The Case for TDM Coexistence in O-Band

Similar documents
TDM vs. WDM co-existence with 10G EPON: update

Selection of 100G-EPON Wavelength Plan

100G EPON wavelength plan analysis

Towards building a low cost 25G base PHY for 100G EPON

100G-EPON Wavelength Plan solution candidates

Sensitivity definition and TDP in 802.3ca discussion

Enhancing PON capabilities using the wavelength domain

Next Generation PON: Lessons Learned from G-PON and GE-PON

Coexistence with Current Systems - 10GE-PON System Configuration. ver.1.2

NRZ-NFC for 28G-PON. Contribution to The IEEE NG-EPON Study Group Meeting, Nov , 2015

400GBase-LR8: A Proposal for 10 km Objective Using 50 Gb/s PAM4 Signaling

Unified Evolution-Ready 25/50/100 Gbps-EPON Architecture Proposal

Architecture Analysis of Hybrid TDM/WDM PON

Can You Haul Me Now? Bart Filipiak Market Development Manager 18 March 2009 Piedmont SCTE

Technical Feasibility of optical PMDs with RS FEC

100GE 10km SMF WDM Grid Alternatives

Joint ITU-T/IEEE Workshop on Next Generation Optical Access Systems. Requirements for Next Generation PON

-Access Platforms Integration- Next Generation PON System. System Platforms Research Labs, NEC Corporation. Akio Tajima. Feb.

Connect to wavelength management

More on Super-PON. Scale Fully Passive Optical Access Networks to Longer Reaches and to a Significantly Higher Number of Subscribers

Next Generation EPON Considerations of ODN, Coexistence and Transmission Speed

Passive Optical Networks: Fundamental Deployment Considerations

Introduction to Networks

Increasing Fiber Capacity with CWDM

Ethernet in the First Mile Optical Architectures and Fibers John George Lucent Technologies 3/05/2001

Performance Evaluation of the Maximum Achievable Bit Rate of a Next Generation TWDM Passive Optical Network

Past PHY naming some thoughts

STATUS OF THE ART IN OPTICAL ACCESS NETWORKS AND FORECASTED OPTOELECTRONIC COMPONENT REQUIREMENTS

100G SWDM4 MSA Technical Specifications Optical Specifications

SO-CFP-ER4-SC. CFP, 103/112 Gbps, SM, DDM, 40 km OVERVIEW PRODUCT FEATURES ORDERING INFORMATION DATASHEET 4.1

Considerations on X00 Gb/s 40-80km interfaces with appropriate support for DWDM systems. Peter Stassar HUAWEI TECHNOLOGIES CO., LTD.

40 Gbit/s Small-Form Low-Power Optical Transceiver

CFI for CFI: 1x50Gb/s and 2x50Gb/s EPON

Performance Evaluation of Qos for Multicast Streams in Optical Passive Networks

Application Note Fiber Connectivity

Bi-directional 125Mbps PMD for FTTH Application (100BASE-BX

EPOC Upstream PHY Link Channel and Channel Probing

Lecture 2 Physical Layer - Multiplexing

WDM PON: Systems and Technologies. ECOC workshop Turino, Italy, 2010

Simulation of Simultaneous All Optical Clock Extraction and Demultiplexing for OTDM Packet Signal Using a SMZ Switch

Kotura Analysis: WDM PICs improve cost over LR4

Optical Fiber Networks: Industry. and New Options for Networks

Gigabit-capable Passive Optical Networks (G-PON): Physical Media Dependent (PMD) layer specification Amendment 2

The Analysis of SARDANA HPON Networks Using the HPON Network Configurator

PON Technology Evolution Discussion

E3-E4 (CFA) EPON & GPON. For BSNL internal circulation only

Chapter 8: Multiplexing

Cisco Prisma D-PON: Your DOCSIS-Based Fiber-to-the-Home Solution

Facebook: CWDM4-OCP. 100G Optical Transceiver Specification

Fast Ethernet Simplex Transceivers for POF Inhouse LAN

IEEE 1G and 10G EPONs: Factors that Influenced the Architecture and Specification

