Issue 03/2013. The Electronic Load

Similar documents
Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A

Features. Description. Applications

REGENERATIVE LOAD ERI SERIES

LOW POWER PLA SERIES. Interfaces. Electronic DC Loads

REGENERATIVE LOAD ERI SERIES

Single-output and dual-output power supplies. TOE 8840 up to 160 W TOE 8850 up to 320 W. In-phase regulation

Programmable DC Power Supplies XLN Series

Series Watt DC Power Supplies

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

SSP-KONSTANTER, Series 62 N and Series 64 N Computer Controlled Laboratory Power Supplies

KONSTANTER SPL Series Programmable Electronic Load

LAB-HPP COMPACT HIGH POWER DC SOURCES

Programmable Digital Controlled DC Power Supplies

R&S HMC804x Power Supply 100 W and 1, 2 or 3 Channels

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

EA-EL 3000, EA-EL9000, EA-EL 9000 HP 400W W ELECTRONIC DC LOADS

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

THURLBY THANDAR INSTRUMENTS. PL & PL-P Series. Laboratory Power Supplies. Standard and Programmable models, 35 watts to 240 watts

Programmable DC power supplies

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

SYSKON P1500 Computer Controlled Laboratory Power Supply

MINI MCR-SL-UI-2I(-SP)(-NC)

360W and 720W Programmable DC Power Supplies

Programmable Dual-Range DC Power Supplies 9170 & 9180 series

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Operating instructions. Standstill monitor A / / 2011

AIM & THURLBY THANDAR INSTRUMENTS

VersaMax IP I/O Module

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES

AIM & THURLBY THANDAR INSTRUMENTS

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

AB Axis Industries. Use

Absolute Encoders Multiturn

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

Programmable Power Supplies 188 W 384 W HMP Series

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

Multi-Range Programmable DC Power Supplies 9115 Series

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

This data sheet is only valid in association with the IL SYS INST UM E user manual.

TM221CE40T controller M IO transistor PNP Ethernet

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

ATV1200A kv kva

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

PHOENIX CONTACT Features

Strain Gage Measuring Amplifier GSV-3

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

TM221CE24R controller M IO relay Ethernet

A2000 Multifunctional Power Meter

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

ISOMETER isoev425 with coupling device AGH420

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

TM221M16TG controller M IO transistor PNP spring

PHOENIX CONTACT - 07/2006

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports

Technical data. Your advantages

Communications & Networking

5VPxA SERIES HIGH POWER DC LOADS

AIAS. Technical description

Industrial Power Supplies

AS-i Safety Analog Input Module, IP20

Electronic timer CT-AHD.22

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Data Sheet Rev DALLIS Serial Data

SITOP in the SIMATIC Design

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

Programmable Dual-Range DC Power Supplies 9170B & 9180B Series

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Industrial Power Supplies

VersaPoint I/O Module

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Data sheet CC 03, Commander Compact (603-1CC21)

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

Transcription:

Issue 03/2013

ZS Electronic Loads, PL Series Interface overview RS-232 USB / GPIB LAN System bus Analog X Analog isolated / X Standard ption / not available PL506 PL1006 Voltage Current Resistance 3) Model Continuous Shorttime Rise and fall Housing Connections 4) (order number) power power 1) time 2) PL506 500 W 900 W 60 V 50 A 75 µs 0.1 Ω... ½19, 2HU FK 8 PL506 SC5 5) 300 W 300 W 60 V 5 A 75 µs 1 Ω... ½19, 2 HU PK 4 PL512 500 W 900 W 120 V 20 A 75 µs 0.2 Ω... ½19, 2 HU PK 4 PL524 500 W 900 W 240 V 10 A 75 µs 0.5 Ω... ½19,2 HU SB 4 PL540 500 W 600 W 400 V 8 A 75 µs 1.5 Ω... ½19, 2 HU SB 4 PL1006 1000 W 1800 W 60 V 100 A 75 µs 0.05 Ω... 19, 2 HU FK 8 PL1006 SC10 5) 600 W 600 W 60 V 10 A 75 µs 0.5 Ω... 19, 2 HU PK 4 PL1012 1000 W 1800 W 120 V 50 A 75 µs 0.1 Ω... 19, 2 HU FK 8 PL1024 1000 W 1800 W 240 V 20 A 75 µs 0.3 Ω... 19, 2 HU SB 4 PL1040 1000 W 1200 W 400 V 16 A 75 µs 1 Ω... 19, 2 HU SB 4 PL1506 1500 W 2700 W 60 V 150 A 75 µs 0.04 Ω... 19, 2 HU FK 8 PL1506 SC15 5) 900 W 900 W 60 V 15A 75 µs 0.4 Ω... 19, 2 HU PK 4 PL1512 1500 W 2700 W 120 V 80 A 75 µs 0.06 Ω... 19, 2 HU FK 8 PL1524 1500 W 2700 W 240 V 30 A 75 µs 0.2 Ω... 19, 2 HU SB 4 PL1540 1500 W 1800 W 400 V 25 A 75 µs 0.5 Ω... 19, 2 HU SB 4 1) The possible short time power depends on the temperature of the output stage, i.e. on the previous load. 2) Rise and fall times are defined from 10... 90 % and 90... 10 % of the maximum current. (Constant current operation, tolerance +/- 20 %). 3) is achieved in the context of reproducibility for resistance operation. 4) SB 4: Protected laboratory socket 4 mm PK 4: Pole terminal for 4 mm laboratory jack FK 8: Flat copper rail with M8 screw 5) Devices with reduced setting range 1HU = 1 height unit = 44.45 mm perating Modes Dynamic peration Protective Devices verload Capacity The devices have constantcurrent and constant-resistance operating modes in both static and dynamic operation. If fitted with an RS-232 or GPIB interface, softwarecontrolled constant power control is possible. The manual setting of the load values takes place via two precise ten-turn potentio-meters. Switch from value A to value B by a keystroke. In dynamic mode the inbuilt modulator performs the switch between the setpoints A and B. For each load level it is possible to set a corresponding pulse duration of 0.5 ms... 500 milliseconds. In addition, pulse-pause ratios can be varied within broad time range. Switching between the two load levels can also be via the analogue I/ interface at all levels between 3 V and 30 V. ver-current protection ver-power protection ver-temperature protection ver-voltage protection Reverse polarity protection Protection of the GND lines at the Analog I/ interface If a protected value is exceeded the respective display flashes. The type spectrum comprises three power classes with 500 W, 1000 W and 1500 W continuous load capacity. Depending on the model the devices have temporary overload capacity. The level and duration of the possible overload depends on the operating temperature of the power stage. The device can also be used for significantly higher power tasks. 8

ZS Analog I/ Interface The Analog I/ Interface also Standard Analog I/ Interface with 0... 10V level for: has the following logical inputs and outputs: Input voltage Load current Power consumption Nominal current Master-Slave circuit verload status for the overload display Trigger output during dynamic operation Trigger input for external control of the dynamic load change The control of the load current can be via an analog signal with optionally 0... 5 V or 0... 10 V. Control input for battery test Control Input for external load activation Sense terminals (for 60V and 120 V models) Interfaces RS-232 Interface Requires PL01 or PL02. Factory Calibration ptional interfaces are an RS- 232 and a combined GPIB + RS- 232 interface. The interfaces enable all settings functions including comprehensive dynamic settings incl. programmable rise and fall times. There is also a measurement function for input voltage and load current. All interfaces are electrically isolated from the load input to prevent earth loops forming with the test structures. Programming takes place in SCPI syntax. (ption PL01) The RS-232 interface is the most economical option for controlling devices by PC. It also includes the system bus interface which allows multi-channel systems to be constructed. GPIB + RS-232 interfaces (ption PL02) Combined GPIB + RS-232 interface + system bus interface External LAN-RS232 Adapter (ption PL04) Enables the device to be controlled via LAN interface. Tools The H&H Homepage has a program library for Windows with the following applications: Load control via PC Programming of custom load profiles Recording of current limitation characteristics Endurance test with memory function for voltage and current Battery testing with recording of discharge curves LabVIEW driver Certificate (ption FCC-PLxx) A Factory Calibration Certificate (FCC) can be supplied with the devices. The FCC meets the requirements according to DIN EN IS 9000ff. This calibration certificate documents the traceability to national standards to illustrate the physical device in accordance with the inter-national System of Units (SI). The recommended calibration interval is 1 year. Configuration of a Multichannel System For control of additional devices via the GPIB or RS-232 interface of the primary device, any number of devices can be connected via the system bus interface (ption PL01 in all other devices). Despite the shared interface, the devices are electrically isolated from one another and can be operated with potential differences of up to 125 V. 9

