MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

Similar documents
CTC Low Temperature Process Chillers

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

AuraCool Economizer System

GP SERIES Packaged Chillers

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

WO P-NF-L-M-407c Spec Submittal

HIGH EFFICIENCY Central Chiller

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

J&M Fluidics, Inc. Company Product Overview

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Trailblazer AGZ-E air-cooled scroll chillers

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Specification and Design Catalog. Waterside Economizer

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

Ecoflair Air Economizers

MC Series Drives. Flexible, simple, rugged, robust!

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

Liebert HPC Freecooling Chiller

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Table of Contents. Executive Summary Site and Unit Background Chiller Chiller Appendix... 11

Precision Cooling Mission Critical Air Handling Units

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Liebert. DSE Thermal Management System Free Cooling Economization Without Using Water

Semi-hermetic Air-cooled Condensing Units

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

kyalfa V- VDD/VDD6 General Contents

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

Fair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

Precision Cooling. Precision Cooling Advantages

Ecotel Free Cool 5-15kW

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

Rack cooling solutions for high density racks management, from 10 to 75 kw

SSW06. Soft Starters.

Flow Measurement Applications

SOLUTIONS ONICON. Innovative HVAC Flow and Energy Measurement Solutions PRECISE, RELIABLE, TRUSTED

Cooling Solutions & Considerations for High Performance Computers

AIR COOLED CONDENSERS

Aquaflair. BREC/F and BCEC/F kw

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

DATA CENTER LIQUID COOLING

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

How To Draw Chiller Monsters Werewolves Vampires And Zombies

4-step Chiller and Heat Pump Controller

CL20 Rear Cooler. New Generation Computer Room Cooling

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Datasheet.

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

Lenntech BMP GRUNDFOS DATA BOOKLET. High-pressure piston pumps 50/60 Hz

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Standard Circulating Pumps

We design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

Product Submittal. Project Information Project Name: Ulta 1307 Seneca SC. Customer Information Company Name: Engineering Information Company Name:

Isotemp. Bath Circulators. Improve the productivity. of your lab with solutions. from Fisher Scientific

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

Retro-Commissioning Report

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Data Center Optimized Controls

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Sealed Enclosure Cooling Air Conditioners

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

Strip Till. Ultimate in Strip Till Versatility & Performance. The. Toll Free:

Transcription:

INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM

When commercial grade isn t enough Businesses who function in today s advanced industrial manufacturing and mission critical environments depend on chiller systems to provide a reliable source of chilled water, which can improve overall system uptime and efficiencies. Every critical cooling application is unique, which is why the Motivair MLC chillers have been designed to accommodate a wide range of operating points and customization based specifically on the needs of the customer. No other air-cooled chiller offers such a broad range of features and benefits that can be used in combination to create a chiller best suited for your business s needs. As an industry leader, we aim to deliver innovative products, reliable solutions and an unwavering commitment to excellence.

INNOVATE DESIGN APPLY www.motivaircorp.com Application Defined Features Compressor Options Condenser Fan Options Evaporator Additional Options All MLC chillers feature two heavy-duty, 3500RPM semi-hermetic screw compressors mounted in two completely independent refrigeration circuits. Each compressor features four steps of unloading for virtually unlimited capacity control. Compressor options: n S tandard Screw Compressor n V ariable Speed Screw Compressor n L ow-temperature Screw Compressor Fans feature heavyduty, composite blades, which do not flex or lose efficiency at the top of their performance curve. Motors feature reversed stator and rotor, eliminating the traditional motor shaft. Motors are TEAO; suitable for outdoor use, and variable speed operation. Optional EC fan technology available. The MLC & MLC-FC chillers feature an ASME U stamped, dual circuited evaporator mounted on the chiller base. Carbon steel shell with heavy gauge copper tubes insures long life and highly efficient heat transfer under varying loads. All MLC evaporators feature removable end bonnets and pressure relief valves. Available options include: n S implex (1) Pump Package n D uplex (2) Pump Package n Storage Tank n L ow Noise or Ultra Low Noise Package n H igh Ambient Package n Stainless Steel Cabinet Construction n Condenser Coil Coating n Security Guards for Open Areas n Integrated FreeCooling System n Adiabatic System

