Installation instructions Ethernet switch EC / / 2011

Similar documents
Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Speed monitor D / / 2014

Operating instructions RFID evaluation unit DTE / / 2016

Quick reference guide 3D sensor O3D3xx

Operating instructions. Standstill monitor A / / 2011

Installation instructions Inclination sensor EC2019 EC / / 2013

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

Operating instructions Evaluation system for flow sensors VS / / 2013

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GG711S

Brief instructions Illumination unit O3M950 O3M /00 03/2016

Brief instructions Illumination unit O3M /00 09/2014

Operating instructions IO-Link master CabinetLine AL19xx

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Hardware Manual RM CANview

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Operating instructions Optical distance sensor. OID20x / / 2014

MC 11 EB-2 Power supply cabinet with external bus, AC version

Operating instructions. Monitor FD / / 2013

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

FL MC 2000E (SM40) LC

Operating instructions. Monitor FS-2 / FS-2N / / 2013

QUINT-BUFFER/24DC/24DC/40

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Hardware Manual RM CANview Gateway

EFX 3232m Installation Instructions

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Installation Guide. O2Vxxx / / 2015

CPCI-PS24 24V-Power Supply

Operating instructions Optical distance sensor. OID20x / / 2015

PHOENIX CONTACT - 10/2009

MOXA EtherDevice Switch

Device manual Inclination sensor 2 axes JN /00 04/2015

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

C9900-P208 and C9900-P209

C9900-P223 and C9900-P224

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions. Monitor FR-1 / FR-1N / / 2013

MINI-PS AC/10-15DC/8

Hardware Manual RM Display 2501 S01..S04

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Hardware Manual RM Display 2401

2 Mesa Ethernet Dock User s Manual

TRC-190 User s Manual

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Serial PROFIBUS Interface

Original operating instructions Safety relay with relay outputs G1501S / / 2016

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Brief instructions Starter set BasicController BasicRelay BasicDisplay EC / / 2011

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Assembly and Operating Instructions. M2 module for BDC-i440 control units

AO561 Analog Output Module

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

PHOENIX CONTACT - 07/2006

TRIO-DIODE/12-24DC/2X10/1X20

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Installation Guide. O2Ixxx / / 2015

Operating instructions Pressure sensor. PN50xx / / 2010

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Installation instructions ClassicController CR / / 2014

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

TN-5308 Quick Installation Guide

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

SUBCON-PLUS-PROFIB...

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

24-Port Gigabit Ethernet Switches

Power supply module, bus connection module

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Operating Instructions

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Power Supply HARTING pcon

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

Operating instructions Programming and display unit PP / / 2010

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

Hardware Manual RM Display 1001

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Transcription:

Installation instructions Ethernet switch EC2095 7390731 / 00 02 / 2011

Contents 1 Preliminary note................................................. 3 1.1 Symbols used............................................... 3 1.2 Warning signs used.......................................... 3 2 Safety instructions............................................... 4 2.1 General.................................................... 4 2.2 Target group................................................ 4 2.3 Electrical connection......................................... 4 2.4 Tampering with the device..................................... 4 3 Functions and features............................................ 4 3.1 Features at a glance.......................................... 5 4 Installation...................................................... 6 4.1 Installation position and mounting surface......................... 6 4.2 Fixing..................................................... 6 5 Electrical connection.............................................. 6 5.1 Wiring..................................................... 6 5.2 Operating voltage............................................ 7 5.3 Ground connection........................................... 7 5.4 Ethernet................................................... 7 5.5 Assignment of the ports....................................... 7 5.5.1 Cover all unused ports.................................... 8 6 Indicators...................................................... 8 7 Set-up/Operation................................................ 8 8 Technical data................................................... 9 9 Maintenance, repair and disposal....................................11 10 Approvals/standards.............................................11 This document is the original instructions. Licences and trademarks Microsoft, Windows, Windows XP and Windows Vista are registered trademarks of Microsoft Corporation. All trademarks and company names are subject to the copyright of the respective companies. 2

1 Preliminary note This document applies to devices of the type "Ethernet switch" (art. no.: EC2095). It is part of the unit. This document is intended for specialists. These specialists are people who are qualified by their appropriate training and their experience to see risks and to avoid possible hazards that may be caused during operation or maintenance of the device. The document contains information about the correct handling of the device. Read this document before use to familiarise yourself with operating conditions, installation and operation. Keep this document during the entire duration of use of the device. Adhere to the safety instructions. 1.1 Symbols used Instructions > Reaction, result [ ] Designation of pushbuttons, buttons or indications Cross-reference Important note Non-compliance can result in malfunction or interference. Information Supplementary note 1.2 Warning signs used WARNING Warning of serious personal injury. Death or serious irreversible injuries may result. CAUTION Warning of personal injury. Slight reversible injuries may result. NOTE Warning of damage to property. 3