40 Gigabit QSFP CWDM 1310 nm LR4 for 10 km

ITU-T G (06/2012) 10 Gigabit-capable passive optical networks (XG-PON): Reach extension

Design of AWG-based WDM-PON Architecture with Multicast Capability

Effects of using RZ and NRZ modulation formats for TDM-PON system on Transmission Characteristics for Downstream Signals

WDM-PON Architecture Implement Using AWG with Multicasting Efficiency

Error characteristic and test in XGPON system (Ber=1e-2)

Performance Analysis of Unidirectional and Bidirectional Broadband Passive Optical Networks

Simply self-restored ring-based time-division-multiplexed passive optical network

NG- PON2 & XGS- PON: Lowering the Cost of Consolida<ng Residen<al and Business Services

Features. 100G CFP Optical Transceiver Module RoHS 6 compliant

Fiber Optic Cabling Systems for High Performance Applications

Last modified: 28 April 2008

Wavelength-Switched to Flex-Grid Optical Networks

10G-EPON Standardization and Its Development Status

Physical Layer Part 3

DWDM Topologies CHAPTER. This chapter explains Cisco ONS dense wavelength division multiplexing (DWDM) topologies.

Pay as You Grow or Mortgage Model? - The Needs for Standalone 25G EPON

GEPON OLT Optical Module

A Novel Reconfigurable Ring Architecture of Multiple Secure Private Networks over EPON Using OCDMA Code-Drop Units

Proteus Node Return Digital Transmitter with Ethernet

Performance Analysis of 2. 5 Gbps downlink GPON

SLIDE 1 - COPYRIGHT G. Across the country, Across the Data Centre. Tim Rayner. Optical Engineer, AARNet.

REVIEW ON WDM AND TDM PON USING DIFFERENT CODING SCHEMES FOR EXTENDED REACH

Outline. Designing and measuring PON Conclusions. WDM-PON advantages & challenges AWG router transmitter sources - wavelength specific & colorless ONU

MA R K E TING R E PORT. The Future of Passive Optical Networking is Here NG-PON2

A Scalable CWDM/TDM-PON network with future-proof elastic bandwidth

Deployment & Operations Committee. FTTH Basics Architecture, Topology and Technology

Cisco Digital CFP2 Pluggable Optical Module

Analysis of Next Generation PON Architecture for Optical Broadband Access Networks

100G DWDM QSFP Datasheet

Optical Loss Budgets

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

International Standardization Activities on Optical Interfaces

Name of Course : E1-E2 CFA. Chapter 15. Topic : DWDM

Optical Communications Mainframe Optical Wavelength Division Multiplexer

GEPON OLT PX20+ Optical Module

Joint ITU-T/IEEE Workshop on Next Generation Optical Access Systems. Standards Overview of ITU-T SG15/Q2

PSM4 Technology & Relative Cost Analysis Update

Ethernet The Next Generation

Network Evolution Driving forces and influences on the physical Network

QFPQL010400D QSFP+ Dual Fibre CWDM ITU CWDM / 10km / 40 Gigabit Ethernet / LR-4

Next Generation Optical Access Networks: A Review

optical Optical & IC Selector Guide FEATURING 2017 High Performance Portfolio

Cisco Compact EGC Segmentable Node A90200

Optical Fiber Communications. Optical Networks- unit 5

Compact EGC Segmentable Node 115 V Mains Powered A90200

5GBPS CWDM-PON ARCHITECTURE FOR LONG REACH UNICAST AND MULTICAST DATA USING HYBRID AMPLIFIER

Physical Layer Part 3

Spectral testing in lab and manufacturing environments

Transcription:

The Case for TDM Coexistence in O-Band John Johnson IEEE 802.3 Interim, Huntington Beach January 10, 2017 1 01/10/2017 IEEE 802.3ca Task Force