perating temperature ZS Technical Data PL Series Accuracy of manual setting, no preset function Current ±0.4 % ±0.05 % Resistance (at 5% to 100% of the voltage range) ±5 % ±0.5 % of current range Accuracy of manual setting, with preset function Current Accuracy of display of the preset value ±0.6 % ±0.05 % of the measured value (actual value) Voltage ±0.2 % ±0.05 % ±1 digit Current ±0.4 % ±0.05 % ±1 digit Accuracy of analog control 0... 5 V / 0... 10 V for current setting Current 10 V 5 V ±0.5 % ±1.5 % Input resistance of analog inputs 10 kω/20 kω at 5 V/10 V GND max. ±2 V with respect to negative load input Accuracy of analog measurement outputs 0... 10 V for current, voltage, power of analog signal of actual value ±0.2 % ±0.4 % offset voltage Voltage ±0.2 % ±20 mv Current ±0.3 % ±20 mv Power ±5 % ±30 mv Reference voltage 10.5 V Load capacity: minimal 2 kω ±4 % Accuracy of setting Programming via data interface (ption PL01 or PL02) Current ±0.4 % ±0.05 % Resistance (at 5 % to 100 % of the voltage range) Resolution setting 12 Bit ±5 % ±0.5 % of current range Accuracy of measurement, read out via data interface of the measured value (actual value) Voltage ±0.2 % ±0.06 % Current ±0.5 % ±0.12 % Resolution Sampling rate 13 bit Control via Analog I/ interface Status outputs (open collector 30 V) External control functions (Level 3 V... 30 V) Dynamics 300 ms, non-triggering verload Trigger output at dynamic load Load switching off - on Battery test off - on Trigger input for switching dynamic load level two load levels in I and R mode, two separately adjustable times External triggering of load level switching also possible Input Input resistance Input capacity Parallel operation Input voltage Minimum voltage Permissible operating voltage Protective devices Connections: Load input: Sense: Continuous power >50 kω when load input is off Approx. 2 µf / 500 W Up to 5 units in Master-Slave mode (hardware-controlled) Min. 1.4 V for max. current including linear derating of current with respect to 0 V Negative load input - housing 125 V DC ver-voltage up to 120 % of rated voltage, over-current, over-power, over-temperature, reverse polarity up to rated current, transient protection, display by flashing of current and/or voltage display, under-voltage display (if input voltage is too low for the set load) up to 120 V: available on I/ interface from 240 V: unavailable (where TA = 21 C) Derating -1.2 % / C for TA > 21 C verload capacity Time range for internal modulator Accuracy of the time setting Battery test Adjustable cut-off voltage Presetting function Current mode Resistance mode perating conditions Cooling 1 ms... 500 ms (2 Hz... 1 khz) ±10 % ± 0.2 ms the load is reduced to 0 on reaching the cut-off voltage (I/V mode, R/V mode) Direct display of load current Display of expected load current with applied input voltage 5 C... 40 C 2-stage air-cooling Noise PL5XX PL10XX PL15XX 55 dba 59 dba 60 dba Supply voltage Power consumption Dimensions W x B x D (mm) weight Colour Front panel, back panel side panels, top 115/230 V~ ±10 %, switchable 50... 60 Hz PL5XX PL10XX PL15XX max. 30 VA max. 50 VA max. 60 VA PL5XX PL10XX PL15XX 222 x 88 x 390 444 x 88 x 390 444 x 88 x 390 6 kg 12 kg 16 kg RAL7032 (pebble grey) RAL7037 (stone grey) Electrical safety DIN EN 61010: 2002-08 EMC, CE marking DIN EN 61326-1: 2006-10 DIN EN 61000-3-2: 2006-10 DIN EN 61000-3-3: 2006-06 19 mounting kits for models order number 1 PL5XX ES PL05-1 2 PL5XX ES PL05-2 PL10XX or PL15XX ES PL2 Warranty 2 years Subject to technical modifications 10

Hoecherl & Hackl GmbH Industriestr. 13 94357 Konzell Germany Tel.: +49 9963/94301-0 Fax.: +49 9963/94301-84 E-Mail: office@hoecherl-hackl.com http://www.hoecherl-hackl.com