleaves to reduce signal dropout due to susceptibility effects, and 20 tag+control image pairs are acquired. The Brain_perfusion_SS sequence uses a single shot spiral acquisition, collecting 50 tag+control image pairs. Below are the instructions on how to prescribe and acquire the ASL-FAIR scan. 1. View Edit the ASL-FAIR series. 2. Click Graphical Rx button and prescribe slices (Default: 20x5mm with 1mm gap, axial slices) Considerations for slice prescription: The slice orientation is defaulted to axial and the slice number increments from bottom to top. Please make sure not to change these default settings when prescribing slices. The default 20x5mm (1mm gap) imaging slab will provide full brain coverage for most subjects. When prescribing, place the lowest slice (i.e. slice No.1) at the very bottom edge of the brain region that you are interested in, and verify that the top slice covers the top edge of the desired region. If necessary, a few more slices can be added, but 1

only to the top of the slab. We do not recommend to use more than 22 slices. It is fine if a few top slices fall outside of the brain. 3. Save series and Prepare to scan 4. Scan Verify that the scan time is 6:40 minutes (Brain_perfusion_4S) or 4:10 minutes (Brain_perfusion_SS). CSF 1. View Edit 2. Copy Rx from the ASL-FAIR run (Note: The FOV and slice thickness/gap have to match those of the ASL_FAIR run in order to use Copy Rx.) 3. Save series and Prepare to scan 4. Click Manual Prescan, and once the clicking sound is heard, click Done. (this step ensures that no prescan is performed and all the gain settings are preserved from the ASL-FAIR scan). 5. Click Scan (Note: if you are using the old CSF protocol( scan time is 4sec for the old protocol, 36sec for the new protocol ), please wait ~ 30 seconds to allow for full relaxation of signal and then click Scan.) MinContrast 1. View Edit 2. Copy Rx from the ASL-FAIR scan. 3. Save series and Prepare to scan 4. Click Manual Prescan, once hearing clicking sound, click Done. 5. Scan Data transfer and reconstruction Unlike data acquired with GE product sequences, ASL data are stored as raw data in P- files in directory /usr/g/mrraw. Image reconstruction into AFNI briks is done automatically offline after the scan. Please allow time for reconstruction to finish (~5 minutes after the scan finishes) before transferring your data. Open a command tool and follow the instructions below: 1. cd /usr/g/mrraw 2. ls ltr P* to find the latest P-files. 3. To transfer the P-file and reconstructed brik: aslgecopy -s server r raid# -d datadir Pfilename brikname usrname (EXAMPLE: aslgecopy s cfmri r raid3 d 060601Pilot P01208.7 scan1 guest) Important Notes: The P-files created during ASL scans are stored in directory /usr/g/mrraw. The space available in this directory is NOT reflected in the storage bar on 2

the GE GUI. It is recommended that you check the space available before running any ASL scans. Do this by typing df k. in the command line after cd-ing to /usr/g/mrraw. Some sequence information is stored in the header of the AFNI briks. This information (including sequence parameters, ASL parameters and Rx info) can be accessed using the command (from within the directory containing the brik): 3dNotes scan1brik+orig The briks can be viewed in AFNI. Running the ASL a3/d3 plug-in on a brik will create three additional briks, labeled as follows: A3: running average of the data (using the 2 neighboring images) D3: running subtraction of the data (using the 2 neighboring images) avgd3: Average D3 (average perfusion image). Data reconstruction using SENSErc program (v1.2) - for multi-shot data only Multi-shot data, such as that acquired using the Brain_perfusion_4S sequence, is sensitive to modulations between shots caused by physiological fluctuations or motion. This can lead to significant image artifacts. The use of a SENSE reconstruction rather than a simple Fourier transform (as performed in the automatic reconstruction described above) significantly reduces sensitivity to these modulations and produces cleaner images. The SENSErc program is designed to reconstruct fully-sampled multi-shot spiral data using the SENSE algorithm. System Requirements Redhat linux 8.0 or above (Windows and Mac OS not supported). Matlab R14 service pack 1 or above. 512Mb or more available system memory recommended. AFNI v2.55j or above. FSL 3.x or FSL 4.0 (FSL 4.1 and above are not supported at this time). NOTE: FSL output type needs to be set to ANALYZE. To do this, in a command terminal type: setenv FSLOUTPUTTYPE ANALYZE or, if using a bash shell: export FSLOUTPUTTYPE=ANALYZE You can check your environment variable settings by typing: env Program Installation Download SENSErcv1.2_14x.tar from the cfmri website. (For data acquired before the 14x system upgrade, please download SENSErcv1.2.tar) Untar the file (in Linux: tar xvf SENSErcv1.0.tar). Add the SENSErc folder to Matlab path. 3

