1 Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA R22 R404A R507
2 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable pressure control and start controls mounted and wired. Electronic motor protection on all compressors. Oil failure controls on 8 HP and larger models. Copper tube / aluminum fin condensers. Compact flat base design up to 8 HP. CSA International approval, file , on DFA models. UL recognized, file SA2372, on V DTA models HFA Outdoor Model Standard Features All the features of the DFA Indoor models plus: Low ambient head pressure controls. Galvanized and aluminum outdoor enclosures, rain tested to CAN/CSA -C22.2 / UL1995 standard, all sizes. Quick enclosure disassembly for four side service access. Threaded bolt and nut panel fasteners instead of sheet metal screws. Enclosure design eliminates airflow short circuiting CSA International approval, file , on HFA models. UL recognized, file SA2372, on V HTA models Performance Data Capacities are based upon 60Hz operation, 65 F return gas temperature, 5 F sub-cooling and 90 F ambient. Evaporating Temperature ( F) Model DFA KC-S 1,400 2,600 3,900 4,600 5,400 DFA JC-S 2,600 3,900 5,300 6,100 7,000 DFA HC-S 3,700 5,200 6,900 7,800 8,800 DFA GC-S 4,400 6,100 8,100 9,100 10,200 DFA FC-S 5,900 8,100 10,500 11,900 13,300 DFA EC-S 6,400 8,900 11,700 13,300 14,900 DFA DC-S 7,800 10,900 14,400 16,400 18,400 DFA CC-S 9,700 13,300 17,300 19,500 21,800 DFA FC-S 11,200 16,000 21,500 24,500 27,800 DFA EC-S 14,000 19,500 26,000 29,500 33,300 DFA DC-S 16,500 23,100 30,600 34,700 39,100 DFA V-S 20,800 28,600 37,800 42,900 48,400 DFA T-S 25,500 35,100 46,300 52,500 59,000 DFA KC-S 4,600 5,400 7,100 9,000 11,100 13,300 DFA JC-S 6,100 7,000 8,900 10,900 13,100 15,500 DFA HC-S 8,600 9,800 12,300 15,100 18,200 21,500 DFA GC-S 10,100 11,300 14,100 17,200 20,600 24,300 DFA FC-S 12,500 14,000 17,500 21,300 25,600 30,300 DFA EC-S 14,100 15,900 19,900 24,400 29,300 34,800 DFA DC-S 18,300 20,700 26,100 32,300 39,300 47,200 DFA CC-S 22,400 25,200 31,500 38,700 46,700 55,500 DFA FC-S 24,600 27,900 35,100 43,300 52,500 62,600 DFA EC-S 30,300 34,300 42,900 52,700 63,500 75,500 DFA DC-S 36,800 41,600 52,100 64,000 77,100 91,600 DTA V-S 46,100 52,200 65,800 81,400 99, ,500 DTA T-S 56,700 64,100 80,600 99, , ,700
3 R404A / R507 Performance Data Capacities are based upon 60Hz operation, 65 F return gas temperature, 5 F subcooling and 90 F ambient. Evaporating Temperature ( F) Model DFA KC-S 1,000 1,600 2,500 3,400 4,600 5,200 5,900 7,400 9,000 10,800 DFA JC-S 1,400 2,400 3,400 4,700 6,000 6,800 7,600 9,200 11,000 12,800 DFA HC-S 2,000 3,100 4,400 5,800 7,400 8,200 9,100 DFA GC-S 2,400 3,700 5,100 6,700 8,400 9,300 10,200 DFA FC-S 3,300 4,900 6,900 9,100 11,600 12,900 14,300 DFA EC-S 4,000 6,000 8,200 10,700 13,600 15,100 