Huba Control. Pressure, vacuum and differential pressure transmitter. 0 3 / 5 / 10 / 30 / 50 mbar EDITION 12/2005

Similar documents
Relative and differential pressure transmitter type 652

Relative, and differential pressure transmitter type 699

Pressure range mbar / mbar

Pressure Transmitter type 548 with display and programmable switching outputs

Relative and absolute pressure transmitter type 528

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

Datasheet DE DB_EN_DE45_LCD Rev. ST4-G 11/17. Digital differential pressure switch / transmitter with colour-change LCD * *

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM3TI4 module TM3-4 inputs temperature

TM3AI4 module TM3-4 analog inputs

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

TM3DI16 module TM3-16 inputs

EM2020 Selectable AC transducer A (UK)

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

TM3TI8T module TM3-8 inputs temperature

Output Voltage* (nom.)(adjustable)

MINI MCR-SL-UI-REL(-SP)

NOVOHALL Transducer 5 up to 50 mm touchless. Series TFD-4000

TM3TI4 module TM3-4 inputs temperature

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

Multi-range pressure and differential pressure transmitter

DI561 Digital Input Module

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Power Supply HARTING pcon

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

NOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental

NOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Power Supply HARTING pcon

RMCN22BD Analog Converter ma - for Zelio Analog

Differential Pressure Controller DPC 200

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

MINI-PS AC/10-15DC/8

Electronic timer CT-ERD.12

TM3DI16G module TM3-16 inputs spring

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

TU531, TU532 Terminal Unit

Output Voltage* (nom.)(adjustable)

DC562, digital input/output module,

AI561 Analog Input Module

Time Counters mini "h", DC Version

DI572 Digital Input Module

HD B. [ GB ] Precision Barometer

Vert-X 05E 5V / % Ub. Application Access control systems Forklift

DC561, digital input/output module,

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Flow sensors SFAB Key features

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

Electronic timer CT-AHD.22

Voltage Current Front-mounting bracket

TF501, TF521 Terminal Bases

AO523 Analog Input Module

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Contact protection relay

DX561 Digital Input/Output Module

Installation Instructions Temperature transmitter TAA /00 06/2011

TM3DI8A module TM3-8 inputs 120V AC

Standard-Signal Isolation Amplifiers. VariTrans A 21000

Immersion Temperature Sensors

RTU500 series Data Sheet Power Supply CP-E 24/2.5

LED Driver Linear / area fixed output

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

TRIO-DIODE/12-24DC/2X10/1X20

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

DC541 Digital Input/Output Module

Power supply CP-D 12/2.1 Primary switch mode power supply

LED Driver Linear / area fixed output

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

Industrial Power Supplies

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

MINI MCR-SL-UI-2I(-SP)(-NC)

LED Driver Linear / area fixed output

Air gap sensors SOPA

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

AO561 Analog Output Module

PHOENIX CONTACT - 07/2006

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

U7100 Pressure Transducer

AI531 Analog Input Module

LED Driver Linear / area fixed output

Three-phase monitoring relay

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

Item No.: /

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

M7100 Pressure Transducer

Vert-X 32E - 24V / CANopen, redundant. Applications Forklifter Platformer Agricultural machine. Features. CiA approved CiA V402/

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

MID approval no. DE-08-MI004-PTB004 Date of release

CD522 Encoder, Counter and PWM Module

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

Transcription:

402 Pressure, vacuum and differential pressure transmitter 0 3 / 5 / 10 / 30 / 50 mbar EDITION 12/2005 Huba Control FOR FINE PRESSURE AND FLOW MEASUREMENT

Technical overview The differential pressure transmitters of type 402 with their proven ceramic fulcrum lever technology have calibrated, temperature-compensated sensor signals that are available with voltage outputs. They are ideally suited for registering fine air flow in air conditioning technology and for measuring fine pressures in the environmental / medical technology sectors. Medium Air, neutral gases Pressure ranges Pressure ranges see order code selection table, other pressure ranges on request. Tolerable overload Installation arrangement Diaphragm vertical, pressure connections facing downward, diaphragm horizontal, P1 upwards Adjusting position see order code selection table Power supply / Qutput 100 mbar Power supply Output 12 V (10.2 33.0 VDC) 0.5 4.5 VDC Print version Rupture pressure 200 mbar at room temperature 150 mbar at 70 C Load > 15 kohm (to GND) Case construction Polycarbonate PC / Polyamide PA Protection standard IP 00 Diaphragm Silicone Current consumption max. 8 ma Legend to cross-section drawing 1 Electrical connection 2 Ceramic fulcrum lever with electronic circuitry 3 Diaphragm 4 Connection port P1 higher pressure/lower vacuum 5 Connection port P2 lower pressure /higher vacuum The distinct advantages Attractive price / performance ratio Excellent synergy of diaphragm technology and ceramic elements Accuracy Medium and ambient temperature 0 70 C TC sensitivity and TC zero point see parameter table Storage temperature 30 + 70 C Dynamic response Suitable for static and dynamic measurements. Response time: Load cycle: Weight approx. 28 g < 10 ms < 10 Hz Electrical connections Solderable pin on circuit board 3-pole plug connector RAST 2.5 mm (AMP / Lumberg / Stocko) Adapter plate Phase-reversal protection: Connector and pcb version protected mechanically. Packaging In cartons with blister inserts, returnable See order code selection table (supplied loose with consignment) Special adapter for top-hat rail mounting Direct pcb mounting with simple snap-on system