Integrated Free-Cooling: The Ultimate Solution for Optimal Energy Savings The Motivair MLC-FC chillers with Free-Cooling capability are designed to provide the owner with optimal performance, year-round, in varying ambient temperatures. This Free-Cooling option, available on models MLC-FC 200 MLC-FC 1750 is supplied with Free-Cooling coil and the PC05 advanced PLC control package a unique single package for yearround energy savings. The refrigerant plant is designed to cool the designated heat load during the highest summer temperatures. When ambient temperatures fall overnight or during cooler seasonal weather, the integrated Free-Cooling system is automatically activated. The system operates by directing the return chilled glycol through the Free- Cooling coil, before it enters the evaporator. This is achieved via an automatic motorized valve, controlled the PLC, whenever the ambient falls below the return chilled glycol temperature set point. The glycol is either partially or completely cooled in the Free Cooling coil for maximum energy savings. As result, less mechanical refrigeration is required to achieve the chilled glycol set point, and the refrigeration compressors are cycled off by the PLC, which continuously monitors the system. switching between mechanical cooling and Free Cooling allows for optimal performance year-round. As a general guideline, Free-Cooling savings more than pay for the initial investment in the first year of operation. The pioneer of free-cooling chillers, Motivair is the only U.S. supplier with a cataloged and tested Free-Cooling chiller range n MLC-FC Chiller Range has been designed, built and tested specifically as packaged Free Cooling Chillers n NO aftermarket or 3rd party add-on free cooling coils, components or controls n ETL-Tested and Listed to current UL & CSA standards PLC CONTROLLER 21.6 COMPRESSOR Energy savings in areas with cooler winter months are substantial. Wear and tear on chiller components is dramatically reduced, due to fewer running hours during winter months. Automatic GLYCOL IN TEMP SENSOR 3-WAY VALVE FANS CONDENSER / FREE COOLING COIL EVAPORATOR EXP VALVE TEMP SENSOR TEMP SENSOR PUMP STORAGE TANK INNOVATIVE PRODUCTS DESIGN FLEXIBILITY GLYCOL OUT

INNOVATE DESIGN APPLY www.motivaircorp.com Adiabatic Efficiency Boosting System Air-Cooled Chiller System Free-Cooling Chiller Systems The Motivair Adiabatic Efficiency Boosting System uses a proprietary evaporative Pre-Cooling media designed to precool warm ambient air before it reaches the air-cooled chiller condenser coils. Motivair Free-Cooling chillers can be ordered with the adiabatic option fitted. By automatically turning on the system when Free Cooling is active and the ambient temperature is above freezing, partial and 100% FreeCooling operating hours can be significantly increased. This allows the refrigeration compressors to be turned off for longer periods of time, in addition to the improved summer air cooled efficiency described above. During warmer seasonal weather, the Adiabatic System automatically activates and allows a small flow of city water to wet the evaporative media. Warm, dry air first passes through the evaporative media where it is pre-cooled before it enters the condenser coils. Water that is not evaporated is collected and recycled. Depending on geographic location, inlet air temperatures can be reduced by up to 20 F yielding significant chiller efficiency gains, increased reliability during extreme summer weather and reduced building energy demand loads. The evaporative media is specifically designed for ultra-low pressure drop with virtually no added static to condenser fans. As a factory supplied option, media thickness and air flow velocities are designed to allow zero water carry over onto the chiller coils. The evaporative media is easily removed for field service, cleaning or inexpensive replacement. Virtually maintenance-free and requiring little or no water treatment, the Adiabatic System is ideal for clients seeking simple and reliable efficiency gains for their air-cooled chiller system. The Adiabatic System is controlled and protected by the proprietary Motivair chiller PLC software and is completely automatic including auto fill, winter drain down, low water level and anti-freeze alarms.

