Owner s Manual Revision 4.01 Option 1

Similar documents
Hardware definition of comm system:

Automatic start of a generator

System Display and Controller

METERING/DISPLAY MANUAL

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Generac/Guardian Residential Standby Generators

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

Version 3.00 User s Guide

New Products. MidNite Solar Inc.

THOR Battery Backed DC Power Supply Reference Manual

INSTRUCTION MANUAL A START-UP AND SHUT DOWN LOAD SEQUENCER AND AUTOMATIC LOAD SHEDDING SYSTEM WITH INTEGRAL RELAYS FOR 8 LOADS MODEL #091-60A

FX AND VFX SERIES INVERTER/CHARGER Programing Manual

SERVICE BULLETIN DEPARTMENT OF COMPLIANCE VEHICLE SAFETY AND RECALL MANAGEMENT BUILDING N MAIN ST MIDDLEBURY, INDIANA

TT /12b INSTALLATION INSTRUCTIONS. Introduction

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

SilverLeaf RV-C Control System Training Manual

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

Setup Instructions. This manual is only valid for A12B Chargers equipped with the following: S2A-225C card with software version P225C0630

MasterBus Combi Interface

DEEP SEA ELECTRONICS PLC

Please take serious note of the following warnings:

Installation & Operation and Maintenance

Arrakis Systems 6604 Powell Street / Loveland, Colorado 80538

Spec Sheet: Zenith ZXS (ZTX) Transfer switch

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Division Services. Model: DPAS-300. Division Portable Bulk Load Accumulator Scale INDUSTRIAL PH (901) FAX (901)

Model P4470 Save A Watt Operation Manual

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Voltage Sag Simulator

Using the AUX Port on the Conext XW+ to Connect to a Generator or the Grid

INSTALLATION MANUAL SLI 50 INVERTER

Isolation Verification Control Mining - Marine - Transit Solutions LIVE Distributed By Locksafe Industrial Safety Equipment

Technical Note: XW/Conext XW+

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

WT1800 PRECISION POWER ANALYZER

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

Premium Online Series

Multi-Function Ground Resistance Tester Model 6471

Product Specifications

Total Coach System. for Foretravel Users Manual. SilverLeaf Electronics, Inc Ferry St SW Albany, OR (888)

Innovative Circuit Technology Ltd.

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

Modbus Map: Automatic Generator Start (AGS) Device

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

REMOTE METER. Model: MT50 INSTRUCTION MANUAL

Surge Guard Don t Plug In Without It! Bumper to Bumper. Power Protection

Innovative Electronics for a Changing World INDEX

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Innovative Circuit Technology Ltd.

Programming Victron MultiPlus 12V 2000Watt Inverter/Charger. (Must program with a 12V battery)

DC3IOB Revision User Guide Updated 3/29/10. Overview

SURGE GUARD * RV POWER PROTECTION. Protect What You Value Most

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

Plasmatronics 9/07/2009 Plasmatronics_Brief.product.summary_Ver.1.4.doc Slide 1

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

IPS INTELLIGENT PUMP STARTER

Conext ComBox - Custom Data Logging

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution

Lux Intelligent Emergency Light Testing System. Lx Features

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

P4472 Save A Watt HD Operation Manual

Variable Frequency Drive Design Guidelines

Infinisolar V Hybrid-On Grid Inverter with Energy Storage

TIME DELAY RELAYS Product Summary

Energy Management System. Operation and Installation Manual

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Relay Configuration Form * Required

EVERSAN. MODEL 9658 EVERSAN PERIOD INDOOR/OUTDOOR MULTI-FUNCTION SCOREBOARD. Instruction Manual

Model HM-535 Power Supply Installation and Service Instructions

Integrated Battery Control System LBCS Step-by-Step Setup Guide

VBT-75 S2 VACUUM BOTTLE TESTER

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

100% electricity. Automatic transfer switch controllers ATL series

SMART SHOT CONTROLLER FLUID USERS GUIDE

User Guide. TP3016M Series Switching Mode DC Power Supply

INDEX. Network Power Monitor R10 SNMP

PSC-10A Programmable Smart Charger. User's Guide

CORD-XL Dual-Channel Electronic Chart Recorder User s Manual

TC100 Precision Thermocouple Calibrator

MAXIMA + Series ROTARY LEVEL CONTROL

Installation Instructions & Users Manual

DC3IOB Revision User Guide Updated 7/12/12. Overview

PS-5030 (5A) OPERATION MANUAL

MC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA

Xpander Desktop Elite Gen 3 User Guide

GE Zenith ZDEC Modular Paralleling Switchgear

GE Power Management. MMII Intelligent MCC Controller

VS Technical Guide Hayward Pool Products. Version 1 Display Rev: 1.01 Comm Rev: 0.96 Drive Rev: 2.00.oz

FLEXmax 100 with ICS Plus

QCPort Cover Control Trouble Shooting Guide

Expandable Power Systems

ADDENDUM FOR 20, 27, & 28 OPTIONS

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

Transcription:

Owner s Manual Revision 4.01 Option 1 Special Version of the SW series Inverter / Charger for Motor Coach Applications Part # 2031-7 (Supplement to Normal Manual) Effective Date: April 17, 1996 Trace Engineering Company, Inc. 5916-195th Street N.E. Arlington, WA 98223 TEL (360) 435-8826 FAX (360) 435-2229

Trace Engineering SW Series Inverter/Charger - REV 4.01 Option 1-4/22/96 - Page 2 Motor Coach Software (Revision 4.01 Option 1) Notes on Changes The Motor Coach software for the Trace Engineering SW series Inverter/Charger has been specifically developed to meet the operational requirements of vehicle applications. The new software includes several changes to the inverter/charger s basic operation in addition to changes to the default settings. The Motor Coach version is an option for the new Revision 4.01 software, introduced in April of 1996 on all of the SW series. It is available in 12 VDC and 24 VDC versions. The changes can be divided into two groups - changes to the basic operation and changes to the default settings. Both groups should be examined together with the changes made in the new Rev. 4.01 software compared to the previous Rev. 3.0 software. Some additional user programming of the inverter and charger settings may be required for your application. Important Revision 4.01 Changes The new Rev 4.01 software includes many improvements and new abilities. The most substantial changes for Motor Coach applications are summarized here. A copy of the new Revision 4.01 manual should be reviewed for more information on these and other changes. Menu System - The new Rev 4.01 software divides the menu system into two parts - a USER menu and a SETUP menu. This simplifies the menu system for the system user and reduces problems with accidental changes to the inverter/charger settings. Generator Start System - The new Rev 4.01 software now includes two different start routines. The system itself has been made more fault tolerant and has additional error indications. Control Panel Operation - The red and green buttons now also are able to select the desired setting from the menu item displayed. The action of the buttons has been improved. The reset to factory default button now can be used to reset the display. This button now only resets the default settings from a specific menu item location. Important Operational Changes for the Motor Coach Version The Motor Coach version includes several changes in the basic operation of the inverter from the standard operation of the Rev 3.0 and Rev 4.01 software previously shipped. AC2 Priority - The AC2 input (generator) is now the priority. If the AC1 (grid) is energized from the shore cord being plugged in, then it will be disconnected when the generator is started. The transfer from shore cord to generator may take 8 seconds or more. (The terminal block on the inverter still lists AC1 as the priority - the change was made in the software only for the Motor Coach version.) No Cool Down - The Rev 4.01 software includes a cool-down period for the generator after it was operated. This is not included in the Motor Coach software.

Trace Engineering SW Series Inverter/Charger - REV 4.01 Option 1-4/22/96 - Page 3 Important Default Setting Changes for the Motor Coach Version The Motor Coach version includes several changes to the default setting of the Rev 4.01 software. Any unnecessary menu headings have also been eliminated to reduce the complexity of the menu system. Shore Cord Size - A new menu item, SET SHORE CORD AMPS AC, has been included in the USER menu under the SET INVERTER (1) menu heading to allow adjustment of the SET GRID (AC1) AMPS AC menu item in the SETUP menu. This makes it easier for the user to change the setting based on the hook-up capacity. It should be set to match the shore cord being used by the coach user when connecting the coach to utility power. Battery Charging - The software is programmed to have the default settings be appropriate with sealed gel cell or AGM type batteries. The equalization system has been defeated. Generator Starting - The software defaults to a new generator start routine designed for use with Onan and many diesel generators. See the Rev 4.01 manual for more information. The warm-up period for the generator has been reduced to 16 seconds. The exercising system has been disabled. Low Battery Cut Out - The default settings have been changed to allow greater use of the batteries. The LBCO setting is now also used by the generator start system to signal the generator to start if the battery reaches the LBCO setting for 30 seconds continuously. Identification and Compatibility The Motor Coach version can be identified by checking for the REVISION 4.01 OPTION 1 menu item display under the TRACE ENGINEERING (3) menu heading. This assures that the inverter includes the new software. The Motor Coach software is compatible with all SW series inverter/chargers built by Trace Engineering. The software must be configured for the DC input and AC output voltage involved before the chips are programmed. To change the software, the cover of the inverter must be removed and the top needs good access. This may require removal of the inverter/charger from the vehicle. Series II Inverter/Chargers The Motor Coach version also includes changes to the inverter/charger itself. All currently manufactured units now include: Series II Chassis - A new chassis is being used on all SW series inverter/chargers. It features improved AC wiring access and a easier to remove cover for upgrading software. High Visibility Display - The LCD display now is backlit and has greater visibility from the sides and below. Larger AC Input Contactors - The relays which connect the generator or utility grid ac sources to the inverter have been changed to a larger, heavier duty relay. This change has eliminated the problem with stuck relays previously encountered. AC Input Provisions and Ground Bonding Neither the Motor Coach version or the standard version of the SW series inverter/charger includes ground switching or bonding. This must be added externally to the inverter/charger. DO T CONNECT BOTH THE GENERATOR AND THE UTILITY GRID TO THE SAME AC INPUT TERMINALS - THIS IS T ACCEPTABLE A WILL VOID THE WARRANTY IF FOUND. The SW series includes two AC inputs - each must be used as intended.

