Refrigerant Gas Leak Detector. DC-IR2 R32 Available. Catalogue ver FUSO CO., LTD TOKYO JAPAN

Similar documents
ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual

Handheld Odor Meter OMX- SRM. Operation Manual. Ver. 1

Handheld Odor Meter OMX-ADM. Operation Manual. Ver

Digital Torque Screwdriver Model STC2-G

Model No INSTRUCTION MANUAL. Manual should be read prior to operation!

Gas detection just got personal

Vibration Meter Instruction Manual

GSM HOME SECURITY SYSTEM

SENSIT IRED INSTRUCTION MANUAL INFRARED ETHANE DETECTOR READ AND UNDERSTAND INSTRUCTIONS BEFORE USE. 851 Transport Drive Valparaiso, IN

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

Model No. SRG 2000 INSTRUCTION MANUAL. Manual should be read prior to operation!

Agenda. Charging the QRAE II

Operation Manual IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone: E-mai:

Flue Gas Analyzer. The Value Leader TM

ENGLISH. User manual.

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT

Oxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Currency Detector. Operation Manual South Grand Ave., Glendora, CA

Wireless Video Door Phone. User Manual

RS Stock No Instruction Manual RS Input Data Logging Thermometer

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

CDD4 Duct Carbon Dioxide Transmitter

Wide Range Pressure Meter Instruction Manual

D-TEK Select. Refrigerant Leak Detector

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

ETHOS Auto Ranging Digital Multimeter

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

PTR. printing temperature recorder. User Manual. order code:

Exposure Monitoring. Model 8560 INSPECTAIR CO 2. Meter. Operation and Service Manual , Revision B June 2006

User Guide. Kube Audio Clock II Charging Station with Bluetooth Audio and Alarm Clock

I. User Guide. 1. Structure. HD Lens. Speaker USB/TV port. 360 rotating clip Video/Confirm. Photo. OK/Menu. Audio. Reset. Up/Infrared HD 2 LCD.

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

SE-E7BT WIRELESS STEREO HEADPHONES. Operating Instructions

Indoor Air Quality Meter/Datalogger

Handheld Video Microscope

Datalogging IAQ Meter Instruction Manual

RH/Temperature SD Card Datalogger. Instruction Manual

Visible Light SD Card Datalogger

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

Model BS-150. Instruction Manual. Video Inspection Camera. reedinstruments. www. com

Type K/J Thermometers

Leak Sensor. TOYOKO KAGAKU CO., LTD. Kawasaki, Kanagawa, Japan

SRT5000 Surface Roughness Tester. Instruction Manual

IV-18 (ИВ-18) VFD Tube Clock. Instructions. Contents. v Energy Pillar

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Handy Calibrators

Anemometer SD Card Datalogger. Instruction Manual

Carbon Dioxide Monitor/Controller With The USB Data Logger

ST Model. Instruction Manual. Multi-Function Environment Meter. reedinstruments. www. com

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

Wireless Inspection Camera with recording LCD monitor. Product code: SRCAMV6 CAMERA NUMBER:

Car air purifier USER S GUIDE ver. 1.0 EN

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

0.01kV (0 to ±0.99 kv)

Operation Manual for Multifunctional Data Logger. HUATO Electronic Co., LTD.

MANUAL SURFACE ROUGHNESS TESTER TR-200 PARTNERS IN PRECISION

MSR BASIC & MSR NANO USER MANUAL

TABLE OF CONTENTS. Table of Contents. Table of Figures

The Specification of Hot Wire Anemometer Manual PCE-423

INSTRUCTIONS Read this manual carefully before using your camera.

USER MANUAL Video Particle Counter with built in Camera Model VPC300

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

CT-510. Multifunctional CCTV Tester. User Manual

Air Ion Counter - Operation Manual MOC 320 Oct. 16

PH SD Card Datalogger. Instruction Manual

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

SENSIT HCN. Accessories. Replacement Parts. Calibration Kits. Calibration Gases MADE IN THE USA WITH GLOBALLY SOURCED COMPONENTS

GA-12. madur Polska sp. z o.o.

SOLAR POWER METER TM-206. User s Manual HB1TM

Safety Information. Introduction. 1.1 Precaution before using the tester. 1.2 Precautions when using the tester

Handheld Video Magnifier

AVM-8880 USB Logging Anemometer

Thanks for you purchasing of this product. Please kindly read this user manual and keep it carefully for reference.