16,700 DFA DC-S 4,800 7,200 9,900 13,000 16,500 18,400 20,400 DFA CC-S 5,800 8,700 12,000 15,800 20,000 22,200 24,400 DFA FC-S 6,900 10,400 14,500 19,300 24,800 27,900 31,100 DFA EC-S 8,900 13,000 17,900 23,400 29,700 33,100 36,700 DFA DC-S 10,400 15,400 21,200 27,700 35,100 39,000 43,200 DFA CC-S 13,000 19,000 25,800 33,500 41,900 46,500 51,300 DFA V-S 13,000 18,900 25,800 33,600 42,400 47,100 52,000 DFA T-S 16,500 23,700 31,900 41,100 51,400 57,000 62,800 DTA P-S 19,300 28,100 38,400 50,200 63,600 70,900 78,600 DTA N-S 23,300 33,300 44,900 57,900 72,500 80,300 88,500 DFA HC-S 6,600 8,500 9,600 10,700 13,300 16,100 DFA GC-S 7,700 9,900 11,100 12,300 15,100 18,100 21,400 DFA FC-S 9,100 11,600 12,900 14,300 17,300 20,500 23,900 DFA EC-S 11,400 14,600 16,300 18,200 22,100 26,300 30,900 DFA DC-S 13,200 16,800 18,800 20,800 25,200 29,800 DFA CC-S 17,500 22,600 25,400 28,200 34,900 42,000 49,800 DFA FC-S 19,400 24,900 28,000 31,200 38,100 45,800 54,100 DFA EC-S 24,000 30,600 34,200 38,000 46,100 55,000 64,600 DFA DC-S 29,100 37,100 41,500 46,100 56,000 66,800 78,600 DTA V-S 36,000 46,200 51,800 57,700 70,500 84, ,400 DTA T-S 44,600 56,900 63,500 70,600 86, , ,600 Compressor Application Limits SCT [ F] SH < 35 F R22 Standard SCT [ F] 120 RGT < 45 F OCTAGON R404A R Motor Motor 2 RGT 65 [ F] SST [ F] 100 Motor 1 80 Motor 2 RGT 65 [ F] SST [ F]
4 208V & 230V Notes No Comp /1/ /3/60 Model of Model Comp. Fan Unit Comp. Fan Unit Fans No. RLA LRA HP FLA MCA FUSE RLA LRA HP FLA MCA FUSE DFA KC-S P 1 2KC / / DFA JC-S P 1 2JC / / DFA HC-S P 1 2HC / / DFA GC-S P 1 2GC / / DFA FC-S P 2 2FC / / DFA EC-S P 2 2EC / DFA DC-S P 2 2DC / DFA CC-S P 2 2CC / / DFA FC-S P 2 4FC / DFA EC-S P 2 4EC / DFA DC-S P 2 4DC / DFA V-S O,P 2 4V / DFA T-S O,P 2 4T / DFA KC-S P 1 2KC / / DFA JC-S P 1 2JC / / DFA HC-S P 2 2HC / / DFA GC-S P 2 2GC / / DFA FC-S P 2 2FC / DFA EC-S P 2 2EC / / DFA DC-S P 2 2DC / / DFA CC-S P 2 2CC / DFA FC-S P 2 4FC / DFA EC-S P 2 4EC / DFA DC-S P 2 4DC / DTA V-S O,P 2 4V / DTA T-S O,P 2 4T / DFA KC-S P 1 2KC-05.2Y / / DFA JC-S P 1 2JC-07.2Y / / DFA HC-S P 1 2HC-1.2Y / / DFA GC-S P 1 2GC-2.2Y / / DFA FC-S P 2 2FC-2.2Y / / DFA EC-S P 2 2EC-2.2Y / / DFA DC-S P 2 2DC-2.2Y / DFA CC-S P 2 2CC-3.2Y / DFA FC-S P 2 4FC-3.2Y / DFA EC-S P 2 4EC-4.2Y / DFA DC-S P 2 4DC-5.2Y / DFA CC-S P 2 4CC-6.2Y / DFA V-S O,P 2 4V-6.2Y / DFA T-S O,P 2 4T-8.2Y / DTA P-S O,P 2 4P-10.2Y / DTA N-S O,P 2 4N-12.2Y / DFA HC-S P 2 2HC-2.2Y / / DFA GC-S P 2 2GC-2.2Y / / DFA FC-S P 2 2FC-3.2Y / DFA EC-S P 2 2EC-3.2Y / / DFA DC-S P 2 2DC-3.2Y / DFA CC-S P 2 2CC-4.2Y / DFA FC-S P 2 4FC-5.2Y / DFA EC-S P 2 4EC-6.2Y / DFA DC-S P 2 4FC-7.2Y / DTA V-S O,P 2 4V-10.2Y / DTA T-S O,P 2 4T-12.2Y / Notes: P = Dual (HP/LP) pressure controls included. O = Oil failure control included. MCA = Minimum circuit ampacity.