E Versions A Connector version B Print version (for soldering customer sides) A B Accuracy Transmitter-Type Parameter Unit 0 3 mbar 0 5 mbar 0 10 mbar 0 30 mbar 0 50 mbar Zero point 1) (at 0.5 V) V +/- 0.025 +/- 0.025 +/- 0.025 +/- 0.025 +/- 0.025 Final value 1) (at 4.5 V) V +/- 0.050 +/- 0.050 +/- 0.050 +/- 0.025 +/- 0.025 Linearity typ. % fs +/- 0.3 +/- 0.3 +/- 0.2 +/- 0.2 +/- 0.2 Linearity max. % fs +/- 0.5 +/- 0.5 +/- 0.3 +/- 0.3 +/- 0.3 Hysteresis typ. % fs 0.2 0.2 0.2 0.1 0.1 Hysteresis max. % fs 0.5 0.4 0.3 0.2 0.2 Long-term stability 2) % fs +/- 1.0 +/- 1.0 +/- 1.0 +/- 1.0 +/- 1.0 TC zero point 3) typ. % fs/k +/- 0.02 +/- 0.02 +/ 0.02 +/- 0.02 +/- 0.02 TC zero point 3) max. % fs/k +/- 0.04 +/- 0.04 +/- 0.04 +/- 0.04 +/- 0.04 TC sensitivity 3) typ. % fs/k +/- 0.03 +/- 0.03 +/- 0.02 +/- 0.02 +/- 0.02 TC sensitivity 3) max. % fs/k +/- 0.06 +/- 0.05 +/- 0.04 +/- 0.04 +/- 0.04 Positional error 1) mbar approx. -0.13 approx. -0.13 approx. -0.13 approx. -0.13 approx.-0.13 Test conditions: 25 C, 45 % RH TC z. p. / TC s. 0 70 C Order code selection table 402. 9 X X X X X X Pressure ranges 1 0 + 3 mbar 1 0 + 5 mbar 2 0 + 10 mbar 3 0 + 30 mbar 4 0 + 50 mbar 5 Adjusting position Diaphragm vertical, pressure connections downwards 0 Diaphragm horizontal, P1 upwards 1 Diaphragm Silicone 0 Output and power supply 0.5 4.5 V 12 VDC (10.2 33 VDC) 0 Electrical connections Print version 1 Connector version (RAST 2.5 mm) 2 For direct pcb mounting, mounted and soldered on adapter plate (compatible for types 696/697) 3 Pressure connection Pipe Ø 6.2 1 Fixing screw for wall thickness Length of screw 1 2 mm 6 mm 1 0 2 9 7 6 4.1 6 mm 10 mm 1 0 2 9 7 8 AMP Connector with cable (110 cm) 1 0 1 8 1 7 Base plate for rail mounting suitable for bearing rail TS 35 1 1 0 6 5 6 Bracket 1 0 8 2 2 2 Adapter (compatible for types 696/697) 1 1 0 9 1 0 Connecting cable for connector version (compatible for types 696/697) 1 1 1 7 0 7 AMP Connector Manufacturer s Part No. Colour for cable 3-829868-3 grey 7-wire 0.22 0.25 mm 2 or 12-wire 0.32 0.35 mm 2 1-966194-3 beige 7-wire 0.32 0.35 mm 2 1) For changing diaphragm position from horizontal to vertical, approx. -13 Pascal 2) Long-term stability acc. to DIN IEC 770 3) TC = Temperature coefficient 4) Other pressure ranges on request 7

Dimensions in mm Electrical connections Connector version Hole pattern Fixing holes for PT fillister head screw 2.5 Print version Hole pattern Print Fixing holes for PT fillister head screw 2.5 Bracket Base plate for railmounting suitable for bearing rail TS 35 Adapter Hole pattern for direct pcb mounting with adapter Print Electromagnetic compatibility: CE conformity (EMC) by application of harmonized standards: Interference stability EN 61000-6-2, EN 61000-6-3 and EN 61326-1 Interference stability Test standard Effect Electrostatic discharge (ESD) EN 61000-4-2 8 kv air no effect High-frequency electromagnetic radiation (HF) EN 61000-4-3 10 V/m, 80 1000 Mz no effect Conducted HF interference EN 61000-4-6 10 V, 0.15... 80 MHz no effect Fast transients (burst) EN 61000-4-4 4 kv no effect Interference emit Test standard Effect Conducted interference EN 55022 (CISPR 22) 0.15... 30 MHz no emission Radiation from housing 30... 1000 MHz, 10 m no emission

Huba Control Headquarters Huba Control Schweiz Industriestrasse 17 CH-5436 Würenlos Telefon ++41 (0) 56 436 82 00 Telefax ++41 (0) 56 436 82 82 info.ch@hubacontrol.com Huba Control Deutschland Schlattgrabenstrasse 24 72141 Walddorfhäslach Telefon (07127) 23 93-00 Telefax (07127) 23 93-20 info.de@hubacontrol.com Huba Control France Technopôle Forbach-Sud 57602 Forbach-Cedex Téléphone 03 87 84 73 00 Télécopieur 03 87 84 73 01 info.fr@hubacontrol.com Huba Control Nederland Hamseweg 20A 3828 AD Hoogland Telefoon 033 433 03 66 Telefax 033 433 03 77 info.nl@hubacontrol.com Huba Control United Kingdom Unit 3 Network Point, Range Road Witney Oxfordshire OX29 0YD Tel 01993 776667 Fax 01993 776671 info.uk@hubacontrol.com www.hubacontrol.com Technical data subject to change.