2.4-inch Dash Cam. Model No.: PKC0VER. Owner s Manual. and Warranty Information

D-TEK Select. Refrigerant Leak Detector

CAR VIDEO REGISTRATOR

DPL4000 Portable Low Range Dew Point Analyzer

Acaia Pearl Operation Manual

ZigBee Temperature and Humidity Data Logger User s Manual Ver Contents

GPS Vehicle and personal location tracker. User manual

PWDBT Bluetooth Mobile Speaker USER GUIDE

TENMA INSTRUCTION MANUAL MULTI-TESTER

Action-Sports Camera User Manual. Please read through the complete User Manual before using your JAKD

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER MAS830 MAS830L

acaia Coffee Scale Operation Manual

CCTV Tester. User s Manual

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Installation and operation manual ReciFlow Gas

E4PA. Ultrasonic Displacement Sensor. Ordering Information

4-Channel Thermometer

E2Q4 Square Proximity Sensor

Camping light ELBA with 4x 3W COB LED Item no

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

Commander for wireless flash shooting Canon INSTRUCTION MANUAL

Owner s Manual v1.0.0

HD 9609 INSTRUCTIONS MANUAL

TEST & MEASUREMENT NEW NEW NEW FULL RANGE OF TEST & MEASUREMENT DEVICES. micro DM-100. micro CM-100. micro HM-100. micro LM-100 Laser Distance Meter

1. Introduction. 2. Product Overview Appearance Buttons/Mini USB Interface Description. UBI5000E User Manual

Transcription:

Refrigerant Gas Leak Detector DC-IR2 R32 Available Catalogue ver.20130715 FUSO CO., LTD TOKYO JAPAN

Features Below are some of the key features and capabilities of the DC-IR2. The non-distributing infrared absorption method NDIR sensor avoid an incorrect detection. Since gas selectivity can be improved taking advantage of the characteristic, an incorrect reaction like a semiconductor type can be inhibited. The DC-IR2 detects leaks as small as Turbo 2g/year. ( not influenced by the atmosphere) Auto zero function button is loaded : convenient at the time of atmosphere is polluted. A four-step setup of detection sensitivity of every ; Low, Mid, Hi and Turbo detection mode is possible for this machine. The eight segments LED display and beep sound indicates the degree of change in refrigerant concentration. Moreover, detection is told by three kinds of methods, a buzzer, an indicator, and vibrator. Operation can be easily confirmed with the check Leak (sample gas for the examination). The LED luminescence lamp was also carried at the tip of a suction part so that a detection part might be known even dark. The holster (rubber protector) is attached to the side. It is easy to fit the hand and to have it. Hard carrying case (convenient for carrying ) The charge plug with AC adapter and the car cigar socket (convenient for long-time use) is attached by default. Automatic power OFF function to disconnect the power when not in use. (10 minutes) To prevent ON / OFF of power due to the contact wrong, enable this operation Press and hold more than 2 seconds to effect. A belt and a strong magnet can be put up to the holster. ( When magnetism is fixed to the fall prevention and the metal department) With a probe and a narrow nozzle attachment for the extension are attached; It is convenient for the inspection of the point that can t reach the hand.

The Name of Each Part Figure 3.1

Display and Operation Button Battery Level Buzzer, Mute Indication Multi color LED bar Indicator (Indicates the amount of the leakage) Gas Type Indication (Currently selected) Vibration Indication (Displayed when the vibration mode is enabled) Peak Hold Mode (For memorize the peak value) READY Indication (displayed after warm-up) Sensitivity Indication ; L/M/H/Turbo (=Flashing H button) Alarm Method Button; (Buzzer, Vibration, Mute) LED Light Button A white LED light at the probe tip enables the examination in the dark place Power Button / Zero Button Press and hold the button (2 or more seconds) to switch on/off the power supply./ *If you press the button just one second, resets the current environment gas level to Zero. Gas Type Button Select from below; R22 R134a R404A R407C R410A R1234 R32 and other gas Peak Hold/ Turbo Mode Button (For memorize the peak value) * by pressing this button 4 times to enable Turbo Sensitivity Mode. Sensitivity Button ; by pressing this button to switch L/M/H mode Figure 3.2 Display and Operation Button

Specifications Model Detection Method Usage Detectable Gases Sensitivity Alarm Method Battery /Battery Life/ Charging Time Operating Temperature & Humidity Flexible Hose Length Dimension / Weight Accessories Option Goods DC-IR2 Infrared Detect Freon Gas Leak R12 R22 R134a R404A R407C R410A R32 R1234yf etc CFC/HFC/HCFC/HFO Gas Coolant Turbo H M L R12 2g/year 3g/year 5g/year 15g/year R22 R134a 2g/year 3g/year 5g/year 15g/year R404A 407C 410A 2g/year 3g/year 5g/year 15g/year R32 R1234yf 2g/year 3g/year 5g/year 15g/year Buzzer LCD color Indicator Vibrator Lithium ion battery/approx. 8hours/Less than 5hours 0 ~40 0%~75%RH 300mm 220L 65W 42D mm approx.350g AC adapter Cigar socket adapter Extension Probe Narrow Nozzle Attachment Filter x10 O-Ring x5 Magnetic Strap(belt) Check Leak bottle User Manual Hard Carrying Case Filter x 10 Test Leak FUSO Co., Ltd. Tornare Nihonbashi Hamacho Bldg., 3-3-1-214, Nihonbashi hamacho, Chuo-ku, Tokyo 103-0007 JAPAN TEL: +81-3-5652-1151 FAX: +81-3-5652-1161 Email: info@fusorika.co.jp URL: http://www.fusorika.co.jp