5 460V & 575V Notes No Comp. 460/3/60 575/3/60 Model of Model Comp. Fan Unit Comp. Fan Unit Fans No. RLA LRA HP FLA MCA FUSE RLA LRA HP FLA MCA FUSE DFA KC-S P 1 2KC / DFA JC-S P 1 2JC / DFA HC-S P 1 2HC / / DFA GC-S P 1 2GC / / DFA FC-S P 2 2FC / / DFA EC-S P 2 2EC / / DFA DC-S P 2 2DC / / DFA CC-S P 2 2CC / / DFA FC-S P 2 4FC / / DFA EC-S P 2 4EC / / DFA DC-S P 2 4DC / / DFA V-S O,P 2 4V / / DFA T-S O,P 2 4T / / DFA KC-S P 1 2KC / DFA JC-S P 1 2JC / DFA HC-S P 2 2HC / / DFA GC-S P 2 2GC / / DFA FC-S P 2 2FC / / DFA EC-S P 2 2EC / / DFA DC-S P 2 2DC / / DFA CC-S P 2 2CC / / DFA FC-S P 2 4FC / / DFA EC-S P 2 4EC / / DFA DC-S P 2 4DC / / DTA V-S O,P 2 4V / / DTA T-S O,P 2 4T / / DFA KC-S P 1 2KC-05.2Y / DFA JC-S P 1 2JC-07.2Y / DFA HC-S P 1 2HC-1.2Y / / DFA GC-S P 1 2GC-2.2Y / / DFA FC-S P 2 2FC-2.2Y / / DFA EC-S P 2 2EC-2.2Y / / DFA DC-S P 2 2DC-2.2Y / / DFA CC-S P 2 2CC-3.2Y / / DFA FC-S P 2 4FC-3.2Y / / DFA EC-S P 2 4EC-4.2Y / / DFA DC-S P 2 4DC-5.2Y / / DFA CC-S P 2 4CC-6.2Y / / DFA V-S O,P 2 4V-6.2Y / / DFA T-S O,P 2 4T-8.2Y / / DTA P-S O,P 2 4P-10.2Y / / DTA N-S O,P 2 4N-12.2Y / / DFA HC-S P 2 2HC-2.2Y / / DFA GC-S P 2 2GC-2.2Y / / DFA FC-S P 2 2FC-3.2Y / / DFA EC-S P 2 2EC-3.2Y / / DFA DC-S P 2 2DC-3.2Y / / DFA CC-S P 2 2CC-4.2Y / / DFA FC-S P 2 4FC-5.2Y / / DFA EC-S P 2 4EC-6.2Y / / DFA DC-S P 2 4FC-7.2Y / / DTA V-S O,P 2 4V-10.2Y / / DTA T-S O,P 2 4T-12.2Y / / Notes: P = Dual (HP/LP) pressure controls included. O = Oil failure control included. MCA = Minimum circuit ampacity.