TDM coexistence vs. WDM coexistence Given previous arguments that having all channels in O-band is the best performing and lowest cost choice for NG-EPON wavelength plan (johnson_3ca_1_0117), the remaining choice is whether to implement 10G-EPON upstream coexistence with WDM or TDM. WDM coexistence is the default choice for a new PON standard since it preserves all of the available capacity for subscribers to the new PON, but the cost of that incremental capacity must be considered. For TDM coexistence to be chosen to the exclusion of WDM coexistence, there should be significant advantages to compensate for the incremental loss of capacity inherent in TDM. In this contribution, we present arguments that TDM coexistence confers significant cost and performance advantages over WDM, and is the best choice for NG-EPON. 2 01/10/2017 IEEE 802.3ca Task Force

The case for TDM coexistence Whether TDM is sufficient for coexistence with 10G-EPON without significantly impacting 25/50/100G upstream capacity is critical to the wavelength plan decision. Harstead_3ca_2a_1116 showed that TDM coexistence has little impact on 25/50/100G upstream capacity for expected 10G service levels (<1Gb/s). TDM coexistence brings several important advantages over WDM Sharing 1270±10nm spectrum with 25G US0 channel allows wider US channel spacing and laser accuracy, resulting in lower ONU optics cost Enables the possibility of a low-cost uncooled upgrade path from 25/10G to 25/25G ONUs as upstream capacity demand grows. Enables smaller, lower cost OLT optics using a single 10/25Gb/s dual-rate RX without extra coexistence splitter loss. TDM has minor challenges, but they are outweighed by the significant advantages listed above. Demux with mix of passband width and channel spacing solvable using TFF demultiplexers. Dual-rate 10/25G burst-mode TIA is to be developed, but not considered high risk. Proprietary tri-rate 1/10/25G TDM can also be supported. Lower sensitivity of optically amplified 100G RX with 20nm passband Bonk_3ca_1_0117 predicts that this is a wash vs APD Rx if the 1270nm signal is demultiplexed with low insertion loss. 3 01/10/2017 IEEE 802.3ca Task Force

Plan A with WDM coexistence Original Plan A (johnson_3ca_1_0916) 800GHz channel spacing US and DS ±1nm laser accuracy US and DS Narrow US-DS gap for 25G ONU Marginal DS0-DS1 guardband US0 marginal to 10G-EPON US US2 too close to ZDF region Revised Plan A Shift US channels by +100GHz so US2 > 0.64nm from ZDF. Trade-off vs. smaller 10G/US0 gap. Increase DS0-DS1 spacing to 2.4 THz (12.4nm gap). Trade off vs. DS3 closer to 1360nm water peak region. Even with revisions the significant costs of 2nm US passband remain. 4 01/10/2017 IEEE 802.3ca Task Force

Discussion of Plan A with WDM coexistence WDM coexistence can be achieved with all channels in O-band, but there are some aspects that are not ideal. Upstream: Channel spacing is 800GHz which increases ONU mux cost (Traverso_03_0308, 802.3ba). Requires 2nm passband which increases ONU laser cost and may be too narrow to support BM thermal transient (zhang_3ca_1_1116). US0 must be cooled, increasing entry-level 25/25G ONU cost (harstead_3ca_1a_0716). Narrow gap between 10G and US0 increases OLT filter cost. Downstream: Channel spacing is 800GHz, increasing ONU demux cost. DS3 is close to edge of water peak so loss could be high. Can shift to lower wavelength at the expense of ONU blocking filter guardband. Most of the upstream issues can be relieved by the use of TDM coexistence. These are the most important since they have the largest effect on ONU cost. 5 01/10/2017 IEEE 802.3ca Task Force

Plan B with TDM coexistence Harstead_3ca_2b_0916 Revised Plan B Relative to original Plan B keep the most important aspects: TDM coexistence with 10G-EPON Uncooled or semi-cooled 25G US0 is possible Optimize channel spacing and passband width for cost and performance: Increase 100G US CS to 1.2THz and PB width to 3nm, enabling ±1.5nm laser accuracy Increased guardband to US-10G and ZDF compared with Plan A Same DS channel plan as the revised Plan A 6 01/10/2017 IEEE 802.3ca Task Force