PLC Controls The MLC range features the PCO5 control system, which is an advanced Programmable Logic Controller, with a baseoperating platform that can be easily modified to adapt to various applications. A multi-character LCD display, and easy to follow directional prompts, gives the operator complete control over all chiller functions. Multiple digital and analog inputs as well as digital and PWM outputs offer unparalleled control possibilities. PC05 Display Intelligent Chiller Response PC05 Board The Latest generation of Motivair software allows the chillers to respond to system changes in real time and to adjust performance accordingly. The proprietary control logic in the MLC or MLC-FC chillers provides: n Automatic restart after a power outage n Rapid restart of refrigeration compressors after Control features of the PCO5 include: n Highly visible LCD display n Low refrigeration pressure n Tactile push-buttons alarm n Adjustable alarm set points n High refrigeration pressure n F/ C selectable alarm n Compressor Lead/Lag control n Irregular voltage alarm n Anti-Compressor short cycle n General Alarm Relay n Compressor failure alarm n Remote Start/Stop Relay n Adjustable water set point n Manual alarm reset n Supply water temp. display n RS 232/RS 485 n Return water temp. display communication n Low water temperature alarm n Ethernet Communication n Freeze alarm n LON, BACNET, MODBUS n Low water/glycol flow alarm communication (optional) n High water temperature alarm a power outage, while affording maximum compressor protection n Selective decision on which compressor(s) to start first based on run-time and fastest possible response to system load n Liquid injection to the compressors under high ambient operation n Seamless transition between refrigeration and optional Free Cooling mode based on system load, chilled water temperature, ambient temperatures and installation profile. Centurion Monitoring System This optional feature empowers the owner by providing a wide range of safeties and access to critical data from a remote location via cellular service, outside of the customer s firewall. If the chiller is operating in an unsafe condition or in the unlikely event of an alarm, designated contacts are immediately notified by the chiller of its condition. The pending alarm can then be avoided or quickly corrected. Features: n Data trending n Password protected multi-level access INNOVATIVE PRODUCTS DESIGN FLEXIBILITY n Adjustable warning thresholds