6 Dimensions Indoor (DFA) Models Outdoor (HFA) Models Nom. Service Valves Receiver Dimensions Approx. Dimensions Approx. Model HP Liq Suc Capacity L W H Ship Wt. Hood L W H Ship Wt. (in) (in) 90% (lb) (in) (in) (in) (lb) Size (in) (in) (in) (lb) DFA KC-S 1/2 3/8 5/ DFA JC-S 3/4 3/8 5/ DFA HC-S 1 3/8 5/ DFA GC-S 1-1/2 3/8 5/ DFA FC-S 1-1/2 3/8 5/ DFA EC-S 2 1/2 7/ DFA DC-S 2 1/2 7/ DFA CC-S 3 1/2 7/ DFA FC-S 3 1/2 7/ DFA EC-S 4 1/2 1-1/ DFA DC-S 5-1/2 1/2 1-1/ DFA V-S 5-1/2 1/2 1-1/ DFA T-S 7-1/2 5/8 1-3/ DFA KC-S 1/2 3/8 5/ DFA JC-S 3/4 3/8 5/ DFA HC-S 1-1/2 3/8 5/ DFA GC-S 1-1/2 3/8 5/ DFA FC-S 2 3/8 5/ DFA EC-S 3 1/2 7/ DFA DC-S 3 1/2 7/ DFA CC-S 4 1/2 7/ DFA FC-S 5-1/2 1/2 7/ DFA EC-S 5-1/2 1/2 1-1/ DFA DC-S 7-1/2 5/8 1-1/ DTA V-S 10 5/8 1-1/ DTA T-S 12-1/2 5/8 1-3/ DFA KC-S 1/2 3/8 5/ DFA JC-S 3/4 3/8 5/ DFA HC-S 1 3/8 5/ DFA GC-S 1-1/2 3/8 5/ DFA FC-S 1-1/2 3/8 5/ DFA EC-S 2 1/2 7/ DFA DC-S 2 1/2 7/ DFA CC-S 3 1/2 7/ DFA FC-S 3 1/2 7/ DFA EC-S 4 1/2 1-1/ DFA DC-S 5-1/2 1/2 1-1/ DFA CC-S 7-1/2 1/2 1-1/ DFA V-S 5-1/2 1/2 1-1/ DFA T-S 7-1/2 5/8 1-3/ DTA P-S 10 5/8 1-3/ DTA N-S 12-1/2 7/8 1-5/ DFA HC-S 1-1/2 3/8 5/ DFA GC-S 1-1/2 3/8 5/ DFA FC-S 2 3/8 5/ DFA EC-S 3 1/2 7/ DFA DC-S 3 1/2 7/ DFA CC-S 4 1/2 7/ DFA FC-S 5-1/2 1/2 7/ DFA EC-S 5-1/2 1/2 1-1/ DFA DC-S 7-1/2 5/8 1-1/ DTA V-S 10 5/8 1-1/ DTA T-S 12-1/2 5/8 1-3/
7 Factory Installed Options DFA Indoor Unit Options Press. Controlled Fan Cycling Model DFA KC-S DFA JC-S DFA HC-S DFA GC-S DFA FC-S DFA EC-S DFA DC-S DFA CC-S DFA FC-S DFA EC-S DFA DC-S DFA KC-S DFA JC-S DFA HC-S DFA GC-S DFA FC-S DFA EC-S DFA DC-S DFA CC-S DFA FC-S DFA EC-S DFA DC-S DTA V-S DTA T-S DFA KC-S DFA JC-S DFA HC-S DFA GC-S DFA FC-S DFA EC-S DFA DC-S DFA CC-S DFA FC-S DFA EC-S DFA DC-S DFA CC-S DFA V-S DFA T-S DTA P-S DTA N-S DFA HC-S DFA GC-S DFA FC-S DFA EC-S DFA DC-S DFA CC-S DFA FC-S DFA EC-S DFA DC-S DTA V-S DTA T-S Suction Accumulator Oil Separator Dryer & Sight Glass Insulated & Heated Receiver Outdoor Hood Enclosure Model HFA Outdoor Unit Options Non-Fused Disconnect Switch Large Control Panel HFA KC-S HFA JC-S HFA HC-S HFA GC-S HFA FC-S HFA EC-S HFA DC-S HFA CC-S HFA FC-S HFA EC-S HFA DC-S HFA KC-S HFA JC-S HFA HC-S HFA GC-S HFA FC-S HFA EC-S HFA DC-S HFA CC-S HFA FC-S HFA EC-S HFA DC-S HTA V-S HTA T-S HFA KC-S HFA JC-S HFA HC-S HFA GC-S HFA FC-S HFA EC-S HFA DC-S HFA CC-S HFA FC-S HFA EC-S HFA DC-S HFA CC-S HFA V-S HFA T-S HTA P-S HTA N-S HFA HC-S HFA GC-S HFA FC-S HFA EC-S HFA DC-S HFA CC-S HFA FC-S HFA EC-S HFA DC-S HTA V-S HTA T-S Defrost Clock Press. Controlled Fan Cycling Suction Accumulator Oil Separator Dryer & Sight Glass Insulated & Heated Receiver
8 Distributed by: Bitzer Canada, Inc 870 Ellingham, Montreal, QC H9R 3S4 Tel: (514) Fax: (514) Web: Bitzer US, Inc P.O. Box Chamblee Road, Oakwood, GA Tel: (770) Fax: (770) Web:
STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request
PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer
More informationHIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationMin. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208
More informationHIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz
More informationPressure switch KP. Data sheet
Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.
More informationSealed Enclosure Cooling Air Conditioners
SPECTRACOOL Compact Indoor INDUSTRY STANDARDS UL/cUL Listed; Type 12; File No. SA6453 for N17 UL/cUL Listed; Type 12, 3R, 4, 4X optional; File No. SA6453 and UR/cUR Recognized on select models for N16
More informationH-MSTB March Replaces H-MSTB, Nov M Series. AIR-COOLED CONDENSING UNITS 1/2-6 HP Indoor and Outdoor Models. Technical Guide MOH MOZ MOS
H-MSTB March 2014 Replaces H-MSTB, Nov 2012 M Series AIR-COOLED CONDENSING UNITS 1/2-6 HP Indoor and Outdoor s Technical Guide MOH MOZ MOS Table of Contents 1/2 To 6 HP Indoor & Outdoor Condensing Units
More informationHomeWorks Remote Power Feed-Through Panels
power feed-through panels are available in two different sizes, each of which may be either surface-mounted or recess-mounted, in an electrical closet or other equipment room. The number of remote power
More informationPressure switch KP. Data sheet
Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.