Trace Engineering SW Series Inverter/Charger - User Menu - REV 4.01 Option 1-4/22/96 - Page U1 ON /OFF MENU Set Inverter OFF SRCH ON CHG GEN MENU Set Generator OFF AUTO ON EQ This button provides direct access to the SET INVERTER menu item from anywhere in the user menu. Pressing this red button again selects the next setting to the right, as indicated by the position of the cursor under the first letter. You can also use the SET POINT buttons to move the cursor right or left. This button provides direct access to the SET GENERATOR menu item from anywhere in the user menu. Pressing this green button again selects the next setting to the right, as indicated by the position of the cursor under the first letter. You can also use the SET POINT buttons to move the cursor right or left. MENU HEADINGS Inverter Mode 1 Set Inverter OFF SRCH ON CHG Set Shore Cord Size Amps AC 50 CHG avail. Only in FLT mode. Press red or setpoint button to move cursor. Move cursor to Inverter OFF to resetovercurrent MENU ITEMS 2 Set Generator OFF AUTO ON EQ Gen under/over speed Generator start Generator sync Gen max run time Load Amp Start Voltage Start Exercise Start Move cursor to GEN OFF to reset generator error. If no start in 5 trys then error. If Gen starts & runs for 5 min then stops the inverter will not attempt restart until Gen auto start conditions are again satisfied. If Gen runs for more than max run time then error. Trace Engineering 3 Press reset now for defaults Revision 4.01 Option 1 5916 195th St NE Arlington, WA 98223 USA Ph 360-435-8826 Fax 360-435-2229 Meters 4 Inverter/charger Input Load Battery actual volts DC 25.2 Battery TempComp volts DC 25.2 Inverter Grid (AC1) Generator (AC2) Read Frequency Hertz 60 AC1 & AC2 volts valid only when inverter synced to that input. Batt volt actual is used for LBCO,HBCO,LBX, LBCI,sell volts and gen starting Batt volt temp comp is used for float,bulk,eq & aux relays Error Causes Over Current Transformer overtemp Heatsink overtemp High Battery voltage Low Battery voltage 5 AC source wired to output External error (stacked) Generator start Generator sync Gen max run time Gen under/over speed Inverter breaker tripped Menu Heading Time of Day 00:00:00 6 Set Clock hour 00:00:00 Set Clock minute 00:00:00 Set Clock second 00 Menu Item Setpoint Information Generator Timer 7 Start Quiet End Quiet Gen doesn t run during quiet time unless batt volts is less than LBCO volts for 30 seconds To defeat timers set start = end. If exercise days set to 1 then gen will always start @ endquiet END USER MENU Values shown are defaults for 24 vdc 120 vac / 60 Hz models 8 Under/Over speed will cause a sync error in 10 minutes. REVMCUS..DOC Generator Mode

Trace Engineering SW Series Inverter/Charger - Setup Menu - REV 4.01 Option 1-4/17/96 - Page S1 To access the Setup Menu, press the RED and GREEN buttons at the same time. To exit the Setup Menu, press the red ON/OFF MENU button or use the down MENU HEADING button until you reach the User Menu (menu headings 1-8). MENU HEADINGS Inverter Setup 9 Battery Charging 10 AC Inputs 11 Gen Auto Start setup 12 Gen starting details 13 Auxiliary Relays R9 R10 R11 14 Set Low battery cut out VDC 20.0 Set LBCO delay minutes 5 Set Low battery cut in VDC 23.0 Set High battery cut out VDC 30.0 Set search watts 48 Set search spacing 59 Set Bulk volts DC 28.4 Set Absorption time h:m 02:00 Set Float volts DC 27.6 Set Equalize volts DC 28.4 Set Equalize time h:m 00:10 Set Max Charge amps AC 15 Set Grid (AC1) amps AC 50 Set Gen (AC2) amps AC 30 Set Input lower limit VAC 105 Set Input upper limit VAC 132 Set Load Start amp AC 33 Set Load Start delay min 5.0 Set Load Stop delay min 5.0 Set 24 hr start volts DC 24.6 Set 2 hr start volts DC 23.6 Set 15 min start volts DC 22.6 Set RY7 Function GlowStop Run Set Gen warmup seconds 16 Set Pre Crank seconds 10 Set Max Cranking seconds 10 Set Post Crank seconds 30 Set Relay 9 volts DC 29.0 R9 Hysteresis Set Relay 10 volts DC 29.5 R10 Hysteresis Set Relay 11 volts DC 30.0 R11 Hysteresis Set Temp Comp LeadAcid NiCad Read LBCO 30 sec start VDC 20.0 Set Exercise period days 00 Set Maximum run Set Max Run time to 0 to defeat close on batt >setpoint open on batt <setpoint - Hys relays have 2 second delay on close, 0.1 sec delay on open Set Exercise to 0 to defeat Menu Heading Menu Item Setpoint Information Values shown are defaults for 24 vdc 120 vac 60 Hz models MENU ITEMS REVMCSU.DOC