Similar documents
CHEP ATEX. IECEx. Explosion proof Camera Housing. and. Certified

CHXES Stainless Steel Camera Housing

tekno system Italian design for CCTV since 1979 General Catalogue

EX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom

HAZARDOUS AREA DAY/NIGHT HD CAMERAS

1 CAMERA HOUSINGS VERSO POLAR 17. Innovative and stylish housing, entirely built in technopolymer, and

EX-PROOF THERMAL ANALOGUE CAMERAS IN COMPACT DESIGN EC-840S-TIC-19A - Series

MAXIMUS MMX EX-PROOF FULL HD CAMERA IN A COMPACT DESIGN

EX-BC820v2H3 F series Explosion-proof full-hd fixed IP camera

Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Ex e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612

EX-BC36 PTZ series Explosion-proof analogue PTZ camera station

The iwap107 supports 100/1000Base-T, offering a significant increase in speed over the older fast Ethernet standard.

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

HAZARDOUS AREA DAY/NIGHT PTZ HD CAMERA

Evolution 05 and 12. Model

Load Disconnect Switches and Motor Switches

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Terminal Boxes Series 8118

HAZARDOUS AREA PTZ IP NETWORK CAMERA

Installation & Operation Manual

EX-TC620 PTZ series Explosion-proof thermal PTZ camera station

EXPLOSION-PROOF FULL HD PTZ CAMERA WITH NEW DELUX TECHNOLOGY, FOR DAY/NIGHT VIEWING WITH EXCEPTIONAL NIGHT BRIGHTNESS

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

TYPE 4X TYPE 6P PROTECTION PROTECTION

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Dräger Polytron 8200 Stationary gas detector (CatEx)

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Installation & Operation Manual

ExCos-P Pressure sensor 20 Pa Pa

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Material pressure (bar) (Cv (US) kv x 1,2 Seat

MAXIMUS MVX HIGH-SPEC EX-PROOF DAY/NIGHT CAMERA IN A COMPACT DESIGN

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

EC-940-AFZ OUR NEW CAMERA DESIGN

MAXIMUS MMX EX-PROOF FULL HD CAMERA IN A COMPACT DESIGN

EX-PROOF DUAL VISION PTZ CAMERA, DAY/NIGHT AND THERMAL

MAXIMUS MMX EX-PROOF FULL HD CAMERA IN A COMPACT DESIGN

Loads and Motor Switchgears

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

MAXIMUS MVXHD HIGH-SPEC EX-PROOF HD CAMERA IN A COMPACT DESIGN

About the FLEX Ex I/O Systems

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

EPoC series. Features

Linear Luminaire with LED Series 6012/5

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

System Highlights. Pan/Tilt resolution

M C. Ex d M-0... control, monitoring and signalling devices

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

IP66 PROTECTION TYPE 4X ULISSE NETCAM

MAXIMUS MPXHD EXPLOSION-PROOF FULL HD PTZ CAMERA

dome camera. Image Inverse feature

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Technical Data. General specifications. Rated operating distance s n 3 mm

EC-910-AFZ. Compact all-round camera for hazardous areas

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Linear Luminaire with LED Series 6412/5

Float switch For the process industry, lateral installation with external chamber Model ELS

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

EX-BC820v2H3-TC620 D series Explosion-proof dual head PTZ camera station

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

Technical Information Promonitor NRF560

RT2Y Compact temperature switch intrinsic safety

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

1/2 High-Resolution CCD Resolution 700 TVL Min. illumination Lux True Day & Night (ICR), SSNRIII. Pan/Tilt resolution

Save installation time and money with PoE and get the most out each PoE connection with PoE passthrough!

Safety switches with separate actuator

Micro Limit Switch Series 8064

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

BA444DF-P PROFIBUS PA Intrinsically safe Field mounting 8 variable Fieldbus Indicator Issue 2

CTO CSLS Field Enclosure

Grounding Monitoring Device Series 8485

Technical features. N/en

CombiView DFON Graphical display

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

XLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance

DR7100 SERIES Supplementary instructions

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

ExCam. Series. ATEX Installation Manual

KINAX WT720 absolute, programmable angular postion transmitter

Installation & Operating Manual. iwap200

SPECIALTY PRODUCTS. Flameproof housing Zones 1-2 and to encase video cameras. Used for onshore and offshore sites and process supervision.