More informationWO P-NF-L-M-407c Spec Submittal
WO2-2-10000-2P-NF-L-M-407c Spec Submittal General Specifications WO2-2-10000(801304) Width: IN/CM 136.25/346.07 Height: IN/CM 84.5/214.63 Depth: IN/CM 41.7/105.92 Dry weight: LB/KG 4000/1814.37 Operational
More informationS66 Series Electronic Fan Speed Control
FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,
More informationMotivair MLC-SC Air-Cooled Scroll Chillers Tons
INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced
More informationECON-ZIP-BASE. ZIP Economizer Base Module
ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and
More informationSplit System Cooling Product & Performance Data
SS-PRC014-EN Split System Cooling Product & Performance Data 2TTA0030-072A 2½ 6 Tons PUB. NO. 22-1740-01-0702 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA0 split systems
More informationKLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION
PRODUCT DATA & INSTALLATION Bulletin K30-KLP-PDI-16 Part # 1087150 PRODUCT SUPPORT web: k-rp.com/klp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KLP Low Profile Evaporators Air, Electric, Hot
More informationJ&M Fluidics, Inc. Company Product Overview
It s All about Building a Better Product for Our Clients! J&M Fluidics, Inc. Company Product Overview J&M Fluidics, Manufacturer of Air & Water-Cooled Process Chillers. Located in Telford, Pennsylvania
More informationVariable Speed DC Compressors
Variable Speed DC s Variable Speed DC s Tecumseh offers a wide range of Masterflux DC powered variable speed compressors for a variety of applications. If you have a need for compact, high power, efficient,
More informationModels: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA182, WA242 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists
More informationAquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors
Aquaflair Air-cooled chillers and free-cooling chillers with double screw compressors BREC & BREF 350-1200kW 380V/3ph/60Hz - 460V/3ph/60Hz The all-in-one solution for your business need Combining cutting-edge
More informationMCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationSplit System Cooling Product & Performance Data
SS-PRC009-EN Split System Cooling Product & Performance Data 2TTA2030-060A 2½ 5 Tons PUB. NO. 22-1735-01-0302 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA2 split systems
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationVoltage Current Front-mounting bracket
Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction
More informationVariable Speed DC Compressors and Condensing Units
Variable Speed DC s and Condensing Units 1 Variable Speed DC s and Condensing Units Tecumseh offers a wide range of Masterflux DC powered variable speed compressors and condensing units for a variety of
More information7. PCB AND FUNCTIONS
Contents. PCB AND FUNCTIS. Outdoor Unit Control PCB... - -. Outdoor Unit Control PCB CR-C0DXH... - -. Outdoor Unit FAN PCB FAN-C00DXH... - -. Outdoor Unit FAN PCB FAN-C0DXH... - -. Outdoor Unit Filer PCB
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationPressure switch Type KP
MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch Type KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high
More informationProduct Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS
Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide
More informationPressure switch KP. Data sheet
Data sheet Pressure switch KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high discharge. KP switches are also
More informationThermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.
Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or
More informationWALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA181, WA241 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists
More informationAIR COOLED CONDENSERS
AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)
More informationPressure controls, Type KP
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls, Type KP KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction
More information1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal
More informationProduct Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS
Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) the environmentally sound refrigerant Carrier s heat pumps with Puronr refrigerant provide a collection of features
More informationWiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q
AQUASNAP 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK Controls 60 Hz Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label
More informationWarning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M
INSTALLATION INSTRUCTIONS PECCSUN672 Series Power Exhaust for York - 6 Ton Units Before Starting Installation Warning Severe injury can result from incorrect servicing. Only qualified HVAC service personnel
More informationELIMINATOR Hermetic burn-out filter drier Type DAS
Data sheet ELIMINATOR Hermetic burn-out filter drier DAS ELIMINATOR Hermetic burn-out filter driers type DAS are used in the suction line to clean up refrigeration and air conditioning systems after a
More informationVC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide
Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index
More informationMcQuay. Aircon Air-Cooled Condenser. APD Vintage C. Last Manufactured: Replacement Parts List No Revision A 05/2016
Replacement Parts List No. 046902400 Revision A 05/2016 McQuay Aircon Air-Cooled Condenser APD 005-140 Vintage C Last Manufactured: 1998 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationProduct Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound
24VNA9 Infinityr 19VS Variable Air Conditioner with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably small
More information14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION
E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210565 December 2010 Supersedes November 2010 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000
More informationProduct Data. 25HNA6 Infinityt 16 Series Heat Pump with Puronr Refrigerant Sizes 24 to 60 2To5NominalTons INDUSTRY LEADING FEATURES / BENEFITS
Infinityt 16 Series Heat Pump with Puronr Refrigerant Sizes 24 to 60 2To5NominalTons the environmentally sound refrigerant Carrier s heat pumps with Puron r refrigerant provide a collection of features
More informationWiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number
30GXN,R Sizes 080-528 Air-Cooled Chillers with ComfortLink Controls 50/60 Hz Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number Label Diagram No. 30GX 080-178* ALL 1 505429
More informationMLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers
INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough
More informationOutput Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W
Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the
More informationREFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255
REFRIGERATION AND AIR CONDITIONING On Site Guide AK2-SC 255 How to Use This Guide Read this Guide completely as you install and start up your new AK2-SC 255 controller. The guide will give you thorough
More informationVariable Speed DC Compressors and Condensing Units
Variable Speed DC s and Condensing Units 1 Variable Speed DC s and Condensing Units Tecumseh offers a wide range of Masterflux DC powered variable speed compressors and condensing units for a variety of
More informationCOMFORT CONTROL CENTER SERVICE INSTRUCTIONS
USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center
More informationChiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw
Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote
More informationPrecision Cooling Mission Critical Air Handling Units
M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly
More informationSwitching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W
Switching Power Supply Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Models range from 10 to 600 W UL 508 approval on 100-W 150-W, 300-W, and 600-W models Wide range of output
More informationG3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE
Solid State Relay G3NE Compact, Low-cost, SSR Switching 5to20A D Wide load voltage range: 75 to 264 VAC. D Dedicated, compact aluminum PCB and power elements used. D Built-in varistor effectively absorbs