Details of revised Plan B channel plan Lane Center Freq (THz) Center WL (nm) US0-25G 236.06 1270.00 US0-100G 236.00 1270.31 US1 232.20 1291.10 US2 231.00 1297.80 US3 229.80 1304.58 DS0 224.60 1334.78 DS1 222.20 1349.20 DS2 221.40 1354.08 DS3 220.60 1358.99 Channel spacing: 800GHz (DS), 1200GHz (US) Laser accuracy: ±1nm (DS), ±1.5nm (100G US), ±10nm (25G US) DS-US gap (min): 53.8nm (25G), 27.7nm (100G) DS0-DS1 gap (min): 12.4nm US0-US1 gap (min): 9.6nm (uncooled US0) US2 to zero dispersion range (min): 0.7nm (124GHz) 7 01/10/2017 IEEE 802.3ca Task Force

Plan B ONU optical filtering The 53.8nm minimum guardband enables 25/25G and 25/10G ONU diplexers using low-cost focused beam BOSA optics with < 0.1dB excess loss. (Funada_3ca_1_0117) The 27.7nm minimum guardband for 100G ONU diplexer dictates use of collimated beam optics. This is acceptable since standard TO-BOSA construction may not apply and 100/100G will be a premium business service. The 12.4nm DS0-DS1 gap allows for low-cost 25G blocking filter with focused beam. 8 01/10/2017 IEEE 802.3ca Task Force

Discussion of Plan B with TDM coexistence TDM coexistence Plan B addresses nearly all of the ONU cost issues identified in WDM coexistence Plan A. The re-use of the 1260-1280nm spectrum for US0 not only allows for the possibility of an uncooled 25/25G ONU but reduces the cost of cooled ONUs as well. Harstead_3ca_1a_0716 vendor input predicts uncooled 25G DML TOSA cost is 57% of a cooled 25G DML TOSA. Zhang_3ca_1_1116 vendor input predicts the cost of laser die with ±1.5nm accuracy is 69% of the cost of laser die with ±1nm accuracy. Even if uncooled laser performance doesn t meet the power budget requirements, cooled DML with relaxed wavelength specs can be used. Uncooled laser performance is expected to improve over the next 5 years so it is highly likely that they will be able to be deployed. 3nm passband width is wide enough to support burst-mode thermal transients (Zhang_3ca_1_1116). The 53.8nm minimum guardband enables 25/25G and 25/10G ONU diplexers using low-cost focused beam BOSA optics with < 0.1dB excess loss. (Funada_3ca_1_0117) 9 01/10/2017 IEEE 802.3ca Task Force

1270±10 100G OLT RX configurations (greenfield) PIN RX 10/25G DR RX 25G US1 RX 25G US2 RX 25G US3 RX APD RX 1.0dB 1.5dB 2.0dB 2.5dB TFF demux SOA 0.5dB DS TX TP2/TP7 Brownfield 10/10G ONU support requires an additional splitter for the 10G 1577nm TX Dual-Rate SOA-PIN RX TFF demux filters can have arbitrary center frequencies and pass-band widths. First channel has lowest insertion loss, < 1dB. Last channel has < 2.5dB insertion loss. Compact ROSA integration 10/25G DR RX Dual-Rate APD RX PIN RX 25G US1 RX 25G US2 RX 25G US3 RX 2.5dB 2.5dB 2.5dB Planar demux SOA 0.5dB 0.5dB TP2/TP7 Split off 1270nm signals before SOA. Low insertion loss to 10/25G dual-rate APD RX More difficult to integrate separate 1270nm splitter DS TX 10 01/10/2017 IEEE 802.3ca Task Force