Grounding Monitoring Device Series 8485

EX-HSD820v2H3 PD series Explosion-proof full-hd PTZ dome camera

MAXIMUS MPX EX-PROOF PTZ DAY/NIGHT CAMERA

SolConeX extra-low voltage flange socket

CTO CHARM Field Enclosure

Transcription:

CHEP INOX Stainless Steel Explosionproof Camera Housing ATEX and IECEx Certified CHEP INOX Stainless Steel AISI 316L Explosionproof Camera Housing EXPLOSION PROOF HOUSING Different versions available to satisfy the different specs required by different hazardous environments FOR EXTREMELY HARSH ENVIRONMENTS Temperature range from 50 C to +50 C, protection rate IP66 and IP67, entirely constructed of Stainless Steel AISI 316L, possibility to install a glass protection grid USER FRIENDLY All the professional installers can easily install on-site the Ex housing and camera AVAILABLE WITH Hi-PoE MKII SPLITTER Video data and feeding power are brought in through one single CAT5e or higher cable. New Punch Down Terminal fast connection. Page 1 / 6

TECHNOLOGY HIGHLIGHTS CHEP (Anticorodal Aluminium) / CHEP (Stainless Steel AISI 316L) General Description: Explosion proof housing to be installed in zone where the forming of potentially explosive atmosphere is possible due to the presence of Group IIB-IIC gasses, fumes, smokes and powders even mixed among them. It can be installed in hazardous locations, indoor or outdoor, classified 1-21, 2-22 in which the environment temperature has to be included between 20 and +50 C or between 50 and +50 C. Constructed of Anticorodal aluminium for sites with potentially explosive atmosphere where electrical constructions of Group II, category 2, are foreseen. On request, it can be constructed of Bronze B14 or Stainless Steel and in this case it can be used in mines, where electrical constructions of Group I, category M2, are foreseen. It is also available a special version with Germanium filter and protection grid for thermal cameras. The anodic oxidation treatment assures an extremely high resistance against corrosion from atmospheres agents, salty fog or polluting elements of the air. On the back side, two ½ or ¾ cable glands allow to feed the devices inside the housing in high or low voltage. On request, cable glands of different brands and different kind can be provided. As a consequence of the zone where the housing has to be installed, there will be used cable glands with seal rubber (suitable for zone with presence of Group IIB gases) or barrier cable glands with connection cables sealed (suitable for zone with presence of Group IIC gases). All this in conformity with the electrical plants laws in force. Internal devices: On its inner, the housing is provided of a heating system with one or three PTC to avoid the condensation on the glass. These heating elements are working with 12 to 24V and with 100 to 240V voltages and are driven by a thermostat positioned on the circuit board which allows the electrical connection of all the feeded elements with the main voltage. Depending on the model required, the housing can be equipped also with a factory installed power supply, useful to correctly feed the devices in case that their feeding voltage is different than the mail voltage. The power supply can be supplied with three different voltages: 230V~/12VDC, 230V~/24V~, 115V~/24V~, 24Vac/12VDC. High Power over Ethernet The Hi-PoE MKII splitter for IP Cameras or the Hi-PoE MKII PLUS for IP PoE cameras are available. Video data and feeding power are brought in through one single CAT5e cable with a Punch Down Terminal for a fast connection of the cable. Laser devices It is well known that laser devices, radiation class 1 and 2, do find many applications for civil as well as industrial use. In particular, they are utilized to monitor industrial processes, to measure levels and distances, to control moving objects, to check the position of objects (i.e. vessels, cars, etc). In these applications it is often required to the laser device to be explosion proof, being the installation in one of those areas defined as potentially explosives. The Atex certification covers laser devices radiation class 1 and 2, making the CHEP enclosure the proper answer for these applications. Installation: The installer has to open the housing to internally install the devices, excluding those already supplied by the manufacturer. Specifically, for the CCTV there will be the use of analog cameras to reproduce the video image through a coax cable, or digital through Ethernet. At present, the market of those systems offer a wide range of brands for such devices.the installer will choose the best camera for the particular installation. This operation see the dismount of the back closing flange which is equipped with cable glands and it is fixed to the housing body by six screws. Three additional screws with a smaller diameter are supplied: these screws, set at 120 one to the other, can make the job even much easier. Actually,screwing these additional screws one turn at the time, after having unscrewed the other six screws, the flange comes out smoothly. For the correct positioning of the devices the housing is equipped with an internal slide on which they can be fixed by means of screws. During the installation it is important to have the right adjustment height of the camera respect to its leaning level. So, the image will be balanced on the frontal window. This operation is possible due to the provided adjusting height kit which works also as insulator from the internal slide. At the end of all the operations it is necessary to close the housing using the six screws that were unscrewed at the beginning of the operation. On demand the housing can be equipped with sunshield, frontal glass protection grid, bracket with swivel for wall or ceiling fixing. The accessories are sold spare, their assempling is done by the installer. Page 2 / 6