(e.g. add the line addpath yourpath/sensercv1.2_14x in your startup.m ) Required Data ASL P-file If CBF quantification is required, a CSF P-file is also needed. Reconstruction steps Start Matlab In Matlab command window, type: senserc({'pfilename1', Pfilename2 },{'AFNIprefix1', AFNIprefix2 }); e.g. senserc({'p02056.7', P03895.7 },{'senseasl, sensecsf }); Pfilenames are the names of the P files to be reconstructed AFNIprefixes are the prefixes of the AFNI briks that are output Important Notes: If CBF quantification is required, both the ASL and the CSF scans should be reconstructed using the SENSErc program; the minimum contrast data does not require this, and the brik created automatically at the scanner console should be used. The reconstruction is slow and may take several hours depending on the size of the raw data and the speed of the computer. This data reconstruction approach is NOT necessary or advised for data acquired using the single shot sequence (Brain_perfusion_SS). Perfusion Quantification using CBF program (v3.2) System Requirements Redhat linux 8.0 or above (Windows and Mac OS not supported). Matlab R14 service pack 1 or above, plus Matlab toolboxes. NOTE: If using Matlab release R2006b, you may encounter an incompatibility between Matlab s C++ libraries and your system s GCC. To solve this problem, force Matlab to use your system s libraries by deleting one of the Matlab libraries. Ask your system administrator (you need to be logged in as root) to execute the following commands: cd <matlab installation folder>/sys/os/glnx86 mv libgcc_s.so.1 libgcc_s.so.1_backup AFNI v2.55j or above. FSL 3.x or FSL 4.0 (FSL 4.1 and above are not supported at this time). NOTE: FSL output type needs to be set to ANALYZE. To do this, in a command terminal type: setenv FSLOUTPUTTYPE ANALYZE or, if using a bash shell: 4

export FSLOUTPUTTYPE=ANALYZE You can check your environment variable settings by typing: env 512Mb or more available system memory recommended. Not tested with 64-bit version of Linux Program Installation Download CBFv3.2.tar from the cfmri website. Untar the file (in Linux: tar xvf CBFv3.2.tar). Add the CBFv3.2 folder to your Matlab path. (e.g. add the line addpath yourpath/cbfv3.2 in your startup.m ) Required Data ASL-FAIR brik, CSF brik, MinContrast brik Optional: High resolution anatomical brik. NOTE: The anatomical brik must be created from the dicom files using the d2afni command rather than to3d. d2afni is available on the servers and simply calls to3d, additionally saving Rx information into the brik header. CBF Quantification Steps Start Matlab In Matlab command window, type: calccbf( ASL-FAIR, CSF, MinCon ); OR, if anatomical is available: calccbf( ASL-FAIR, CSF, MinCon, anat ); Note: Pass only the prefix of the Afni brik names (no +orig needed). If the SENSE reconstruction was used, take care to pass the SENSE ASL and CSF briks to calccbf, rather than the brik automatically transferred at the scanner console using aslgecopy. If anatomical is supplied: o The anatomical is segmented into gray, white and CSF (takes ~6mins). o All brain slices will then pop up in a matlab figure window; select those containing ventricles by left-clicking. If anatomical is NOT supplied: o A matlab figure window will pop-up. Identify a slice that best defines a region of cerebral-spinal fluid (CSF) (e.g. slice No. 12 in the figure below). Type the slice # in the matlab command window when prompted. Another window pops up containing the chosen CSF slice. Choose slice for CSF (beware partial-volumed slices!)? : 12 5

Use left mouse button to carefully trace around the edge of CSF region and double click to finish. If anatomical is supplied, this is performed for all chosen slices. (You may find double click does not work for certain version of matlab. In this case, please refer to the help file for roipoly in your matlab.) Note: this step creates a new directory called processed under your current working directory. A text file called CSFvalue.txt is saved under the new directory. This file contains the calculated CSF value, which will be automatically retrieved should you process the same dataset again (you will be prompted to choose whether or not to use this saved value in the repeated analysis). Note also that if the anatomical was supplied, this directory will also contain the rotated anatomical that aligns with the ASL slices, as well as partial volume maps created from the anatomical. 6

The calculated CBF maps are displayed in a new figure. If the anatomical was supplied, a histogram showing the CBF values within gray matter voxels is also shown. An AFNI brik containing the calibrated CBF values is also saved. Look for the suffix _CBF in the brik name. Many thanks to Dr. Joanna Perthen. Please contact kunlu@ucsd.edu with questions/comments 7