Automatic Insulating In-Line Oil Tester DTA 100 E-AD

Similar documents
Data Sheet. IEC156/ MEAN VALUE 97.6 kv STD. DEV. 2.6 S/M 2.7 % TEST kv MENU START

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

BA family. Portable and laboratory based Oil Test Sets

PROFITEST Tester for DIN EN and VDE 0113

SIMOREG 6RA70 DC MASTER SIMOREG CM

LOW WEIGHT, SMALL SIZE,

PROFITEST 204 Tester for DIN EN and VDE 0113

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

LineMaster 100 Continuous-line Recorder

PROFITEST Tester for DIN EN and VDE 0113

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

PointMaster 100. Multipoint Recorder 10/ EN

Datasheet AZM 161 Z ST1 AS RA

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Service Instruction DPA 75

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions

SECUTEST S2 N+w Test Instrument with Automatic Test Sequences for IEC and Draft IEC 62638

RUC-M industrial relays for DC loads

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Operating Instructions VEGAMET 381

MID approval no. DE-08-MI004-PTB004 Date of release

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Datasheet - MZM 100 B ST-1P2PW2REM-A

Zelio Control-modular measurement and control relays 1

Electronic Temperature Controller. Instruction Manual Version

ProcessCalibrator Model CPH6000

RUC industrial relays of small dimensions

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Compact Universal Controllers

02/11/2015

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

02/11/2015

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

QUINT-PS/ 1AC/24DC/ 5

Flow. Flow. N/en

PAT-Cal 2 TECHNICAL MANUAL

Operating Instruction

JUMO Quantum PID100/PID200/PID300

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Micro Contactor MA Series

IST ULTRASTAB Power Supply for high precision transducers

PHOENIX CONTACT - 01/2007

PROFITEST 204 For testing the safety of electrical machinery equipment

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

RM699B miniature relays

UH28C. High Voltage Tester. Product Information Sheet V AC / 100 ma

Test devices and Multifunction timer relay

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Technical Specification

Magnetic and Hydraulic-Magnetic Circuit Breaker

QUINT-PS AC/24DC/10

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Assembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP

Residual overvoltage relay

FUTURA Egg-Shell-Tester V. 2.0 User Manual

Gas Controller System DGC-06

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

Miniature Circuit-Breaker IEC Series 8562

Immersion Temperature Sensors

Datasheet - AZM 200 BZ ST-T-AS P

Datasheet - RSS 36-D-R-ST

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

Digital electropneumatic Positioner for the integrated mounting on process control valves

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Earth-fault Relay SPAJ 110 C. Product Guide

Mechanical, analog system comprising sensor and processor for accurately recording the position of gripper jaws.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

PROTECTA Series IP66 weatherproof switches & sockets to safeguard home and family

Pneumatic precision pressure controller Model CPC6000

LineMaster 200. Continuous-line Recorder. ABB Instrumentation 10/ EN

Precision pressure indicator 1- or 2-channel version Model CPG2500

Pneumatic precision pressure controller Model CPC6000

RM84 / RM85 / RM87 Miniature Electromagnetic Relays

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

DOT MATRIX PRINTER SP6000 SERIES

Level measurement. Applications. Special features. Description

SWISS MADE. Series 320 XT PREMIUM. Analytical. Precision

Indicomp 4 Bargraph Indicator

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

InCos-P Pressure sensor 20 Pa Pa

Micro calibration bath Models CTB , CTB

CalibratorUnit Models CPU6000-W, CPU6000-S, CPU6000-M

Operating pressure (bar) kv factor (m 3 /h) *3)

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Old documentation - Only for your information! Product is not available anymore!

Zenith DS9000 Dispensing System

Extract from the online catalog

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

Transcription:

Automatic Insulating In-Line Oil Tester DTA 100 E-AD The DTA 100 E-AD is designed to measure the electric breakdown strength of liquid or gaseous insulants fully automatically. It is used in conjunction with a personal computer and the DTA 100 E-AD control software package from BAUR. Measurement routines are executed in accordance with the selected control program and the selected test standard. Features: Electromagnetic screening - nearby electronic appliances are not affected by any interference Lockable protective hood for maximum user safety Quick breakdown detection and current break time < 1 ms. Avoids formation of fibres or carbonation of mineral oils Selectable test voltages up to 100 kv rms Self-test after each switch-on Printer log for evaluation of measured data Test cell Hermetically sealed design resistant to pressure, vacuum and temperature for carrying out flow type oil tests (also available as a transportable cell) Adjustable electrode spacing Exact setting of electrode spacings in conformance with the standards (without touching with a check gauge) by means of a built-in vernier and electro-acoustic zero spacing control Simple rinsing of the test cell by key-operated triggering of a solenoid valve Available to order with stirrer

DTA 100 E-AD - measurement set-up: 1 DTA 100 E-AD oil tester with test cell 2 Personal computer (IBM-compatible XT, AT or higher) 3 Printer (IBM graphics) Block diagram: 1 2 3 F1 F2 F3 F4 F5 BAUR Oil Test System Version 1.0 MV2 Oil regenerating system MV1 Output regenerated oil F9 P DTA 100 E-AD Printer PC MV3 All the measurement and control functions are performed by the personal computer with the DTA 100 E-AD control software package from BAUR. This user-friendly measurement program offers the following selection of measurement functions: F1 withstand standard test F2 automatic standard test F3 single standard test F4 single test F5 options (select language, input report data, printer) F9 terminate (program exit) The required parameters (e.g. test standard, mean value pre-set, etc.) are entered in the respective submenus. A connected printer enables evaluation of the measurements and test data after completion of the measurement routine. Fully automatic control of a regenerating system In the measurement functions F1 (withstand standard test) and F2 (automatic standard test), the solenoid valves (MV1 - Fill, MV2 - Regenerate) of a regenerating system are controlled automatically during a measurement routine.