MODELS ORDER CODE II 2GD Ex d IIB T6 Ex td A21 IP66 II 2GD Ex d IIC T6 Ex td A21 IP66 T85 C T85 C with Cable Glands for gas group IIA (Propane) and IIB (ethylene) only with Cable Glands for gas I M2 Ex d I for Mines Only made of AISI Temperature Temperature Cable Glands Size ½ and on demand ¾ -20 C/+50 C -50 C/+50 C (with single Heater HT) (only with triple heater HTTT) group IIC (acetylene, 316L Stainless Steel or B14 Bronze hydrogen) IP RATE CHEP IIB CHEP IIB G Germanium Window Grid CHEP IIC CHEP IIC G CHEP IIB (-50 C) CHEP IIC (-50 C) CHEP M CHEP M (-50 C) Page 3 / 6

ACCESSORIES HT HTTT AL EL Heater with thermostat* Triple heater with thermostat* Power supply* Camera adjusting height kit BWXHX Stainless Steel AISI 316L wall bracket with swivel SSEP Stainless Steel AISI 316L sunshield G Frontal glass protection grid* *Accessories available only factory installed Hi-PoE MKII ACCESSORIES PLUS Dedicated PoE camera module for digital cameras that only allow PoE feed. (HiPoE MKII PLUS)* Injector Single Channel Hi-PoE Injector *Accessories available only factory installed RELATED PRODUCTS CMX Stainless Steel corner adaptor Page 4 / 6

Page 5 / 6

TECHNICAL DATA General Construction: made of Stainless Steel AISI 316L, Internal useful volume WxHxL: Please refer to drawings External dimensions: Please refer to drawings Protection rate IP66 and IP67 ATEX marking: II 2GD Ex d IIB/IIC T6 Ex td A21 IP 66/67 T85 C I M2 Ex d I IECEX marking: Ex d IIC T6 or Ex d IIB T6 Ex td A21 IP66 T85 C or Ex td A21 IP67 T85 C Ex d I Marking rating plate laser incision Accessories Sunshield Front glass protection grid Bracket with swivel for wall or ceiling. Special versions Housing with germanium filter for thermal cameras Housing for mines Laser devices Atex/Iecex certification covers laser devices radiation class 1 and 2 Mechanical Dimensions : please refer to the drawings Cable glands : n. 2 cable glands ½ or ¾ On request are available different brand and model of cable glands. Housing weight : 30,00 Kg Accessories weight : 2,90 Kg (BWX bracket) Electrical Thermostat: Ton 15 C (59 F) ± 5 C Toff 22 C (71.6 F) ± 4 C Heater: Single with thermostat for temperatures from 20 C to + 50 C (12-24Vac/Vdc or 100-240Vac) Triple with thermostat for temperatures from 50 C to + 50 C (12-24Vac/Vdc or 100-240Vac) Heater PTC (HT12-24) 12-24V~ 20W Heater PTC (HT230): 100-240V~ 40W Camera power supply (AL): Vin 230V~ 50Hz Vout 12VDC 400mA; Vin 230V~ 50Hz Vout 24V~ 400mA; IMPORTANT: TOTAL POWER ABSORBED BY VIDEO SURVEILLANCE EQUIPMENT INSTALLED IN THE CHEP EXPLOSIONPROOF CAMERA HOUSING MUST NOT EXCEED 20 W. IF THE CAMERA HOUSING IS INCLUDING ANY POWER SUPPLY INSTALLED BY MANUFACTURER VIDEO SURVEILLANCE EQUIPMENT INSTALLED BY THE END USER MUST NOT EXCEED 10 W. CHEP HiPoE Working temperature range from -20 C to +50 C HiPoE MKII 12VDC 24W splitter with integrated heater and blower thermostats: Punch Down Terminal fast connection Gigabit compatible Compliant with IEEE802.3at Warning: o The camera housing is compatible only with camera with output selectable 12Vdc or 14,5Vdc voltage feeding o The splitter Ethernet Output is not PoE HiPoE MKII PLUS dedicated PoE injector IEEE 802.3af compliant built in for digital cameras that only allow PoE feed. the two terminal blocks marked +POWER- will be not used Environment Indoor and outdoor application IP rate (EN60529) : IP66 and IP67 Temperature range : -20 C / +50 C or -50 C / +50 C ATEX, IECEX, CE RoHS compliant Technical data and product features might be modified without any warning. Page 6 / 6