Straw-man power budget For all channels in O-band, the power budget is independent of details of the exact channel frequencies. Of interest for Plan B is how close are we to being able to implement 25/25G ONUs with uncooled DMLs. Only the 25G OLT case is analyzed here since optical amplification will be used with 100G OLTs to provided any needed gain. Transmitter assumptions (includes BOSA diplexer loss) OLT cooled EML BOSA: Pavg > 5.5dBm, ER > 8dB, TDP < 1.5dB ONU cooled DML BOSA: Pavg > 8dBm, ER > 6dB, TDP < 1.5dB ONU uncooled DML BOSA: Pavg > 6dBm, ER > 5dB, TDP < 1.5dB 100G mux loss = 2.5dB Receiver assumptions (includes BOSA diplexer loss) No enhanced FEC ONU BOSA: Sensitivity < -24 dbm OLT BOSA: Sensitivity < -24dBm for APD or SOA-PIN 100G demux loss = 1dB for US0(1270nm), 2.5dB for US1-3 11 01/10/2017 IEEE 802.3ca Task Force

Power budget: 25G uncooled ONU 25G OLT Parameter DOWN UP DOWN UP Unit Insertion loss, max 24 24 29 29 db Transmitter - 25G Cooled EML Uncooled DML Cooled EML Uncooled DML ER, min 8 5 8 5 db AVP, min 5.50 6.00 5.50 6.00 dbm OMA, min 7.12 6.17 7.12 6.17 dbm Rx Stressed OMA, min -16.88-17.83-21.88-22.83 dbm TDP, max 1.5 1.5 1.5 1.5 db Rx OMA, min -18.38-19.33-23.38-24.33 dbm Receiver - 25G DS0 US0 DS0 US0 AVP Sensitivity, min -24.00-24.00-24.00-24.00 dbm OMA Sensitivity, min -22.38-23.83-22.38-23.83 dbm Margin: 25G - 25G 4.00 4.50-1.00-0.50 db PR20 is no problem. There is a 1dB gap for PR30 downstream due to the limited output power of the EML TX. This is a common issue for all wavelength plans, not specific to this one. Lower EML ER can be traded off for higher OMA topic for future study. There is a 0.5dB gap for PR30 upstream with uncooled DML which can be closed by a 0.5dB improvement in FEC gain. 0.5dB must be added for 10/10G ONU support (brownfield) to account for the additional 10G/25G TX splitter loss, so uncooled power needs 0.5dB improvement. 12 01/10/2017 IEEE 802.3ca Task Force

Summary Given previous arguments that having all channels in O-band is the best performing and lowest cost choice for NG-EPON wavelength plan (johnson_3ca_1_0117), the remaining choice is whether to implement 10G-EPON upstream coexistence with WDM or TDM. Based on the arguments given in this contribution, a TDM coexistence plan has significant cost advantages over WDM due to the limited usable spectrum between the 10G upstream and the zero dispersion window. WDM coexistence dictates the use of 800GHz channel spacing with 2nm passband width which increases ONU optics cost starting with entry-level 25/25G ONUs. TDM coexistence not only increases upstream channel spacing and passband width by 50% but enables the possibility of using uncooled DMLs which are the single most powerful tool for reducing ONU cost. WDM coexistence should only be chosen if service providers consider it to be essential based on 10G and 25G service level requirements. The task force is urged to adopt TDM coexistence in the upstream direction as the baseline for the P802.3ca standard. The revised Plan B shown on slide 7 is one proposed implementation that meets the necessary performance requirements. Small changes to the center frequencies and passband widths can be discussed during the drafting process without affecting the overall benefits of the plan. 13 01/10/2017 IEEE 802.3ca Task Force

Proposed motion Motion #2: The P802.3ca standard shall specify that the first 25G upstream wavelength shall be 1270±10nm and shall coexist with 10G-EPON by time-division multiplexing (TDM). 14 01/10/2017 IEEE 802.3ca Task Force

15 01/10/2017 IEEE 802.3ca Task Force Thank You!