2 Safety instructions 2.1 General These instructions contain texts and figures concerning the correct handling of the device and must be read before installation or use. Observe the operating instructions. Non-observance of the instructions, operation which is not in accordance with use as prescribed below, wrong installation or incorrect handling can seriously affect the safety of operators and machinery. 2.2 Target group These instructions are intended for authorised persons according to the EMC and low-voltage directives. The device must only be installed, connected and put into operation by a qualified electrician. 2.3 Electrical connection Disconnect the unit externally before handling it. If necessary, also disconnect any independently supplied output load circuits. If the device is not supplied by the mobile on-board system (12/24 V battery operation), it must be ensured that the external voltage is generated and supplied according to the criteria for safety extra-low voltage (SELV) as this voltage is supplied without further measures to the connected controller, the sensors and the actuators. The wiring of all signals in connection with the SELV circuit of the device must also comply with the SELV criteria (safety extra-low voltage, safe electrical isolation from other electric circuits). If the supplied SELV voltage is externally grounded (SELV becomes PELV), the responsibility lies with the user and the respective national installation regulations must be complied with. All statements in this document refer to the device the SELV voltage of which is not grounded. The connection terminals may only be supplied with the signals indicated in the technical data and/or on the device label and only the approved accessories of ifm electronic may be connected. 2.4 Tampering with the device In case of malfunction or uncertainties please contact the manufacturer. Tampering with the device can seriously affect the safety of operators and machinery. It is not permitted and leads to the exclusion of any liability and warranty claims. 3 Functions and features The device is used for networking up to 5 Ethernet devices. It enables, for example, connection of a process and dialogue monitor PDM 360 with up to 4 Ethernet cameras. 4

PDM 360 Ethernet Cameras Ethernet Switch power supply Application example 3.1 Features at a glance 5 ports with 10/100 Mbits/s Auto-negotiation Transmission speed and mode (half/full duplex) of the connected devices are recognised and set automatically. Auto-crossing The port output and input are automatically switched to the corresponding pairs of wire. Crosslink or patch cables (1:1) can be used. Switching method: Store and forward technologies The device learns up to 2000 MAC addresses. Thanks to independent subnets more than one final unit can be connected to one or several ports. Plug and play Software installation or parameter setting is not necessary. Protection IP 67 (All ports used and/or unused ports protected by caps.) 5

4 Installation 4.1 Installation position and mounting surface Installation position as required No uneven mounting surface NOTE The housing must not be exposed to any torsional forces or mechanical stress. Damage possible. Fix the device only on plane surfaces. Ensure that the contact area of the device lies completely flat on the mounting surface. 4.2 Fixing The device is fixed with 6 M5 screws. Tighten the screws alternately crosswise. Mounting dimensions 7 Technical data Screw material: steel Tightening torque: 8 ±2 Nm 5 Electrical connection 5.1 Wiring Wiring 7 Technical data NOTE Wrong connection may cause damage to the device. Observe the safety instructions. First establish the Ethernet connections, then the supply voltage. Basically all supply and Ethernet cables must be laid separately. 6

Lay supply and Ethernet cables away from the device using the shortest possible route. All connected cables must be provided with a strain relief. 5.2 Operating voltage The supply voltage can be connected to V1 or V2 as option. 2 different sources have to be connected for redundant operation, however. Core cross-section: 0.3...1.3 mm. Cable length for optimum performance: 10 m To protect the device use fuses for the operating voltages. Description Potential M12 connector (5 poles) Fuse Operating voltage V1 10 30 V DC (V1) Pin 1 max. 2 A T Operating voltage V2 10 30 V DC (V2) Pin 4 max. 2 A T The operating voltage is electrically separated from the functional earth. 5.3 Ground connection To ensure the protection of the device against electrical interference, the housing must be connected to GND (e.g. to the ground of the vehicle). For permanent installation in a vehicle connect the ground via an M5 fixing screw. Core cross-section: 0.5 mm² Ensure a well-conductive connection. 5.4 Ethernet Use a shielded CAT5 cable. STP, Shielded Twisted Pair, according to EIA/TIA-568. Max. length 100 m Use screened connector housings and connect the screen of the Ethernet cable to the connector housing. Do not lay the Ethernet cable in parallel to live cables. 5.5 Assignment of the ports Ports 1... 5 can be used by the devices as required. ( 3 Intended use, application examples) Connection from one port to another port on the same Ethernet switch is prohibited. It will cause a failure of the network (broadcast storm). 7