More informationProduct Data. SYNERGY TDA (60 Hz) Two-Speed Electric Air Conditioner. Sizes 036, 048, and 060 FEATURES/BENEFITS
Product Data SYNERGY 2000 38 TDA (60 Hz) Two-Speed Electric Air Conditioner Sizes 036, 048, and 060 Model 38TDA Air Conditioners incorporate innovative 2-speed compressor technology to provide quiet, efficient
More informationSeries P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)
PSC 0108 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression
More information14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION
E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210475 October 2009 Supersedes March 2009 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000
More informationU-Match Series DC Inverter Service Manual PRODUCT
PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More informationSlim duct (AMTTTFNLDEH ) Indoor units
Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,
More informationIT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw
IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE
More informationInstallation Instructions
50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P
More informationSystem User Manual. AKC 55 Rack Controller
System User Manual AKC 55 Rack Controller This User s Manual contains installation, start-up, and operating instructions for all parts of the Danfoss AKCESS System. Use the Table of Contents to find the
More informationASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons
Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions... Airflow Data...6 Heat Kit Data... Wiring
More informationChilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers
Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens
More informationUser s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)
More informationP216 Series Condenser Fan Speed Controller
P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version
More informationSmart Equipment Controls (SEC)
Smart Equipment Controls (SEC) Product Bulletin SE-SPU1001-0, SE-SPU1002-0, SE-SPU1011-0, SE-SPU1011-0, SE-SPU1012-0, SE-SPU1004-0, SE-FDD1001-0, SE-ECO1001-0, SE-COM1001-0 Code No. LIT-12011934 Issued
More informationGP SERIES Packaged Chillers
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from
More informationOverview of types. Technical data
echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control
More informationCPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A
CPH Series 7½- to 12½-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Heat Pump with R-410A Standard
More informationINSTRUCTIONS. KP R9748 KP 61, 62, 63, 68, 69 vapor charge KP 71, 73, 75, 77, 79, 81 adsorption charge (cross ambient)
INSTRUCTIONS KP 61 81 060R9748 KP 61, 62, 63, 68, 69 vapor charge KP 71, 73, 75, 77, 79, 81 adsorption charge (cross ambient) 060R9748 Types Bulb types Auto reset Manual reset Auto reset (w/o hand knob)
More informationFCU (FREE COOLING UNIT)
FCU (FREE COOLING UNIT) FCU reduces the AC running hours on the telecom site Controller Features: Can control upto two AC and one free cooling unit Temperature control Humidity sensor Structural Features:
More informationRS-FS-N01 Wind speed transmitter user's Guide (485type)
RS-FS-N01 Wind speed transmitter user's Guide (485type) Issue: V1.0 1 2 Context 1. Introduction... 4 2. Installation instructions...5 3. Configure the software installation and use... 6 4. Communication
More informationCONDENSING UNITS UASL- JEC
FORM NO. A22-196 3 Supersedes Form No. A22-196 Rev. 2 CONDENSING UNITS Equipped with Comfort Control 2 System Serial communication enabled Increased system reliability and efficiency 32+ on-board diagnostic
More informationDCC Commercial. Submittal Data Form Tons Packaged Air Conditioners
DCC Commercial Submittal Data Form 15-25 Tons Packaged Air Conditioners 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h Job Name
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationFree Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit
Document No. 155-324 Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Description Features Application Product Number Room temperature controller for four-pipe fan coil units.