Interfaces on the DTA 100 E-AD: View of rear panel 8 3 4 7 1 2 6 5 Hydraulics 1 Oil inlet 2 Oil outlet 10 6 9 Electrics 3 2-pole socket "Overflow", input for external overflow sensor (e.g. a float switch) 4 2-pole plug "Alarm", output for external alarm signalling device (e.g. a flashing light or horn) 5 RS 232 interface for a personal computer 6 Appliance socket connector 7 10-pole plug X1 "Extern Valves" for external solenoid valves MV1 (Fill) and MV2 (Regenerate) Switching elements 8 Pushbutton "MV3 ON", for opening the solenoid valve MV3 (e.g. for rinsing the test cell) 9 Power switch "ON / OFF" 10 Solenoid valve MV3 (Fill test cell)

Technical data DTA 100 E-AD Power supply 110-120 V / 220-240 V (50 Hz - 60 Hz) Power consumption max. 200 VA Display backlit, 160 x 80 dot-matrix, LCD Voltage indication, digital 0-100; ± 1 kv Resolution (displayed) 0,1 kv Selectable languages German, English, French, Italian, Spanish, Dutch; other language on request Test cycles according to a standard 13 pre-programmed test standards are available: ASTM D 1816 / 97; ASTM D 877 / 87; BS EN 60156; CEI EN 60156; CSSR RVHP / 85; IEC 156 / 95; IRAM 2341 / 72; JIS C2101 / 78; PN 77 / ED 4408; SEV EN 60156; UNE 21 309 / 89; NF EN 60156; VDE 0370 part 5 / 96; Additional test cycles 5 free programmable test cycles Test voltage, testing insulants 0... 100 kv rms, symmetric Voltage rate of rise 0,5 kv / s / 1 kv / s / 2 kv / s / 3 kv / s / 5 kv / s Switch off current 4 ma Switch off time on breakdown 1 ms RBM (Real Breakdown Monitoring) detects insulating liquids with specific resistance too low ρ < 30 MΩm Relative humidity 90 not condensing Maximum ambient temperature Working: 0... + 45 C Dimensions (W x H x D) Weight Printer PC-Interface Designed and built acc. To the following standards Use Outputs 2 pole plug for "alarm" 10 pole plug for "external values" 2 pole socket for Overflow Storage: - 20... + 55 C 450 x 460 x 500 mm 37,6 kg Matrix printer, 24 char., 57 mm plain paper bi-directional RS 232, 9 pin sub D Optional: Windows PC Software Low voltage directive 73 / 23 / EWG, EN 61010-1 EMV directive 89 / 336 / EWG with modification 91 / 263 / EWG, 92 / 31 / EWG VDE 0843 part 2, IEC 801-2 / VDE 0843 part 4, IEC 801-4 VDE 0875 part 11, EN 55 011 for insulating liquids / gas with tan δ - values < 4,5 specific resistance ρ > 30 MΩm - potential-free (max. 1500 V AC ) switching capacity 250 V AC / DC; 1 A potential-free (max. 1500 V AC ) switching capacity 250 V AC / DC; 1 A + 12 V DC / 14 ma for switch open

Order instructions: Please specify in each enquiry or order: Automatic Insulating In-Line Oil Tester DTA 100 E-AD 415+038 Delivery includes: Automatic insulating in-line oil tester DTA 100 E-AD without accessories Test-Cell (test vessel)) Test-Cell 0.7 l according to IEC 156 fig. I; for insulating liquids, flow type Test-Cell 0.7 l according to IEC 156 fig. II; for insulating liquids; flow type Test-Cell 0.7 l according to ASTM D 877 for insulating liquids; flow type Test-Cell 0.7 l according to ASTM D 2477; for insulating gases; flow type Oil collecting tray PC control software for DTA 100 E-AD Cable with D socket 9 poles / D socket 9 poles Cable for external magnetic valves DTA 100 E-AD Filter plug RS 232 Setting gauge 2.5 mm IEC Mains connection cable Ink ribbon for plain paper printer - fed into printer Paper roll for plain paper printer, 57 mm width, Ø 30 mm, inserted in printer Operating manual Options: Transport case made of plywood Test-Cell 0.7 l according to IEC 156 fig. I; for insulating liquids, flow type Test-Cell 0.7 l according to IEC 156 fig. II; for insulating liquids; flow type Test-Cell 0.7 l according to ASTM D 877 for insulating liquids; flow type Test-Cell 0.7 l according to ASTM D 2477; for insulating gases; flow type Dust cover Setting gauge 1 mm Setting gauge 2 mm Setting gauge 4 mm Setting gauge 5 mm Calibrator KA 100, including software, connection cables, operating manual Consumer parts for plain paper printer: Ink ribbon for plain paper printer Paper roll for plain paper printer, 57 mm width, Ø 30 mm Mains supply: 110 V ~ to 120 V ~ 220 V ~ to 240 V ~... Included in standard delivery... Selectable (please mark with a cross or specify) Standard Selection