5.5.1 Cover all unused ports NOTE Moisture penetrating through unused or unprotected ports may destroy the device. Cover unused ports with protective caps. 6 Indicators 1 2 Power LNK/ACT 3 4 5 1: LED Power (green) 2: LED LNK/ACT (green) Operating states (LED) 7 Technical data 7 Set-up/Operation After installation and electrical connection the device is ready for operation. A restart (operating voltage ON/OFF) or if the operating voltage drops below the set value will delete the taught address entries. The device is reset and newly initialised. Interference due to external influences Faulty or insufficient radio interference suppressors in other electrical equipment, such as inverters or generators, as well as voltage fluctuations when switching on/off electric loads may lead to problems with the data transmission. 8

8 Technical data EC2095 48,3 48,3 e1 Ethernet switch 5 ports 10/100Base-TX 1 2 Autosensing speed Auto-negotiation Auto-crossover IP 67 127 111,8 3 4 5 61,2 96,5 Redundant voltage supply 10...30 V DC 25 5,1 3,6 109,7 43,4 56,1 Technical data e.g. for the connection of up to 4 O2M Ethernet cameras to a PMD360 process and dialogue monitor Material Dimensions (H x W x D) Installation Weight housing: aluminium xing plate: stainless steel 109.7 x 127 x 56.1 mm mounting holes for 6 x M5 0.85 kg Operating temperature 40...80 C Storage temperature 40...85 C Relative air humidity Operating altitude 5...100 % (non condensing) 3000 m (above sea level) Protection rating IP 67 Operating voltage Current consumption Inrush current MTBF 10...30 V DC (redundant) 215 ma (24 V DC) 7.8 A / 0.7 ms (24 V DC) > 2 x 10 6 h Ports 5 Transmission rate Cables to be used Auto-negotiation Auto-crossing 10/100 Mbit/s (10/100Base-TX to IEEE 802.3) Cat. 5 UTP/STP, max. 100 m (shielded twisted pair STP recommended) yes (transmission speed and mode (half and full duplex) are automatically recognised and set) yes (no crossover cable required) MAC addresses to be administered 2000 Max. buffer size Max. frame size Display Operating voltage Ethernet 512 Kbytes 1522 bytes one LED for each connection 1 LED green (power) 5 LEDs green (LNK/ACT) ifm electronic gmbh Friedrichstraße 1 45128 Essen We reserve the right to make technical alterations without prior notice! EC2095 / page 1 22.02.2011 9

EC2095 Technical data Operating states (LED) LED Status Description Power off no operating voltage LNK/ACT (for each port) on off on ashing operating voltage OK no connection connection exists ongoing data transmission Test standards and regulations Interference emission Noise immunity to conducted HF and interfering elds Safety e1 type approval EN61000-6-4, EN55011 - class A FCC title 47, part 15, subpart B - class A ICES-003 class A EN61000-6-2 EN61000-4-2 (ESD) EN61000-4-3 (RS) EN61000-4-4 (EFT) EN61000-4-5 (Surge) EN61000-4-6 (Conducted Disturbances) UL listed per ANSI/ISA-12.12.01-2000 (US and Canada) and is listed for use in class I, div 2, groups A, B, C, and D, T4A to directive 2009/19/EC Wiring Operating voltage M12 connector, A-coded, 5 poles Pin Potential 2 1 5 3 4 1 2 3 4 5 10...30 V DC (V1) GND (V1) GND (V2) 10...30 V DC (V2) functional earth Ethernet M12 socket, D-coded, 4-poles Pin Potential 1 2 4 3 1 2 3 4 housing TxD RxD TxD RxD screen ifm electronic gmbh Friedrichstraße 1 45128 Essen We reserve the right to make technical alterations without prior notice! EC2095 / page 2 22.02.2011 10

9 Maintenance, repair and disposal The device is maintenance-free. Do not open the housing as the device does not contain any components which must be maintained by the user. The device must only be repaired by the manufacturer. Dispose of the device in accordance with the national environmental regulations. 10 Approvals/standards Test standards and regulations 7 Technical data. The EC declaration of conformity and approvals can be found at: www.ifm.com Data sheet direct: EC2095 Approvals 11