More informationProduct Data. SYNERGY YDA (60 Hz) Two-Speed Electric Heat Pump. Sizes 036, 048, and 060 FEATURES/BENEFITS
Product Data SYNERGY 2000 38YDA (60 Hz) Two-Speed Electric Heat Pump Sizes 036, 048, and 060 Model 38YDA Heat Pumps incorporate innovative 2-speed compressor technology to provide quiet, efficient summer
More informationService Manual No-Frost Combi-Refrigerator
Service Manual No-Frost Combi-Refrigerator Models: ERF-366MNL / ERF-396MNL ERF-386MNL / ERF-416MNL DAEWOO ELECTRONICS MANUFACTURING ESPAÑA, S.A. . CONTENTS 1. SPECIFICATIONS 2. EXTERNAL DRAWINGS 3. REAL
More informationHIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER
HVH8 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUP WITH OBSERVER COUNICATING CONTROL SYSTE 2 THRU 5 TONS SPLIT SYSTE 208 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Variable
More informationYour Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant
Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,
More informationPower Electronics. Semiconductor relay / - contactor
Power Electronics Semiconductor relay / - contactor PH 9260 POWERSWITCH 0247349 Semiconductor relay PH 9260.91 Semiconductor contactor PH 9260.91/000/01 AC semiconductor relay / -contactor According to
More informationCI-tronic Reversing contactor Type RCI
Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast
More informationSeries P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue August 2016 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
More informationIndustrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air
More informationControl different load types with one device
Multipurpose Controllers DMC2 Multipurpose Modular Controller Control different load types with one device The Philips Dynalite DMC2 provides multichannel control via two interchangeable output modules.
More informationIndustrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air
More informationA Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System
A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationINSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps
INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST Model EIFM-5C For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since
More informationBlue e+ chillers with the principle
Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide
More informationElectrically operated expansion valves, type ETS REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Electrically operated expansion valves, type ETS REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationSTR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions
STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA
More informationProduct Data. Reliability
Infinityt19 2 --- Stage Heat Pump with Puronr Refrigerant 3to5NominalTons Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.
More informationDCG Commercial. Submittal Data Form
DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons
More informationRheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control 2. System. RASL- JEC Series
16.0 Air Air Conditioners Rheem Prestige Series Two- Air Conditioners equipped with the Comfort Control 2 System Efficiencies up to 18 /14 Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Cooling Capacities
More informationHigh Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)
High Voltage Induction Motors -MII Series New High Efficiency Design for High Capacity Applications Up to,0 kw (,0 HP) MII Series: Combining over 00 years of experience with innovative new technology makes
More informationModel volt to 24 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2
Model 91-30 12 volt to 24 volt DC to DC Converter Table of Contents Introduction. 2 Specifications.. 2 Operation..... 2 Installation Recommendations...... 2 Dimensions and Torque Specification. 3 91-30
More informationVRF. Technical Data Book. DVM S Eco 8, 9 HP
VRF Technical Data Book DVM S Eco 8, 9 HP Version Modification Date Remark Ver.1.0 Released DVM S Eco 8,9HP TDB.06.26 Ver.1.1 Max pipe length modified(equivalent length) : 0 -> 130m 15.04.07 Nomenclature