MLC & MLC-FC Specifications MLC & MLC-FC CHILLER RANGE WITH SCREW COMPRESSORS MLC 200 270 340 390 510 560 600 660 820 930 1100 1150 1200 1400 1600 1750 Nominal Cooling Capacity* BTU/HR 692,906 849,526 972,950 1,249,580 1,471,259 1,817,046 2,054,367 2,312,008 2,542,532 2,976,465 3,437,480 4,034,146 4,427,370 4,624,016 5,085,064 5,953,930 Nominal Cooling Capacity TON 57.7 70.8 81.1 104.1 122.6 151.4 171.2 192.7 211.9 248.0 286.5 336.2 368.9 385.3 423.7 496.0 100% Free Cooling Ambient Temperature F 32.0 28.0 26.0 26.0 23.0 23.0 23.0 24.0 22.0 22.0 22.0 24.0 22.0 24.0 22.0 22.0 Refrigerating Circuit QTY 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 Screw Compressor QTY 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 Capacity Steps (Per Compressor) QTY 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 FANS & CONDENSER Axial EC Fans & Copper Tube with Aluminum Fin Condenser MLC Electronic Fan Speed Control QTY 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 MLC Total Condenser Air Flow CFM 72,848 67,273 64,273 64,273 85,697 85,697 107,121 128,545 128,545 171,394 171,394 214,242 235,667 257,090 257,090 342,788 MLC Fans QTY 4 6 6 6 8 8 10 12 12 16 16 20 22 24 24 32 MLC Fans Total Nominal Power HP 8 12 12 12 16 16 20 24 24 32 32 40 44 48 48 64 MLC-FC Elecronic Fan Speed Control QTY 2 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 MLC-FC Total Condenser Air Flow CFM 60,035 60,035 60,035 80,047 80,047 100,058 120,070 140,082 140,082 160,093 180,105 220,128 220,128 280,164 280,164 320,186 MLC-FC Fans QTY 6 6 6 8 8 10 12 14 14 16 18 22 22 28 32 36 MLC-FC Fans Total Absorbed Power HP 12 12 12 16 16 20 24 28 28 32 36 44 44 56 64 72 PUMP & TANK (OPTIONAL) Simplex or Duplex Pump Options, Carbon Steel or Stainless Steel Tank Options Nominal Flow GPM 140 171 196 252 296 366 414 466 512 600 692 813 892 932 1,024 1,200 Optional Pump Pressure PSI 39.2 43.5 30.5 33.4 33.4 35 35.5 36.3 43.5 40.6 45 37.7 46.4 N/A N/A N/A Optional Pump Absorbed Power HP 7.5 10 10 15 15 20 25 25 30 30 40 50 60 N/A N/A N/A Optional Pump Absorbed Current A 11 14 14 21 21 27 34 34 40 40 52 65 77 N/A N/A N/A Flanged Chilled Water Connections IN 4 4 4 5 5 6 6 6 6 8 8 8 8 8 8 8 Optional Tank Volume GAL 150 150 150 150 150 150 200 200 200 N/A N/A N/A N/A N/A N/A N/A ELECTRICAL DATA Does not include optional pump(s) Power Circuit V/Ph/Hz 460/3/60 (575/3/60 Optional) Auxiliary Circuit V/Ph/Hz (230-24)/1/60 MLC Full Load Amps (FLA) A 106 127.8 138.9 189.1 218.5 274.4 311.9 336.7 386.5 459 510.2 585.5 654.1 673.4 773 918 MLC Min Circuit Ampacity (MCA) A 117.3 140.9 153.4 209.9 242 304.9 346.2 373.1 429.1 508.8 566.3 649.2 725.4 709.8 815.6 967.8 MLC Max Overcurrent Protection (MOP) A 162.7 193.5 211.5 293.1 336 426.8 483.1 518.7 599.5 707.9 791 903.9 1010.7 855.4 986.1 1,166.9 MLC-FC Full Load Amps (FLA) A 113.8 129.6 142.7 196.7 224.1 276.9 320.1 336.1 389.2 459.9 508.3 616.8 704.9 672.2 778.4 919.8 MLC-FC Min Circuit Ampacity (MCA) A 125.2 143 157.6 217.5 248.3 306.8 345.4 374.3 434 513.1 567 683.5 782.6 710.4 823.3 972.9 MLC-FC Max Overcurrent Protection (MOP) A 170.6 196.4 217.6 300.7 345.2 426.2 491.7 527.1 613.3 725.6 801.5 950.1 1093.3 863.2 1002.6 1,185.5 NOISE DATA Distance measured in an open field at 33ft from condenser MLC Sound Pressure Level dba 65.1 66.7 67.9 67.4 68 70.4 72 71.3 71.5 72.6 72.8 73.7 74.4 72.8 73.7 74.4 MLC-FC Sound Pressure Level dba 65.9 66.7 67.9 67.9 68 70.7 72.2 71.5 71.8 72.6 72.9 73.8 74.4 72.9 73.8 74.4 DIMENSIONS & WEIGHTS MLC Length IN 122 159.4 159.4 159.4 196.9 196.9 234.3 271.7 271.7 346.5 346.5 421.3 458.7 567.4 567.4 693 MLC Width IN 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 MLC Height IN 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 MLC-FC Length IN 159.4 159.4 159.4 196.9 196.9 234.3 271.7 309.1 309.1 346.5 383.9 458.7 458.7 618.2 618.2 693 MLC-FC Width IN 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 MLC-FC Height IN 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 96.5 MLC Weight - Dry Weight LBS 6,945 9,039 9,259 9,480 10,141 10,362 12,897 14,330 14,551 18,519 18,739 22,928 24,912 28,660 29,102 37,038 MLC-FC Weight - Dry Weight LBS 9,480 9,675 9,921 11,244 11,485 13,669 15,432 17,637 18,078 19,290 21,385 25,574 25,904 35,274 36,156 38,580 Performance rated at 44 F LWT / 54 F EWT / 95 F Ambient / 100% Water. Chiller capacity changes with operating conditions, consult Motivair for assistance. 2017 Motivair Corporation. Motivair reserves the right to modify specifications without notice. Reproduction of this brochure in whole or in part is prohibited.

OUR BUSINESS IS COOLING YOURS MPC & MPC-FC 1/2-50 ton packaged air-cooled or water-cooled chillers for Industrial cooling, Medical cooling or custom HVAC applications. Includes integrated microprocessor, pump station, and storage reservoir. MLC-SC Air-Cooled Scroll Chillers 100 285 tons air-cooled with scroll compressors to accommodate a wide range of operating points and customization for today s advanced industrial manufacturing and mission critical environments. Available Integrated Free-Cooling. PTS Pump/Tank Stations for chillers and cooling systems. Standard and custom designs available. MFC Closed loop dry-coolers for process cooling and remote Free-Cooling applications. Chilled Door Rack Cooling System Advanced server rack cooling system fits and standard or OEM computer rack. Removes up to 75 kw of server heat per door. Learn more at www.chilleddoor.com CDU The Coolant Distribution Unit (CDU) provides 100% sensible cooling up to 1.25MW, depending on the model. For use with the ChilledDoor or other IT cooling systems. 01/2017 Printed on Recycled Stock with 10% Post Consumer Fiber. 85 Woodridge Drive Amherst, NY 14228 Tel: 716-691-9222 Fax: 716-691-9229 www.motivaircorp.com